Harness the Power of Automated Lighting Control for Your Restaurant

Restaurants are bustling spaces, filled with the aroma of delicious food, the clinking of cutlery, and the hum of conversation. However, behind the scenes, they are also high-energy consumption areas, particularly when it comes to lighting. From the warm ambient lighting that sets the mood, to the bright task lighting in the kitchen, and the safety lighting in storage areas, restaurants use a variety of lighting types, all of which consume significant amounts of energy.

Moreover, the irregular and extended operating hours of restaurants often lead to lights being left on unnecessarily, resulting in high energy waste. This not only impacts the restaurant’s bottom line but also contributes to the larger issue of energy conservation.

To address this, Rayzeek offers a solution in the form of occupancy sensors. These sensors can automatically control lighting based on the presence or absence of people, reducing energy consumption significantly. In a restaurant setting, this means lights in the dining area, kitchen, restrooms, and storage areas can be automatically turned off when these spaces are not in use, without any manual intervention. This not only saves energy but also complies with energy efficiency requirements set by US Energy Codes/Energy standards.

Overhold energireglementerne

International Energy Conservation Code (IECC) er en modelstandard udviklet af International Code Council (ICC) med henblik på at fastsætte minimumskrav til projektering og udførelse for energieffektivitet i bygninger. IECC opdateres hvert tredje år for at integrere de nyeste praksisser og teknologier inden for energibesparelse.

IECC – Hvorfor det er vigtigt for dig

IECC er udbredt i delstater og kommuner over hele USA. IECC dækker forskellige aspekter af energiforbrug, herunder klimaskærmen (vægge, tag og vinduer), varme- og kølesystemer samt belysningsanlæg.

IECC stiller krav om specifikke belysningsstyringer, såsom tilstedeværelsessensorer, for at minimere energispild i ubrugte rum på tværs af forskellige områder.

ANSI/ASHRAE/IES Standard 90.1, Energy Standard for Sites and Buildings Except Low-Rise Residential Buildings, er en vidt anerkendt energistandard udgivet af American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).

ASHRAE 90.1 – Hvorfor det er vigtigt for dig

ASHRAE 90.1 anvendes som reference for bygningsreglementer i hele USA og fungerer som en overholdelsesmetode inden for IECC, der opstiller minimumskrav til energieffektive ydelser i erhvervsbygningers komponenter, herunder klimaskærme, HVAC-systemer, brugsvandssystemer og belysningsanlæg.

ASHRAE 90.1-standarden angiver maksimalt tilladte belysningseffekttætheder og minimumskrav til belysningsstyring, herunder brugen af tilstedeværelsessensorer i specifikke områder.

Title 24, del 6 af California Building Standards Code, officielt kendt som Building Energy Efficiency Standards for Residential and Nonresidential Buildings, Title 24 administreres af California Energy Commission og opdateres med jævne mellemrum for at afspejle nye teknologier og metoder inden for energieffektivitet.

Title 24 – Hvorfor det er vigtigt for dig

Title 24 er kendt for sine strenge krav, der ofte anses for at være mere vidtgående end kravene i mange andre energireglementer i USA. Title 24 opstiller strenge energiydelsesstandarder for alle aspekter af bygningskonstruktion, hvilket omfatter opvarmning, ventilation, aircondition (HVAC), brugsvand og belysning.

Title 24 kræver installation af tilstedeværelsessensorer, der tilpasser belysningen baseret på personers tilstedeværelse i specifikke områder af erhvervsbygninger for at sikre, at der ikke spildes energi.

Implementering af energireglementer efter delstat

Fold ud for at se den detaljerede tabel ↓

DelstatGældende erhvervsbygningsreglementEffektivitetskategori for erhvervsbygningsreglement
Alabama90.1-201390.1-2013
AlaskaIngen på delstatsniveauIntet reglement på delstatsniveau
ArizonaKommunalt selvstyre<90.1-2007
Arkansas2009 IECC og 90.1-200790.1-2007
Californien2022 Building Energy Efficiency Standards90.1-2019
ColoradoKommunalt selvstyreIntet reglement på delstatsniveau
Connecticut2021 IECC og 90.1-201990.1-2019
Delaware2018 IECC og 90.1-201690.1-2013
District of Columbia90.1-2013^90.1-2019
Florida2021 IECC og 90.1-2019^90.1-2016
Georgia2015 IECC og 90.1-2013^90.1-2013
HawaiiKommunalt selvstyre90.1-2013
Idaho2018 IECC og 90.1-201690.1-2013
Illinois2021 IECC og 90.1-201990.1-2019
Indiana90.1-200790.1-2007
Iowa2012 IECC og 90.1-201090.1-2007
KansasKommunalt selvstyreIntet reglement på delstatsniveau
Kentucky2012 IECC og 90.1-201090.1-2007
Louisiana2021 IECC og 90.1-2019^90.1-2016
Maine2015 IECC og 90.1-201390.1-2013
Maryland2021 IECC og 90.1-2019^90.1-2019
Massachusetts2018 IECC og 90.1-2016^90.1-2019
Michigan2015 IECC og 90.1-2013^90.1-2013
Minnesota90.1-2019^90.1-2019
MississippiIngen på delstatsniveauIntet reglement på delstatsniveau
MissouriKommunalt selvstyreIntet reglement på delstatsniveau
Montana2021 IECC og 90.1-201990.1-2019
Nebraska2018 IECC og 90.1-201690.1-2013
Nevada2018 IECC og 90.1-201690.1-2013
New Hampshire2018 IECC og 90.1-2016^90.1-2013
New Jersey90.1-201990.1-2019
New Mexico2021 IECC og 90.1-2019^90.1-2019
New York2018 IECC og 90.1-2016^90.1-2016
North Carolina2015 IECC og 90.1-2013^90.1-2010
North DakotaKommunalt selvstyreIntet reglement på delstatsniveau
Ohio2021 IECC og 90.1-2019^90.1-2016
Oklahoma2006 IECC og 90.1-2004<90.1-2007
Oregon90.1-201990.1-2019
Pennsylvania2018 IECC og 90.1-201690.1-2013
Rhode Island2018 IECC og 90.1-2016^90.1-2013
South Carolina2009 IECC og 90.1-200790.1-2007
South DakotaKommunalt selvstyreIntet reglement på delstatsniveau
Tennessee2021 IECC og 90.1-201390.1-2007
Texas2015 IECC og 90.1-201390.1-2013
Utah2021 IECC og 90.1-2019^90.1-2019
Vermont2021 IECC og 90.1-2019^90.1-2019
Virginia2021 IECC og 90.1-2019^90.1-2019
Washington2018 Washington State Energy Code90.1-2019
Tennessee2012 IECC og 90.1-201090.1-2007
Texas2015 IECC og 90.1-201390.1-2013
Utah2021 IECC og 90.1-2019^90.1-2019
Vermont2018 IECC og 90.1-2016^90.1-2019
Virginia2021 IECC og 90.1-2019^90.1-2019
Washington2018 Washington State Energy Code90.1-2019
West Virginia90.1-201390.1-2013
Wisconsin2015 IECC og 90.1-2013^90.1-2010
WyomingKommunalt selvstyreIntet reglement på delstatsniveau
  • ^ When an amendment impacting energy efficiency can be quantified using DOE Prototype Building Models, they were captured in the analysis.
  • For states adopting both IECC and 90.1, the IECC code is usually analyzed as the state current code in this study except for states with extensive amendments to the IECC.

Sensor Solutions

Find out how Rayzeek can solve your energy saving challenges.

Se alle tilbud

Design Guide Key Concepts for Restaurants

Designing an energy-efficient lighting control solution for restaurants involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.

In a restaurant setting, the placement of occupancy sensors can be tailored to the specific needs of each area. Here’s a possible design guide:

  • Dining Area: Ceiling occupancy sensors can be installed to cover the main dining area. These sensors can automatically turn on the lights when guests are seated and turn them off when the area is vacant. To avoid any blind spots, ensure that the coverage areas of these sensors overlap. This ensures that the dining area is always well-lit when needed, enhancing the dining experience while saving energy.
  • Køkken: Given the high activity level in restaurant kitchens, wall occupancy/vacancy sensors can be installed. These sensors can be manually turned on at the start of the day and when the kitchen is not in use, especially during off-peak hours, the lights can be automatically turned off, reducing unnecessary energy consumption.
  • Restrooms: Restrooms in restaurants are ideal for ceiling occupancy sensors. These sensors can automatically control lighting based on occupancy, ensuring lights are not left on unnecessarily.
  • Storage and Utility Rooms: In storage and utility rooms, where occupancy is sporadic, wall occupancy/vacancy sensors can be installed. These sensors can automatically turn the lights on when someone enters the room and off when the room is vacant.
  • Manual Control: All lighting can be manually turned ON/OFF using the integrated controls in our occupancy/vacancy sensors. This provides flexibility for staff to control lighting based on specific needs or situations.

Wall Sensor Switches

RZ020/021 Motion Sensor Switches

  • 2-wire, 3-wire, 4-wires wiring options
  • Occupancy, Vacancy, Manual ON/OFF
  • Adjustive time delay and ambient light control

Multi-Location Wireless Wall Sensors

RZ020A/021A + RZ022W Kits

  • Hardwired RZ021A/022A occupancy sensor switch
  • Wireless companion switch (RZ022W) for multi-location control

Ceiling Occupancy Sensors

RZ036

  • Hardwired occupancy sensors
  • Auto ON, auto OFF
  • Line voltage and Low voltage available

Core features included:

  • Integrated manual ON/OFF control for all lighting
  • Vacancy sensors (Manual ON only): Lights must be turned on manually only
  • Adjustable time-delay, lighting is automatically turned full OFF after 15mins
  • Additional: multi-location wireless kits to expand the control range without re-wring
  • Additional: multiple wiring options available for both new constructions and retrofit projects.

Meets the Mandatory Provisions

IECC – 2011

C405.2.1 Occupant sensor controls

Occupant sensor controls shall be installed to control lights in the space.

C405.2.1.1 Occupant sensor control functions

  • Manual on or partial on to no more than 50% power.
  • Full off within 20 minutes after all occupants have left the space
  • A manual control to turn off the lights.

ASHRAE 90.1 – 2022

9.4.1.1 a Local control

There shall be one or more manual lighting control device that provides ON and OFF control
of all lighting in the space.

9.4.1.1 b Restricted to manual ON

None of the lighting shall be automatically turned on

9.4.1.1 c Restricted to partial automatic ON

No more than 50% of the lighting power for the general lighting shall be allowed to be automatically turned on

** NOTE: At least one 9.4.1.1 b or 9.4.1.1 c shall be implemented.

9.4.1.1 H Automatic full OFF control

All lighting in the space shall be automatically shut off within 20 minutes of all occupants leaving the space

Title 24 – 2022

130.1 (a) Manual area controls.

Each area enclosed by ceiling-height partitions shall provide lighting controls that allow the lighting in that area to be manually turned on and off.

130.1 (c) Shut-OFF Controls.

Lighting shall be controlled with occupant sensing controls to automatically shut OFF all of the lighting in 20 minutes or less after the control zone is unoccupied that shall function either as:

  • A. Occupant sensing controls (if 130.1(b) not required to have multi-level lighting controls); or
  • B. Partial-ON occupant sensing controls, or
  • C. Vacancy sensing controls, where all lighting responds to a manual ON input only