Classrooms
Discover the energy-saving potential of classrooms with Rayzeek’s occupancy sensor design guide. Learn how to meet energy code requirements while creating a more efficient learning environment.

Transforming Classrooms into Energy-Efficient Learning Spaces
Classrooms are dynamic spaces that serve as the foundation for learning and development. They are often filled with a variety of lighting fixtures, from overhead lights to task lighting, all of which contribute to a significant amount of energy consumption. The lighting in these spaces is typically left on for extended periods, even when the room is unoccupied, leading to unnecessary energy waste.
In a typical classroom, the lighting needs can vary greatly depending on the time of day, the activities taking place, and the number of occupants. This variability makes it challenging to manage lighting effectively and efficiently. As a result, there is a pressing need for solutions that can automatically control lighting based on occupancy, thereby reducing unnecessary energy consumption.
The need for energy conservation in classrooms is clear, and one of the most effective solutions is the use of occupancy sensors. These devices can automatically turn off lights when a room is vacant, significantly reducing energy consumption. With Rayzeek’s range of occupancy sensors, classrooms can become more energy-efficient, meeting the requirements of energy codes while also reducing operational costs.
Einhaltung der Energievorschriften

Der International Energy Conservation Code (IECC) ist ein Modellcode, der vom International Code Council (ICC) entwickelt wurde, um Mindestanforderungen an Entwurf und Bau für die Energieeffizienz von Gebäuden festzulegen. Der IECC wird alle drei Jahre aktualisiert, um die neuesten Praktiken und Technologien der Energiesparung zu berücksichtigen.
IECC: Warum es Sie interessieren sollte
Der IECC wird von den US-Bundesstaaten und Gemeinden weithin übernommen. Der IECC deckt verschiedene Aspekte des Energieverbrauchs ab, einschließlich der Gebäudehülle (Wände, Dächer und Fenster), Heiz- und Kühlsysteme sowie Beleuchtungssysteme.
Der IECC schreibt spezifische Beleuchtungssteuerungen vor, wie z. B. Belegungssensoren, um Energieverschwendung in unbesetzten Räumen in verschiedenen Bereichen zu minimieren.

ANSI/ASHRAE/IES Standard 90.1, Energienorm für Standorte und Gebäude mit Ausnahme von niedrigen Wohngebäuden, ist eine weithin anerkannte Energienorm, die von der American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) veröffentlicht wird.
ASHRAE 90.1: Warum es Sie interessieren sollte
ASHRAE 90.1 dient als Referenzwert für Gebäude-Energievorschriften in den gesamten USA und ist ein Konformitätsweg innerhalb des IECC, der Mindestanforderungen an die energieeffiziente Leistung von Komponenten gewerblicher Gebäude skizziert, einschließlich Gebäudehüllen, HLK-Systemen, Warmwassersystemen und Beleuchtungssystemen.
Die Norm ASHRAE 90.1 legt maximal zulässige Beleuchtungsleistungsdichten und Mindestanforderungen an die Beleuchtungssteuerung fest, einschließlich der Verwendung von Belegungssensoren in bestimmten Bereichen.

Title 24, Teil 6 des California Building Standards Code, offiziell bekannt als die Building Energy Efficiency Standards for Residential and Nonresidential Buildings (Gebäudeenergieeffizienzstandards für Wohn- und Nichtwohngebäude), wird von der California Energy Commission verwaltet und regelmäßig aktualisiert, um neue Energieeffizienztechnologien und -methoden widerzuspiegeln.
Title 24: Warum es Sie interessieren sollte
Title 24 ist für seine strengen Anforderungen bekannt, die oft als strenger angesehen werden als die vieler anderer Energievorschriften in den USA. Title 24 schreibt strenge Energiestandards für alle Aspekte des Gebäudebaus vor, einschließlich Heizung, Lüftung, Klimaanlage (HLK), Warmwasserbereitung und Beleuchtung.
Title 24 verlangt die Installation von Belegungssensoren, die die Beleuchtung basierend auf der Raumnutzung in bestimmten Bereichen gewerblicher Gebäude anpassen, um sicherzustellen, dass keine Energie verschwendet wird.
Übernahme der Energievorschriften nach Bundesstaat

Erweitern, um die detaillierte Tabelle anzuzeigen ↓
| Bundesstaat | Aktuelle Gewerbliche Vorschrift | Effizienzkategorie der Gewerblichen Vorschrift |
|---|---|---|
| Alabama | 90.1-2013 | 90.1-2013 |
| Alaska | Keine bundesstaatliche Vorschrift | Keine bundesstaatliche Vorschrift |
| Arizona | Home Rule | <90.1-2007 |
| Arkansas | 2009 IECC und 90.1-2007 | 90.1-2007 |
| Kalifornien | 2022 Building Energy Efficiency Standards | 90.1-2019 |
| Colorado | Home Rule | Keine bundesstaatliche Vorschrift |
| Connecticut | 2021 IECC und 90.1-2019 | 90.1-2019 |
| Delaware | 2018 IECC und 90.1-2016 | 90.1-2013 |
| District of Columbia | 90.1-2013^ | 90.1-2019 |
| Florida | 2021 IECC und 90.1-2019^ | 90.1-2016 |
| Georgia | 2015 IECC und 90.1-2013^ | 90.1-2013 |
| Hawaii | Home Rule | 90.1-2013 |
| Idaho | 2018 IECC und 90.1-2016 | 90.1-2013 |
| Illinois | 2021 IECC und 90.1-2019 | 90.1-2019 |
| Indiana | 90.1-2007 | 90.1-2007 |
| Iowa | 2012 IECC und 90.1-2010 | 90.1-2007 |
| Kansas | Home Rule | Keine bundesstaatliche Vorschrift |
| Kentucky | 2012 IECC und 90.1-2010 | 90.1-2007 |
| Louisiana | 2021 IECC und 90.1-2019^ | 90.1-2016 |
| Maine | 2015 IECC und 90.1-2013 | 90.1-2013 |
| Maryland | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Massachusetts | 2018 IECC und 90.1-2016^ | 90.1-2019 |
| Michigan | 2015 IECC und 90.1-2013^ | 90.1-2013 |
| Minnesota | 90.1-2019^ | 90.1-2019 |
| Mississippi | Keine bundesstaatliche Vorschrift | Keine bundesstaatliche Vorschrift |
| Missouri | Home Rule | Keine bundesstaatliche Vorschrift |
| Montana | 2021 IECC und 90.1-2019 | 90.1-2019 |
| Nebraska | 2018 IECC und 90.1-2016 | 90.1-2013 |
| Nevada | 2018 IECC und 90.1-2016 | 90.1-2013 |
| New Hampshire | 2018 IECC und 90.1-2016^ | 90.1-2013 |
| New Jersey | 90.1-2019 | 90.1-2019 |
| New Mexico | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| New York | 2018 IECC und 90.1-2016^ | 90.1-2016 |
| North Carolina | 2015 IECC und 90.1-2013^ | 90.1-2010 |
| North Dakota | Home Rule | Keine bundesstaatliche Vorschrift |
| Ohio | 2021 IECC und 90.1-2019^ | 90.1-2016 |
| Oklahoma | 2006 IECC und 90.1-2004 | <90.1-2007 |
| Oregon | 90.1-2019 | 90.1-2019 |
| Pennsylvania | 2018 IECC und 90.1-2016 | 90.1-2013 |
| Rhode Island | 2018 IECC und 90.1-2016^ | 90.1-2013 |
| South Carolina | 2009 IECC und 90.1-2007 | 90.1-2007 |
| South Dakota | Home Rule | Keine bundesstaatliche Vorschrift |
| Tennessee | 2021 IECC und 90.1-2013 | 90.1-2007 |
| Texas | 2015 IECC und 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Vermont | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Virginia | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Washington | Washington State Energiecode 2018 | 90.1-2019 |
| Tennessee | 2012 IECC und 90.1-2010 | 90.1-2007 |
| Texas | 2015 IECC und 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Vermont | 2018 IECC und 90.1-2016^ | 90.1-2019 |
| Virginia | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Washington | Washington State Energiecode 2018 | 90.1-2019 |
| West Virginia | 90.1-2013 | 90.1-2013 |
| Wisconsin | 2015 IECC und 90.1-2013^ | 90.1-2010 |
| Wyoming | Home Rule | Keine bundesstaatliche Vorschrift |
- ^ Wenn eine Änderung, die die Energieeffizienz beeinflusst, mit DOE-Prototypgebäudemodellen quantifiziert werden konnte, wurde sie in die Analyse einbezogen.
- Für Staaten, die sowohl den IECC als auch 90.1 annehmen, wird in dieser Studie in der Regel der IECC-Code als aktueller Code des Staates analysiert, mit Ausnahme von Staaten mit umfangreichen Änderungen am IECC.
Design Guide Key Concepts for Classrooms
Designing an energy-efficient lighting control solution for classrooms involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.

Designing an energy-efficient classroom with occupancy sensors involves careful planning and strategic placement of sensors:
- Wall Occupancy/Vacancy Sensors: Install these sensors near the main entrance of the classroom. These sensors can detect when someone enters or leaves the room, and can automatically turn the lights on or off accordingly. They can also be manually controlled to turn all lights on or off.
- Decken-Präsenzsensoren: These sensors should be installed in the center of the classroom, ensuring they have a clear view of the entire room to cover key areas such as the teacher’s desk, student desks, and any separate learning areas. They can detect any movement in the room, including minor movements such as students writing at their desks. When no movement is detected for a set period, the lights will automatically turn off.
- Additional Sensors for Specific Areas: If the classroom has specific areas such as a reading corner or a lab area, additional sensors may be needed. These sensors can control the lighting in these specific areas based on occupancy, ensuring that lights are not left on unnecessarily.
- Überlegungen zur Sensorplatzierung: Avoid placing sensors near air vents or other sources of movement that could trigger the sensor falsely. Also, ensure the sensors’ view is not obstructed by tall furniture or fixtures.
- Consideration of Natural Light: If the classroom has windows, the sensors should be programmed to consider the natural light coming into the room. This can help to further reduce energy consumption by utilizing natural light whenever possible.
- Integration with Manual Control: All occupancy/vacancy sensors should be integrated with manual controls. This allows teachers to manually turn off the lights during activities like video presentations, even if the room is occupied.
Ausgewählte Produkte & Lösungen
Kernfunktionen enthalten:
- Integrierte manuelle EIN/AUS-Steuerung für die gesamte Beleuchtung
- Abwesenheitssensoren (nur Manuell EIN): Lichter müssen nur manuell eingeschaltet werden
- Einstellbare Zeitverzögerung, die Beleuchtung wird nach 15 Minuten automatisch vollständig AUSgeschaltet
- Zusätzlich: kabellose Mehrfachpositionskits zur Erweiterung des Steuerungsbereichs ohne Neuverkabelung
- Zusätzlich: mehrere Verdrahtungsoptionen sowohl für Neubauten als auch für Nachrüstprojekte verfügbar.

Erfüllt die zwingenden Bestimmungen
IECC – 2011
C405.2.1 Personenensor-Steuerungen
Personensensor-Steuerungen sollen installiert werden, um die Beleuchtung im Raum zu steuern.
C405.2.1.1 Funktionen der Personensensor-Steuerung
- Manuell EIN oder Teil-EIN mit maximal 50% Leistung.
- Vollständiges AUS innerhalb von 20 Minuten nachdem alle Personen den Raum verlassen haben
- Eine manuelle Steuerung zum Ausschalten der Beleuchtung.
ASHRAE 90.1 – 2022
9.4.1.1 a Lokale Steuerung
Es muss ein oder mehrere manuelle Beleuchtungssteuerungsgeräte geben, die eine EIN- und AUS-Steuerung
der gesamten Beleuchtung im Raum ermöglichen.
9.4.1.1 b Beschränkt auf manuell EIN
Keine der Beleuchtung darf automatisch eingeschaltet werden
9.4.1.1 c Beschränkt auf teilautomatisches EINSCHALTEN
Es darf höchstens 50% der Beleuchtungsleistung für die Allgemeinbeleuchtung automatisch eingeschaltet werden
** HINWEIS: Mindestens eine der Anforderungen 9.4.1.1 b oder 9.4.1.1 c muss implementiert werden.
For classrooms except shop classrooms (all other classrooms/lecture halls/training rooms):
9.4.1.1 h Automatische vollständige AUSSCHALT-Steuerung
Die gesamte Beleuchtung im Raum muss innerhalb von 20 Minuten nach dem Verlassen des Raums durch alle Personen automatisch abgeschaltet werden
Title 24 – 2022
130.1 (a) Manuelle Bereichssteuerungen.
Jeder durch raumhohe Trennwände begrenzte Bereich muss Beleuchtungssteuerungen vorsehen, die es ermöglichen, die Beleuchtung in diesem Bereich manuell ein- und auszuschalten.
130.1 (c) Ausschalt-Steuerungen.
Die Beleuchtung muss mit Personen-anwesenheitssensor-Steuerungen gesteuert werden, um die gesamte Beleuchtung in 20 Minuten oder weniger automatisch AUSzuschalten, nachdem der Steuerungsbereich nicht mehr belegt ist, und zwar entweder als:
- A. Personen-anwesenheitssensor-Steuerungen (sofern 130.1(b) nicht die Mehrstufige Beleuchtungssteuerung erfordert); oder
- B. Teil-EIN Personen-anwesenheitssensor-Steuerungen, oder
- C. Anwesenheitserkennungs-Steuerungen, bei denen die gesamte Beleuchtung nur auf eine manuelle EINGABE reagiert
Lassen Sie uns von Ihnen hören.
Lassen Sie Rayzeek Ihnen bei der Planung und Bereitstellung einer maßgeschneiderten energiesparenden Beleuchtungslösung helfen.