Conference Rooms
Discover the energy-saving potential of your conference room with Rayzeek’s occupancy sensor design guide.

Maximize Energy Efficiency in Conference Rooms with Occupancy Sensors
Conference rooms are integral to the functioning of any commercial building, serving as the hub for meetings, presentations, and brainstorming sessions. These rooms are often equipped with high-intensity lighting to ensure visibility during presentations and discussions. However, due to their intermittent usage, they are prone to high energy wastage. Lights are often left on when the room is vacant, leading to unnecessary energy consumption.
Moreover, the sporadic usage of conference rooms means that they often remain vacant for extended periods, leading to unnecessary energy consumption if the lights are left on. This wastage not only impacts the building’s energy efficiency but also contributes to higher operational costs.
With Rayzeek’s occupancy sensors, you can transform your conference room into an energy-efficient space, meeting the requirements of energy codes and contributing to a greener environment.
Einhaltung der Energieeinsparverordnungen

Der International Energy Conservation Code (IECC) ist ein vom International Code Council (ICC) entwickelter Musterkodex zur Festlegung von Mindestanforderungen an die Energieeffizienz bei der Planung und dem Bau von Gebäuden. Der IECC wird alle drei Jahre aktualisiert, um die neuesten Verfahren und Technologien zur Energieeinsparung zu berücksichtigen.
IECC – Warum das Thema für Sie wichtig ist
Der IECC ist in vielen Bundesstaaten und Kommunen der Vereinigten Staaten weit verbreitet. Der IECC deckt verschiedene Aspekte der Energienutzung ab, darunter die Gebäudehülle (Wände, Dächer und Fenster), Heiz- und Kühlgesellschaften sowie Beleuchtungssysteme.
Der IECC schreibt spezifische Beleuchtungssteuerungen wie Präsenzmelder vor, um die Energieverschwendung in ungenutzten Räumen in verschiedenen Bereichen zu minimieren.

ANSI/ASHRAE/IES Standard 90.1, Energiestandard für Standorte und Gebäude außer wohnungsähnlichen Flachbauten, ist ein weit verbreiteter Energiestandard, der von der American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) herausgegeben wird.
ASHRAE 90.1 – Warum das für Sie wichtig ist
ASHRAE 90.1 dient in den Vereinigten Staaten als Maßstab für Energieeinsparverordnungen im Gebäudebereich und fungiert als Konformitätsweg innerhalb des IECC, der die Mindestanforderungen an die Energieeffizienz von Komponenten gewerblicher Gebäude – einschließlich Gebäudehüllen, HVAC-Systemen, Warmwasserbereitungsanlagen und Beleuchtungssystemen – festlegt.
Der Standard ASHRAE 90.1 legt die maximal zulässige Beleuchtungsleistungsdichte und die Mindestanforderungen an die Beleuchtungssteuerung fest, einschließlich des Einsatzes von Präsenzmeldern in bestimmten Bereichen.

Title 24, Teil 6 des California Building Standards Code, offiziell bekannt als Building Energy Efficiency Standards for Residential and Nonresidential Buildings, wird von der California Energy Commission verwaltet und regelmäßig aktualisiert, um neue Technologien und Methoden zur Energieeffizienz zu berücksichtigen.
Title 24 – Warum das für Sie wichtig ist
Title 24 ist für seine strengen Anforderungen bekannt, die oft als anspruchsvoller gelten als die vieler anderer Energieeinsparverordnungen in den Vereinigten Staaten. Title 24 schreibt strenge Energieeffizienzstandards für alle Aspekte des Hochbaus vor, einschließlich Heizung, Lüftung, Klima (HVAC), Warmwasserbereitung und Beleuchtung.
Title 24 erfordert die Installation von Präsenzmeldern, die die Beleuchtung je nach Raumbelegung in bestimmten Bereichen von Gewerbegebäuden anpassen, um sicherzustellen, dass keine Energie verschwendet wird.
Übernahme von Energieeinsparverordnungen nach Bundesstaat

Aufklappen, um die detaillierte Tabelle anzuzeigen ↓
| Bundesstaat | Aktuelle gewerbliche Bauvorschrift | Effizienzkategorie für gewerbliche Bauvorschriften |
|---|---|---|
| Alabama | 90.1-2013 | 90.1-2013 |
| Alaska | Keine bundeslandweite Regelung | Keine bundeslandweite Vorschrift |
| Arizona | Kommunale Selbstverwaltung | <90.1-2007 |
| Arkansas | 2009 IECC und 90.1-2007 | 90.1-2007 |
| Kalifornien | Building Energy Efficiency Standards 2022 | 90.1-2019 |
| Colorado | Kommunale Selbstverwaltung | Keine bundeslandweite Vorschrift |
| Connecticut | 2021 IECC und 90.1-2019 | 90.1-2019 |
| Delaware | 2018 IECC und 90.1-2016 | 90.1-2013 |
| District of Columbia | 90.1-2013^ | 90.1-2019 |
| Florida | 2021 IECC und 90.1-2019^ | 90.1-2016 |
| Georgia | 2015 IECC und 90.1-2013^ | 90.1-2013 |
| Hawaii | Kommunale Selbstverwaltung | 90.1-2013 |
| Idaho | 2018 IECC und 90.1-2016 | 90.1-2013 |
| Illinois | 2021 IECC und 90.1-2019 | 90.1-2019 |
| Indiana | 90.1-2007 | 90.1-2007 |
| Iowa | 2012 IECC und 90.1-2010 | 90.1-2007 |
| Kansas | Kommunale Selbstverwaltung | Keine bundeslandweite Vorschrift |
| Kentucky | 2012 IECC und 90.1-2010 | 90.1-2007 |
| Louisiana | 2021 IECC und 90.1-2019^ | 90.1-2016 |
| Maine | 2015 IECC und 90.1-2013 | 90.1-2013 |
| Maryland | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Massachusetts | 2018 IECC und 90.1-2016^ | 90.1-2019 |
| Michigan | 2015 IECC und 90.1-2013^ | 90.1-2013 |
| Minnesota | 90.1-2019^ | 90.1-2019 |
| Mississippi | Keine bundeslandweite Regelung | Keine bundeslandweite Vorschrift |
| Missouri | Kommunale Selbstverwaltung | Keine bundeslandweite Vorschrift |
| Montana | 2021 IECC und 90.1-2019 | 90.1-2019 |
| Nebraska | 2018 IECC und 90.1-2016 | 90.1-2013 |
| Nevada | 2018 IECC und 90.1-2016 | 90.1-2013 |
| New Hampshire | 2018 IECC und 90.1-2016^ | 90.1-2013 |
| New Jersey | 90.1-2019 | 90.1-2019 |
| New Mexico | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| New York | 2018 IECC und 90.1-2016^ | 90.1-2016 |
| North Carolina | 2015 IECC und 90.1-2013^ | 90.1-2010 |
| North Dakota | Kommunale Selbstverwaltung | Keine bundeslandweite Vorschrift |
| Ohio | 2021 IECC und 90.1-2019^ | 90.1-2016 |
| Oklahoma | 2006 IECC und 90.1-2004 | <90.1-2007 |
| Oregon | 90.1-2019 | 90.1-2019 |
| Pennsylvania | 2018 IECC und 90.1-2016 | 90.1-2013 |
| Rhode Island | 2018 IECC und 90.1-2016^ | 90.1-2013 |
| South Carolina | 2009 IECC und 90.1-2007 | 90.1-2007 |
| South Dakota | Kommunale Selbstverwaltung | Keine bundeslandweite Vorschrift |
| Tennessee | 2021 IECC und 90.1-2013 | 90.1-2007 |
| Texas | 2015 IECC und 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Vermont | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Virginia | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Washington | Energieeinsparverordnung des Staates Washington von 2018 | 90.1-2019 |
| Tennessee | 2012 IECC und 90.1-2010 | 90.1-2007 |
| Texas | 2015 IECC und 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Vermont | 2018 IECC und 90.1-2016^ | 90.1-2019 |
| Virginia | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Washington | Energieeinsparverordnung des Staates Washington von 2018 | 90.1-2019 |
| West Virginia | 90.1-2013 | 90.1-2013 |
| Wisconsin | 2015 IECC und 90.1-2013^ | 90.1-2010 |
| Wyoming | Kommunale Selbstverwaltung | Keine bundeslandweite Vorschrift |
- ^ Wenn eine Änderung mit Auswirkungen auf die Energieeffizienz mithilfe von DOE-Prototyp-Gebäudemodellen quantifiziert werden kann, wurde sie in die Analyse einbezogen.
- Für Staaten, die sowohl den IECC als auch 90.1 übernehmen, wird in dieser Studie in der Regel der IECC-Code als der aktuelle staatliche Code analysiert, außer in Staaten mit umfangreichen Änderungen am IECC.
Design Guide Key Concepts for Conference Rooms
Designing an energy-efficient lighting control solution for conference rooms involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.

Designing an energy-efficient lighting system for a conference room involves strategic placement of occupancy sensors to ensure comprehensive coverage. Here are some guidelines to consider:
- Abdeckung des Eingangsbereichs: Install a wall-mounted sensor near the entrance to detect when someone enters or exits the room. This sensor should be positioned high enough to avoid obstruction from the open door and should not directly face the entrance to avoid false triggers from movement outside the room.
- Table Coverage: Place a ceiling-mounted sensor above the conference table to detect occupancy in the main area of the room. This sensor should be positioned centrally to ensure comprehensive coverage.
- Presentation Area Coverage: If your conference room has a dedicated presentation area, consider installing an additional wall-mounted sensor to cover this space. This sensor should be positioned to avoid any potential obstructions, such as screens or projectors.
- Wall Control: Install a wall control unit near the entrance for manual override or adjustments of the lighting settings. This control should be easily accessible upon entering or exiting the room.
- Avoidance of Obstructions and Interference: Ensure that sensors are not placed near air vents to prevent interference from air flow or vibrations. Also, consider the height and placement of furniture to avoid blocking the sensor’s field of view.
- Integration with Existing Systems: Our occupancy sensors can be integrated with existing lighting systems for seamless operation. They can also be programmed to turn off all lights after a certain period of inactivity, further enhancing energy efficiency.
Empfohlene Produkte & Lösungen
Enthaltene Hauptfunktionen:
- Integrierte manuelle EIN/AUS-Steuerung für sämtliche Beleuchtungen
- Abwesenheitssensoren (nur manuelles Einschalten): Licht muss ausschließlich manuell eingeschaltet werden
- Einstellbare Zeitverzögerung, Beleuchtung wird nach 15 Minuten automatisch vollständig ausgeschaltet
- Zusätzlich: Drahtlose Mehrstellen-Sets zur Erweiterung des Steuerungsbereichs ohne Neuverdrahtung
- Zusätzlich: Mehrere Verdrahtungsoptionen für Neubauten und Nachrüstprojekte verfügbar.

Erfüllt die obligatorischen Bestimmungen
IECC – 2011
C405.2.1 Steuerungen durch Präsenzsensoren
Steuerungen durch Präsenzsensoren müssen installiert werden, um die Beleuchtung im Raum zu steuern.
C405.2.1.1 Funktionen der Präsenzsensorsteuerung
- Manuelles Einschalten oder teilweises Einschalten auf maximal 50% Leistung.
- Vollständiges Ausschalten innerhalb von 20 Minuten, nachdem alle Personen den Raum verlassen haben
- Eine manuelle Steuerung zum Ausschalten der Beleuchtung.
ASHRAE 90.1 – 2022
9.4.1.1 a Local control
There shall be one or more manual lighting control device that provides ON and OFF control
of all lighting in the space.
9.4.1.1 b Restricted to manual ON
None of the lighting shall be automatically turned on
9.4.1.1 c Restricted to partial automatic ON
No more than 50% of the lighting power for the general lighting shall be allowed to be automatically turned on
** NOTE: At least one 9.4.1.1 b or 9.4.1.1 c shall be implemented.
9.4.1.1 h Automatic full OFF control
Die gesamte Beleuchtung im Raum muss innerhalb von 20 Minuten, nachdem alle Personen den Raum verlassen haben, automatisch ausgeschaltet werden
Title 24 – 2022
130.1 (a) Manuelle Bereichssteuerungen.
Jeder durch deckenhohe Trennwände umschlossene Bereich muss mit Lichtsteuerungen ausgestattet sein, die ein manuelles Ein- und Ausschalten der Beleuchtung in diesem Bereich ermöglichen.
130.1 (c) Abschaltsteuerungen.
Die Beleuchtung muss mit Präsenzsteuerungen gesteuert werden, um die gesamte Beleuchtung innerhalb von 20 Minuten oder weniger, nachdem die Steuerzone unbelegt ist, automatisch AUSZUSCHALTEN, was wie folgt funktionieren muss:
- A. Präsenzsteuerungen (falls gemäß 130.1(b) keine mehrstufigen Beleuchtungssteuerungen erforderlich sind); oder
- B. Teil-EIN-Präsenzsteuerungen; oder
- C. Abwesenheitssteuerungen, bei denen die gesamte Beleuchtung nur auf ein manuelles EIN-Signal reagiert
Sprechen Sie mit uns.
Lassen Sie Rayzeek eine maßgeschneiderte, energieeffiziente Beleuchtungslösung für Sie entwickeln und umsetzen.