Discover energy-saving solutions for private offices with Rayzeek’s occupancy sensor design guide. Learn how to meet energy code requirements while optimizing lighting control for efficiency and comfort.

Optimize Energy Use in Private Offices with Smart Lighting Control
Private offices are individual workspaces, often enclosed by walls and a door, providing a quiet and focused environment for tasks that require concentration. These spaces are typically equipped with overhead lighting and task lighting, which can contribute significantly to the overall energy consumption of a commercial building.
Despite their benefits, private offices often face the issue of lights being left on when the space is unoccupied, leading to unnecessary energy waste. This is particularly problematic given that private offices are not continuously occupied throughout the day, with occupants often leaving for meetings, breaks, or other tasks.
To address this issue, occupancy sensors offer an effective solution. These devices can automatically turn off lights when the office is vacant, significantly reducing energy consumption. By integrating occupancy sensors into private offices, businesses can not only meet energy code requirements but also achieve substantial energy savings and improve their sustainability efforts.
Einhaltung der Energieeinsparverordnungen

Der International Energy Conservation Code (IECC) ist ein vom International Code Council (ICC) entwickelter Musterkodex zur Festlegung von Mindestanforderungen an die Energieeffizienz bei der Planung und dem Bau von Gebäuden. Der IECC wird alle drei Jahre aktualisiert, um die neuesten Verfahren und Technologien zur Energieeinsparung zu berücksichtigen.
IECC – Warum das Thema für Sie wichtig ist
Der IECC ist in vielen Bundesstaaten und Kommunen der Vereinigten Staaten weit verbreitet. Der IECC deckt verschiedene Aspekte der Energienutzung ab, darunter die Gebäudehülle (Wände, Dächer und Fenster), Heiz- und Kühlgesellschaften sowie Beleuchtungssysteme.
Der IECC schreibt spezifische Beleuchtungssteuerungen wie Präsenzmelder vor, um die Energieverschwendung in ungenutzten Räumen in verschiedenen Bereichen zu minimieren.

ANSI/ASHRAE/IES Standard 90.1, Energiestandard für Standorte und Gebäude außer wohnungsähnlichen Flachbauten, ist ein weit verbreiteter Energiestandard, der von der American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) herausgegeben wird.
ASHRAE 90.1 – Warum das für Sie wichtig ist
ASHRAE 90.1 dient in den Vereinigten Staaten als Maßstab für Energieeinsparverordnungen im Gebäudebereich und fungiert als Konformitätsweg innerhalb des IECC, der die Mindestanforderungen an die Energieeffizienz von Komponenten gewerblicher Gebäude – einschließlich Gebäudehüllen, HVAC-Systemen, Warmwasserbereitungsanlagen und Beleuchtungssystemen – festlegt.
Der Standard ASHRAE 90.1 legt die maximal zulässige Beleuchtungsleistungsdichte und die Mindestanforderungen an die Beleuchtungssteuerung fest, einschließlich des Einsatzes von Präsenzmeldern in bestimmten Bereichen.

Title 24, Teil 6 des California Building Standards Code, offiziell bekannt als Building Energy Efficiency Standards for Residential and Nonresidential Buildings, wird von der California Energy Commission verwaltet und regelmäßig aktualisiert, um neue Technologien und Methoden zur Energieeffizienz zu berücksichtigen.
Title 24 – Warum das für Sie wichtig ist
Title 24 ist für seine strengen Anforderungen bekannt, die oft als anspruchsvoller gelten als die vieler anderer Energieeinsparverordnungen in den Vereinigten Staaten. Title 24 schreibt strenge Energieeffizienzstandards für alle Aspekte des Hochbaus vor, einschließlich Heizung, Lüftung, Klima (HVAC), Warmwasserbereitung und Beleuchtung.
Title 24 erfordert die Installation von Präsenzmeldern, die die Beleuchtung je nach Raumbelegung in bestimmten Bereichen von Gewerbegebäuden anpassen, um sicherzustellen, dass keine Energie verschwendet wird.
Übernahme von Energieeinsparverordnungen nach Bundesstaat

Aufklappen, um die detaillierte Tabelle anzuzeigen ↓
| Bundesstaat | Aktuelle gewerbliche Bauvorschrift | Effizienzkategorie für gewerbliche Bauvorschriften |
|---|---|---|
| Alabama | 90.1-2013 | 90.1-2013 |
| Alaska | Keine bundeslandweite Regelung | Keine bundeslandweite Vorschrift |
| Arizona | Kommunale Selbstverwaltung | <90.1-2007 |
| Arkansas | 2009 IECC und 90.1-2007 | 90.1-2007 |
| Kalifornien | Building Energy Efficiency Standards 2022 | 90.1-2019 |
| Colorado | Kommunale Selbstverwaltung | Keine bundeslandweite Vorschrift |
| Connecticut | 2021 IECC und 90.1-2019 | 90.1-2019 |
| Delaware | 2018 IECC und 90.1-2016 | 90.1-2013 |
| District of Columbia | 90.1-2013^ | 90.1-2019 |
| Florida | 2021 IECC und 90.1-2019^ | 90.1-2016 |
| Georgia | 2015 IECC und 90.1-2013^ | 90.1-2013 |
| Hawaii | Kommunale Selbstverwaltung | 90.1-2013 |
| Idaho | 2018 IECC und 90.1-2016 | 90.1-2013 |
| Illinois | 2021 IECC und 90.1-2019 | 90.1-2019 |
| Indiana | 90.1-2007 | 90.1-2007 |
| Iowa | 2012 IECC und 90.1-2010 | 90.1-2007 |
| Kansas | Kommunale Selbstverwaltung | Keine bundeslandweite Vorschrift |
| Kentucky | 2012 IECC und 90.1-2010 | 90.1-2007 |
| Louisiana | 2021 IECC und 90.1-2019^ | 90.1-2016 |
| Maine | 2015 IECC und 90.1-2013 | 90.1-2013 |
| Maryland | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Massachusetts | 2018 IECC und 90.1-2016^ | 90.1-2019 |
| Michigan | 2015 IECC und 90.1-2013^ | 90.1-2013 |
| Minnesota | 90.1-2019^ | 90.1-2019 |
| Mississippi | Keine bundeslandweite Regelung | Keine bundeslandweite Vorschrift |
| Missouri | Kommunale Selbstverwaltung | Keine bundeslandweite Vorschrift |
| Montana | 2021 IECC und 90.1-2019 | 90.1-2019 |
| Nebraska | 2018 IECC und 90.1-2016 | 90.1-2013 |
| Nevada | 2018 IECC und 90.1-2016 | 90.1-2013 |
| New Hampshire | 2018 IECC und 90.1-2016^ | 90.1-2013 |
| New Jersey | 90.1-2019 | 90.1-2019 |
| New Mexico | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| New York | 2018 IECC und 90.1-2016^ | 90.1-2016 |
| North Carolina | 2015 IECC und 90.1-2013^ | 90.1-2010 |
| North Dakota | Kommunale Selbstverwaltung | Keine bundeslandweite Vorschrift |
| Ohio | 2021 IECC und 90.1-2019^ | 90.1-2016 |
| Oklahoma | 2006 IECC und 90.1-2004 | <90.1-2007 |
| Oregon | 90.1-2019 | 90.1-2019 |
| Pennsylvania | 2018 IECC und 90.1-2016 | 90.1-2013 |
| Rhode Island | 2018 IECC und 90.1-2016^ | 90.1-2013 |
| South Carolina | 2009 IECC und 90.1-2007 | 90.1-2007 |
| South Dakota | Kommunale Selbstverwaltung | Keine bundeslandweite Vorschrift |
| Tennessee | 2021 IECC und 90.1-2013 | 90.1-2007 |
| Texas | 2015 IECC und 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Vermont | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Virginia | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Washington | Energieeinsparverordnung des Staates Washington von 2018 | 90.1-2019 |
| Tennessee | 2012 IECC und 90.1-2010 | 90.1-2007 |
| Texas | 2015 IECC und 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Vermont | 2018 IECC und 90.1-2016^ | 90.1-2019 |
| Virginia | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Washington | Energieeinsparverordnung des Staates Washington von 2018 | 90.1-2019 |
| West Virginia | 90.1-2013 | 90.1-2013 |
| Wisconsin | 2015 IECC und 90.1-2013^ | 90.1-2010 |
| Wyoming | Kommunale Selbstverwaltung | Keine bundeslandweite Vorschrift |
- ^ Wenn eine Änderung mit Auswirkungen auf die Energieeffizienz mithilfe von DOE-Prototyp-Gebäudemodellen quantifiziert werden kann, wurde sie in die Analyse einbezogen.
- Für Staaten, die sowohl den IECC als auch 90.1 übernehmen, wird in dieser Studie in der Regel der IECC-Code als der aktuelle staatliche Code analysiert, außer in Staaten mit umfangreichen Änderungen am IECC.
Design Guide Key Concepts for Private Offices
Designing an energy-efficient lighting control solution for private offices involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.

- Sensor Placement: Position the sensor to cover the main areas of activity, such as the desk and the entrance. The sensor should have a clear line of sight to these areas, unobstructed by furniture or other objects. For private offices, wall-mounted sensors or ceiling-mounted sensors can be effective, depending on the room layout and furniture arrangement.
- Coverage of Minor Movements: Ensure that the desk area falls within the minor motion coverage area of the sensor. This means that even small movements, such as typing or turning pages in a book, should be detected by the sensor to prevent the lights from turning off while the space is occupied.
- Avoidance of Obstructions: If using wall-mounted sensors, ensure that tall furniture like bookcases does not block the sensor’s view of the room. Similarly, the sensor’s view should not be blocked by the door when it’s open.
- Abdeckung des Eingangsbereichs: The sensor should have a clear view of the entrance to detect occupancy as soon as someone enters the room. If the door blocks the sensor’s view when open, consider using an additional sensor to cover the entrance.
- Avoidance of Interference: Sensors should not be mounted close to air vents, as the vibration and air flow can reduce their effectiveness.
- Manuelle Steuerung: Incorporate manual controls for occupants to turn the lights ON/OFF as needed. These controls should be conveniently located, often near the entrance.
Empfohlene Produkte & Lösungen
Enthaltene Hauptfunktionen:
- Integrierte manuelle EIN/AUS-Steuerung für sämtliche Beleuchtungen
- Abwesenheitssensoren (nur manuelles Einschalten): Licht muss ausschließlich manuell eingeschaltet werden
- Einstellbare Zeitverzögerung, Beleuchtung wird nach 15 Minuten automatisch vollständig ausgeschaltet
- Zusätzlich: Drahtlose Mehrstellen-Sets zur Erweiterung des Steuerungsbereichs ohne Neuverdrahtung
- Zusätzlich: Mehrere Verdrahtungsoptionen für Neubauten und Nachrüstprojekte verfügbar.

Erfüllt die obligatorischen Bestimmungen
IECC – 2011
C405.2.1 Steuerungen durch Präsenzsensoren
Steuerungen durch Präsenzsensoren müssen installiert werden, um die Beleuchtung im Raum zu steuern.
For private/small offices <300 sq. ft:
C405.2.1.1 Funktionen der Präsenzsensorsteuerung
- Manuelles Einschalten oder teilweises Einschalten auf maximal 50% Leistung.
- Vollständiges Ausschalten innerhalb von 20 Minuten, nachdem alle Personen den Raum verlassen haben
- Eine manuelle Steuerung zum Ausschalten der Beleuchtung.
ASHRAE 90.1 – 2022
For private/small/enclosed offices <300 sq. ft:
9.4.1.1 a Local control
There shall be one or more manual lighting control device that provides ON and OFF control
of all lighting in the space.
9.4.1.1 b Restricted to manual ON
None of the lighting shall be automatically turned on
9.4.1.1 c Restricted to partial automatic ON
No more than 50% of the lighting power for the general lighting shall be allowed to be automatically turned on
** NOTE: At least one 9.4.1.1 b or 9.4.1.1 c shall be implemented.
9.4.1.1 H Automatische vollständige AUS-Steuerung
Die gesamte Beleuchtung im Raum muss innerhalb von 20 Minuten, nachdem alle Personen den Raum verlassen haben, automatisch ausgeschaltet werden
Title 24 – 2022
For private/small offices <250 sq. ft:
130.1 (a) Manuelle Bereichssteuerungen.
Jeder durch deckenhohe Trennwände umschlossene Bereich muss mit Lichtsteuerungen ausgestattet sein, die ein manuelles Ein- und Ausschalten der Beleuchtung in diesem Bereich ermöglichen.
130.1 (c) Abschaltsteuerungen.
Die Beleuchtung muss mit Präsenzsteuerungen gesteuert werden, um die gesamte Beleuchtung innerhalb von 20 Minuten oder weniger, nachdem die Steuerzone unbelegt ist, automatisch AUSZUSCHALTEN, was wie folgt funktionieren muss:
- A. Präsenzsteuerungen (falls gemäß 130.1(b) keine mehrstufigen Beleuchtungssteuerungen erforderlich sind); oder
- B. Teil-EIN-Präsenzsteuerungen; oder
- C. Abwesenheitssteuerungen, bei denen die gesamte Beleuchtung nur auf ein manuelles EIN-Signal reagiert