Discover the energy-saving potential of corridors with Rayzeek’s occupancy sensor design guide. Uncover the power of automated lighting control in your commercial building’s passageways.

Lighting the Way to Energy Efficiency in Corridors
Corridors, whether in commercial buildings, educational institutions, or healthcare facilities, are high-traffic areas that often remain illuminated throughout the day, leading to significant energy consumption. These spaces typically use fluorescent or LED lighting, which, while energy-efficient, can still contribute to high energy costs when left on unnecessarily.
The challenge lies in the fact that corridors are intermittently occupied, with periods of high foot traffic interspersed with times of vacancy. Traditional manual lighting controls can lead to lights being left on during these vacant periods, resulting in unnecessary energy waste.
By integrating our occupancy sensors into your corridor lighting system, you can ensure that lights are only on when needed, saving energy and reducing costs. Our sensors, including wall and ceiling-mounted options, are designed to comply with US Energy Codes, making them an essential component in meeting energy efficiency requirements for commercial buildings.
Einhaltung der Energieeinsparverordnungen

Der International Energy Conservation Code (IECC) ist ein vom International Code Council (ICC) entwickelter Musterkodex zur Festlegung von Mindestanforderungen an die Energieeffizienz bei der Planung und dem Bau von Gebäuden. Der IECC wird alle drei Jahre aktualisiert, um die neuesten Verfahren und Technologien zur Energieeinsparung zu berücksichtigen.
IECC – Warum das Thema für Sie wichtig ist
Der IECC ist in vielen Bundesstaaten und Kommunen der Vereinigten Staaten weit verbreitet. Der IECC deckt verschiedene Aspekte der Energienutzung ab, darunter die Gebäudehülle (Wände, Dächer und Fenster), Heiz- und Kühlgesellschaften sowie Beleuchtungssysteme.
Der IECC schreibt spezifische Beleuchtungssteuerungen wie Präsenzmelder vor, um die Energieverschwendung in ungenutzten Räumen in verschiedenen Bereichen zu minimieren.

ANSI/ASHRAE/IES Standard 90.1, Energiestandard für Standorte und Gebäude außer wohnungsähnlichen Flachbauten, ist ein weit verbreiteter Energiestandard, der von der American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) herausgegeben wird.
ASHRAE 90.1 – Warum das für Sie wichtig ist
ASHRAE 90.1 dient in den Vereinigten Staaten als Maßstab für Energieeinsparverordnungen im Gebäudebereich und fungiert als Konformitätsweg innerhalb des IECC, der die Mindestanforderungen an die Energieeffizienz von Komponenten gewerblicher Gebäude – einschließlich Gebäudehüllen, HVAC-Systemen, Warmwasserbereitungsanlagen und Beleuchtungssystemen – festlegt.
Der Standard ASHRAE 90.1 legt die maximal zulässige Beleuchtungsleistungsdichte und die Mindestanforderungen an die Beleuchtungssteuerung fest, einschließlich des Einsatzes von Präsenzmeldern in bestimmten Bereichen.

Title 24, Teil 6 des California Building Standards Code, offiziell bekannt als Building Energy Efficiency Standards for Residential and Nonresidential Buildings, wird von der California Energy Commission verwaltet und regelmäßig aktualisiert, um neue Technologien und Methoden zur Energieeffizienz zu berücksichtigen.
Title 24 – Warum das für Sie wichtig ist
Title 24 ist für seine strengen Anforderungen bekannt, die oft als anspruchsvoller gelten als die vieler anderer Energieeinsparverordnungen in den Vereinigten Staaten. Title 24 schreibt strenge Energieeffizienzstandards für alle Aspekte des Hochbaus vor, einschließlich Heizung, Lüftung, Klima (HVAC), Warmwasserbereitung und Beleuchtung.
Title 24 erfordert die Installation von Präsenzmeldern, die die Beleuchtung je nach Raumbelegung in bestimmten Bereichen von Gewerbegebäuden anpassen, um sicherzustellen, dass keine Energie verschwendet wird.
Übernahme von Energieeinsparverordnungen nach Bundesstaat

Aufklappen, um die detaillierte Tabelle anzuzeigen ↓
| Bundesstaat | Aktuelle gewerbliche Bauvorschrift | Effizienzkategorie für gewerbliche Bauvorschriften |
|---|---|---|
| Alabama | 90.1-2013 | 90.1-2013 |
| Alaska | Keine bundeslandweite Regelung | Keine bundeslandweite Vorschrift |
| Arizona | Kommunale Selbstverwaltung | <90.1-2007 |
| Arkansas | 2009 IECC und 90.1-2007 | 90.1-2007 |
| Kalifornien | Building Energy Efficiency Standards 2022 | 90.1-2019 |
| Colorado | Kommunale Selbstverwaltung | Keine bundeslandweite Vorschrift |
| Connecticut | 2021 IECC und 90.1-2019 | 90.1-2019 |
| Delaware | 2018 IECC und 90.1-2016 | 90.1-2013 |
| District of Columbia | 90.1-2013^ | 90.1-2019 |
| Florida | 2021 IECC und 90.1-2019^ | 90.1-2016 |
| Georgia | 2015 IECC und 90.1-2013^ | 90.1-2013 |
| Hawaii | Kommunale Selbstverwaltung | 90.1-2013 |
| Idaho | 2018 IECC und 90.1-2016 | 90.1-2013 |
| Illinois | 2021 IECC und 90.1-2019 | 90.1-2019 |
| Indiana | 90.1-2007 | 90.1-2007 |
| Iowa | 2012 IECC und 90.1-2010 | 90.1-2007 |
| Kansas | Kommunale Selbstverwaltung | Keine bundeslandweite Vorschrift |
| Kentucky | 2012 IECC und 90.1-2010 | 90.1-2007 |
| Louisiana | 2021 IECC und 90.1-2019^ | 90.1-2016 |
| Maine | 2015 IECC und 90.1-2013 | 90.1-2013 |
| Maryland | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Massachusetts | 2018 IECC und 90.1-2016^ | 90.1-2019 |
| Michigan | 2015 IECC und 90.1-2013^ | 90.1-2013 |
| Minnesota | 90.1-2019^ | 90.1-2019 |
| Mississippi | Keine bundeslandweite Regelung | Keine bundeslandweite Vorschrift |
| Missouri | Kommunale Selbstverwaltung | Keine bundeslandweite Vorschrift |
| Montana | 2021 IECC und 90.1-2019 | 90.1-2019 |
| Nebraska | 2018 IECC und 90.1-2016 | 90.1-2013 |
| Nevada | 2018 IECC und 90.1-2016 | 90.1-2013 |
| New Hampshire | 2018 IECC und 90.1-2016^ | 90.1-2013 |
| New Jersey | 90.1-2019 | 90.1-2019 |
| New Mexico | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| New York | 2018 IECC und 90.1-2016^ | 90.1-2016 |
| North Carolina | 2015 IECC und 90.1-2013^ | 90.1-2010 |
| North Dakota | Kommunale Selbstverwaltung | Keine bundeslandweite Vorschrift |
| Ohio | 2021 IECC und 90.1-2019^ | 90.1-2016 |
| Oklahoma | 2006 IECC und 90.1-2004 | <90.1-2007 |
| Oregon | 90.1-2019 | 90.1-2019 |
| Pennsylvania | 2018 IECC und 90.1-2016 | 90.1-2013 |
| Rhode Island | 2018 IECC und 90.1-2016^ | 90.1-2013 |
| South Carolina | 2009 IECC und 90.1-2007 | 90.1-2007 |
| South Dakota | Kommunale Selbstverwaltung | Keine bundeslandweite Vorschrift |
| Tennessee | 2021 IECC und 90.1-2013 | 90.1-2007 |
| Texas | 2015 IECC und 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Vermont | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Virginia | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Washington | Energieeinsparverordnung des Staates Washington von 2018 | 90.1-2019 |
| Tennessee | 2012 IECC und 90.1-2010 | 90.1-2007 |
| Texas | 2015 IECC und 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Vermont | 2018 IECC und 90.1-2016^ | 90.1-2019 |
| Virginia | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Washington | Energieeinsparverordnung des Staates Washington von 2018 | 90.1-2019 |
| West Virginia | 90.1-2013 | 90.1-2013 |
| Wisconsin | 2015 IECC und 90.1-2013^ | 90.1-2010 |
| Wyoming | Kommunale Selbstverwaltung | Keine bundeslandweite Vorschrift |
- ^ Wenn eine Änderung mit Auswirkungen auf die Energieeffizienz mithilfe von DOE-Prototyp-Gebäudemodellen quantifiziert werden kann, wurde sie in die Analyse einbezogen.
- Für Staaten, die sowohl den IECC als auch 90.1 übernehmen, wird in dieser Studie in der Regel der IECC-Code als der aktuelle staatliche Code analysiert, außer in Staaten mit umfangreichen Änderungen am IECC.
Design Guide Key Concepts for Corridors
Designing an energy-efficient lighting control solution for corridors involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.

In a corridor, the primary goal is to ensure safe and well-lit passage for occupants while minimizing energy waste and all potential access points and the entire length of the corridor are covered by the sensors. Here are some design considerations:
- Sensor Placement: For long corridors, multiple sensors may be required. Ceiling-mounted sensors can be placed at regular intervals along the length of the corridor to ensure comprehensive coverage. Alternatively, wall-mounted sensors can be placed at both ends of the corridor, with their coverage areas overlapping in the middle to avoid any blind spots. Also, consider the height and range of the sensors to ensure they can effectively detect movement across the entire corridor.
- Sensor Type: Depending on the ceiling height and the presence of any potential obstructions, either ceiling-mounted or wall-mounted sensors can be used. Rayzeek’s ceiling sensors offer automatic ON and full OFF functionality, while our wall sensors provide manual ON and full OFF functionality.
- Additional Manual Controls: In addition to occupancy sensors, manual controls can be integrated for instances where manual override is necessary. These controls can be conveniently located near entrances or exits.
- Avoiding False Triggers: Sensors should be placed such that they do not directly face doors leading to other spaces, external light sources and air vents, as this could lead to false triggers when movement is detected in these adjacent spaces.
Empfohlene Produkte & Lösungen
Enthaltene Hauptfunktionen:
- Integrierte manuelle EIN/AUS-Steuerung für sämtliche Beleuchtungen
- Abwesenheitssensoren (nur manuelles Einschalten): Licht muss ausschließlich manuell eingeschaltet werden
- Einstellbare Zeitverzögerung, Beleuchtung wird nach 15 Minuten automatisch vollständig ausgeschaltet
- Zusätzlich: Drahtlose Mehrstellen-Sets zur Erweiterung des Steuerungsbereichs ohne Neuverdrahtung
- Zusätzlich: Mehrere Verdrahtungsoptionen für Neubauten und Nachrüstprojekte verfügbar.

Erfüllt die obligatorischen Bestimmungen
IECC – 2011
C405.2.1 Steuerungen durch Präsenzsensoren
Steuerungen durch Präsenzsensoren müssen installiert werden, um die Beleuchtung im Raum zu steuern.
C405.2.1.1 Funktionen der Präsenzsensorsteuerung
- Manuelles Einschalten oder teilweises Einschalten auf maximal 50% Leistung.
- Vollständiges Ausschalten innerhalb von 20 Minuten, nachdem alle Personen den Raum verlassen haben
- Eine manuelle Steuerung zum Ausschalten der Beleuchtung.
Full automatic-on controls with no manual control are permitted in corridors where manual operation would endanger occupant safety or security.
C405.2.1.4 Occupant sensor control function in corridors.
Occupant sensor controls in corridors shall uniformly reduce lighting power to an occupied setpoint not more than 50 percent offull power within 20 minutes after all occupants have left the space.
Exception: Corridors provided with less than two footcandles of illumination on the floor at the darkest point with all lights on.
ASHRAE 90.1 – 2022
9.4.1.1 a Local control
There shall be one or more manual lighting control device that provides ON and OFF control
of all lighting in the space.
9.4.1.1 g Automatic reduction control
The general lighting power in the space shall be automatically reduced by at least 50% within 15 minutes of all occupants leaving the space.
9.4.1.1 h Automatic full OFF control
All lighting in the space shall be automatically shut off within 15 minutes of all occupants leaving the space.
9.4.1.1 i Scheduled shutoff
All lighting in the space shall be automatically shut off during periods when the space is scheduled to be unoccupied.
** NOTE: At least one 9.4.1.1 h or 9.4.1.1 i shall be implemented.
Title 24 – 2022
130.1 (a) Manuelle Bereichssteuerungen.
Jeder durch deckenhohe Trennwände umschlossene Bereich muss mit Lichtsteuerungen ausgestattet sein, die ein manuelles Ein- und Ausschalten der Beleuchtung in diesem Bereich ermöglichen.
130.1 (c) Abschaltsteuerungen.
In corridors, lighting shall be controlled by Full or partial-OFF occupant sensing controls that separately reduce the lighting power in each space by at least 50 percent when the space is unoccupied. The occupant sensing controls shall be capable of automatically turning the lighting fully ON only in the separately controlled space, and shall be automatically activated from all designed paths of egress.
Sprechen Sie mit uns.
Lassen Sie Rayzeek eine maßgeschneiderte, energieeffiziente Beleuchtungslösung für Sie entwickeln und umsetzen.