Discover the energy-saving potential of classrooms with Rayzeek’s occupancy sensor design guide. Learn how to meet energy code requirements while creating a more efficient learning environment.

Transforming Classrooms into Energy-Efficient Learning Spaces
Classrooms are dynamic spaces that serve as the foundation for learning and development. They are often filled with a variety of lighting fixtures, from overhead lights to task lighting, all of which contribute to a significant amount of energy consumption. The lighting in these spaces is typically left on for extended periods, even when the room is unoccupied, leading to unnecessary energy waste.
In a typical classroom, the lighting needs can vary greatly depending on the time of day, the activities taking place, and the number of occupants. This variability makes it challenging to manage lighting effectively and efficiently. As a result, there is a pressing need for solutions that can automatically control lighting based on occupancy, thereby reducing unnecessary energy consumption.
The need for energy conservation in classrooms is clear, and one of the most effective solutions is the use of occupancy sensors. These devices can automatically turn off lights when a room is vacant, significantly reducing energy consumption. With Rayzeek’s range of occupancy sensors, classrooms can become more energy-efficient, meeting the requirements of energy codes while also reducing operational costs.
에너지 코드 준수

국제에너지보존코드(IECC)는 건물 에너지 효율성을 위한 최소 설계 및 시공 요구사항을 규정하기 위해 ICC(International Code Council)에서 개발한 모델 코드입니다. IECC는 최신 에너지 절약 실천법과 기술을 반영하기 위해 3년마다 개정됩니다.
IECC를 주목해야 하는 이유
IECC는 미국 전역의 주 및 지방 자치 단체에서 널리 채택되고 있습니다. IECC는 건물 외피(벽, 지붕, 창호), 난방 및 냉방 시스템, 조명 시스템을 포함한 에너지 사용의 다양한 측면을 다룹니다.
IECC는 다양한 구역의 빈 공간에서 발생하는 에너지 낭비를 최소화하기 위해 점유 감지 센서와 같은 특정 조명 제어 장치의 설치를 의무화합니다.

ANSI/ASHRAE/IES Standard 90.1(저층 주거용 건물을 제외한 부지 및 건물의 에너지 표준)은 미국냉난방공조학회(ASHRAE)에서 발행하는 광범위하게 인정받는 에너지 표준입니다.
ASHRAE 90.1을 주목해야 하는 이유
ASHRAE 90.1은 미국 전역의 건물 에너지 코드의 기준 표준으로 사용되며, 건물 외피, HVAC 시스템, 급탕 시스템, 조명 시스템을 포함한 상업용 건물 구성 요소의 에너지 효율적 성능에 대한 최소 요구사항을 개괄하는 IECC 내 준수 경로 역할을 합니다.
ASHRAE 90.1 표준은 최대 허용 조명 전력 밀도 및 특정 구역에서의 점유 감지 센서 사용을 포함한 최소 조명 제어 요구사항을 규정합니다.

캘리포니아 건물 표준법 Part 6의 Title 24(공식 명칭: 주거용 및 비주거용 건물 에너지 효율성 표준)는 캘리포니아 에너지 위원회(CEC)에서 관리하며, 새로운 에너지 효율 기술과 방법을 반영하기 위해 주기적으로 업데이트됩니다.
Title 24를 주목해야 하는 이유
Title 24는 미국 내 다른 수많은 에너지 코드보다 더욱 엄격한 요구사항을 가진 것으로 잘 알려져 있습니다. Title 24는 난방, 환기, 공조(HVAC), 급탕, 조명을 포함한 건물 건설의 모든 측면에 대해 엄격한 에너지 성능 표준을 준수하도록 규정합니다.
Title 24는 에너지가 낭비되지 않도록 상업용 건물의 특정 구역에서 재실 여부에 따라 조명을 조절하는 점유 감지 센서 설치를 의무화합니다.
주별 에너지 코드 채택 현황

상세 표를 보려면 펼치기 ↓
| 주(State) | 현행 상업용 건축 기준 | 상업용 건축 기준 에너지 효율 카테고리 |
|---|---|---|
| 앨라배마 | 90.1-2013 | 90.1-2013 |
| 알래스카 | 주 전체 기준 없음 | 주 전체 건축 기준 없음 |
| 애리조나 | 자치 도시 규정 적용(Home rule) | <90.1-2007 |
| 아칸소 | 2009 IECC 및 90.1-2007 | 90.1-2007 |
| 캘리포니아 | 2022년 건물 에너지 효율 기준 | 90.1-2019 |
| 콜로라도 | 자치 도시 규정 적용(Home rule) | 주 전체 건축 기준 없음 |
| 코네티컷 | 2021 IECC 및 90.1-2019 | 90.1-2019 |
| 델라웨어 | 2018 IECC 및 90.1-2016 | 90.1-2013 |
| 컬럼비아 특별구 | 90.1-2013^ | 90.1-2019 |
| 플로리다 | 2021 IECC 및 90.1-2019^ | 90.1-2016 |
| 조지아 | 2015 IECC 및 90.1-2013^ | 90.1-2013 |
| 하와이 | 자치 도시 규정 적용(Home rule) | 90.1-2013 |
| 아이다호 | 2018 IECC 및 90.1-2016 | 90.1-2013 |
| 일리노이 | 2021 IECC 및 90.1-2019 | 90.1-2019 |
| 인디애나 | 90.1-2007 | 90.1-2007 |
| 아이오와 | 2012 IECC 및 90.1-2010 | 90.1-2007 |
| 캔자스 | 자치 도시 규정 적용(Home rule) | 주 전체 건축 기준 없음 |
| 켄터키 | 2012 IECC 및 90.1-2010 | 90.1-2007 |
| 루이지애나 | 2021 IECC 및 90.1-2019^ | 90.1-2016 |
| 메인 | 2015 IECC 및 90.1-2013 | 90.1-2013 |
| 메릴랜드 | 2021 IECC 및 90.1-2019^ | 90.1-2019 |
| 매사추세츠 | 2018 IECC 및 90.1-2016^ | 90.1-2019 |
| 미시간 | 2015 IECC 및 90.1-2013^ | 90.1-2013 |
| 미네소타 | 90.1-2019^ | 90.1-2019 |
| 미시시피 | 주 전체 기준 없음 | 주 전체 건축 기준 없음 |
| 미주리 | 자치 도시 규정 적용(Home rule) | 주 전체 건축 기준 없음 |
| 몬태나 | 2021 IECC 및 90.1-2019 | 90.1-2019 |
| 네브래스카 | 2018 IECC 및 90.1-2016 | 90.1-2013 |
| 네바다 | 2018 IECC 및 90.1-2016 | 90.1-2013 |
| 뉴햄프셔 | 2018 IECC 및 90.1-2016^ | 90.1-2013 |
| 뉴저지 | 90.1-2019 | 90.1-2019 |
| 뉴멕시코 | 2021 IECC 및 90.1-2019^ | 90.1-2019 |
| 뉴욕 | 2018 IECC 및 90.1-2016^ | 90.1-2016 |
| 노스캐롤라이나 | 2015 IECC 및 90.1-2013^ | 90.1-2010 |
| 노스다코타 | 자치 도시 규정 적용(Home rule) | 주 전체 건축 기준 없음 |
| 오하이오 | 2021 IECC 및 90.1-2019^ | 90.1-2016 |
| 오클라호마 | 2006 IECC 및 90.1-2004 | <90.1-2007 |
| 오레곤 | 90.1-2019 | 90.1-2019 |
| 펜실베이니아 | 2018 IECC 및 90.1-2016 | 90.1-2013 |
| 로드아일랜드 | 2018 IECC 및 90.1-2016^ | 90.1-2013 |
| 사우스캐롤라이나 | 2009 IECC 및 90.1-2007 | 90.1-2007 |
| 사우스다코타 | 자치 도시 규정 적용(Home rule) | 주 전체 건축 기준 없음 |
| 테네시 | 2021 IECC 및 90.1-2013 | 90.1-2007 |
| 텍사스 | 2015 IECC 및 90.1-2013 | 90.1-2013 |
| 유타 | 2021 IECC 및 90.1-2019^ | 90.1-2019 |
| 버몬트 | 2021 IECC 및 90.1-2019^ | 90.1-2019 |
| 버기니아 | 2021 IECC 및 90.1-2019^ | 90.1-2019 |
| 워싱턴 | 2018년 워싱턴주 에너지 코드 | 90.1-2019 |
| 테네시 | 2012 IECC 및 90.1-2010 | 90.1-2007 |
| 텍사스 | 2015 IECC 및 90.1-2013 | 90.1-2013 |
| 유타 | 2021 IECC 및 90.1-2019^ | 90.1-2019 |
| 버몬트 | 2018 IECC 및 90.1-2016^ | 90.1-2019 |
| 버기니아 | 2021 IECC 및 90.1-2019^ | 90.1-2019 |
| 워싱턴 | 2018년 워싱턴주 에너지 코드 | 90.1-2019 |
| 웨스트버지니아주 | 90.1-2013 | 90.1-2013 |
| 위스콘신주 | 2015 IECC 및 90.1-2013^ | 90.1-2010 |
| 와이오밍주 | 자치 도시 규정 적용(Home rule) | 주 전체 건축 기준 없음 |
- ^ 에너지 효율에 영향을 미치는 개정안을 DOE 프로토타입 건물 모델을 사용하여 정량화할 수 있는 경우, 해당 개정안은 분석에 반영되었습니다.
- IECC와 90.1을 모두 채택하는 주의 경우, IECC 코드에 광범위한 개정안이 있는 주를 제외하고는 본 연구에서 일반적으로 IECC 코드를 주의 현행 코드로 분석합니다.
Design Guide Key Concepts for Classrooms
Designing an energy-efficient lighting control solution for classrooms involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.

Designing an energy-efficient classroom with occupancy sensors involves careful planning and strategic placement of sensors:
- Wall Occupancy/Vacancy Sensors: Install these sensors near the main entrance of the classroom. These sensors can detect when someone enters or leaves the room, and can automatically turn the lights on or off accordingly. They can also be manually controlled to turn all lights on or off.
- Ceiling Occupancy Sensors: These sensors should be installed in the center of the classroom, ensuring they have a clear view of the entire room to cover key areas such as the teacher’s desk, student desks, and any separate learning areas. They can detect any movement in the room, including minor movements such as students writing at their desks. When no movement is detected for a set period, the lights will automatically turn off.
- Additional Sensors for Specific Areas: If the classroom has specific areas such as a reading corner or a lab area, additional sensors may be needed. These sensors can control the lighting in these specific areas based on occupancy, ensuring that lights are not left on unnecessarily.
- 센서 배치 시 고려 사항: Avoid placing sensors near air vents or other sources of movement that could trigger the sensor falsely. Also, ensure the sensors’ view is not obstructed by tall furniture or fixtures.
- Consideration of Natural Light: If the classroom has windows, the sensors should be programmed to consider the natural light coming into the room. This can help to further reduce energy consumption by utilizing natural light whenever possible.
- Integration with Manual Control: All occupancy/vacancy sensors should be integrated with manual controls. This allows teachers to manually turn off the lights during activities like video presentations, even if the room is occupied.
주요 제품 및 솔루션
Core features included:
- Integrated manual ON/OFF control for all lighting
- Vacancy sensors (Manual ON only): Lights must be turned on manually only
- Adjustable time-delay, lighting is automatically turned full OFF after 15mins
- Additional: multi-location wireless kits to expand the control range without re-wring
- Additional: multiple wiring options available for both new constructions and retrofit projects.

Meets the Mandatory Provisions
IECC – 2011
C405.2.1 Occupant sensor controls
Occupant sensor controls shall be installed to control lights in the space.
C405.2.1.1 Occupant sensor control functions
- Manual on or partial on to no more than 50% power.
- Full off within 20 minutes after all occupants have left the space
- A manual control to turn off the lights.
ASHRAE 90.1 – 2022
9.4.1.1 a Local control
There shall be one or more manual lighting control device that provides ON and OFF control
of all lighting in the space.
9.4.1.1 b Restricted to manual ON
None of the lighting shall be automatically turned on
9.4.1.1 c Restricted to partial automatic ON
No more than 50% of the lighting power for the general lighting shall be allowed to be automatically turned on
** NOTE: At least one 9.4.1.1 b or 9.4.1.1 c shall be implemented.
For classrooms except shop classrooms (all other classrooms/lecture halls/training rooms):
9.4.1.1 h Automatic full OFF control
All lighting in the space shall be automatically shut off within 20 minutes of all occupants leaving the space
Title 24 – 2022
130.1 (a) Manual area controls.
Each area enclosed by ceiling-height partitions shall provide lighting controls that allow the lighting in that area to be manually turned on and off.
130.1 (c) Shut-OFF Controls.
Lighting shall be controlled with occupant sensing controls to automatically shut OFF all of the lighting in 20 minutes or less after the control zone is unoccupied that shall function either as:
- A. Occupant sensing controls (if 130.1(b) not required to have multi-level lighting controls); or
- B. Partial-ON occupant sensing controls, or
- C. Vacancy sensing controls, where all lighting responds to a manual ON input only
Let us hear you.