Classrooms

Discover the energy-saving potential of classrooms with Rayzeek’s occupancy sensor design guide. Learn how to meet energy code requirements while creating a more efficient learning environment.

Transforming Classrooms into Energy-Efficient Learning Spaces

Classrooms are dynamic spaces that serve as the foundation for learning and development. They are often filled with a variety of lighting fixtures, from overhead lights to task lighting, all of which contribute to a significant amount of energy consumption. The lighting in these spaces is typically left on for extended periods, even when the room is unoccupied, leading to unnecessary energy waste.

In a typical classroom, the lighting needs can vary greatly depending on the time of day, the activities taking place, and the number of occupants. This variability makes it challenging to manage lighting effectively and efficiently. As a result, there is a pressing need for solutions that can automatically control lighting based on occupancy, thereby reducing unnecessary energy consumption.

The need for energy conservation in classrooms is clear, and one of the most effective solutions is the use of occupancy sensors. These devices can automatically turn off lights when a room is vacant, significantly reducing energy consumption. With Rayzeek’s range of occupancy sensors, classrooms can become more energy-efficient, meeting the requirements of energy codes while also reducing operational costs.

에너지 코드 준수

국제에너지보존코드(IECC)는 건물 에너지 효율성을 위한 최소 설계 및 시공 요구사항을 규정하기 위해 ICC(International Code Council)에서 개발한 모델 코드입니다. IECC는 최신 에너지 절약 실천법과 기술을 반영하기 위해 3년마다 개정됩니다.

IECC를 주목해야 하는 이유

IECC는 미국 전역의 주 및 지방 자치 단체에서 널리 채택되고 있습니다. IECC는 건물 외피(벽, 지붕, 창호), 난방 및 냉방 시스템, 조명 시스템을 포함한 에너지 사용의 다양한 측면을 다룹니다.

IECC는 다양한 구역의 빈 공간에서 발생하는 에너지 낭비를 최소화하기 위해 점유 감지 센서와 같은 특정 조명 제어 장치의 설치를 의무화합니다.

ANSI/ASHRAE/IES Standard 90.1(저층 주거용 건물을 제외한 부지 및 건물의 에너지 표준)은 미국냉난방공조학회(ASHRAE)에서 발행하는 광범위하게 인정받는 에너지 표준입니다.

ASHRAE 90.1을 주목해야 하는 이유

ASHRAE 90.1은 미국 전역의 건물 에너지 코드의 기준 표준으로 사용되며, 건물 외피, HVAC 시스템, 급탕 시스템, 조명 시스템을 포함한 상업용 건물 구성 요소의 에너지 효율적 성능에 대한 최소 요구사항을 개괄하는 IECC 내 준수 경로 역할을 합니다.

ASHRAE 90.1 표준은 최대 허용 조명 전력 밀도 및 특정 구역에서의 점유 감지 센서 사용을 포함한 최소 조명 제어 요구사항을 규정합니다.

캘리포니아 건물 표준법 Part 6의 Title 24(공식 명칭: 주거용 및 비주거용 건물 에너지 효율성 표준)는 캘리포니아 에너지 위원회(CEC)에서 관리하며, 새로운 에너지 효율 기술과 방법을 반영하기 위해 주기적으로 업데이트됩니다.

Title 24를 주목해야 하는 이유

Title 24는 미국 내 다른 수많은 에너지 코드보다 더욱 엄격한 요구사항을 가진 것으로 잘 알려져 있습니다. Title 24는 난방, 환기, 공조(HVAC), 급탕, 조명을 포함한 건물 건설의 모든 측면에 대해 엄격한 에너지 성능 표준을 준수하도록 규정합니다.

Title 24는 에너지가 낭비되지 않도록 상업용 건물의 특정 구역에서 재실 여부에 따라 조명을 조절하는 점유 감지 센서 설치를 의무화합니다.

주별 에너지 코드 채택 현황

상세 표를 보려면 펼치기 ↓

주(State)현행 상업용 건축 기준상업용 건축 기준 에너지 효율 카테고리
앨라배마90.1-201390.1-2013
알래스카주 전체 기준 없음주 전체 건축 기준 없음
애리조나자치 도시 규정 적용(Home rule)<90.1-2007
아칸소2009 IECC 및 90.1-200790.1-2007
캘리포니아2022년 건물 에너지 효율 기준90.1-2019
콜로라도자치 도시 규정 적용(Home rule)주 전체 건축 기준 없음
코네티컷2021 IECC 및 90.1-201990.1-2019
델라웨어2018 IECC 및 90.1-201690.1-2013
컬럼비아 특별구90.1-2013^90.1-2019
플로리다2021 IECC 및 90.1-2019^90.1-2016
조지아2015 IECC 및 90.1-2013^90.1-2013
하와이자치 도시 규정 적용(Home rule)90.1-2013
아이다호2018 IECC 및 90.1-201690.1-2013
일리노이2021 IECC 및 90.1-201990.1-2019
인디애나90.1-200790.1-2007
아이오와2012 IECC 및 90.1-201090.1-2007
캔자스자치 도시 규정 적용(Home rule)주 전체 건축 기준 없음
켄터키2012 IECC 및 90.1-201090.1-2007
루이지애나2021 IECC 및 90.1-2019^90.1-2016
메인2015 IECC 및 90.1-201390.1-2013
메릴랜드2021 IECC 및 90.1-2019^90.1-2019
매사추세츠2018 IECC 및 90.1-2016^90.1-2019
미시간2015 IECC 및 90.1-2013^90.1-2013
미네소타90.1-2019^90.1-2019
미시시피주 전체 기준 없음주 전체 건축 기준 없음
미주리자치 도시 규정 적용(Home rule)주 전체 건축 기준 없음
몬태나2021 IECC 및 90.1-201990.1-2019
네브래스카2018 IECC 및 90.1-201690.1-2013
네바다2018 IECC 및 90.1-201690.1-2013
뉴햄프셔2018 IECC 및 90.1-2016^90.1-2013
뉴저지90.1-201990.1-2019
뉴멕시코2021 IECC 및 90.1-2019^90.1-2019
뉴욕2018 IECC 및 90.1-2016^90.1-2016
노스캐롤라이나2015 IECC 및 90.1-2013^90.1-2010
노스다코타자치 도시 규정 적용(Home rule)주 전체 건축 기준 없음
오하이오2021 IECC 및 90.1-2019^90.1-2016
오클라호마2006 IECC 및 90.1-2004<90.1-2007
오레곤90.1-201990.1-2019
펜실베이니아2018 IECC 및 90.1-201690.1-2013
로드아일랜드2018 IECC 및 90.1-2016^90.1-2013
사우스캐롤라이나2009 IECC 및 90.1-200790.1-2007
사우스다코타자치 도시 규정 적용(Home rule)주 전체 건축 기준 없음
테네시2021 IECC 및 90.1-201390.1-2007
텍사스2015 IECC 및 90.1-201390.1-2013
유타2021 IECC 및 90.1-2019^90.1-2019
버몬트2021 IECC 및 90.1-2019^90.1-2019
버기니아2021 IECC 및 90.1-2019^90.1-2019
워싱턴2018년 워싱턴주 에너지 코드90.1-2019
테네시2012 IECC 및 90.1-201090.1-2007
텍사스2015 IECC 및 90.1-201390.1-2013
유타2021 IECC 및 90.1-2019^90.1-2019
버몬트2018 IECC 및 90.1-2016^90.1-2019
버기니아2021 IECC 및 90.1-2019^90.1-2019
워싱턴2018년 워싱턴주 에너지 코드90.1-2019
웨스트버지니아주90.1-201390.1-2013
위스콘신주2015 IECC 및 90.1-2013^90.1-2010
와이오밍주자치 도시 규정 적용(Home rule)주 전체 건축 기준 없음
  • ^ 에너지 효율에 영향을 미치는 개정안을 DOE 프로토타입 건물 모델을 사용하여 정량화할 수 있는 경우, 해당 개정안은 분석에 반영되었습니다.
  • IECC와 90.1을 모두 채택하는 주의 경우, IECC 코드에 광범위한 개정안이 있는 주를 제외하고는 본 연구에서 일반적으로 IECC 코드를 주의 현행 코드로 분석합니다.

센서 솔루션

Rayzeek가 에너지 절감 과제를 어떻게 해결할 수 있는지 알아보세요.

모든 제품 및 서비스 보기

Design Guide Key Concepts for Classrooms

Designing an energy-efficient lighting control solution for classrooms involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.

Designing an energy-efficient classroom with occupancy sensors involves careful planning and strategic placement of sensors:

  • Wall Occupancy/Vacancy Sensors: Install these sensors near the main entrance of the classroom. These sensors can detect when someone enters or leaves the room, and can automatically turn the lights on or off accordingly. They can also be manually controlled to turn all lights on or off.
  • Ceiling Occupancy Sensors: These sensors should be installed in the center of the classroom, ensuring they have a clear view of the entire room to cover key areas such as the teacher’s desk, student desks, and any separate learning areas. They can detect any movement in the room, including minor movements such as students writing at their desks. When no movement is detected for a set period, the lights will automatically turn off.
  • Additional Sensors for Specific Areas: If the classroom has specific areas such as a reading corner or a lab area, additional sensors may be needed. These sensors can control the lighting in these specific areas based on occupancy, ensuring that lights are not left on unnecessarily.
  • 센서 배치 시 고려 사항: Avoid placing sensors near air vents or other sources of movement that could trigger the sensor falsely. Also, ensure the sensors’ view is not obstructed by tall furniture or fixtures.
  • Consideration of Natural Light: If the classroom has windows, the sensors should be programmed to consider the natural light coming into the room. This can help to further reduce energy consumption by utilizing natural light whenever possible.
  • Integration with Manual Control: All occupancy/vacancy sensors should be integrated with manual controls. This allows teachers to manually turn off the lights during activities like video presentations, even if the room is occupied.

Wall Sensor Switches

RZ020/021 Motion Sensor Switches

  • 2-wire, 3-wire, 4-wires wiring options
  • Occupancy, Vacancy, Manual ON/OFF
  • Adjustive time delay and ambient light control

Multi-Location Wireless Wall Sensors

RZ020A/021A + RZ022W Kits

  • Hardwired RZ021A/022A occupancy sensor switch
  • Wireless companion switch (RZ022W) for multi-location control

Ceiling Occupancy Sensors

RZ036

  • Hardwired occupancy sensors
  • Auto ON, auto OFF
  • Line voltage and Low voltage available

Core features included:

  • Integrated manual ON/OFF control for all lighting
  • Vacancy sensors (Manual ON only): Lights must be turned on manually only
  • Adjustable time-delay, lighting is automatically turned full OFF after 15mins
  • Additional: multi-location wireless kits to expand the control range without re-wring
  • Additional: multiple wiring options available for both new constructions and retrofit projects.

Meets the Mandatory Provisions

IECC – 2011

C405.2.1 Occupant sensor controls

Occupant sensor controls shall be installed to control lights in the space.

C405.2.1.1 Occupant sensor control functions

  • Manual on or partial on to no more than 50% power.
  • Full off within 20 minutes after all occupants have left the space
  • A manual control to turn off the lights.

ASHRAE 90.1 – 2022

9.4.1.1 a Local control

There shall be one or more manual lighting control device that provides ON and OFF control
of all lighting in the space.

9.4.1.1 b Restricted to manual ON

None of the lighting shall be automatically turned on

9.4.1.1 c Restricted to partial automatic ON

No more than 50% of the lighting power for the general lighting shall be allowed to be automatically turned on

** NOTE: At least one 9.4.1.1 b or 9.4.1.1 c shall be implemented.

For classrooms except shop classrooms (all other classrooms/lecture halls/training rooms):

9.4.1.1 h Automatic full OFF control

All lighting in the space shall be automatically shut off within 20 minutes of all occupants leaving the space

Title 24 – 2022

130.1 (a) Manual area controls.

Each area enclosed by ceiling-height partitions shall provide lighting controls that allow the lighting in that area to be manually turned on and off.

130.1 (c) Shut-OFF Controls.

Lighting shall be controlled with occupant sensing controls to automatically shut OFF all of the lighting in 20 minutes or less after the control zone is unoccupied that shall function either as:

  • A. Occupant sensing controls (if 130.1(b) not required to have multi-level lighting controls); or
  • B. Partial-ON occupant sensing controls, or
  • C. Vacancy sensing controls, where all lighting responds to a manual ON input only

Let us hear you.

Let Rayzeek help design and deliver a bespoke energy-saving lighting solution for you.