Classrooms

Discover the energy-saving potential of classrooms with Rayzeek’s occupancy sensor design guide. Learn how to meet energy code requirements while creating a more efficient learning environment.

Transforming Classrooms into Energy-Efficient Learning Spaces

Classrooms are dynamic spaces that serve as the foundation for learning and development. They are often filled with a variety of lighting fixtures, from overhead lights to task lighting, all of which contribute to a significant amount of energy consumption. The lighting in these spaces is typically left on for extended periods, even when the room is unoccupied, leading to unnecessary energy waste.

In a typical classroom, the lighting needs can vary greatly depending on the time of day, the activities taking place, and the number of occupants. This variability makes it challenging to manage lighting effectively and efficiently. As a result, there is a pressing need for solutions that can automatically control lighting based on occupancy, thereby reducing unnecessary energy consumption.

The need for energy conservation in classrooms is clear, and one of the most effective solutions is the use of occupancy sensors. These devices can automatically turn off lights when a room is vacant, significantly reducing energy consumption. With Rayzeek’s range of occupancy sensors, classrooms can become more energy-efficient, meeting the requirements of energy codes while also reducing operational costs.

Respectarea codurilor de energie

International Energy Conservation Code (IECC) este un cod model dezvoltat de International Code Council (ICC) pentru a stabili cerințele minime de proiectare și construcție privind eficiența energetică a clădirilor. IECC este actualizat la fiecare trei ani pentru a încorpora cele mai recente practici și tehnologii în domeniul conservării energiei.

IECC: De ce ar trebui să vă intereseze

IECC este adoptat pe scară largă de state și municipalități din întreaga regiune a Statelor Unite. IECC acoperă diverse aspecte ale utilizării energiei, inclusiv anvelopa clădirii (pereți, acoperișuri și ferestre), sistemele de încălzire și răcire, precum și sistemele de iluminat.

IECC impune controale specifice ale iluminatului, cum ar fi senzorii de prezență, pentru a minimiza risipa de energie în spațiile neocupate din diverse zone.

Standardul ANSI/ASHRAE/IES 90.1, Energy Standard for Sites and Buildings Except Low-Rise Residential Buildings, este un standard de energie recunoscut la nivel larg, publicat de American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).

ASHRAE 90.1: De ce ar trebui să vă intereseze

ASHRAE 90.1 este utilizat ca punct de referință pentru codurile de energie ale clădirilor din Statele Unite și servește ca cale de conformitate în cadrul IECC, stabilind cerințele minime pentru performanța energetică a componentelor clădirilor comerciale, inclusiv anvelopele clădirilor, sistemele HVAC, sistemele de încălzire a apei și sistemele de iluminat.

Standardul ASHRAE 90.1 specifică densitățile maxime admise ale puterii de iluminat și cerințele minime de control al iluminatului, inclusiv utilizarea senzorilor de prezență în anumite zone.

Title 24, partea 6 din California Building Standards Code, cunoscut oficial sub numele de Building Energy Efficiency Standards for Residential and Nonresidential Buildings, Title 24 este administrat de California Energy Commission și este actualizat periodic pentru a reflecta noile tehnologii și metode de eficiență energetică.

Title 24: De ce ar trebui să vă intereseze

Title 24 este cunoscut pentru cerințele sale riguroase, fiind adesea considerat mai strict decât multe alte coduri energetice din Statele Unite. Title 24 impune standarde stricte de performanță energetică pentru toate aspectele construcției clădirilor, care includ încălzirea, ventilația, aerul condiționat (HVAC), încălzirea apei și iluminatul.

Title 24 necesită instalarea de senzori de prezență care ajustează iluminatul în funcție de gradul de ocupare a încăperii în anumite zone ale clădirilor comerciale, pentru a se asigura că energia nu este risipită.

Adoptarea codului de energie pe state

Extindeți pentru a vedea tabelul detaliat ↓

StatCod comercial actualCategorie de eficiență a codului comercial
Alabama90.1-201390.1-2013
AlaskaNiciunul la nivel de statFără cod la nivel de stat
ArizonaAutonomie locală<90.1-2007
Arkansas2009 IECC și 90.1-200790.1-2007
CaliforniaStandardele de Eficiență Energetică a Clădirilor din 202290.1-2019
ColoradoAutonomie localăFără cod la nivel de stat
ConnecticutIECC 2021 și 90.1-201990.1-2019
DelawareIECC 2018 și 90.1-201690.1-2013
Districtul Columbia90.1-2013^90.1-2019
FloridaIECC 2021 și 90.1-2019^90.1-2016
GeorgiaIECC 2015 și 90.1-2013^90.1-2013
HawaiiAutonomie locală90.1-2013
IdahoIECC 2018 și 90.1-201690.1-2013
IllinoisIECC 2021 și 90.1-201990.1-2019
Indiana90.1-200790.1-2007
Iowa2012 IECC și 90.1-201090.1-2007
KansasAutonomie localăFără cod la nivel de stat
Kentucky2012 IECC și 90.1-201090.1-2007
LouisianaIECC 2021 și 90.1-2019^90.1-2016
Maine2015 IECC și 90.1-201390.1-2013
MarylandIECC 2021 și 90.1-2019^90.1-2019
Massachusetts2018 IECC și 90.1-2016^90.1-2019
MichiganIECC 2015 și 90.1-2013^90.1-2013
Minnesota90.1-2019^90.1-2019
MississippiNiciunul la nivel de statFără cod la nivel de stat
MissouriAutonomie localăFără cod la nivel de stat
MontanaIECC 2021 și 90.1-201990.1-2019
NebraskaIECC 2018 și 90.1-201690.1-2013
NevadaIECC 2018 și 90.1-201690.1-2013
New Hampshire2018 IECC și 90.1-2016^90.1-2013
New Jersey90.1-201990.1-2019
Noul MexicIECC 2021 și 90.1-2019^90.1-2019
New York2018 IECC și 90.1-2016^90.1-2016
Carolina de NordIECC 2015 și 90.1-2013^90.1-2010
Dakota de NordAutonomie localăFără cod la nivel de stat
OhioIECC 2021 și 90.1-2019^90.1-2016
Oklahoma2006 IECC și 90.1-2004<90.1-2007
Oregon90.1-201990.1-2019
PennsylvaniaIECC 2018 și 90.1-201690.1-2013
Rhode Island2018 IECC și 90.1-2016^90.1-2013
Carolina de Sud2009 IECC și 90.1-200790.1-2007
Dakota de SudAutonomie localăFără cod la nivel de stat
Tennessee2021 IECC și 90.1-201390.1-2007
Texas2015 IECC și 90.1-201390.1-2013
UtahIECC 2021 și 90.1-2019^90.1-2019
VermontIECC 2021 și 90.1-2019^90.1-2019
VirginiaIECC 2021 și 90.1-2019^90.1-2019
WashingtonCodul Energetic al Statului Washington din 201890.1-2019
Tennessee2012 IECC și 90.1-201090.1-2007
Texas2015 IECC și 90.1-201390.1-2013
UtahIECC 2021 și 90.1-2019^90.1-2019
Vermont2018 IECC și 90.1-2016^90.1-2019
VirginiaIECC 2021 și 90.1-2019^90.1-2019
WashingtonCodul Energetic al Statului Washington din 201890.1-2019
Virginia de Vest90.1-201390.1-2013
WisconsinIECC 2015 și 90.1-2013^90.1-2010
WyomingAutonomie localăFără cod la nivel de stat
  • ^ When an amendment impacting energy efficiency can be quantified using DOE Prototype Building Models, they were captured in the analysis.
  • For states adopting both IECC and 90.1, the IECC code is usually analyzed as the state current code in this study except for states with extensive amendments to the IECC.

Sensor Solutions

Find out how Rayzeek can solve your energy saving challenges.

Vizualizați toate ofertele

Ghid de proiectare - Concepte cheie pentru săli de clase

Proiectarea unei soluții de control al iluminatului eficiente din punct de vedere energetic pentru săli de clasă implică amplasarea strategică a senzorilor de prezență pentru a asigura o acoperire cuprinzătoare a spațiului.

Designing an energy-efficient classroom with occupancy sensors involves careful planning and strategic placement of sensors:

  • Wall Occupancy/Vacancy Sensors: Install these sensors near the main entrance of the classroom. These sensors can detect when someone enters or leaves the room, and can automatically turn the lights on or off accordingly. They can also be manually controlled to turn all lights on or off.
  • Ceiling Occupancy Sensors: These sensors should be installed in the center of the classroom, ensuring they have a clear view of the entire room to cover key areas such as the teacher’s desk, student desks, and any separate learning areas. They can detect any movement in the room, including minor movements such as students writing at their desks. When no movement is detected for a set period, the lights will automatically turn off.
  • Additional Sensors for Specific Areas: If the classroom has specific areas such as a reading corner or a lab area, additional sensors may be needed. These sensors can control the lighting in these specific areas based on occupancy, ensuring that lights are not left on unnecessarily.
  • Sensor Placement Considerations: Avoid placing sensors near air vents or other sources of movement that could trigger the sensor falsely. Also, ensure the sensors’ view is not obstructed by tall furniture or fixtures.
  • Consideration of Natural Light: If the classroom has windows, the sensors should be programmed to consider the natural light coming into the room. This can help to further reduce energy consumption by utilizing natural light whenever possible.
  • Integration with Manual Control: All occupancy/vacancy sensors should be integrated with manual controls. This allows teachers to manually turn off the lights during activities like video presentations, even if the room is occupied.

Wall Sensor Switches

RZ020/021 Motion Sensor Switches

  • 2-wire, 3-wire, 4-wires wiring options
  • Occupancy, Vacancy, Manual ON/OFF
  • Adjustive time delay and ambient light control

Multi-Location Wireless Wall Sensors

RZ020A/021A + RZ022W Kits

  • Hardwired RZ021A/022A occupancy sensor switch
  • Wireless companion switch (RZ022W) for multi-location control

Ceiling Occupancy Sensors

RZ036

  • Hardwired occupancy sensors
  • Auto ON, auto OFF
  • Line voltage and Low voltage available

Core features included:

  • Integrated manual ON/OFF control for all lighting
  • Vacancy sensors (Manual ON only): Lights must be turned on manually only
  • Adjustable time-delay, lighting is automatically turned full OFF after 15mins
  • Additional: multi-location wireless kits to expand the control range without re-wring
  • Additional: multiple wiring options available for both new constructions and retrofit projects.

Meets the Mandatory Provisions

IECC – 2011

C405.2.1 Occupant sensor controls

Occupant sensor controls shall be installed to control lights in the space.

C405.2.1.1 Occupant sensor control functions

  • Manual on or partial on to no more than 50% power.
  • Full off within 20 minutes after all occupants have left the space
  • A manual control to turn off the lights.

ASHRAE 90.1 – 2022

9.4.1.1 a Local control

There shall be one or more manual lighting control device that provides ON and OFF control
of all lighting in the space.

9.4.1.1 b Restricted to manual ON

None of the lighting shall be automatically turned on

9.4.1.1 c Restricted to partial automatic ON

No more than 50% of the lighting power for the general lighting shall be allowed to be automatically turned on

** NOTE: At least one 9.4.1.1 b or 9.4.1.1 c shall be implemented.

For classrooms except shop classrooms (all other classrooms/lecture halls/training rooms):

9.4.1.1 h Automatic full OFF control

All lighting in the space shall be automatically shut off within 20 minutes of all occupants leaving the space

Title 24 – 2022

130.1 (a) Manual area controls.

Each area enclosed by ceiling-height partitions shall provide lighting controls that allow the lighting in that area to be manually turned on and off.

130.1 (c) Shut-OFF Controls.

Lighting shall be controlled with occupant sensing controls to automatically shut OFF all of the lighting in 20 minutes or less after the control zone is unoccupied that shall function either as:

  • A. Occupant sensing controls (if 130.1(b) not required to have multi-level lighting controls); or
  • B. Partial-ON occupant sensing controls, or
  • C. Vacancy sensing controls, where all lighting responds to a manual ON input only