storage rooms
Discover the energy-saving potential of storage rooms with Rayzeek’s occupancy sensor design guide.

Maximize Energy Efficiency in Storage Rooms with Occupancy Sensors
Storage rooms, often overlooked, are integral parts of commercial buildings. These spaces are typically filled with shelves, boxes, and various items, and are used for storing supplies, equipment, or archived documents. Lighting in these areas is crucial for visibility and safety, but it can also be a significant source of energy waste. Traditional lighting systems in storage rooms are often left on unnecessarily, leading to high energy consumption and costs.
Moreover, storage rooms are usually equipped with fluorescent or LED lights, which, while energy-efficient, can still consume a considerable amount of power when left on for extended periods. The sporadic and unpredictable nature of storage room usage further exacerbates this issue, as lights are often left on even when the room is unoccupied, leading to unnecessary energy waste.
This energy wastage can be mitigated by using occupancy sensors. These devices automatically control lighting based on the presence or absence of people, ensuring lights are only on when needed. By installing occupancy sensors in storage rooms, businesses can significantly reduce their energy consumption, lower their utility bills, and contribute to a more sustainable environment.
Einhaltung der Energieeinsparverordnungen

Der International Energy Conservation Code (IECC) ist ein vom International Code Council (ICC) entwickelter Musterkodex zur Festlegung von Mindestanforderungen an die Energieeffizienz bei der Planung und dem Bau von Gebäuden. Der IECC wird alle drei Jahre aktualisiert, um die neuesten Verfahren und Technologien zur Energieeinsparung zu berücksichtigen.
IECC – Warum das Thema für Sie wichtig ist
Der IECC ist in vielen Bundesstaaten und Kommunen der Vereinigten Staaten weit verbreitet. Der IECC deckt verschiedene Aspekte der Energienutzung ab, darunter die Gebäudehülle (Wände, Dächer und Fenster), Heiz- und Kühlgesellschaften sowie Beleuchtungssysteme.
Der IECC schreibt spezifische Beleuchtungssteuerungen wie Präsenzmelder vor, um die Energieverschwendung in ungenutzten Räumen in verschiedenen Bereichen zu minimieren.

ANSI/ASHRAE/IES Standard 90.1, Energiestandard für Standorte und Gebäude außer wohnungsähnlichen Flachbauten, ist ein weit verbreiteter Energiestandard, der von der American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) herausgegeben wird.
ASHRAE 90.1 – Warum das für Sie wichtig ist
ASHRAE 90.1 dient in den Vereinigten Staaten als Maßstab für Energieeinsparverordnungen im Gebäudebereich und fungiert als Konformitätsweg innerhalb des IECC, der die Mindestanforderungen an die Energieeffizienz von Komponenten gewerblicher Gebäude – einschließlich Gebäudehüllen, HVAC-Systemen, Warmwasserbereitungsanlagen und Beleuchtungssystemen – festlegt.
Der Standard ASHRAE 90.1 legt die maximal zulässige Beleuchtungsleistungsdichte und die Mindestanforderungen an die Beleuchtungssteuerung fest, einschließlich des Einsatzes von Präsenzmeldern in bestimmten Bereichen.

Title 24, Teil 6 des California Building Standards Code, offiziell bekannt als Building Energy Efficiency Standards for Residential and Nonresidential Buildings, wird von der California Energy Commission verwaltet und regelmäßig aktualisiert, um neue Technologien und Methoden zur Energieeffizienz zu berücksichtigen.
Title 24 – Warum das für Sie wichtig ist
Title 24 ist für seine strengen Anforderungen bekannt, die oft als anspruchsvoller gelten als die vieler anderer Energieeinsparverordnungen in den Vereinigten Staaten. Title 24 schreibt strenge Energieeffizienzstandards für alle Aspekte des Hochbaus vor, einschließlich Heizung, Lüftung, Klima (HVAC), Warmwasserbereitung und Beleuchtung.
Title 24 erfordert die Installation von Präsenzmeldern, die die Beleuchtung je nach Raumbelegung in bestimmten Bereichen von Gewerbegebäuden anpassen, um sicherzustellen, dass keine Energie verschwendet wird.
Übernahme von Energieeinsparverordnungen nach Bundesstaat

Aufklappen, um die detaillierte Tabelle anzuzeigen ↓
| Bundesstaat | Aktuelle gewerbliche Bauvorschrift | Effizienzkategorie für gewerbliche Bauvorschriften |
|---|---|---|
| Alabama | 90.1-2013 | 90.1-2013 |
| Alaska | Keine bundeslandweite Regelung | Keine bundeslandweite Vorschrift |
| Arizona | Kommunale Selbstverwaltung | <90.1-2007 |
| Arkansas | 2009 IECC und 90.1-2007 | 90.1-2007 |
| Kalifornien | Building Energy Efficiency Standards 2022 | 90.1-2019 |
| Colorado | Kommunale Selbstverwaltung | Keine bundeslandweite Vorschrift |
| Connecticut | 2021 IECC und 90.1-2019 | 90.1-2019 |
| Delaware | 2018 IECC und 90.1-2016 | 90.1-2013 |
| District of Columbia | 90.1-2013^ | 90.1-2019 |
| Florida | 2021 IECC und 90.1-2019^ | 90.1-2016 |
| Georgia | 2015 IECC und 90.1-2013^ | 90.1-2013 |
| Hawaii | Kommunale Selbstverwaltung | 90.1-2013 |
| Idaho | 2018 IECC und 90.1-2016 | 90.1-2013 |
| Illinois | 2021 IECC und 90.1-2019 | 90.1-2019 |
| Indiana | 90.1-2007 | 90.1-2007 |
| Iowa | 2012 IECC und 90.1-2010 | 90.1-2007 |
| Kansas | Kommunale Selbstverwaltung | Keine bundeslandweite Vorschrift |
| Kentucky | 2012 IECC und 90.1-2010 | 90.1-2007 |
| Louisiana | 2021 IECC und 90.1-2019^ | 90.1-2016 |
| Maine | 2015 IECC und 90.1-2013 | 90.1-2013 |
| Maryland | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Massachusetts | 2018 IECC und 90.1-2016^ | 90.1-2019 |
| Michigan | 2015 IECC und 90.1-2013^ | 90.1-2013 |
| Minnesota | 90.1-2019^ | 90.1-2019 |
| Mississippi | Keine bundeslandweite Regelung | Keine bundeslandweite Vorschrift |
| Missouri | Kommunale Selbstverwaltung | Keine bundeslandweite Vorschrift |
| Montana | 2021 IECC und 90.1-2019 | 90.1-2019 |
| Nebraska | 2018 IECC und 90.1-2016 | 90.1-2013 |
| Nevada | 2018 IECC und 90.1-2016 | 90.1-2013 |
| New Hampshire | 2018 IECC und 90.1-2016^ | 90.1-2013 |
| New Jersey | 90.1-2019 | 90.1-2019 |
| New Mexico | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| New York | 2018 IECC und 90.1-2016^ | 90.1-2016 |
| North Carolina | 2015 IECC und 90.1-2013^ | 90.1-2010 |
| North Dakota | Kommunale Selbstverwaltung | Keine bundeslandweite Vorschrift |
| Ohio | 2021 IECC und 90.1-2019^ | 90.1-2016 |
| Oklahoma | 2006 IECC und 90.1-2004 | <90.1-2007 |
| Oregon | 90.1-2019 | 90.1-2019 |
| Pennsylvania | 2018 IECC und 90.1-2016 | 90.1-2013 |
| Rhode Island | 2018 IECC und 90.1-2016^ | 90.1-2013 |
| South Carolina | 2009 IECC und 90.1-2007 | 90.1-2007 |
| South Dakota | Kommunale Selbstverwaltung | Keine bundeslandweite Vorschrift |
| Tennessee | 2021 IECC und 90.1-2013 | 90.1-2007 |
| Texas | 2015 IECC und 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Vermont | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Virginia | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Washington | Energieeinsparverordnung des Staates Washington von 2018 | 90.1-2019 |
| Tennessee | 2012 IECC und 90.1-2010 | 90.1-2007 |
| Texas | 2015 IECC und 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Vermont | 2018 IECC und 90.1-2016^ | 90.1-2019 |
| Virginia | 2021 IECC und 90.1-2019^ | 90.1-2019 |
| Washington | Energieeinsparverordnung des Staates Washington von 2018 | 90.1-2019 |
| West Virginia | 90.1-2013 | 90.1-2013 |
| Wisconsin | 2015 IECC und 90.1-2013^ | 90.1-2010 |
| Wyoming | Kommunale Selbstverwaltung | Keine bundeslandweite Vorschrift |
- ^ Wenn eine Änderung mit Auswirkungen auf die Energieeffizienz mithilfe von DOE-Prototyp-Gebäudemodellen quantifiziert werden kann, wurde sie in die Analyse einbezogen.
- Für Staaten, die sowohl den IECC als auch 90.1 übernehmen, wird in dieser Studie in der Regel der IECC-Code als der aktuelle staatliche Code analysiert, außer in Staaten mit umfangreichen Änderungen am IECC.
Design Guide Key Concepts for Private Offices
Designing an energy-efficient lighting control solution for private offices involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.

In a storage room, the primary areas that require lighting are the main walkways and the individual aisles between shelves. Here are some guidelines to follow:
- Main Walkways: Install ceiling occupancy sensors at regular intervals along the main walkways. These sensors should be set to Auto ON and Full OFF mode, ensuring that lights turn on automatically when someone enters the walkway and turn off when the area is vacant.
- Individual Aisles: For individual aisles between shelves, consider installing wall occupancy sensors at the entrance of each aisle. These sensors can detect when someone enters the aisle and turn on the lights accordingly. Given the sporadic usage of these aisles, the sensors should be set to Manual ON and Full OFF mode. This means that the lights will only turn on when manually switched on but will turn off automatically when the aisle is vacant.
- Entrance Area: The entrance area of the storage room should have a wall sensor switch that allows manual control of all lighting in the room. This switch can be used to turn all lights on or off as needed, providing an additional layer of control.
- Sensor Placement Considerations: When placing sensors, ensure they are not located near air vents or other sources of movement that could trigger false positives. Also, ensure that the sensors’ field of view is not obstructed by shelves or stored items.
- Sensor Height: Consider the height of the sensor installation. Sensors should be installed at a height that allows for optimal coverage of the room, taking into account the height of stored items.
- Manuelle Steuerung: Incorporate manual controls to allow users to turn ON/OFF all lighting when needed. This can be particularly useful in storage rooms where lighting may be required for extended periods during inventory checks or reorganization tasks.
Empfohlene Produkte & Lösungen
Enthaltene Hauptfunktionen:
- Integrierte manuelle EIN/AUS-Steuerung für sämtliche Beleuchtungen
- Abwesenheitssensoren (nur manuelles Einschalten): Licht muss ausschließlich manuell eingeschaltet werden
- Einstellbare Zeitverzögerung, Beleuchtung wird nach 15 Minuten automatisch vollständig ausgeschaltet
- Zusätzlich: Drahtlose Mehrstellen-Sets zur Erweiterung des Steuerungsbereichs ohne Neuverdrahtung
- Zusätzlich: Mehrere Verdrahtungsoptionen für Neubauten und Nachrüstprojekte verfügbar.

Erfüllt die obligatorischen Bestimmungen
IECC – 2011
C405.2.1 Steuerungen durch Präsenzsensoren
Steuerungen durch Präsenzsensoren müssen installiert werden, um die Beleuchtung im Raum zu steuern.
C405.2.1.1 Funktionen der Präsenzsensorsteuerung
- Manuelles Einschalten oder teilweises Einschalten auf maximal 50% Leistung.
- Vollständiges Ausschalten innerhalb von 20 Minuten, nachdem alle Personen den Raum verlassen haben
- Eine manuelle Steuerung zum Ausschalten der Beleuchtung.
ASHRAE 90.1 – 2022
9.4.1.1 a Local control
There shall be one or more manual lighting control device that provides ON and OFF control
of all lighting in the space.
9.4.1.1 H Automatische vollständige AUS-Steuerung
Die gesamte Beleuchtung im Raum muss innerhalb von 20 Minuten, nachdem alle Personen den Raum verlassen haben, automatisch ausgeschaltet werden
Additionally, for storage rooms with sizes <50 ft2:
9.4.1.1 b Restricted to manual ON
None of the lighting shall be automatically turned on
Title 24 – 2022
130.1 (a) Manuelle Bereichssteuerungen.
Jeder durch deckenhohe Trennwände umschlossene Bereich muss mit Lichtsteuerungen ausgestattet sein, die ein manuelles Ein- und Ausschalten der Beleuchtung in diesem Bereich ermöglichen.
130.1 (c) Abschaltsteuerungen.
Die Beleuchtung muss mit Präsenzsteuerungen gesteuert werden, um die gesamte Beleuchtung innerhalb von 20 Minuten oder weniger, nachdem die Steuerzone unbelegt ist, automatisch AUSZUSCHALTEN, was wie folgt funktionieren muss:
- A. Präsenzsteuerungen (falls gemäß 130.1(b) keine mehrstufigen Beleuchtungssteuerungen erforderlich sind); oder
- B. Teil-EIN-Präsenzsteuerungen; oder
- C. Abwesenheitssteuerungen, bei denen die gesamte Beleuchtung nur auf ein manuelles EIN-Signal reagiert
Sprechen Sie mit uns.
Lassen Sie Rayzeek eine maßgeschneiderte, energieeffiziente Beleuchtungslösung für Sie entwickeln und umsetzen.