Discover the energy-saving potential of classrooms with Rayzeek’s occupancy sensor design guide. Learn how to meet energy code requirements while creating a more efficient learning environment.

Transforming Classrooms into Energy-Efficient Learning Spaces
Classrooms are dynamic spaces that serve as the foundation for learning and development. They are often filled with a variety of lighting fixtures, from overhead lights to task lighting, all of which contribute to a significant amount of energy consumption. The lighting in these spaces is typically left on for extended periods, even when the room is unoccupied, leading to unnecessary energy waste.
In a typical classroom, the lighting needs can vary greatly depending on the time of day, the activities taking place, and the number of occupants. This variability makes it challenging to manage lighting effectively and efficiently. As a result, there is a pressing need for solutions that can automatically control lighting based on occupancy, thereby reducing unnecessary energy consumption.
The need for energy conservation in classrooms is clear, and one of the most effective solutions is the use of occupancy sensors. These devices can automatically turn off lights when a room is vacant, significantly reducing energy consumption. With Rayzeek’s range of occupancy sensors, classrooms can become more energy-efficient, meeting the requirements of energy codes while also reducing operational costs.
Respecter les codes de l'énergie

L'IECC (International Energy Conservation Code) est un code modèle élaboré par l'ICC (International Code Council) afin d'établir les exigences minimales de conception et de construction pour l'efficacité énergétique des bâtiments. L'IECC est mis à jour tous les trois ans pour intégrer les dernières pratiques et technologies en matière d'économies d'énergie.
IECC, pourquoi vous devriez vous en soucier
L'IECC est largement adopté par les États et les municipalités à travers les États-Unis. L'IECC couvre divers aspects de la consommation d'énergie, notamment l'enveloppe du bâtiment (murs, toits et fenêtres), les systèmes de chauffage et de refroidissement, ainsi que les systèmes d'éclairage.
L'IECC impose des commandes d'éclairage spécifiques, telles que des détecteurs de présence, afin de minimiser le gaspillage d'énergie dans les espaces inoccupés de diverses zones.

La norme ANSI/ASHRAE/IES 90.1, Norme énergétique pour les sites et les bâtiments à l'exclusion des bâtiments résidentiels bas, est une norme énergétique largement reconnue publiée par l'American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).
ASHRAE 90.1, pourquoi vous devriez vous en soucier
La norme ASHRAE 90.1 sert de référence pour les codes énergétiques du bâtiment à travers les États-Unis et constitue une voie de conformité au sein de l'IECC. Elle définit les exigences minimales en matière de performance d'efficacité énergétique des composants des bâtiments commerciaux, y compris les enveloppes de bâtiment, les systèmes CVC, les systèmes de chauffage de l'eau et les systèmes d'éclairage.
La norme ASHRAE 90.1 spécifie les densités de puissance d'éclairage maximales autorisées et les exigences minimales en matière de contrôle de l'éclairage, notamment l'utilisation de détecteurs de présence dans des zones spécifiques.

Titre 24, partie 6 du California Building Standards Code, officiellement connu sous le nom de Building Energy Efficiency Standards for Residential and Nonresidential Buildings, le Titre 24 est administré par la California Energy Commission et est mis à jour périodiquement pour refléter les nouvelles technologies et méthodes d'efficacité énergétique.
Titre 24, pourquoi vous devriez vous en soucier
Le Titre 24 est reconnu pour ses exigences rigoureuses, souvent considérées comme plus strictes que celles de nombreux autres codes énergétiques aux États-Unis. Le Titre 24 impose des normes de performance énergétique strictes pour tous les aspects de la construction de bâtiments, ce qui comprend le chauffage, la ventilation, la climatisation (CVC), le chauffage de l'eau et l'éclairage.
Le Titre 24 exige l'installation de détecteurs de présence qui ajustent l'éclairage en fonction de l'occupation des pièces dans des zones spécifiques des bâtiments commerciaux pour garantir que l'énergie ne soit pas gaspillée.
Adoption des codes énergétiques par État

Développer pour voir le tableau détaillé ↓
| État | Code commercial actuel | Catégorie d'efficacité du code commercial |
|---|---|---|
| Alabama | 90.1-2013 | 90.1-2013 |
| Alaska | Aucun à l'échelle de l'État | Pas de code à l'échelle de l'État |
| Arizona | Autonomie communale | <90.1-2007 |
| Arkansas | IECC 2009 et 90.1-2007 | 90.1-2007 |
| Californie | Normes d'efficacité énergétique des bâtiments de 2022 | 90.1-2019 |
| Colorado | Autonomie communale | Pas de code à l'échelle de l'État |
| Connecticut | IECC 2021 et 90.1-2019 | 90.1-2019 |
| Delaware | IECC 2018 et 90.1-2016 | 90.1-2013 |
| District de Columbia | 90.1-2013^ | 90.1-2019 |
| Floride | IECC 2021 et 90.1-2019^ | 90.1-2016 |
| Géorgie | IECC 2015 et 90.1-2013^ | 90.1-2013 |
| Hawaï | Autonomie communale | 90.1-2013 |
| Idaho | IECC 2018 et 90.1-2016 | 90.1-2013 |
| Illinois | IECC 2021 et 90.1-2019 | 90.1-2019 |
| Indiana | 90.1-2007 | 90.1-2007 |
| Iowa | IECC 2012 et ASHRAE 90.1-2010 | 90.1-2007 |
| Kansas | Autonomie communale | Pas de code à l'échelle de l'État |
| Kentucky | IECC 2012 et ASHRAE 90.1-2010 | 90.1-2007 |
| Louisiane | IECC 2021 et 90.1-2019^ | 90.1-2016 |
| Maine | IECC 2015 et ASHRAE 90.1-2013 | 90.1-2013 |
| Maryland | IECC 2021 et 90.1-2019^ | 90.1-2019 |
| Massachusetts | IECC 2018 et ASHRAE 90.1-2016^ | 90.1-2019 |
| Michigan | IECC 2015 et 90.1-2013^ | 90.1-2013 |
| Minnesota | 90.1-2019^ | 90.1-2019 |
| Mississippi | Aucun à l'échelle de l'État | Pas de code à l'échelle de l'État |
| Missouri | Autonomie communale | Pas de code à l'échelle de l'État |
| Montana | IECC 2021 et 90.1-2019 | 90.1-2019 |
| Nebraska | IECC 2018 et 90.1-2016 | 90.1-2013 |
| Nevada | IECC 2018 et 90.1-2016 | 90.1-2013 |
| Nouveau-Hampshire | IECC 2018 et ASHRAE 90.1-2016^ | 90.1-2013 |
| New Jersey | 90.1-2019 | 90.1-2019 |
| Nouveau-Mexique | IECC 2021 et 90.1-2019^ | 90.1-2019 |
| New York | IECC 2018 et ASHRAE 90.1-2016^ | 90.1-2016 |
| Caroline du Nord | IECC 2015 et 90.1-2013^ | 90.1-2010 |
| Dakota du Nord | Autonomie communale | Pas de code à l'échelle de l'État |
| Ohio | IECC 2021 et 90.1-2019^ | 90.1-2016 |
| Oklahoma | 2006 IECC et 90.1-2004 | <90.1-2007 |
| Oregon | 90.1-2019 | 90.1-2019 |
| Pennsylvanie | IECC 2018 et 90.1-2016 | 90.1-2013 |
| Rhode Island | IECC 2018 et ASHRAE 90.1-2016^ | 90.1-2013 |
| Caroline du Sud | IECC 2009 et 90.1-2007 | 90.1-2007 |
| Dakota du Sud | Autonomie communale | Pas de code à l'échelle de l'État |
| Tennessee | 2021 IECC et 90.1-2013 | 90.1-2007 |
| Texas | IECC 2015 et ASHRAE 90.1-2013 | 90.1-2013 |
| Utah | IECC 2021 et 90.1-2019^ | 90.1-2019 |
| Vermont | IECC 2021 et 90.1-2019^ | 90.1-2019 |
| Virginie | IECC 2021 et 90.1-2019^ | 90.1-2019 |
| Washington | Code de l'énergie de l'État de Washington 2018 | 90.1-2019 |
| Tennessee | IECC 2012 et ASHRAE 90.1-2010 | 90.1-2007 |
| Texas | IECC 2015 et ASHRAE 90.1-2013 | 90.1-2013 |
| Utah | IECC 2021 et 90.1-2019^ | 90.1-2019 |
| Vermont | IECC 2018 et ASHRAE 90.1-2016^ | 90.1-2019 |
| Virginie | IECC 2021 et 90.1-2019^ | 90.1-2019 |
| Washington | Code de l'énergie de l'État de Washington 2018 | 90.1-2019 |
| Gaspésie–Îles-de-la-Madeleine / Virginie-Occidentale | 90.1-2013 | 90.1-2013 |
| Wisconsin | IECC 2015 et 90.1-2013^ | 90.1-2010 |
| Wyoming | Autonomie communale | Pas de code à l'échelle de l'État |
- ^ Lorsqu'un amendement ayant un impact sur l'efficacité énergétique peut être quantifié à l'aide des modèles de bâtiments prototypes du DOE, il a été pris en compte dans l'analyse.
- Pour les États adoptant à la fois l'IECC et la norme 90.1, le code IECC est généralement analysé comme le code en vigueur de l'État dans cette étude, à l'exception des États ayant apporté des amendements importants à l'IECC.
Design Guide Key Concepts for Classrooms
Designing an energy-efficient lighting control solution for classrooms involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.

Designing an energy-efficient classroom with occupancy sensors involves careful planning and strategic placement of sensors:
- Wall Occupancy/Vacancy Sensors: Install these sensors near the main entrance of the classroom. These sensors can detect when someone enters or leaves the room, and can automatically turn the lights on or off accordingly. They can also be manually controlled to turn all lights on or off.
- Détecteurs de présence pour plafond: These sensors should be installed in the center of the classroom, ensuring they have a clear view of the entire room to cover key areas such as the teacher’s desk, student desks, and any separate learning areas. They can detect any movement in the room, including minor movements such as students writing at their desks. When no movement is detected for a set period, the lights will automatically turn off.
- Additional Sensors for Specific Areas: If the classroom has specific areas such as a reading corner or a lab area, additional sensors may be needed. These sensors can control the lighting in these specific areas based on occupancy, ensuring that lights are not left on unnecessarily.
- Considérations relatives à l'emplacement des détecteurs: Avoid placing sensors near air vents or other sources of movement that could trigger the sensor falsely. Also, ensure the sensors’ view is not obstructed by tall furniture or fixtures.
- Consideration of Natural Light: If the classroom has windows, the sensors should be programmed to consider the natural light coming into the room. This can help to further reduce energy consumption by utilizing natural light whenever possible.
- Integration with Manual Control: All occupancy/vacancy sensors should be integrated with manual controls. This allows teachers to manually turn off the lights during activities like video presentations, even if the room is occupied.
Produits et solutions en vedette
Caractéristiques principales incluses :
- Commande manuelle Marche/Arrêt intégrée pour l'ensemble de l'éclairage
- Détecteurs d'absence (allumage manuel uniquement) : les lumières doivent être allumées uniquement de manière manuelle
- Temporisation réglable, l'éclairage s'éteint automatiquement et complètement au bout de 15 min
- En option : kits sans fil multi-emplacements pour étendre la portée de contrôle sans re-câblage
- En option : plusieurs options de câblage disponibles pour les nouvelles constructions et les projets de rénovation.

Conforme aux dispositions obligatoires
IECC – 2011
C405.2.1 Commandes par détecteur de présence
Des commandes par détecteur de présence doivent être installées pour contrôler l'éclairage dans l'espace.
C405.2.1.1 Fonctions de commande par détecteur de présence
- Allumage manuel ou allumage partiel à pas plus de 50% de puissance.
- Extinction complète dans les 20 minutes suivant le départ de tous les occupants de l'espace
- Une commande manuelle pour éteindre les lumières.
ASHRAE 90.1 – 2022
9.4.1.1 a Commande locale
Il doit y avoir un ou plusieurs dispositifs de commande manuelle de l'éclairage assurant le contrôle MARCHE et ARRÊT
de tout l'éclairage de l'espace.
9.4.1.1 b Limité à l'allumage manuel
Aucun éclairage ne doit s'allumer automatiquement
9.4.1.1 c Restricted to partial automatic ON
No more than 50% of the lighting power for the general lighting shall be allowed to be automatically turned on
** NOTE: At least one 9.4.1.1 b or 9.4.1.1 c shall be implemented.
For classrooms except shop classrooms (all other classrooms/lecture halls/training rooms):
9.4.1.1 h Automatic full OFF control
Tout l'éclairage de l'espace doit s'éteindre automatiquement dans les 20 minutes suivant le départ de tous les occupants de l'espace
Titre 24 – 2022
130.1 (a) Commandes manuelles de zone.
Chaque zone délimitée par des cloisons jusqu'au plafond doit être équipée de commandes d'éclairage permettant d'allumer et d'éteindre manuellement l'éclairage de cette zone.
130.1 (c) Commandes d'extinction.
L'éclairage doit être contrôlé par des détecteurs de présence afin d'éteindre automatiquement tout l'éclairage dans un délai maximal de 20 minutes après que la zone de contrôle n'est plus occupée, fonctionnant soit comme :
- A. Commandes par détecteur de présence (si la section 130.1(b) ne requiert pas de commandes d'éclairage multiniveau) ; ou
- B. Commandes par détecteur de présence avec allumage partiel (Partial-ON), ou
- C. Commandes par détecteur d'absence, où tout l'éclairage réagit uniquement à une commande d'allumage manuel