Revolutionize Your Open Office Lighting with Smart Occupancy Sensors

Open offices, characterized by their large areas and cubicle partitions, are a common sight in many modern workplaces. These spaces are typically bustling with activity, filled with employees working, collaborating, and moving around. The expansive area requires ample illumination, often provided by high-intensity light fixtures. These lights, left on throughout the workday, consume a substantial amount of energy. Moreover, even when the office is vacant, during off-hours or lunch breaks, the lights often remain on, leading to unnecessary energy consumption.

The high energy consumption of lighting in open offices is a concern for both environmental and economic reasons. With the increasing emphasis on energy efficiency and sustainability, businesses are seeking ways to reduce their energy footprint. Moreover, energy costs can account for a significant portion of a company’s operating expenses, making energy-saving measures a smart financial decision as well.

To address this, the integration of occupancy sensors in open offices presents a compelling solution. Occupancy sensors can automatically control lighting based on the presence of individuals in the space, significantly reducing unnecessary energy consumption. When the office is vacant, the sensors can automatically switch off or dim the lights, thereby conserving energy. With our sensors seamlessly integrated into your open office layout, you can transform your open office into an energy-efficient workspace that meets the stringent requirements of US Energy Codes.

Respectarea codurilor de energie

International Energy Conservation Code (IECC) este un cod model dezvoltat de International Code Council (ICC) pentru a stabili cerințele minime de proiectare și construcție privind eficiența energetică a clădirilor. IECC este actualizat la fiecare trei ani pentru a încorpora cele mai recente practici și tehnologii în domeniul conservării energiei.

IECC: De ce ar trebui să vă intereseze

IECC este adoptat pe scară largă de state și municipalități din întreaga regiune a Statelor Unite. IECC acoperă diverse aspecte ale utilizării energiei, inclusiv anvelopa clădirii (pereți, acoperișuri și ferestre), sistemele de încălzire și răcire, precum și sistemele de iluminat.

IECC impune controale specifice ale iluminatului, cum ar fi senzorii de prezență, pentru a minimiza risipa de energie în spațiile neocupate din diverse zone.

Standardul ANSI/ASHRAE/IES 90.1, Energy Standard for Sites and Buildings Except Low-Rise Residential Buildings, este un standard de energie recunoscut la nivel larg, publicat de American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).

ASHRAE 90.1: De ce ar trebui să vă intereseze

ASHRAE 90.1 este utilizat ca punct de referință pentru codurile de energie ale clădirilor din Statele Unite și servește ca cale de conformitate în cadrul IECC, stabilind cerințele minime pentru performanța energetică a componentelor clădirilor comerciale, inclusiv anvelopele clădirilor, sistemele HVAC, sistemele de încălzire a apei și sistemele de iluminat.

Standardul ASHRAE 90.1 specifică densitățile maxime admise ale puterii de iluminat și cerințele minime de control al iluminatului, inclusiv utilizarea senzorilor de prezență în anumite zone.

Title 24, partea 6 din California Building Standards Code, cunoscut oficial sub numele de Building Energy Efficiency Standards for Residential and Nonresidential Buildings, Title 24 este administrat de California Energy Commission și este actualizat periodic pentru a reflecta noile tehnologii și metode de eficiență energetică.

Title 24: De ce ar trebui să vă intereseze

Title 24 este cunoscut pentru cerințele sale riguroase, fiind adesea considerat mai strict decât multe alte coduri energetice din Statele Unite. Title 24 impune standarde stricte de performanță energetică pentru toate aspectele construcției clădirilor, care includ încălzirea, ventilația, aerul condiționat (HVAC), încălzirea apei și iluminatul.

Title 24 necesită instalarea de senzori de prezență care ajustează iluminatul în funcție de gradul de ocupare a încăperii în anumite zone ale clădirilor comerciale, pentru a se asigura că energia nu este risipită.

Adoptarea codului de energie pe state

Extindeți pentru a vedea tabelul detaliat ↓

StatCod comercial actualCategorie de eficiență a codului comercial
Alabama90.1-201390.1-2013
AlaskaNiciunul la nivel de statFără cod la nivel de stat
ArizonaAutonomie locală<90.1-2007
Arkansas2009 IECC și 90.1-200790.1-2007
CaliforniaStandardele de Eficiență Energetică a Clădirilor din 202290.1-2019
ColoradoAutonomie localăFără cod la nivel de stat
ConnecticutIECC 2021 și 90.1-201990.1-2019
DelawareIECC 2018 și 90.1-201690.1-2013
Districtul Columbia90.1-2013^90.1-2019
FloridaIECC 2021 și 90.1-2019^90.1-2016
GeorgiaIECC 2015 și 90.1-2013^90.1-2013
HawaiiAutonomie locală90.1-2013
IdahoIECC 2018 și 90.1-201690.1-2013
IllinoisIECC 2021 și 90.1-201990.1-2019
Indiana90.1-200790.1-2007
Iowa2012 IECC și 90.1-201090.1-2007
KansasAutonomie localăFără cod la nivel de stat
Kentucky2012 IECC și 90.1-201090.1-2007
LouisianaIECC 2021 și 90.1-2019^90.1-2016
Maine2015 IECC și 90.1-201390.1-2013
MarylandIECC 2021 și 90.1-2019^90.1-2019
Massachusetts2018 IECC și 90.1-2016^90.1-2019
MichiganIECC 2015 și 90.1-2013^90.1-2013
Minnesota90.1-2019^90.1-2019
MississippiNiciunul la nivel de statFără cod la nivel de stat
MissouriAutonomie localăFără cod la nivel de stat
MontanaIECC 2021 și 90.1-201990.1-2019
NebraskaIECC 2018 și 90.1-201690.1-2013
NevadaIECC 2018 și 90.1-201690.1-2013
New Hampshire2018 IECC și 90.1-2016^90.1-2013
New Jersey90.1-201990.1-2019
Noul MexicIECC 2021 și 90.1-2019^90.1-2019
New York2018 IECC și 90.1-2016^90.1-2016
Carolina de NordIECC 2015 și 90.1-2013^90.1-2010
Dakota de NordAutonomie localăFără cod la nivel de stat
OhioIECC 2021 și 90.1-2019^90.1-2016
Oklahoma2006 IECC și 90.1-2004<90.1-2007
Oregon90.1-201990.1-2019
PennsylvaniaIECC 2018 și 90.1-201690.1-2013
Rhode Island2018 IECC și 90.1-2016^90.1-2013
Carolina de Sud2009 IECC și 90.1-200790.1-2007
Dakota de SudAutonomie localăFără cod la nivel de stat
Tennessee2021 IECC și 90.1-201390.1-2007
Texas2015 IECC și 90.1-201390.1-2013
UtahIECC 2021 și 90.1-2019^90.1-2019
VermontIECC 2021 și 90.1-2019^90.1-2019
VirginiaIECC 2021 și 90.1-2019^90.1-2019
WashingtonCodul Energetic al Statului Washington din 201890.1-2019
Tennessee2012 IECC și 90.1-201090.1-2007
Texas2015 IECC și 90.1-201390.1-2013
UtahIECC 2021 și 90.1-2019^90.1-2019
Vermont2018 IECC și 90.1-2016^90.1-2019
VirginiaIECC 2021 și 90.1-2019^90.1-2019
WashingtonCodul Energetic al Statului Washington din 201890.1-2019
Virginia de Vest90.1-201390.1-2013
WisconsinIECC 2015 și 90.1-2013^90.1-2010
WyomingAutonomie localăFără cod la nivel de stat
  • ^ When an amendment impacting energy efficiency can be quantified using DOE Prototype Building Models, they were captured in the analysis.
  • For states adopting both IECC and 90.1, the IECC code is usually analyzed as the state current code in this study except for states with extensive amendments to the IECC.

Sensor Solutions

Find out how Rayzeek can solve your energy saving challenges.

Vizualizați toate ofertele

Design Guide Key Concepts for Open Offices

Designing an energy-efficient lighting control solution for open offices involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.

In an open office setting, the primary areas to consider for sensor placement are the main walkways and areas with high foot traffic. These areas are crucial for sensor placement as they are the main areas of human traffic:

  • Cover Main Walkways: The main walkways in an open office are the areas with the highest foot traffic. Therefore, these should be the primary focus when placing sensors. Ceiling-mounted sensors are ideal for these areas as they provide a wide coverage area and are strategically placed to cover the entire length.
  • Overlap Coverage on Walkways: To avoid blind spots, ensure that the coverage patterns of the sensors overlap along the walkways. This ensures continuous detection as people move through the space, preventing any gaps in sensor coverage.
  • Use a Long Timeout: Given the size and activity level in open offices, use a longer timeout setting (15 or 20 minutes) on the sensors. This prevents the lights from turning off too soon when there’s no movement detected for a brief period.
  • Consider Wall-Mounted Sensors: If the cubicle walls are short, consider using wall-mounted sensors in addition to ceiling-mounted ones. These can provide additional coverage and ensure that all areas of the office are monitored.
  • Avoid Air Vents: Don’t place sensors near air vents. The vibration and airflow can reduce the effectiveness of the sensors. PIR sensors should not be within 4ft of an air vent, and ultrasonic sensors should not be within 6ft of an air vent.
  • Manual Control: Incorporate manual controls that are integrated with the occupancy sensors. This allows for manual override to turn ON/OFF all lighting when necessary.

Wall Sensor Switches

RZ020/021 Motion Sensor Switches

  • 2-wire, 3-wire, 4-wires wiring options
  • Occupancy, Vacancy, Manual ON/OFF
  • Adjustive time delay and ambient light control

Multi-Location Wireless Wall Sensors

RZ020A/021A + RZ022W Kits

  • Hardwired RZ021A/022A occupancy sensor switch
  • Wireless companion switch (RZ022W) for multi-location control

Ceiling Occupancy Sensors

RZ036

  • Hardwired occupancy sensors
  • Auto ON, auto OFF
  • Line voltage and Low voltage available

Core features included:

  • Integrated manual ON/OFF control for all lighting
  • Vacancy sensors (Manual ON only): Lights must be turned on manually only
  • Adjustable time-delay, lighting is automatically turned full OFF after 15mins
  • Additional: multi-location wireless kits to expand the control range without re-wring
  • Additional: multiple wiring options available for both new constructions and retrofit projects.

Meets the Mandatory Provisions

IECC – 2011

C405.2.1 Occupant sensor controls

Occupant sensor controls shall be installed to control lights in the space.

For open offices < 300 sq. ft:

C405.2.1.1 Occupant sensor control functions

  • Manual on or partial on to no more than 50% power.
  • Full off within 20 minutes after all occupants have left the space
  • A manual control to turn off the lights.

For open offices > 300 sq. ft:

  • The general lighting shall be controlled separately in control zones with floor areas not greater than 600 sq. ft within the open plan office space.
  • In each control zone, the general lighting shall be permitted to automatically turn on within the control zone. In other unoccupied zones, the general lighting shall be permitted to turn on to < 20% full power(or unaffected).
  • Automatically turn off general lighting in all control zones within 20 minutes after all occupants have left the space.
  • In each control zone, the general lighting shall turn off or uniformly reduce lighting power to an unoccupied setpoint of < 20% full power within 20 minutes after all occupants have left.

ASHRAE 90.1 – 2022

For open offices in any sizes:

9.4.1.1 a Local control

There shall be one or more manual lighting control device that provides ON and OFF control
of all lighting in the space.

9.4.1.1 b Restricted to manual ON

None of the lighting shall be automatically turned on

9.4.1.1 c Restricted to partial automatic ON

No more than 50% of the lighting power for the general lighting shall be allowed to be automatically turned on

** NOTE: At least one 9.4.1.1 b or 9.4.1.1 c shall be implemented.

9.4.1.1 H Automatic full OFF control

All lighting in the space shall be automatically shut off within 20 minutes of all occupants leaving the space

Additionally, for open offices > 300 sq. ft:

9.4.1.1 g Automatic reduction control

The general lighting power in the space shall be automatically reduced by at least 50% within 15 minutes of all occupants leaving the space.

Title 24 – 2022

For open offices in any sizes:

130.1 (a) Manual area controls.

Each area enclosed by ceiling-height partitions shall provide lighting controls that allow the lighting in that area to be manually turned on and off.

130.1 (c) Shut-OFF Controls.

Additionally, for open offices <250 sq. ft:

130.1 (c) 5. Occupant sensing controls are required for specified offices.

Lighting shall be controlled with occupant sensing controls to automatically shut OFF all of the lighting in 20 minutes or less after the control zone is unoccupied that shall function either as:

  • A. Occupant sensing controls (if 130.1(b) not required to have multi-level lighting controls); or
  • B. Partial-ON occupant sensing controls, or
  • C. Vacancy sensing controls, where all lighting responds to a manual ON input only

Additionally, for open offices > 250 sq. ft:

130.1 (c) 6. Full or partial-OFF occupant sensing controls are required for offices greater than 250 square feet.

In office spaces greater than 250 square feet, general lighting shall be controlled with occupant sensing controls that meet all of the following:

  • Lighting shall be controlled separately in control zones not greater than 600 square feet. For luminaires with an embedded occupant sensor that are capable of reducing power independently from other luminaires, each luminaire can be considered its own control zone
  • The occupant sensing controls shall uniformly reduce lighting power in the control zone by at least 80% full power(or off) in 20 minutes or less after the control zone is unoccupied.
  • The occupant sensing controls shall automatically turn off lighting in ALL control zones in 20 minutes or less after the entire office space is unoccupied
  • When occupancy is detected:
    • in each control zone, lighting shall be allowed to automatically turn on to any level up to full power.
    • in other control zones that are unoccupied, lighting shall operate at no more than 20% full power.

Let us hear you.

Let Rayzeek help design and deliver a bespoke energy-saving lighting solution for you.

    Romanian