Private Offices
Discover energy-saving solutions for private offices with Rayzeek’s occupancy sensor design guide. Learn how to meet energy code requirements while optimizing lighting control for efficiency and comfort.

Optimize Energy Use in Private Offices with Smart Lighting Control
Private offices are individual workspaces, often enclosed by walls and a door, providing a quiet and focused environment for tasks that require concentration. These spaces are typically equipped with overhead lighting and task lighting, which can contribute significantly to the overall energy consumption of a commercial building.
Despite their benefits, private offices often face the issue of lights being left on when the space is unoccupied, leading to unnecessary energy waste. This is particularly problematic given that private offices are not continuously occupied throughout the day, with occupants often leaving for meetings, breaks, or other tasks.
To address this issue, occupancy sensors offer an effective solution. These devices can automatically turn off lights when the office is vacant, significantly reducing energy consumption. By integrating occupancy sensors into private offices, businesses can not only meet energy code requirements but also achieve substantial energy savings and improve their sustainability efforts.
Respecter les codes de l'énergie

L'IECC (International Energy Conservation Code) est un code modèle élaboré par l'ICC (International Code Council) afin d'établir les exigences minimales de conception et de construction pour l'efficacité énergétique des bâtiments. L'IECC est mis à jour tous les trois ans pour intégrer les dernières pratiques et technologies en matière d'économies d'énergie.
IECC, pourquoi vous devriez vous en soucier
L'IECC est largement adopté par les États et les municipalités à travers les États-Unis. L'IECC couvre divers aspects de la consommation d'énergie, notamment l'enveloppe du bâtiment (murs, toits et fenêtres), les systèmes de chauffage et de refroidissement, ainsi que les systèmes d'éclairage.
L'IECC impose des commandes d'éclairage spécifiques, telles que des détecteurs de présence, afin de minimiser le gaspillage d'énergie dans les espaces inoccupés de diverses zones.

La norme ANSI/ASHRAE/IES 90.1, Norme énergétique pour les sites et les bâtiments à l'exclusion des bâtiments résidentiels bas, est une norme énergétique largement reconnue publiée par l'American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).
ASHRAE 90.1, pourquoi vous devriez vous en soucier
La norme ASHRAE 90.1 sert de référence pour les codes énergétiques du bâtiment à travers les États-Unis et constitue une voie de conformité au sein de l'IECC. Elle définit les exigences minimales en matière de performance d'efficacité énergétique des composants des bâtiments commerciaux, y compris les enveloppes de bâtiment, les systèmes CVC, les systèmes de chauffage de l'eau et les systèmes d'éclairage.
La norme ASHRAE 90.1 spécifie les densités de puissance d'éclairage maximales autorisées et les exigences minimales en matière de contrôle de l'éclairage, notamment l'utilisation de détecteurs de présence dans des zones spécifiques.

Titre 24, partie 6 du California Building Standards Code, officiellement connu sous le nom de Building Energy Efficiency Standards for Residential and Nonresidential Buildings, le Titre 24 est administré par la California Energy Commission et est mis à jour périodiquement pour refléter les nouvelles technologies et méthodes d'efficacité énergétique.
Titre 24, pourquoi vous devriez vous en soucier
Le Titre 24 est reconnu pour ses exigences rigoureuses, souvent considérées comme plus strictes que celles de nombreux autres codes énergétiques aux États-Unis. Le Titre 24 impose des normes de performance énergétique strictes pour tous les aspects de la construction de bâtiments, ce qui comprend le chauffage, la ventilation, la climatisation (CVC), le chauffage de l'eau et l'éclairage.
Le Titre 24 exige l'installation de détecteurs de présence qui ajustent l'éclairage en fonction de l'occupation des pièces dans des zones spécifiques des bâtiments commerciaux pour garantir que l'énergie ne soit pas gaspillée.
Adoption des codes énergétiques par État

Développer pour voir le tableau détaillé ↓
| État | Code commercial actuel | Catégorie d'efficacité du code commercial |
|---|---|---|
| Alabama | 90.1-2013 | 90.1-2013 |
| Alaska | Aucun à l'échelle de l'État | Pas de code à l'échelle de l'État |
| Arizona | Autonomie communale | <90.1-2007 |
| Arkansas | IECC 2009 et 90.1-2007 | 90.1-2007 |
| Californie | Normes d'efficacité énergétique des bâtiments de 2022 | 90.1-2019 |
| Colorado | Autonomie communale | Pas de code à l'échelle de l'État |
| Connecticut | IECC 2021 et 90.1-2019 | 90.1-2019 |
| Delaware | IECC 2018 et 90.1-2016 | 90.1-2013 |
| District de Columbia | 90.1-2013^ | 90.1-2019 |
| Floride | IECC 2021 et 90.1-2019^ | 90.1-2016 |
| Géorgie | IECC 2015 et 90.1-2013^ | 90.1-2013 |
| Hawaï | Autonomie communale | 90.1-2013 |
| Idaho | IECC 2018 et 90.1-2016 | 90.1-2013 |
| Illinois | IECC 2021 et 90.1-2019 | 90.1-2019 |
| Indiana | 90.1-2007 | 90.1-2007 |
| Iowa | IECC 2012 et ASHRAE 90.1-2010 | 90.1-2007 |
| Kansas | Autonomie communale | Pas de code à l'échelle de l'État |
| Kentucky | IECC 2012 et ASHRAE 90.1-2010 | 90.1-2007 |
| Louisiane | IECC 2021 et 90.1-2019^ | 90.1-2016 |
| Maine | IECC 2015 et ASHRAE 90.1-2013 | 90.1-2013 |
| Maryland | IECC 2021 et 90.1-2019^ | 90.1-2019 |
| Massachusetts | IECC 2018 et ASHRAE 90.1-2016^ | 90.1-2019 |
| Michigan | IECC 2015 et 90.1-2013^ | 90.1-2013 |
| Minnesota | 90.1-2019^ | 90.1-2019 |
| Mississippi | Aucun à l'échelle de l'État | Pas de code à l'échelle de l'État |
| Missouri | Autonomie communale | Pas de code à l'échelle de l'État |
| Montana | IECC 2021 et 90.1-2019 | 90.1-2019 |
| Nebraska | IECC 2018 et 90.1-2016 | 90.1-2013 |
| Nevada | IECC 2018 et 90.1-2016 | 90.1-2013 |
| Nouveau-Hampshire | IECC 2018 et ASHRAE 90.1-2016^ | 90.1-2013 |
| New Jersey | 90.1-2019 | 90.1-2019 |
| Nouveau-Mexique | IECC 2021 et 90.1-2019^ | 90.1-2019 |
| New York | IECC 2018 et ASHRAE 90.1-2016^ | 90.1-2016 |
| Caroline du Nord | IECC 2015 et 90.1-2013^ | 90.1-2010 |
| Dakota du Nord | Autonomie communale | Pas de code à l'échelle de l'État |
| Ohio | IECC 2021 et 90.1-2019^ | 90.1-2016 |
| Oklahoma | 2006 IECC et 90.1-2004 | <90.1-2007 |
| Oregon | 90.1-2019 | 90.1-2019 |
| Pennsylvanie | IECC 2018 et 90.1-2016 | 90.1-2013 |
| Rhode Island | IECC 2018 et ASHRAE 90.1-2016^ | 90.1-2013 |
| Caroline du Sud | IECC 2009 et 90.1-2007 | 90.1-2007 |
| Dakota du Sud | Autonomie communale | Pas de code à l'échelle de l'État |
| Tennessee | 2021 IECC et 90.1-2013 | 90.1-2007 |
| Texas | IECC 2015 et ASHRAE 90.1-2013 | 90.1-2013 |
| Utah | IECC 2021 et 90.1-2019^ | 90.1-2019 |
| Vermont | IECC 2021 et 90.1-2019^ | 90.1-2019 |
| Virginie | IECC 2021 et 90.1-2019^ | 90.1-2019 |
| Washington | Code de l'énergie de l'État de Washington 2018 | 90.1-2019 |
| Tennessee | IECC 2012 et ASHRAE 90.1-2010 | 90.1-2007 |
| Texas | IECC 2015 et ASHRAE 90.1-2013 | 90.1-2013 |
| Utah | IECC 2021 et 90.1-2019^ | 90.1-2019 |
| Vermont | IECC 2018 et ASHRAE 90.1-2016^ | 90.1-2019 |
| Virginie | IECC 2021 et 90.1-2019^ | 90.1-2019 |
| Washington | Code de l'énergie de l'État de Washington 2018 | 90.1-2019 |
| Gaspésie–Îles-de-la-Madeleine / Virginie-Occidentale | 90.1-2013 | 90.1-2013 |
| Wisconsin | IECC 2015 et 90.1-2013^ | 90.1-2010 |
| Wyoming | Autonomie communale | Pas de code à l'échelle de l'État |
- ^ Lorsqu'un amendement ayant un impact sur l'efficacité énergétique peut être quantifié à l'aide des modèles de bâtiments prototypes du DOE, il a été pris en compte dans l'analyse.
- Pour les États adoptant à la fois l'IECC et la norme 90.1, le code IECC est généralement analysé comme le code en vigueur de l'État dans cette étude, à l'exception des États ayant apporté des amendements importants à l'IECC.
Guide de conception : concepts clés pour les bureaux individuels
La conception d'une solution d'éclairage à efficacité énergétique pour les bureaux individuels implique un positionnement stratégique des détecteurs de présence afin d'assurer une couverture complète de l'espace.

- Sensor Placement: Position the sensor to cover the main areas of activity, such as the desk and the entrance. The sensor should have a clear line of sight to these areas, unobstructed by furniture or other objects. For private offices, wall-mounted sensors or ceiling-mounted sensors can be effective, depending on the room layout and furniture arrangement.
- Coverage of Minor Movements: Ensure that the desk area falls within the minor motion coverage area of the sensor. This means that even small movements, such as typing or turning pages in a book, should be detected by the sensor to prevent the lights from turning off while the space is occupied.
- Avoidance of Obstructions: If using wall-mounted sensors, ensure that tall furniture like bookcases does not block the sensor’s view of the room. Similarly, the sensor’s view should not be blocked by the door when it’s open.
- Entrance Coverage: The sensor should have a clear view of the entrance to detect occupancy as soon as someone enters the room. If the door blocks the sensor’s view when open, consider using an additional sensor to cover the entrance.
- Avoidance of Interference: Sensors should not be mounted close to air vents, as the vibration and air flow can reduce their effectiveness.
- Commande manuelle: Incorporate manual controls for occupants to turn the lights ON/OFF as needed. These controls should be conveniently located, often near the entrance.
Produits et solutions en vedette
Caractéristiques principales incluses :
- Commande manuelle Marche/Arrêt intégrée pour l'ensemble de l'éclairage
- Détecteurs d'absence (allumage manuel uniquement) : les lumières doivent être allumées uniquement de manière manuelle
- Temporisation réglable, l'éclairage s'éteint automatiquement et complètement au bout de 15 min
- En option : kits sans fil multi-emplacements pour étendre la portée de contrôle sans re-câblage
- En option : plusieurs options de câblage disponibles pour les nouvelles constructions et les projets de rénovation.

Conforme aux dispositions obligatoires
IECC – 2011
C405.2.1 Commandes par détecteur de présence
Des commandes par détecteur de présence doivent être installées pour contrôler l'éclairage dans l'espace.
For private/small offices <300 sq. ft:
C405.2.1.1 Fonctions de commande par détecteur de présence
- Allumage manuel ou allumage partiel à pas plus de 50% de puissance.
- Extinction complète dans les 20 minutes suivant le départ de tous les occupants de l'espace
- Une commande manuelle pour éteindre les lumières.
ASHRAE 90.1 – 2022
For private/small/enclosed offices <300 sq. ft:
9.4.1.1 a Commande locale
Il doit y avoir un ou plusieurs dispositifs de commande manuelle de l'éclairage assurant le contrôle MARCHE et ARRÊT
de tout l'éclairage de l'espace.
9.4.1.1 b Limité à l'allumage manuel
Aucun éclairage ne doit s'allumer automatiquement
9.4.1.1 c Restricted to partial automatic ON
No more than 50% of the lighting power for the general lighting shall be allowed to be automatically turned on
** NOTE: At least one 9.4.1.1 b or 9.4.1.1 c shall be implemented.
9.4.1.1 H Commande d'extinction automatique complète
Tout l'éclairage de l'espace doit s'éteindre automatiquement dans les 20 minutes suivant le départ de tous les occupants de l'espace
Titre 24 – 2022
For private/small offices <250 sq. ft:
130.1 (a) Commandes manuelles de zone.
Chaque zone délimitée par des cloisons jusqu'au plafond doit être équipée de commandes d'éclairage permettant d'allumer et d'éteindre manuellement l'éclairage de cette zone.
130.1 (c) Commandes d'extinction.
L'éclairage doit être contrôlé par des détecteurs de présence afin d'éteindre automatiquement tout l'éclairage dans un délai maximal de 20 minutes après que la zone de contrôle n'est plus occupée, fonctionnant soit comme :
- A. Commandes par détecteur de présence (si la section 130.1(b) ne requiert pas de commandes d'éclairage multiniveau) ; ou
- B. Commandes par détecteur de présence avec allumage partiel (Partial-ON), ou
- C. Commandes par détecteur d'absence, où tout l'éclairage réagit uniquement à une commande d'allumage manuel
Faites-nous part de vos besoins.
Laissez Rayzeek vous aider à concevoir et à fournir une solution d'éclairage sur mesure à économie d'énergie.