Maximize Energy Efficiency in Restrooms with Occupancy Sensors

Restrooms in commercial buildings are frequently used spaces that often remain lit even when unoccupied, leading to significant energy wastage. These spaces typically use high-intensity lighting fixtures that consume substantial amounts of energy. The sporadic and unpredictable nature of restroom usage further exacerbates this issue, as lights are often left on unnecessarily during periods of non-use.

Given these factors, the potential for energy savings in restrooms is substantial. By implementing occupancy sensor solutions, commercial facilities can significantly reduce their lighting energy consumption. Occupancy sensors detect the presence or absence of people and automatically control the lighting accordingly, ensuring lights are only on when needed. This not only saves energy but also extends the lifespan of lighting fixtures, leading to additional cost savings.

Atenda aos Códigos de Energia

O International Energy Conservation Code (IECC) é um código modelo desenvolvido pelo International Code Council (ICC) para estabelecer requisitos mínimos de projeto e construção para a eficiência energética em edifícios. O IECC é atualizado a cada três anos para incorporar as mais recentes práticas e tecnologias de conservação de energia.

IECC, Por Que Você Deve Se Importar

O IECC é amplamente adotado por estados e municípios nos Estados Unidos. O IECC abrange vários aspectos do uso de energia, incluindo o envoltório do edifício (paredes, telhados e janelas), sistemas de aquecimento e resfriamento, e sistemas de iluminação.

O IECC exige controles de iluminação específicos, como sensores de presença, para minimizar o desperdício de energia em espaços desocupados em diversas áreas.

A Norma ANSI/ASHRAE/IES 90.1, Padrão de Energia para Locais e Edifícios, Exceto Edifícios Residenciais de Baixa Altura, é uma norma de energia amplamente reconhecida e publicada pela American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).

ASHRAE 90.1, Por Que Você Deve Se Importar

A ASHRAE 90.1 é utilizada como referência para códigos de energia prediais em todos os Estados Unidos e serve como uma via de conformidade dentro do IECC, delineando os requisitos mínimos para o desempenho energeticamente eficiente dos componentes de edifícios comerciais, incluindo envoltórios prediais, sistemas de HVAC, sistemas de aquecimento de água e sistemas de iluminação.

A norma ASHRAE 90.1 especifica as densidades de potência de iluminação máximas permitidas e os requisitos mínimos de controle de iluminação, incluindo o uso de sensores de presença em áreas específicas.

O Title 24, Parte 6 do Código de Padrões de Construção da Califórnia, oficialmente conhecido como Padrões de Eficiência Energética Edilícia para Edifícios Residenciais e Não Residenciais, é administrado pela California Energy Commission e é atualizado periodicamente para refletir novas tecnologias e métodos de eficiência energética.

Title 24, Por Que Você Deve Se Importar

O Title 24 é conhecido por seus requisitos rigorosos, frequentemente considerados mais severos do que os encontrados em muitos outros códigos de energia nos Estados Unidos. O Title 24 exige normas estritas de desempenho energético para todos os aspectos da construção civil, o que inclui aquecimento, ventilação, ar-condicionado (HVAC), aquecimento de água e iluminação.

O Title 24 exige a instalação de sensores de presença que ajustam a iluminação com base na ocupação da sala em áreas específicas de edifícios comerciais para garantir que a energia não seja desperdiçada.

Adoção de Códigos de Energia por Estado

Expanda para ver a tabela detalhada ↓

EstadoCódigo comercial atualCategoria de eficiência do código comercial
Alabama90.1-201390.1-2013
AlascaNenhum em todo o estadoSem código em todo o estado
ArizonaAutonomia municipal<90.1-2007
ArkansasIECC 2009 e 90.1-200790.1-2007
CalifórniaNormas de Eficiência Energética de Edificações de 202290.1-2019
ColoradoAutonomia municipalSem código em todo o estado
Connecticut2021 IECC e 90.1-201990.1-2019
Delaware2018 IECC e 90.1-201690.1-2013
Distrito de Colúmbia90.1-2013^90.1-2019
Flórida2021 IECC e 90.1-2019^90.1-2016
Geórgia2015 IECC e 90.1-2013^90.1-2013
HavaíAutonomia municipal90.1-2013
Idaho2018 IECC e 90.1-201690.1-2013
Illinois2021 IECC e 90.1-201990.1-2019
Indiana90.1-200790.1-2007
Iowa2012 IECC e 90.1-201090.1-2007
KansasAutonomia municipalSem código em todo o estado
Kentucky2012 IECC e 90.1-201090.1-2007
Luisiána2021 IECC e 90.1-2019^90.1-2016
Maine2015 IECC e 90.1-201390.1-2013
Maryland2021 IECC e 90.1-2019^90.1-2019
Massachusetts2018 IECC e 90.1-2016^90.1-2019
Michigan2015 IECC e 90.1-2013^90.1-2013
Minnesota90.1-2019^90.1-2019
MississippiNenhum em todo o estadoSem código em todo o estado
MissouriAutonomia municipalSem código em todo o estado
Montana2021 IECC e 90.1-201990.1-2019
Nebraska2018 IECC e 90.1-201690.1-2013
Nevada2018 IECC e 90.1-201690.1-2013
New Hampshire2018 IECC e 90.1-2016^90.1-2013
New Jersey90.1-201990.1-2019
Novo México2021 IECC e 90.1-2019^90.1-2019
Nova York2018 IECC e 90.1-2016^90.1-2016
Carolina do Norte2015 IECC e 90.1-2013^90.1-2010
Dakota do NorteAutonomia municipalSem código em todo o estado
Ohio2021 IECC e 90.1-2019^90.1-2016
Oklahoma2006 IECC e 90.1-2004<90.1-2007
Oregon90.1-201990.1-2019
Pensilvânia2018 IECC e 90.1-201690.1-2013
Rhode Island2018 IECC e 90.1-2016^90.1-2013
Carolina do SulIECC 2009 e 90.1-200790.1-2007
Dakota do SulAutonomia municipalSem código em todo o estado
Tennessee2021 IECC e 90.1-201390.1-2007
Texas2015 IECC e 90.1-201390.1-2013
Utah2021 IECC e 90.1-2019^90.1-2019
Vermont2021 IECC e 90.1-2019^90.1-2019
Virginia2021 IECC e 90.1-2019^90.1-2019
Washington2018 Washington State Energy Code90.1-2019
Tennessee2012 IECC e 90.1-201090.1-2007
Texas2015 IECC e 90.1-201390.1-2013
Utah2021 IECC e 90.1-2019^90.1-2019
Vermont2018 IECC e 90.1-2016^90.1-2019
Virginia2021 IECC e 90.1-2019^90.1-2019
Washington2018 Washington State Energy Code90.1-2019
West Virginia90.1-201390.1-2013
Wisconsin2015 IECC e 90.1-2013^90.1-2010
WyomingAutonomia municipalSem código em todo o estado
  • ^ When an amendment impacting energy efficiency can be quantified using DOE Prototype Building Models, they were captured in the analysis.
  • For states adopting both IECC and 90.1, the IECC code is usually analyzed as the state current code in this study except for states with extensive amendments to the IECC.

Sensor Solutions

Find out how Rayzeek can solve your energy saving challenges.

Ver todas as ofertas

Design Guide Key Concepts for Restrooms

Designing an energy-efficient lighting control solution for restrooms involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.

By following these guidelines, businesses can create an energy-efficient lighting control solution for restrooms that reduces energy waste, and lowers maintenance costs:

  • Entrance Coverage: Install a wall occupancy sensor near the entrance to detect when someone enters the restroom. This sensor should be positioned high enough to avoid obstructions from the door and should not directly face the entrance to avoid false triggers from movement outside the restroom.
  • Stall Coverage: Depending on customer preference for privacy, stalls can either be covered by a sensor or not. If stalls are not covered by a sensor, program a longer timeout (15 or 20 minutes) to prevent lights from turning off when someone is in the stall. If individual stall sensors are used, they should be installed in such a way that they do not detect movement outside the stall to avoid false triggers.
  • Sink and Mirror Area: Install a ceiling occupancy sensor above the sink and mirror area. This sensor should be positioned to cover the entire area, ensuring that lights remain on when someone is using the sink or mirror.
  • Avoidance of Air Vents: Do not mount sensors close to air vents, as the vibration and air flow can reduce the effectiveness of the sensor. PIR sensors should not be within 4ft of an air vent, and ultrasonic sensors should not be within 6ft of an air vent.
  • Manual Control: Integrate manual control to turn ON/OFF all lighting with our occupancy/vacancy sensors. This allows for manual override of the lighting system if necessary.

Wall Sensor Switches

RZ020/021 Motion Sensor Switches

  • 2-wire, 3-wire, 4-wires wiring options
  • Occupancy, Vacancy, Manual ON/OFF
  • Adjustive time delay and ambient light control

Multi-Location Wireless Wall Sensors

RZ020A/021A + RZ022W Kits

  • Hardwired RZ021A/022A occupancy sensor switch
  • Wireless companion switch (RZ022W) for multi-location control

Ceiling Occupancy Sensors

RZ036

  • Hardwired occupancy sensors
  • Auto ON, auto OFF
  • Line voltage and Low voltage available

Core features included:

  • Integrated manual ON/OFF control for all lighting
  • Vacancy sensors (Manual ON only): Lights must be turned on manually only
  • Adjustable time-delay, lighting is automatically turned full OFF after 15mins
  • Additional: multi-location wireless kits to expand the control range without re-wring
  • Additional: multiple wiring options available for both new constructions and retrofit projects.

Meets the Mandatory Provisions

IECC – 2011

C405.2.1 Occupant sensor controls

Occupant sensor controls shall be installed to control lights in the space.

C405.2.1.1 Occupant sensor control functions

  • Manual on or partial on to no more than 50% power.
  • Full off within 20 minutes after all occupants have left the space
  • A manual control to turn off the lights.

**Full automatic-on controls with no manual control are permitted in restrooms where manual operation would endanger occupant safety or security.

ASHRAE 90.1 – 2022

Restrooms shall also be controlled by occupant sensors.

9.4.1.1 H Automatic full OFF control

All lighting in the space shall be automatically shut off within 20 minutes of all occupants leaving the space

Title 24 – 2022

130.1 (a) Manual area controls.

Each area enclosed by ceiling-height partitions shall provide lighting controls that allow the lighting in that area to be manually turned on and off.

** Restrooms having two or more stalls may use a manual control not accessible to unauthorized personnel.

130.1 (c) Shut-OFF Controls.

Lighting shall be controlled with occupant sensing controls to automatically shut OFF all of the lighting in 20 minutes or less after the control zone is unoccupied that shall function either as:

  • A. Occupant sensing controls (if 130.1(b) not required to have multi-level lighting controls); or
  • B. Partial-ON occupant sensing controls, or
  • C. Vacancy sensing controls, where all lighting responds to a manual ON input only