Corridors
Discover the energy-saving potential of corridors with Rayzeek’s occupancy sensor design guide. Uncover the power of automated lighting control in your commercial building’s passageways.

Lighting the Way to Energy Efficiency in Corridors
Corridors, whether in commercial buildings, educational institutions, or healthcare facilities, are high-traffic areas that often remain illuminated throughout the day, leading to significant energy consumption. These spaces typically use fluorescent or LED lighting, which, while energy-efficient, can still contribute to high energy costs when left on unnecessarily.
The challenge lies in the fact that corridors are intermittently occupied, with periods of high foot traffic interspersed with times of vacancy. Traditional manual lighting controls can lead to lights being left on during these vacant periods, resulting in unnecessary energy waste.
By integrating our occupancy sensors into your corridor lighting system, you can ensure that lights are only on when needed, saving energy and reducing costs. Our sensors, including wall and ceiling-mounted options, are designed to comply with US Energy Codes, making them an essential component in meeting energy efficiency requirements for commercial buildings.
Atenda aos Códigos de Energia

O International Energy Conservation Code (IECC) é um código modelo desenvolvido pelo International Code Council (ICC) para estabelecer requisitos mínimos de projeto e construção para a eficiência energética em edifícios. O IECC é atualizado a cada três anos para incorporar as mais recentes práticas e tecnologias de conservação de energia.
IECC, Por Que Você Deve Se Importar
O IECC é amplamente adotado por estados e municípios nos Estados Unidos. O IECC abrange vários aspectos do uso de energia, incluindo o envoltório do edifício (paredes, telhados e janelas), sistemas de aquecimento e resfriamento, e sistemas de iluminação.
O IECC exige controles de iluminação específicos, como sensores de presença, para minimizar o desperdício de energia em espaços desocupados em diversas áreas.

A Norma ANSI/ASHRAE/IES 90.1, Padrão de Energia para Locais e Edifícios, Exceto Edifícios Residenciais de Baixa Altura, é uma norma de energia amplamente reconhecida e publicada pela American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).
ASHRAE 90.1, Por Que Você Deve Se Importar
A ASHRAE 90.1 é utilizada como referência para códigos de energia prediais em todos os Estados Unidos e serve como uma via de conformidade dentro do IECC, delineando os requisitos mínimos para o desempenho energeticamente eficiente dos componentes de edifícios comerciais, incluindo envoltórios prediais, sistemas de HVAC, sistemas de aquecimento de água e sistemas de iluminação.
A norma ASHRAE 90.1 especifica as densidades de potência de iluminação máximas permitidas e os requisitos mínimos de controle de iluminação, incluindo o uso de sensores de presença em áreas específicas.

O Title 24, Parte 6 do Código de Padrões de Construção da Califórnia, oficialmente conhecido como Padrões de Eficiência Energética Edilícia para Edifícios Residenciais e Não Residenciais, é administrado pela California Energy Commission e é atualizado periodicamente para refletir novas tecnologias e métodos de eficiência energética.
Title 24, Por Que Você Deve Se Importar
O Title 24 é conhecido por seus requisitos rigorosos, frequentemente considerados mais severos do que os encontrados em muitos outros códigos de energia nos Estados Unidos. O Title 24 exige normas estritas de desempenho energético para todos os aspectos da construção civil, o que inclui aquecimento, ventilação, ar-condicionado (HVAC), aquecimento de água e iluminação.
O Title 24 exige a instalação de sensores de presença que ajustam a iluminação com base na ocupação da sala em áreas específicas de edifícios comerciais para garantir que a energia não seja desperdiçada.
Adoção de Códigos de Energia por Estado

Expanda para ver a tabela detalhada ↓
| Estado | Código comercial atual | Categoria de eficiência do código comercial |
|---|---|---|
| Alabama | 90.1-2013 | 90.1-2013 |
| Alasca | Nenhum em todo o estado | Sem código em todo o estado |
| Arizona | Autonomia municipal | <90.1-2007 |
| Arkansas | IECC 2009 e 90.1-2007 | 90.1-2007 |
| Califórnia | Normas de Eficiência Energética de Edificações de 2022 | 90.1-2019 |
| Colorado | Autonomia municipal | Sem código em todo o estado |
| Connecticut | 2021 IECC e 90.1-2019 | 90.1-2019 |
| Delaware | 2018 IECC e 90.1-2016 | 90.1-2013 |
| Distrito de Colúmbia | 90.1-2013^ | 90.1-2019 |
| Flórida | 2021 IECC e 90.1-2019^ | 90.1-2016 |
| Geórgia | 2015 IECC e 90.1-2013^ | 90.1-2013 |
| Havaí | Autonomia municipal | 90.1-2013 |
| Idaho | 2018 IECC e 90.1-2016 | 90.1-2013 |
| Illinois | 2021 IECC e 90.1-2019 | 90.1-2019 |
| Indiana | 90.1-2007 | 90.1-2007 |
| Iowa | 2012 IECC e 90.1-2010 | 90.1-2007 |
| Kansas | Autonomia municipal | Sem código em todo o estado |
| Kentucky | 2012 IECC e 90.1-2010 | 90.1-2007 |
| Luisiána | 2021 IECC e 90.1-2019^ | 90.1-2016 |
| Maine | 2015 IECC e 90.1-2013 | 90.1-2013 |
| Maryland | 2021 IECC e 90.1-2019^ | 90.1-2019 |
| Massachusetts | 2018 IECC e 90.1-2016^ | 90.1-2019 |
| Michigan | 2015 IECC e 90.1-2013^ | 90.1-2013 |
| Minnesota | 90.1-2019^ | 90.1-2019 |
| Mississippi | Nenhum em todo o estado | Sem código em todo o estado |
| Missouri | Autonomia municipal | Sem código em todo o estado |
| Montana | 2021 IECC e 90.1-2019 | 90.1-2019 |
| Nebraska | 2018 IECC e 90.1-2016 | 90.1-2013 |
| Nevada | 2018 IECC e 90.1-2016 | 90.1-2013 |
| New Hampshire | 2018 IECC e 90.1-2016^ | 90.1-2013 |
| New Jersey | 90.1-2019 | 90.1-2019 |
| Novo México | 2021 IECC e 90.1-2019^ | 90.1-2019 |
| Nova York | 2018 IECC e 90.1-2016^ | 90.1-2016 |
| Carolina do Norte | 2015 IECC e 90.1-2013^ | 90.1-2010 |
| Dakota do Norte | Autonomia municipal | Sem código em todo o estado |
| Ohio | 2021 IECC e 90.1-2019^ | 90.1-2016 |
| Oklahoma | 2006 IECC e 90.1-2004 | <90.1-2007 |
| Oregon | 90.1-2019 | 90.1-2019 |
| Pensilvânia | 2018 IECC e 90.1-2016 | 90.1-2013 |
| Rhode Island | 2018 IECC e 90.1-2016^ | 90.1-2013 |
| Carolina do Sul | IECC 2009 e 90.1-2007 | 90.1-2007 |
| Dakota do Sul | Autonomia municipal | Sem código em todo o estado |
| Tennessee | 2021 IECC e 90.1-2013 | 90.1-2007 |
| Texas | 2015 IECC e 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC e 90.1-2019^ | 90.1-2019 |
| Vermont | 2021 IECC e 90.1-2019^ | 90.1-2019 |
| Virginia | 2021 IECC e 90.1-2019^ | 90.1-2019 |
| Washington | 2018 Washington State Energy Code | 90.1-2019 |
| Tennessee | 2012 IECC e 90.1-2010 | 90.1-2007 |
| Texas | 2015 IECC e 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC e 90.1-2019^ | 90.1-2019 |
| Vermont | 2018 IECC e 90.1-2016^ | 90.1-2019 |
| Virginia | 2021 IECC e 90.1-2019^ | 90.1-2019 |
| Washington | 2018 Washington State Energy Code | 90.1-2019 |
| West Virginia | 90.1-2013 | 90.1-2013 |
| Wisconsin | 2015 IECC e 90.1-2013^ | 90.1-2010 |
| Wyoming | Autonomia municipal | Sem código em todo o estado |
- ^ When an amendment impacting energy efficiency can be quantified using DOE Prototype Building Models, they were captured in the analysis.
- For states adopting both IECC and 90.1, the IECC code is usually analyzed as the state current code in this study except for states with extensive amendments to the IECC.
Design Guide Key Concepts for Corridors
Designing an energy-efficient lighting control solution for corridors involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.

In a corridor, the primary goal is to ensure safe and well-lit passage for occupants while minimizing energy waste and all potential access points and the entire length of the corridor are covered by the sensors. Here are some design considerations:
- Posicionamento do sensor: For long corridors, multiple sensors may be required. Ceiling-mounted sensors can be placed at regular intervals along the length of the corridor to ensure comprehensive coverage. Alternatively, wall-mounted sensors can be placed at both ends of the corridor, with their coverage areas overlapping in the middle to avoid any blind spots. Also, consider the height and range of the sensors to ensure they can effectively detect movement across the entire corridor.
- Tipo de Sensor: Depending on the ceiling height and the presence of any potential obstructions, either ceiling-mounted or wall-mounted sensors can be used. Rayzeek’s ceiling sensors offer automatic ON and full OFF functionality, while our wall sensors provide manual ON and full OFF functionality.
- Additional Manual Controls: In addition to occupancy sensors, manual controls can be integrated for instances where manual override is necessary. These controls can be conveniently located near entrances or exits.
- Avoiding False Triggers: Sensors should be placed such that they do not directly face doors leading to other spaces, external light sources and air vents, as this could lead to false triggers when movement is detected in these adjacent spaces.
Featured Products & Solutions
Core features included:
- Integrated manual ON/OFF control for all lighting
- Vacancy sensors (Manual ON only): Lights must be turned on manually only
- Adjustable time-delay, lighting is automatically turned full OFF after 15mins
- Additional: multi-location wireless kits to expand the control range without re-wring
- Additional: multiple wiring options available for both new constructions and retrofit projects.

Meets the Mandatory Provisions
IECC – 2011
C405.2.1 Occupant sensor controls
Occupant sensor controls shall be installed to control lights in the space.
C405.2.1.1 Occupant sensor control functions
- Manual on or partial on to no more than 50% power.
- Full off within 20 minutes after all occupants have left the space
- A manual control to turn off the lights.
Full automatic-on controls with no manual control are permitted in corridors where manual operation would endanger occupant safety or security.
C405.2.1.4 Occupant sensor control function in corridors.
Occupant sensor controls in corridors shall uniformly reduce lighting power to an occupied setpoint not more than 50 percent offull power within 20 minutes after all occupants have left the space.
Exception: Corridors provided with less than two footcandles of illumination on the floor at the darkest point with all lights on.
ASHRAE 90.1 – 2022
9.4.1.1 a Local control
There shall be one or more manual lighting control device that provides ON and OFF control
of all lighting in the space.
9.4.1.1 g Automatic reduction control
The general lighting power in the space shall be automatically reduced by at least 50% within 15 minutes of all occupants leaving the space.
9.4.1.1 h Automatic full OFF control
All lighting in the space shall be automatically shut off within 15 minutes of all occupants leaving the space.
9.4.1.1 i Scheduled shutoff
All lighting in the space shall be automatically shut off during periods when the space is scheduled to be unoccupied.
** NOTE: At least one 9.4.1.1 h or 9.4.1.1 i shall be implemented.
Title 24 – 2022
130.1 (a) Manual area controls.
Each area enclosed by ceiling-height partitions shall provide lighting controls that allow the lighting in that area to be manually turned on and off.
130.1 (c) Shut-OFF Controls.
In corridors, lighting shall be controlled by Full or partial-OFF occupant sensing controls that separately reduce the lighting power in each space by at least 50 percent when the space is unoccupied. The occupant sensing controls shall be capable of automatically turning the lighting fully ON only in the separately controlled space, and shall be automatically activated from all designed paths of egress.
Let us hear you.