Maximize Energy Efficiency in Storage Rooms with Occupancy Sensors
Storage rooms, often overlooked, are integral parts of commercial buildings. These spaces are typically filled with shelves, boxes, and various items, and are used for storing supplies, equipment, or archived documents. Lighting in these areas is crucial for visibility and safety, but it can also be a significant source of energy waste. Traditional lighting systems in storage rooms are often left on unnecessarily, leading to high energy consumption and costs.
Moreover, storage rooms are usually equipped with fluorescent or LED lights, which, while energy-efficient, can still consume a considerable amount of power when left on for extended periods. The sporadic and unpredictable nature of storage room usage further exacerbates this issue, as lights are often left on even when the room is unoccupied, leading to unnecessary energy waste.
This energy wastage can be mitigated by using occupancy sensors. These devices automatically control lighting based on the presence or absence of people, ensuring lights are only on when needed. By installing occupancy sensors in storage rooms, businesses can significantly reduce their energy consumption, lower their utility bills, and contribute to a more sustainable environment.
Atenda aos Códigos de Energia

O International Energy Conservation Code (IECC) é um código modelo desenvolvido pelo International Code Council (ICC) para estabelecer requisitos mínimos de projeto e construção para a eficiência energética em edifícios. O IECC é atualizado a cada três anos para incorporar as mais recentes práticas e tecnologias de conservação de energia.
IECC, Por Que Você Deve Se Importar
O IECC é amplamente adotado por estados e municípios nos Estados Unidos. O IECC abrange vários aspectos do uso de energia, incluindo o envoltório do edifício (paredes, telhados e janelas), sistemas de aquecimento e resfriamento, e sistemas de iluminação.
O IECC exige controles de iluminação específicos, como sensores de presença, para minimizar o desperdício de energia em espaços desocupados em diversas áreas.

A Norma ANSI/ASHRAE/IES 90.1, Padrão de Energia para Locais e Edifícios, Exceto Edifícios Residenciais de Baixa Altura, é uma norma de energia amplamente reconhecida e publicada pela American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).
ASHRAE 90.1, Por Que Você Deve Se Importar
A ASHRAE 90.1 é utilizada como referência para códigos de energia prediais em todos os Estados Unidos e serve como uma via de conformidade dentro do IECC, delineando os requisitos mínimos para o desempenho energeticamente eficiente dos componentes de edifícios comerciais, incluindo envoltórios prediais, sistemas de HVAC, sistemas de aquecimento de água e sistemas de iluminação.
A norma ASHRAE 90.1 especifica as densidades de potência de iluminação máximas permitidas e os requisitos mínimos de controle de iluminação, incluindo o uso de sensores de presença em áreas específicas.

O Title 24, Parte 6 do Código de Padrões de Construção da Califórnia, oficialmente conhecido como Padrões de Eficiência Energética Edilícia para Edifícios Residenciais e Não Residenciais, é administrado pela California Energy Commission e é atualizado periodicamente para refletir novas tecnologias e métodos de eficiência energética.
Title 24, Por Que Você Deve Se Importar
O Title 24 é conhecido por seus requisitos rigorosos, frequentemente considerados mais severos do que os encontrados em muitos outros códigos de energia nos Estados Unidos. O Title 24 exige normas estritas de desempenho energético para todos os aspectos da construção civil, o que inclui aquecimento, ventilação, ar-condicionado (HVAC), aquecimento de água e iluminação.
O Title 24 exige a instalação de sensores de presença que ajustam a iluminação com base na ocupação da sala em áreas específicas de edifícios comerciais para garantir que a energia não seja desperdiçada.
Adoção de Códigos de Energia por Estado

Expanda para ver a tabela detalhada ↓
| Estado | Código comercial atual | Categoria de eficiência do código comercial |
|---|---|---|
| Alabama | 90.1-2013 | 90.1-2013 |
| Alasca | Nenhum em todo o estado | Sem código em todo o estado |
| Arizona | Autonomia municipal | <90.1-2007 |
| Arkansas | IECC 2009 e 90.1-2007 | 90.1-2007 |
| Califórnia | Normas de Eficiência Energética de Edificações de 2022 | 90.1-2019 |
| Colorado | Autonomia municipal | Sem código em todo o estado |
| Connecticut | 2021 IECC e 90.1-2019 | 90.1-2019 |
| Delaware | 2018 IECC e 90.1-2016 | 90.1-2013 |
| Distrito de Colúmbia | 90.1-2013^ | 90.1-2019 |
| Flórida | 2021 IECC e 90.1-2019^ | 90.1-2016 |
| Geórgia | 2015 IECC e 90.1-2013^ | 90.1-2013 |
| Havaí | Autonomia municipal | 90.1-2013 |
| Idaho | 2018 IECC e 90.1-2016 | 90.1-2013 |
| Illinois | 2021 IECC e 90.1-2019 | 90.1-2019 |
| Indiana | 90.1-2007 | 90.1-2007 |
| Iowa | 2012 IECC e 90.1-2010 | 90.1-2007 |
| Kansas | Autonomia municipal | Sem código em todo o estado |
| Kentucky | 2012 IECC e 90.1-2010 | 90.1-2007 |
| Luisiána | 2021 IECC e 90.1-2019^ | 90.1-2016 |
| Maine | 2015 IECC e 90.1-2013 | 90.1-2013 |
| Maryland | 2021 IECC e 90.1-2019^ | 90.1-2019 |
| Massachusetts | 2018 IECC e 90.1-2016^ | 90.1-2019 |
| Michigan | 2015 IECC e 90.1-2013^ | 90.1-2013 |
| Minnesota | 90.1-2019^ | 90.1-2019 |
| Mississippi | Nenhum em todo o estado | Sem código em todo o estado |
| Missouri | Autonomia municipal | Sem código em todo o estado |
| Montana | 2021 IECC e 90.1-2019 | 90.1-2019 |
| Nebraska | 2018 IECC e 90.1-2016 | 90.1-2013 |
| Nevada | 2018 IECC e 90.1-2016 | 90.1-2013 |
| New Hampshire | 2018 IECC e 90.1-2016^ | 90.1-2013 |
| New Jersey | 90.1-2019 | 90.1-2019 |
| Novo México | 2021 IECC e 90.1-2019^ | 90.1-2019 |
| Nova York | 2018 IECC e 90.1-2016^ | 90.1-2016 |
| Carolina do Norte | 2015 IECC e 90.1-2013^ | 90.1-2010 |
| Dakota do Norte | Autonomia municipal | Sem código em todo o estado |
| Ohio | 2021 IECC e 90.1-2019^ | 90.1-2016 |
| Oklahoma | 2006 IECC e 90.1-2004 | <90.1-2007 |
| Oregon | 90.1-2019 | 90.1-2019 |
| Pensilvânia | 2018 IECC e 90.1-2016 | 90.1-2013 |
| Rhode Island | 2018 IECC e 90.1-2016^ | 90.1-2013 |
| Carolina do Sul | IECC 2009 e 90.1-2007 | 90.1-2007 |
| Dakota do Sul | Autonomia municipal | Sem código em todo o estado |
| Tennessee | 2021 IECC e 90.1-2013 | 90.1-2007 |
| Texas | 2015 IECC e 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC e 90.1-2019^ | 90.1-2019 |
| Vermont | 2021 IECC e 90.1-2019^ | 90.1-2019 |
| Virginia | 2021 IECC e 90.1-2019^ | 90.1-2019 |
| Washington | 2018 Washington State Energy Code | 90.1-2019 |
| Tennessee | 2012 IECC e 90.1-2010 | 90.1-2007 |
| Texas | 2015 IECC e 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC e 90.1-2019^ | 90.1-2019 |
| Vermont | 2018 IECC e 90.1-2016^ | 90.1-2019 |
| Virginia | 2021 IECC e 90.1-2019^ | 90.1-2019 |
| Washington | 2018 Washington State Energy Code | 90.1-2019 |
| West Virginia | 90.1-2013 | 90.1-2013 |
| Wisconsin | 2015 IECC e 90.1-2013^ | 90.1-2010 |
| Wyoming | Autonomia municipal | Sem código em todo o estado |
- ^ When an amendment impacting energy efficiency can be quantified using DOE Prototype Building Models, they were captured in the analysis.
- For states adopting both IECC and 90.1, the IECC code is usually analyzed as the state current code in this study except for states with extensive amendments to the IECC.
Conceitos-chave do guia de projeto para escritórios individuais
Projetar uma solução de controle de iluminação energeticamente eficiente para escritórios individuais envolve o posicionamento estratégico de sensores de presença para garantir a cobertura completa do espaço.

In a storage room, the primary areas that require lighting are the main walkways and the individual aisles between shelves. Here are some guidelines to follow:
- Main Walkways: Install ceiling occupancy sensors at regular intervals along the main walkways. These sensors should be set to Auto ON and Full OFF mode, ensuring that lights turn on automatically when someone enters the walkway and turn off when the area is vacant.
- Individual Aisles: For individual aisles between shelves, consider installing wall occupancy sensors at the entrance of each aisle. These sensors can detect when someone enters the aisle and turn on the lights accordingly. Given the sporadic usage of these aisles, the sensors should be set to Manual ON and Full OFF mode. This means that the lights will only turn on when manually switched on but will turn off automatically when the aisle is vacant.
- Entrance Area: The entrance area of the storage room should have a wall sensor switch that allows manual control of all lighting in the room. This switch can be used to turn all lights on or off as needed, providing an additional layer of control.
- Sensor Placement Considerations: When placing sensors, ensure they are not located near air vents or other sources of movement that could trigger false positives. Also, ensure that the sensors’ field of view is not obstructed by shelves or stored items.
- Sensor Height: Consider the height of the sensor installation. Sensors should be installed at a height that allows for optimal coverage of the room, taking into account the height of stored items.
- Manual Control: Incorporate manual controls to allow users to turn ON/OFF all lighting when needed. This can be particularly useful in storage rooms where lighting may be required for extended periods during inventory checks or reorganization tasks.
Featured Products & Solutions
Core features included:
- Integrated manual ON/OFF control for all lighting
- Vacancy sensors (Manual ON only): Lights must be turned on manually only
- Adjustable time-delay, lighting is automatically turned full OFF after 15mins
- Additional: multi-location wireless kits to expand the control range without re-wring
- Additional: multiple wiring options available for both new constructions and retrofit projects.

Meets the Mandatory Provisions
IECC – 2011
C405.2.1 Occupant sensor controls
Occupant sensor controls shall be installed to control lights in the space.
C405.2.1.1 Occupant sensor control functions
- Manual on or partial on to no more than 50% power.
- Full off within 20 minutes after all occupants have left the space
- A manual control to turn off the lights.
ASHRAE 90.1 – 2022
9.4.1.1 a Local control
There shall be one or more manual lighting control device that provides ON and OFF control
of all lighting in the space.
9.4.1.1 H Automatic full OFF control
All lighting in the space shall be automatically shut off within 20 minutes of all occupants leaving the space
Additionally, for storage rooms with sizes <50 ft2:
9.4.1.1 b Restricted to manual ON
None of the lighting shall be automatically turned on
Title 24 – 2022
130.1 (a) Manual area controls.
Each area enclosed by ceiling-height partitions shall provide lighting controls that allow the lighting in that area to be manually turned on and off.
130.1 (c) Shut-OFF Controls.
Lighting shall be controlled with occupant sensing controls to automatically shut OFF all of the lighting in 20 minutes or less after the control zone is unoccupied that shall function either as:
- A. Occupant sensing controls (if 130.1(b) not required to have multi-level lighting controls); or
- B. Partial-ON occupant sensing controls, or
- C. Vacancy sensing controls, where all lighting responds to a manual ON input only