Restrooms

Explore our energy-saving guide for restrooms, designed to help you understand and implement occupancy sensor solutions for efficient lighting control in compliance with US Energy Codes.

Maximize Energy Efficiency in Restrooms with Occupancy Sensors

Restrooms in commercial buildings are frequently used spaces that often remain lit even when unoccupied, leading to significant energy wastage. These spaces typically use high-intensity lighting fixtures that consume substantial amounts of energy. The sporadic and unpredictable nature of restroom usage further exacerbates this issue, as lights are often left on unnecessarily during periods of non-use.

Given these factors, the potential for energy savings in restrooms is substantial. By implementing occupancy sensor solutions, commercial facilities can significantly reduce their lighting energy consumption. Occupancy sensors detect the presence or absence of people and automatically control the lighting accordingly, ensuring lights are only on when needed. This not only saves energy but also extends the lifespan of lighting fixtures, leading to additional cost savings.

עמידה בתקני האנרגיה

התקן הבינלאומי לשימור אנרגיה (IECC) הוא תקן מודל שפותח על ידי מועצת התקנים הבינלאומית (ICC) כדי לקבוע דרישות תכנון ובנייה מינימליות ליעילות אנרגטית במבנים. ה-IECC מתעדכן מדי שלוש שנים כדי לשלב את שיטות העבודה והטכנולוגיות העדכניות ביותר בתחום שימור האנרגיה.

IECC, מדוע זה צריך לעניין אותך

תקן IECC מאומץ במידה רבה על ידי מדינות ורשויות מקומיות ברחבי ארצות הברית. IECC מכסה היבטים שונים של שימוש באנרגיה, לרבות מעטפת הבניין (קירות, גגות וחלונות), מערכות חימום וקירור, ומערכות תאורה.

תקן IECC מחייב בקרות תאורה ספציפיות, כגון חיישני תפוסה, כדי למזער בזבוז אנרגיה בחללים לא מאוכלסים באזורים שונים.

תקן ANSI/ASHRAE/IES 90.1, תקן אנרגיה לאתרים ולמבנים למעט מבני מגורים נמוכים, הוא תקן אנרגיה מוכר גלובלית המפורסם על ידי האגודה האמריקאית למהנדסי חימום, קירור ומזוג אוויר (ASHRAE).

ASHRAE 90.1, מדוע זה צריך לעניין אותך

תקן ASHRAE 90.1 משמש כנקודת התייחסות (מדד) לתקני אנרגיה בבנייה ברחבי ארצות הברית ומשמש כמסלול ציות במסגרת ה-IECC, המתווה דרישות מינימום לביצועים יעילים באנרגיה של רכיבי מבנים מסחריים, כולל מעטפת הבניין, מערכות מיזוג אוויר (HVAC), מערכות חימום מים ומערכות תאורה.

תקן ASHRAE 90.1 מגדיר צפיפות הספק תאורה מרבית מותרת ודרישות מינימום לבקרת תאורה, כולל שימוש בחיישני תפוסה באזורים ספציפיים.

Title 24, חלק 6 של קוד תקני הבנייה של קליפורניה, הידוע רשמית כתקני יעילות אנרגטית בבנייה למבני מגורים ושאינם למגורים, מנוהל על ידי נציבות האנרגיה של קליפורניה (CEC) ומתעדכן תקופתית כדי לשקף טכנולוגיות ושיטות חדשות ליעילות אנרגטית.

Title 24, מדוע זה צריך לעניין אותך

תקן Title 24 ידוע בדרישות המחמירות שלו, הנחשבות לרוב למחמירות יותר מאלו שנמצאות בתקני אנרגיה רבים אחרים ברחבי ארצות הברית. Title 24 מחייב תקני ביצועים אנרגטיים קפדניים לכל היבטי הבנייה, הכוללים חימום, אוורור, מיזוג אוויר (HVAC), חימום מים ותאורה.

תקן Title 24 מחייב התקנת חיישני תפוסה המתאימים את התאורה בהתבסס על תפוסת החדר באזורים ספציפיים של מבנים מסחריים כדי להבטיח שאנרגיה לא תתבזבז.

אימוץ תקני אנרגיה לפי מדינה

התרחבו כדי לצפות בטבלה המפורטת ↓

מדינהתקן מסחרי נוכחיקטגוריית יעילות תקן מסחרי
אלבמה90.1-201390.1-2013
אלסקהאין תקן כלל-מדינתיאין תקן כלל-מדינתי
אריזונהשלטון מקומי (Home rule)<90.1-2007
ארקנסו2009 IECC ו-90.1-200790.1-2007
קליפורניהתקני יעילות אנרגטית לבנייה 202290.1-2019
קולורדושלטון מקומי (Home rule)אין תקן כלל-מדינתי
קונטיקט2021 IECC ו-90.1-201990.1-2019
דלאוור2018 IECC ו-90.1-201690.1-2013
מחוז קולומביה90.1-2013^90.1-2019
פלורידה2021 IECC ו-90.1-2019^90.1-2016
ג'ורג'יה2015 IECC ו-90.1-2013^90.1-2013
הוואישלטון מקומי (Home rule)90.1-2013
איידהו2018 IECC ו-90.1-201690.1-2013
אילינוי2021 IECC ו-90.1-201990.1-2019
אינדיאנה90.1-200790.1-2007
איווה2012 IECC ו-90.1-201090.1-2007
קנזסשלטון מקומי (Home rule)אין תקן כלל-מדינתי
קנטקי2012 IECC ו-90.1-201090.1-2007
לואיזיאנה2021 IECC ו-90.1-2019^90.1-2016
מיין2015 IECC ו-90.1-201390.1-2013
מרילנד2021 IECC ו-90.1-2019^90.1-2019
מסצ'וסטס2018 IECC ו-90.1-2016^90.1-2019
מישיגן2015 IECC ו-90.1-2013^90.1-2013
מינסוטה90.1-2019^90.1-2019
מיסיסיפיאין תקן כלל-מדינתיאין תקן כלל-מדינתי
מיזורישלטון מקומי (Home rule)אין תקן כלל-מדינתי
מונטנה2021 IECC ו-90.1-201990.1-2019
נברסקה2018 IECC ו-90.1-201690.1-2013
נבאדה2018 IECC ו-90.1-201690.1-2013
ניו המפשייר2018 IECC ו-90.1-2016^90.1-2013
ניו ג'רזי90.1-201990.1-2019
ניו מקסיקו2021 IECC ו-90.1-2019^90.1-2019
ניו יורק2018 IECC ו-90.1-2016^90.1-2016
צפון קרוליינה2015 IECC ו-90.1-2013^90.1-2010
צפון דקוטהשלטון מקומי (Home rule)אין תקן כלל-מדינתי
אוהיו2021 IECC ו-90.1-2019^90.1-2016
אוקלהומה2006 IECC and 90.1-2004<90.1-2007
Oregon90.1-201990.1-2019
Pennsylvania2018 IECC ו-90.1-201690.1-2013
Rhode Island2018 IECC ו-90.1-2016^90.1-2013
South Carolina2009 IECC ו-90.1-200790.1-2007
South Dakotaשלטון מקומי (Home rule)אין תקן כלל-מדינתי
Tennessee2021 IECC and 90.1-201390.1-2007
Texas2015 IECC ו-90.1-201390.1-2013
Utah2021 IECC ו-90.1-2019^90.1-2019
Vermont2021 IECC ו-90.1-2019^90.1-2019
Virginia2021 IECC ו-90.1-2019^90.1-2019
Washington2018 Washington State Energy Code90.1-2019
Tennessee2012 IECC ו-90.1-201090.1-2007
Texas2015 IECC ו-90.1-201390.1-2013
Utah2021 IECC ו-90.1-2019^90.1-2019
Vermont2018 IECC ו-90.1-2016^90.1-2019
Virginia2021 IECC ו-90.1-2019^90.1-2019
Washington2018 Washington State Energy Code90.1-2019
West Virginia90.1-201390.1-2013
Wisconsin2015 IECC ו-90.1-2013^90.1-2010
Wyomingשלטון מקומי (Home rule)אין תקן כלל-מדינתי
  • ^ When an amendment impacting energy efficiency can be quantified using DOE Prototype Building Models, they were captured in the analysis.
  • For states adopting both IECC and 90.1, the IECC code is usually analyzed as the state current code in this study except for states with extensive amendments to the IECC.

Sensor Solutions

Find out how Rayzeek can solve your energy saving challenges.

הצג את כל ההצעות

Design Guide Key Concepts for Restrooms

Designing an energy-efficient lighting control solution for restrooms involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.

By following these guidelines, businesses can create an energy-efficient lighting control solution for restrooms that reduces energy waste, and lowers maintenance costs:

  • Entrance Coverage: Install a wall occupancy sensor near the entrance to detect when someone enters the restroom. This sensor should be positioned high enough to avoid obstructions from the door and should not directly face the entrance to avoid false triggers from movement outside the restroom.
  • Stall Coverage: Depending on customer preference for privacy, stalls can either be covered by a sensor or not. If stalls are not covered by a sensor, program a longer timeout (15 or 20 minutes) to prevent lights from turning off when someone is in the stall. If individual stall sensors are used, they should be installed in such a way that they do not detect movement outside the stall to avoid false triggers.
  • Sink and Mirror Area: Install a ceiling occupancy sensor above the sink and mirror area. This sensor should be positioned to cover the entire area, ensuring that lights remain on when someone is using the sink or mirror.
  • Avoidance of Air Vents: Do not mount sensors close to air vents, as the vibration and air flow can reduce the effectiveness of the sensor. PIR sensors should not be within 4ft of an air vent, and ultrasonic sensors should not be within 6ft of an air vent.
  • Manual Control: Integrate manual control to turn ON/OFF all lighting with our occupancy/vacancy sensors. This allows for manual override of the lighting system if necessary.

Wall Sensor Switches

RZ020/021 Motion Sensor Switches

  • 2-wire, 3-wire, 4-wires wiring options
  • Occupancy, Vacancy, Manual ON/OFF
  • Adjustive time delay and ambient light control

Multi-Location Wireless Wall Sensors

RZ020A/021A + RZ022W Kits

  • Hardwired RZ021A/022A occupancy sensor switch
  • Wireless companion switch (RZ022W) for multi-location control

Ceiling Occupancy Sensors

RZ036

  • Hardwired occupancy sensors
  • Auto ON, auto OFF
  • Line voltage and Low voltage available

Core features included:

  • Integrated manual ON/OFF control for all lighting
  • Vacancy sensors (Manual ON only): Lights must be turned on manually only
  • Adjustable time-delay, lighting is automatically turned full OFF after 15mins
  • Additional: multi-location wireless kits to expand the control range without re-wring
  • Additional: multiple wiring options available for both new constructions and retrofit projects.

Meets the Mandatory Provisions

IECC – 2011

C405.2.1 Occupant sensor controls

Occupant sensor controls shall be installed to control lights in the space.

C405.2.1.1 Occupant sensor control functions

  • Manual on or partial on to no more than 50% power.
  • Full off within 20 minutes after all occupants have left the space
  • A manual control to turn off the lights.

**Full automatic-on controls with no manual control are permitted in restrooms where manual operation would endanger occupant safety or security.

ASHRAE 90.1 – 2022

Restrooms shall also be controlled by occupant sensors.

9.4.1.1 H Automatic full OFF control

All lighting in the space shall be automatically shut off within 20 minutes of all occupants leaving the space

Title 24 – 2022

130.1 (a) Manual area controls.

Each area enclosed by ceiling-height partitions shall provide lighting controls that allow the lighting in that area to be manually turned on and off.

** Restrooms having two or more stalls may use a manual control not accessible to unauthorized personnel.

130.1 (c) Shut-OFF Controls.

Lighting shall be controlled with occupant sensing controls to automatically shut OFF all of the lighting in 20 minutes or less after the control zone is unoccupied that shall function either as:

  • A. Occupant sensing controls (if 130.1(b) not required to have multi-level lighting controls); or
  • B. Partial-ON occupant sensing controls, or
  • C. Vacancy sensing controls, where all lighting responds to a manual ON input only