Discover the energy-saving potential of corridors with Rayzeek’s occupancy sensor design guide. Uncover the power of automated lighting control in your commercial building’s passageways.

Lighting the Way to Energy Efficiency in Corridors

Corridors, whether in commercial buildings, educational institutions, or healthcare facilities, are high-traffic areas that often remain illuminated throughout the day, leading to significant energy consumption. These spaces typically use fluorescent or LED lighting, which, while energy-efficient, can still contribute to high energy costs when left on unnecessarily.

The challenge lies in the fact that corridors are intermittently occupied, with periods of high foot traffic interspersed with times of vacancy. Traditional manual lighting controls can lead to lights being left on during these vacant periods, resulting in unnecessary energy waste.

By integrating our occupancy sensors into your corridor lighting system, you can ensure that lights are only on when needed, saving energy and reducing costs. Our sensors, including wall and ceiling-mounted options, are designed to comply with US Energy Codes, making them an essential component in meeting energy efficiency requirements for commercial buildings.

에너지 코드 준수

국제에너지보존코드(IECC)는 건물 에너지 효율성을 위한 최소 설계 및 시공 요구사항을 규정하기 위해 ICC(International Code Council)에서 개발한 모델 코드입니다. IECC는 최신 에너지 절약 실천법과 기술을 반영하기 위해 3년마다 개정됩니다.

IECC를 주목해야 하는 이유

IECC는 미국 전역의 주 및 지방 자치 단체에서 널리 채택되고 있습니다. IECC는 건물 외피(벽, 지붕, 창호), 난방 및 냉방 시스템, 조명 시스템을 포함한 에너지 사용의 다양한 측면을 다룹니다.

IECC는 다양한 구역의 빈 공간에서 발생하는 에너지 낭비를 최소화하기 위해 점유 감지 센서와 같은 특정 조명 제어 장치의 설치를 의무화합니다.

ANSI/ASHRAE/IES Standard 90.1(저층 주거용 건물을 제외한 부지 및 건물의 에너지 표준)은 미국냉난방공조학회(ASHRAE)에서 발행하는 광범위하게 인정받는 에너지 표준입니다.

ASHRAE 90.1을 주목해야 하는 이유

ASHRAE 90.1은 미국 전역의 건물 에너지 코드의 기준 표준으로 사용되며, 건물 외피, HVAC 시스템, 급탕 시스템, 조명 시스템을 포함한 상업용 건물 구성 요소의 에너지 효율적 성능에 대한 최소 요구사항을 개괄하는 IECC 내 준수 경로 역할을 합니다.

ASHRAE 90.1 표준은 최대 허용 조명 전력 밀도 및 특정 구역에서의 점유 감지 센서 사용을 포함한 최소 조명 제어 요구사항을 규정합니다.

캘리포니아 건물 표준법 Part 6의 Title 24(공식 명칭: 주거용 및 비주거용 건물 에너지 효율성 표준)는 캘리포니아 에너지 위원회(CEC)에서 관리하며, 새로운 에너지 효율 기술과 방법을 반영하기 위해 주기적으로 업데이트됩니다.

Title 24를 주목해야 하는 이유

Title 24는 미국 내 다른 수많은 에너지 코드보다 더욱 엄격한 요구사항을 가진 것으로 잘 알려져 있습니다. Title 24는 난방, 환기, 공조(HVAC), 급탕, 조명을 포함한 건물 건설의 모든 측면에 대해 엄격한 에너지 성능 표준을 준수하도록 규정합니다.

Title 24는 에너지가 낭비되지 않도록 상업용 건물의 특정 구역에서 재실 여부에 따라 조명을 조절하는 점유 감지 센서 설치를 의무화합니다.

주별 에너지 코드 채택 현황

상세 표를 보려면 펼치기 ↓

주(State)현행 상업용 건축 기준상업용 건축 기준 에너지 효율 카테고리
앨라배마90.1-201390.1-2013
알래스카주 전체 기준 없음주 전체 건축 기준 없음
애리조나자치 도시 규정 적용(Home rule)<90.1-2007
아칸소2009 IECC 및 90.1-200790.1-2007
캘리포니아2022년 건물 에너지 효율 기준90.1-2019
콜로라도자치 도시 규정 적용(Home rule)주 전체 건축 기준 없음
코네티컷2021 IECC 및 90.1-201990.1-2019
델라웨어2018 IECC 및 90.1-201690.1-2013
컬럼비아 특별구90.1-2013^90.1-2019
플로리다2021 IECC 및 90.1-2019^90.1-2016
조지아2015 IECC 및 90.1-2013^90.1-2013
하와이자치 도시 규정 적용(Home rule)90.1-2013
아이다호2018 IECC 및 90.1-201690.1-2013
일리노이2021 IECC 및 90.1-201990.1-2019
인디애나90.1-200790.1-2007
아이오와2012 IECC 및 90.1-201090.1-2007
캔자스자치 도시 규정 적용(Home rule)주 전체 건축 기준 없음
켄터키2012 IECC 및 90.1-201090.1-2007
루이지애나2021 IECC 및 90.1-2019^90.1-2016
메인2015 IECC 및 90.1-201390.1-2013
메릴랜드2021 IECC 및 90.1-2019^90.1-2019
매사추세츠2018 IECC 및 90.1-2016^90.1-2019
미시간2015 IECC 및 90.1-2013^90.1-2013
미네소타90.1-2019^90.1-2019
미시시피주 전체 기준 없음주 전체 건축 기준 없음
미주리자치 도시 규정 적용(Home rule)주 전체 건축 기준 없음
몬태나2021 IECC 및 90.1-201990.1-2019
네브래스카2018 IECC 및 90.1-201690.1-2013
네바다2018 IECC 및 90.1-201690.1-2013
뉴햄프셔2018 IECC 및 90.1-2016^90.1-2013
뉴저지90.1-201990.1-2019
뉴멕시코2021 IECC 및 90.1-2019^90.1-2019
뉴욕2018 IECC 및 90.1-2016^90.1-2016
노스캐롤라이나2015 IECC 및 90.1-2013^90.1-2010
노스다코타자치 도시 규정 적용(Home rule)주 전체 건축 기준 없음
오하이오2021 IECC 및 90.1-2019^90.1-2016
오클라호마2006 IECC 및 90.1-2004<90.1-2007
오레곤90.1-201990.1-2019
펜실베이니아2018 IECC 및 90.1-201690.1-2013
로드아일랜드2018 IECC 및 90.1-2016^90.1-2013
사우스캐롤라이나2009 IECC 및 90.1-200790.1-2007
사우스다코타자치 도시 규정 적용(Home rule)주 전체 건축 기준 없음
테네시2021 IECC 및 90.1-201390.1-2007
텍사스2015 IECC 및 90.1-201390.1-2013
유타2021 IECC 및 90.1-2019^90.1-2019
버몬트2021 IECC 및 90.1-2019^90.1-2019
버기니아2021 IECC 및 90.1-2019^90.1-2019
워싱턴2018년 워싱턴주 에너지 코드90.1-2019
테네시2012 IECC 및 90.1-201090.1-2007
텍사스2015 IECC 및 90.1-201390.1-2013
유타2021 IECC 및 90.1-2019^90.1-2019
버몬트2018 IECC 및 90.1-2016^90.1-2019
버기니아2021 IECC 및 90.1-2019^90.1-2019
워싱턴2018년 워싱턴주 에너지 코드90.1-2019
웨스트버지니아주90.1-201390.1-2013
위스콘신주2015 IECC 및 90.1-2013^90.1-2010
와이오밍주자치 도시 규정 적용(Home rule)주 전체 건축 기준 없음
  • ^ 에너지 효율에 영향을 미치는 개정안을 DOE 프로토타입 건물 모델을 사용하여 정량화할 수 있는 경우, 해당 개정안은 분석에 반영되었습니다.
  • IECC와 90.1을 모두 채택하는 주의 경우, IECC 코드에 광범위한 개정안이 있는 주를 제외하고는 본 연구에서 일반적으로 IECC 코드를 주의 현행 코드로 분석합니다.

센서 솔루션

Rayzeek가 에너지 절감 과제를 어떻게 해결할 수 있는지 알아보세요.

모든 제품 및 서비스 보기

복도를 위한 디자인 가이드 핵심 개념

복도를 위한 에너지 효율적인 조명 제어 솔루션을 설계하려면 공간 전체를 완벽하게 감지할 수 있도록 점유 센서를 전략적으로 배치해야 합니다.

In a corridor, the primary goal is to ensure safe and well-lit passage for occupants while minimizing energy waste and all potential access points and the entire length of the corridor are covered by the sensors. Here are some design considerations:

  • Sensor Placement: For long corridors, multiple sensors may be required. Ceiling-mounted sensors can be placed at regular intervals along the length of the corridor to ensure comprehensive coverage. Alternatively, wall-mounted sensors can be placed at both ends of the corridor, with their coverage areas overlapping in the middle to avoid any blind spots. Also, consider the height and range of the sensors to ensure they can effectively detect movement across the entire corridor.
  • 센서 유형: Depending on the ceiling height and the presence of any potential obstructions, either ceiling-mounted or wall-mounted sensors can be used. Rayzeek’s ceiling sensors offer automatic ON and full OFF functionality, while our wall sensors provide manual ON and full OFF functionality.
  • Additional Manual Controls: In addition to occupancy sensors, manual controls can be integrated for instances where manual override is necessary. These controls can be conveniently located near entrances or exits.
  • Avoiding False Triggers: Sensors should be placed such that they do not directly face doors leading to other spaces, external light sources and air vents, as this could lead to false triggers when movement is detected in these adjacent spaces.

Wall Sensor Switches

RZ020/021 Motion Sensor Switches

  • 2-wire, 3-wire, 4-wires wiring options
  • Occupancy, Vacancy, Manual ON/OFF
  • Adjustive time delay and ambient light control

Multi-Location Wireless Wall Sensors

RZ020A/021A + RZ022W Kits

  • Hardwired RZ021A/022A occupancy sensor switch
  • Wireless companion switch (RZ022W) for multi-location control

Ceiling Occupancy Sensors

RZ036

  • Hardwired occupancy sensors
  • Auto ON, auto OFF
  • Line voltage and Low voltage available

Core features included:

  • Integrated manual ON/OFF control for all lighting
  • Vacancy sensors (Manual ON only): Lights must be turned on manually only
  • Adjustable time-delay, lighting is automatically turned full OFF after 15mins
  • Additional: multi-location wireless kits to expand the control range without re-wring
  • Additional: multiple wiring options available for both new constructions and retrofit projects.

Meets the Mandatory Provisions

IECC – 2011

C405.2.1 Occupant sensor controls

Occupant sensor controls shall be installed to control lights in the space.

C405.2.1.1 Occupant sensor control functions

  • Manual on or partial on to no more than 50% power.
  • Full off within 20 minutes after all occupants have left the space
  • A manual control to turn off the lights.

Full automatic-on controls with no manual control are permitted in corridors where manual operation would endanger occupant safety or security.

C405.2.1.4 Occupant sensor control function in corridors.

Occupant sensor controls in corridors shall uniformly reduce lighting power to an occupied setpoint not more than 50 percent offull power within 20 minutes after all occupants have left the space.

Exception: Corridors provided with less than two footcandles of illumination on the floor at the darkest point with all lights on.

ASHRAE 90.1 – 2022

9.4.1.1 a Local control

There shall be one or more manual lighting control device that provides ON and OFF control
of all lighting in the space.

9.4.1.1 g Automatic reduction control

The general lighting power in the space shall be automatically reduced by at least 50% within 15 minutes of all occupants leaving the space.

9.4.1.1 h Automatic full OFF control

All lighting in the space shall be automatically shut off within 15 minutes of all occupants leaving the space.

9.4.1.1 i Scheduled shutoff

All lighting in the space shall be automatically shut off during periods when the space is scheduled to be unoccupied.

** NOTE: At least one 9.4.1.1 h or 9.4.1.1 i shall be implemented.

Title 24 – 2022

130.1 (a) Manual area controls.

Each area enclosed by ceiling-height partitions shall provide lighting controls that allow the lighting in that area to be manually turned on and off.

130.1 (c) Shut-OFF Controls.

In corridors, lighting shall be controlled by Full or partial-OFF occupant sensing controls that separately reduce the lighting power in each space by at least 50 percent when the space is unoccupied. The occupant sensing controls shall be capable of automatically turning the lighting fully ON only in the separately controlled space, and shall be automatically activated from all designed paths of egress.

Let us hear you.

Let Rayzeek help design and deliver a bespoke energy-saving lighting solution for you.