Discover the energy-saving potential of corridors with Rayzeek’s occupancy sensor design guide. Uncover the power of automated lighting control in your commercial building’s passageways.

Lighting the Way to Energy Efficiency in Corridors
Corridors, whether in commercial buildings, educational institutions, or healthcare facilities, are high-traffic areas that often remain illuminated throughout the day, leading to significant energy consumption. These spaces typically use fluorescent or LED lighting, which, while energy-efficient, can still contribute to high energy costs when left on unnecessarily.
The challenge lies in the fact that corridors are intermittently occupied, with periods of high foot traffic interspersed with times of vacancy. Traditional manual lighting controls can lead to lights being left on during these vacant periods, resulting in unnecessary energy waste.
By integrating our occupancy sensors into your corridor lighting system, you can ensure that lights are only on when needed, saving energy and reducing costs. Our sensors, including wall and ceiling-mounted options, are designed to comply with US Energy Codes, making them an essential component in meeting energy efficiency requirements for commercial buildings.
עמידה בתקני האנרגיה

התקן הבינלאומי לשימור אנרגיה (IECC) הוא תקן מודל שפותח על ידי מועצת התקנים הבינלאומית (ICC) כדי לקבוע דרישות תכנון ובנייה מינימליות ליעילות אנרגטית במבנים. ה-IECC מתעדכן מדי שלוש שנים כדי לשלב את שיטות העבודה והטכנולוגיות העדכניות ביותר בתחום שימור האנרגיה.
IECC, מדוע זה צריך לעניין אותך
תקן IECC מאומץ במידה רבה על ידי מדינות ורשויות מקומיות ברחבי ארצות הברית. IECC מכסה היבטים שונים של שימוש באנרגיה, לרבות מעטפת הבניין (קירות, גגות וחלונות), מערכות חימום וקירור, ומערכות תאורה.
תקן IECC מחייב בקרות תאורה ספציפיות, כגון חיישני תפוסה, כדי למזער בזבוז אנרגיה בחללים לא מאוכלסים באזורים שונים.

תקן ANSI/ASHRAE/IES 90.1, תקן אנרגיה לאתרים ולמבנים למעט מבני מגורים נמוכים, הוא תקן אנרגיה מוכר גלובלית המפורסם על ידי האגודה האמריקאית למהנדסי חימום, קירור ומזוג אוויר (ASHRAE).
ASHRAE 90.1, מדוע זה צריך לעניין אותך
תקן ASHRAE 90.1 משמש כנקודת התייחסות (מדד) לתקני אנרגיה בבנייה ברחבי ארצות הברית ומשמש כמסלול ציות במסגרת ה-IECC, המתווה דרישות מינימום לביצועים יעילים באנרגיה של רכיבי מבנים מסחריים, כולל מעטפת הבניין, מערכות מיזוג אוויר (HVAC), מערכות חימום מים ומערכות תאורה.
תקן ASHRAE 90.1 מגדיר צפיפות הספק תאורה מרבית מותרת ודרישות מינימום לבקרת תאורה, כולל שימוש בחיישני תפוסה באזורים ספציפיים.

Title 24, חלק 6 של קוד תקני הבנייה של קליפורניה, הידוע רשמית כתקני יעילות אנרגטית בבנייה למבני מגורים ושאינם למגורים, מנוהל על ידי נציבות האנרגיה של קליפורניה (CEC) ומתעדכן תקופתית כדי לשקף טכנולוגיות ושיטות חדשות ליעילות אנרגטית.
Title 24, מדוע זה צריך לעניין אותך
תקן Title 24 ידוע בדרישות המחמירות שלו, הנחשבות לרוב למחמירות יותר מאלו שנמצאות בתקני אנרגיה רבים אחרים ברחבי ארצות הברית. Title 24 מחייב תקני ביצועים אנרגטיים קפדניים לכל היבטי הבנייה, הכוללים חימום, אוורור, מיזוג אוויר (HVAC), חימום מים ותאורה.
תקן Title 24 מחייב התקנת חיישני תפוסה המתאימים את התאורה בהתבסס על תפוסת החדר באזורים ספציפיים של מבנים מסחריים כדי להבטיח שאנרגיה לא תתבזבז.
אימוץ תקני אנרגיה לפי מדינה

התרחבו כדי לצפות בטבלה המפורטת ↓
| מדינה | תקן מסחרי נוכחי | קטגוריית יעילות תקן מסחרי |
|---|---|---|
| אלבמה | 90.1-2013 | 90.1-2013 |
| אלסקה | אין תקן כלל-מדינתי | אין תקן כלל-מדינתי |
| אריזונה | שלטון מקומי (Home rule) | <90.1-2007 |
| ארקנסו | 2009 IECC ו-90.1-2007 | 90.1-2007 |
| קליפורניה | תקני יעילות אנרגטית לבנייה 2022 | 90.1-2019 |
| קולורדו | שלטון מקומי (Home rule) | אין תקן כלל-מדינתי |
| קונטיקט | 2021 IECC ו-90.1-2019 | 90.1-2019 |
| דלאוור | 2018 IECC ו-90.1-2016 | 90.1-2013 |
| מחוז קולומביה | 90.1-2013^ | 90.1-2019 |
| פלורידה | 2021 IECC ו-90.1-2019^ | 90.1-2016 |
| ג'ורג'יה | 2015 IECC ו-90.1-2013^ | 90.1-2013 |
| הוואי | שלטון מקומי (Home rule) | 90.1-2013 |
| איידהו | 2018 IECC ו-90.1-2016 | 90.1-2013 |
| אילינוי | 2021 IECC ו-90.1-2019 | 90.1-2019 |
| אינדיאנה | 90.1-2007 | 90.1-2007 |
| איווה | 2012 IECC ו-90.1-2010 | 90.1-2007 |
| קנזס | שלטון מקומי (Home rule) | אין תקן כלל-מדינתי |
| קנטקי | 2012 IECC ו-90.1-2010 | 90.1-2007 |
| לואיזיאנה | 2021 IECC ו-90.1-2019^ | 90.1-2016 |
| מיין | 2015 IECC ו-90.1-2013 | 90.1-2013 |
| מרילנד | 2021 IECC ו-90.1-2019^ | 90.1-2019 |
| מסצ'וסטס | 2018 IECC ו-90.1-2016^ | 90.1-2019 |
| מישיגן | 2015 IECC ו-90.1-2013^ | 90.1-2013 |
| מינסוטה | 90.1-2019^ | 90.1-2019 |
| מיסיסיפי | אין תקן כלל-מדינתי | אין תקן כלל-מדינתי |
| מיזורי | שלטון מקומי (Home rule) | אין תקן כלל-מדינתי |
| מונטנה | 2021 IECC ו-90.1-2019 | 90.1-2019 |
| נברסקה | 2018 IECC ו-90.1-2016 | 90.1-2013 |
| נבאדה | 2018 IECC ו-90.1-2016 | 90.1-2013 |
| ניו המפשייר | 2018 IECC ו-90.1-2016^ | 90.1-2013 |
| ניו ג'רזי | 90.1-2019 | 90.1-2019 |
| ניו מקסיקו | 2021 IECC ו-90.1-2019^ | 90.1-2019 |
| ניו יורק | 2018 IECC ו-90.1-2016^ | 90.1-2016 |
| צפון קרוליינה | 2015 IECC ו-90.1-2013^ | 90.1-2010 |
| צפון דקוטה | שלטון מקומי (Home rule) | אין תקן כלל-מדינתי |
| אוהיו | 2021 IECC ו-90.1-2019^ | 90.1-2016 |
| אוקלהומה | 2006 IECC and 90.1-2004 | <90.1-2007 |
| Oregon | 90.1-2019 | 90.1-2019 |
| Pennsylvania | 2018 IECC ו-90.1-2016 | 90.1-2013 |
| Rhode Island | 2018 IECC ו-90.1-2016^ | 90.1-2013 |
| South Carolina | 2009 IECC ו-90.1-2007 | 90.1-2007 |
| South Dakota | שלטון מקומי (Home rule) | אין תקן כלל-מדינתי |
| Tennessee | 2021 IECC and 90.1-2013 | 90.1-2007 |
| Texas | 2015 IECC ו-90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC ו-90.1-2019^ | 90.1-2019 |
| Vermont | 2021 IECC ו-90.1-2019^ | 90.1-2019 |
| Virginia | 2021 IECC ו-90.1-2019^ | 90.1-2019 |
| Washington | 2018 Washington State Energy Code | 90.1-2019 |
| Tennessee | 2012 IECC ו-90.1-2010 | 90.1-2007 |
| Texas | 2015 IECC ו-90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC ו-90.1-2019^ | 90.1-2019 |
| Vermont | 2018 IECC ו-90.1-2016^ | 90.1-2019 |
| Virginia | 2021 IECC ו-90.1-2019^ | 90.1-2019 |
| Washington | 2018 Washington State Energy Code | 90.1-2019 |
| West Virginia | 90.1-2013 | 90.1-2013 |
| Wisconsin | 2015 IECC ו-90.1-2013^ | 90.1-2010 |
| Wyoming | שלטון מקומי (Home rule) | אין תקן כלל-מדינתי |
- ^ When an amendment impacting energy efficiency can be quantified using DOE Prototype Building Models, they were captured in the analysis.
- For states adopting both IECC and 90.1, the IECC code is usually analyzed as the state current code in this study except for states with extensive amendments to the IECC.
Design Guide Key Concepts for Corridors
Designing an energy-efficient lighting control solution for corridors involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.

In a corridor, the primary goal is to ensure safe and well-lit passage for occupants while minimizing energy waste and all potential access points and the entire length of the corridor are covered by the sensors. Here are some design considerations:
- Sensor Placement: For long corridors, multiple sensors may be required. Ceiling-mounted sensors can be placed at regular intervals along the length of the corridor to ensure comprehensive coverage. Alternatively, wall-mounted sensors can be placed at both ends of the corridor, with their coverage areas overlapping in the middle to avoid any blind spots. Also, consider the height and range of the sensors to ensure they can effectively detect movement across the entire corridor.
- סוג חיישן: Depending on the ceiling height and the presence of any potential obstructions, either ceiling-mounted or wall-mounted sensors can be used. Rayzeek’s ceiling sensors offer automatic ON and full OFF functionality, while our wall sensors provide manual ON and full OFF functionality.
- Additional Manual Controls: In addition to occupancy sensors, manual controls can be integrated for instances where manual override is necessary. These controls can be conveniently located near entrances or exits.
- Avoiding False Triggers: Sensors should be placed such that they do not directly face doors leading to other spaces, external light sources and air vents, as this could lead to false triggers when movement is detected in these adjacent spaces.
Featured Products & Solutions
Core features included:
- Integrated manual ON/OFF control for all lighting
- Vacancy sensors (Manual ON only): Lights must be turned on manually only
- Adjustable time-delay, lighting is automatically turned full OFF after 15mins
- Additional: multi-location wireless kits to expand the control range without re-wring
- Additional: multiple wiring options available for both new constructions and retrofit projects.

Meets the Mandatory Provisions
IECC – 2011
C405.2.1 Occupant sensor controls
Occupant sensor controls shall be installed to control lights in the space.
C405.2.1.1 Occupant sensor control functions
- Manual on or partial on to no more than 50% power.
- Full off within 20 minutes after all occupants have left the space
- A manual control to turn off the lights.
Full automatic-on controls with no manual control are permitted in corridors where manual operation would endanger occupant safety or security.
C405.2.1.4 Occupant sensor control function in corridors.
Occupant sensor controls in corridors shall uniformly reduce lighting power to an occupied setpoint not more than 50 percent offull power within 20 minutes after all occupants have left the space.
Exception: Corridors provided with less than two footcandles of illumination on the floor at the darkest point with all lights on.
ASHRAE 90.1 – 2022
9.4.1.1 a Local control
There shall be one or more manual lighting control device that provides ON and OFF control
of all lighting in the space.
9.4.1.1 g Automatic reduction control
The general lighting power in the space shall be automatically reduced by at least 50% within 15 minutes of all occupants leaving the space.
9.4.1.1 h Automatic full OFF control
All lighting in the space shall be automatically shut off within 15 minutes of all occupants leaving the space.
9.4.1.1 i Scheduled shutoff
All lighting in the space shall be automatically shut off during periods when the space is scheduled to be unoccupied.
** NOTE: At least one 9.4.1.1 h or 9.4.1.1 i shall be implemented.
Title 24 – 2022
130.1 (a) Manual area controls.
Each area enclosed by ceiling-height partitions shall provide lighting controls that allow the lighting in that area to be manually turned on and off.
130.1 (c) Shut-OFF Controls.
In corridors, lighting shall be controlled by Full or partial-OFF occupant sensing controls that separately reduce the lighting power in each space by at least 50 percent when the space is unoccupied. The occupant sensing controls shall be capable of automatically turning the lighting fully ON only in the separately controlled space, and shall be automatically activated from all designed paths of egress.
Let us hear you.
Let Rayzeek help design and deliver a bespoke energy-saving lighting solution for you.