Open Offices

Раскройте потенциал автоматизированного управления освещением для повышения эффективности и снижения потерь электроэнергии. Узнайте, как оптимизировать управление освещением для обеспечения эффективности и комфорта на вашем рабочем месте.

Revolutionize Your Open Office Lighting with Smart Occupancy Sensors

Open offices, characterized by their large areas and cubicle partitions, are a common sight in many modern workplaces. These spaces are typically bustling with activity, filled with employees working, collaborating, and moving around. The expansive area requires ample illumination, often provided by high-intensity light fixtures. These lights, left on throughout the workday, consume a substantial amount of energy. Moreover, even when the office is vacant, during off-hours or lunch breaks, the lights often remain on, leading to unnecessary energy consumption.

The high energy consumption of lighting in open offices is a concern for both environmental and economic reasons. With the increasing emphasis on energy efficiency and sustainability, businesses are seeking ways to reduce their energy footprint. Moreover, energy costs can account for a significant portion of a company’s operating expenses, making energy-saving measures a smart financial decision as well.

To address this, the integration of occupancy sensors in open offices presents a compelling solution. Occupancy sensors can automatically control lighting based on the presence of individuals in the space, significantly reducing unnecessary energy consumption. When the office is vacant, the sensors can automatically switch off or dim the lights, thereby conserving energy. With our sensors seamlessly integrated into your open office layout, you can transform your open office into an energy-efficient workspace that meets the stringent requirements of US Energy Codes.

Соответствие энергетическим стандартам

Международный код по энергосбережению (IECC) представляет собой типовой свод правил, разработанный Международным советом по строительным нормам и правилам (ICC) для установления минимальных требований к проектированию и строительству с точки зрения энергоэффективности зданий. IECC обновляется каждые три года, чтобы включать новейшие практики и технологии в области энергосбережения.

Почему IECC важен для вас

IECC широко применяется штатами и муниципалитетами по всей территории США. IECC охватывает различные аспекты энергопотребления, включая ограждающие конструкции здания (стены, крыши и окна), системы отопления и охлаждения, а также системы освещения.

IECC предписывает обязательное использование специальных средств управления освещением, таких как датчики присутствия, чтобы минимизировать потерю энергии в незанятых помещениях различных зон.

Стандарт ANSI/ASHRAE/IES 90.1 «Стандарт энергоэффективности зданий и сооружений, за исключением малоэтажных жилых зданий» — это широко признанный стандарт энергоэффективности, публикуемый Американским обществом инженеров по отоплению, охлаждению и кондиционированию воздуха (ASHRAE).

Почему ASHRAE 90.1 важен для вас

ASHRAE 90.1 используется в качестве ориентира для энергетических строительных норм по всей территории США и служит вариантом подтверждения соответствия в рамках IECC, определяя минимальные требования к энергоэффективности компонентов коммерческих зданий, включая ограждающие конструкции, системы HVAC, системы горячего водоснабжения и системы освещения.

Стандарт ASHRAE 90.1 устанавливает максимально допустимую удельную мощность освещения и минимальные требования к управлению освещением, включая использование датчиков присутствия в определенных зонах.

Раздел 24, часть 6 Строительных стандартов штата Калифорния, официально известный как «Стандарты энергоэффективности жилых и нежилых зданий» (Title 24), находится в ведении Энергетической комиссии штата Калифорния и периодически обновляется с учетом новых технологий и методов энергоэффективности.

Почему Title 24 важен для вас

Стандарт Title 24 известен своими строгими требованиями, которые часто считаются более жесткими, чем нормы других энергетических сводов правил в США. Title 24 устанавливает строгие стандарты энергоэффективности для всех аспектов строительства зданий, включая отопление, вентиляцию, кондиционирование воздуха (HVAC), горячее водоснабжение и освещение.

Title 24 требует установки датчиков присутствия, регулирующих освещение в зависимости от наличия людей в определенных помещениях коммерческих зданий, что предотвращает нерациональный расход энергии.

Применение энергетических стандартов по штатам

Разверните, чтобы просмотреть подробную таблицу ↓

ШтатДействующий коммерческий строительный кодКатегория эффективности коммерческого строительного кода
Алабама90.1-201390.1-2013
АляскаОтсутствует на уровне штатаНет единого строительного кода на уровне штата
АризонаМестное самоуправление<90.1-2007
Арканзас2009 IECC и 90.1-200790.1-2007
Калифорния2022 Стандарты энергоэффективности зданий90.1-2019
КолорадоМестное самоуправлениеНет единого строительного кода на уровне штата
Коннектикут2021 IECC и 90.1-201990.1-2019
Делавэр2018 IECC и 90.1-201690.1-2013
Округ Колумбия90.1-2013^90.1-2019
Флорида2021 IECC и 90.1-2019^90.1-2016
Джорджия2015 IECC и 90.1-2013^90.1-2013
ГавайиМестное самоуправление90.1-2013
Айдахо2018 IECC и 90.1-201690.1-2013
Иллинойс2021 IECC и 90.1-201990.1-2019
Индиана90.1-200790.1-2007
Айова2012 IECC и 90.1-201090.1-2007
КанзасМестное самоуправлениеНет единого строительного кода на уровне штата
Кентукки2012 IECC и 90.1-201090.1-2007
Луизиана2021 IECC и 90.1-2019^90.1-2016
Мэн2015 IECC и 90.1-201390.1-2013
Мэриленд2021 IECC и 90.1-2019^90.1-2019
Массачусетс2018 IECC и 90.1-2016^90.1-2019
Мичиган2015 IECC и 90.1-2013^90.1-2013
Миннесота90.1-2019^90.1-2019
МиссисипиОтсутствует на уровне штатаНет единого строительного кода на уровне штата
МиссуриМестное самоуправлениеНет единого строительного кода на уровне штата
Монтана2021 IECC и 90.1-201990.1-2019
Небраска2018 IECC и 90.1-201690.1-2013
Невада2018 IECC и 90.1-201690.1-2013
Нью-Гэмпшир2018 IECC и 90.1-2016^90.1-2013
Нью-Джерси90.1-201990.1-2019
Нью-Мексико2021 IECC и 90.1-2019^90.1-2019
Нью-Йорк2018 IECC и 90.1-2016^90.1-2016
Северная Каролина2015 IECC и 90.1-2013^90.1-2010
Северная ДакотаМестное самоуправлениеНет единого строительного кода на уровне штата
Огайо2021 IECC и 90.1-2019^90.1-2016
Оклахома2006 IECC и 90.1-2004<90.1-2007
Орегон90.1-201990.1-2019
Пенсильвания2018 IECC и 90.1-201690.1-2013
Род-Айленд2018 IECC и 90.1-2016^90.1-2013
Южная Каролина2009 IECC и 90.1-200790.1-2007
Южная ДакотаМестное самоуправлениеНет единого строительного кода на уровне штата
Теннесси2021 IECC и 90.1-201390.1-2007
Техас2015 IECC и 90.1-201390.1-2013
Юта2021 IECC и 90.1-2019^90.1-2019
Вермонт2021 IECC и 90.1-2019^90.1-2019
Виргиния2021 IECC и 90.1-2019^90.1-2019
ВашингтонЭнергетический кодекс штата Вашингтон 2018 года90.1-2019
Теннесси2012 IECC и 90.1-201090.1-2007
Техас2015 IECC и 90.1-201390.1-2013
Юта2021 IECC и 90.1-2019^90.1-2019
Вермонт2018 IECC и 90.1-2016^90.1-2019
Виргиния2021 IECC и 90.1-2019^90.1-2019
ВашингтонЭнергетический кодекс штата Вашингтон 2018 года90.1-2019
Западная Виргиния90.1-201390.1-2013
Висконсин2015 IECC и 90.1-2013^90.1-2010
ВайомингМестное самоуправлениеНет единого строительного кода на уровне штата
  • ^ Если поправка, влияющая на энергоэффективность, могла быть количественно оценена с использованием типовых моделей зданий Министерства энергетики США (DOE), она учитывалась в анализе.
  • Для штатов, принимающих как IECC, так и 90.1, кодекс IECC обычно анализируется в данном исследовании как действующий кодекс штата, за исключением штатов с обширными поправками к IECC.

Решения на базе датчиков

Узнайте, как Rayzeek может помочь в решении ваших задач по энергосбережению.

Просмотреть все предложения

Ключевые концепции руководства по проектированию освещения для офисов открытого типа

Проектирование энергоэффективного решения по управлению освещением для офисов открытого типа требует стратегического размещения датчиков присутствия для обеспечения полного охвата пространства.

In an open office setting, the primary areas to consider for sensor placement are the main walkways and areas with high foot traffic. These areas are crucial for sensor placement as they are the main areas of human traffic:

  • Cover Main Walkways: The main walkways in an open office are the areas with the highest foot traffic. Therefore, these should be the primary focus when placing sensors. Ceiling-mounted sensors are ideal for these areas as they provide a wide coverage area and are strategically placed to cover the entire length.
  • Overlap Coverage on Walkways: To avoid blind spots, ensure that the coverage patterns of the sensors overlap along the walkways. This ensures continuous detection as people move through the space, preventing any gaps in sensor coverage.
  • Use a Long Timeout: Given the size and activity level in open offices, use a longer timeout setting (15 or 20 minutes) on the sensors. This prevents the lights from turning off too soon when there’s no movement detected for a brief period.
  • Consider Wall-Mounted Sensors: If the cubicle walls are short, consider using wall-mounted sensors in addition to ceiling-mounted ones. These can provide additional coverage and ensure that all areas of the office are monitored.
  • Avoid Air Vents: Don’t place sensors near air vents. The vibration and airflow can reduce the effectiveness of the sensors. PIR sensors should not be within 4ft of an air vent, and ultrasonic sensors should not be within 6ft of an air vent.
  • Manual Control: Incorporate manual controls that are integrated with the occupancy sensors. This allows for manual override to turn ON/OFF all lighting when necessary.

Настенные датчики-выключатели

Датчики-выключатели движения RZ020/021

  • Варианты подключения: 2-проводное, 3-проводное, 4-проводное
  • Режимы: Присутствие (Occupancy), Отсутствие (Vacancy), Ручное ВКЛ/ВЫКЛ
  • Регулируемая задержка времени и контроль уровня освещенности

Беспроводные настенные датчики для управления из нескольких точек

Комплекты RZ020A/021A + RZ022W

  • Проводной датчик-выключатель присутствия RZ021A/022A
  • Беспроводной дополнительный выключатель (RZ022W) для управления из нескольких мест

Потолочные датчики присутствия

RZ036

  • Проводные датчики присутствия
  • Автоматическое включение, автоматическое выключение
  • Доступно исполнение с сетевым и низким напряжением

Основные функции:

  • Встроенное ручное управление включением/выключением для всего освещения
  • Датчики отсутствия (только ручное включение): свет необходимо включать только вручную
  • Регулируемая задержка времени, освещение автоматически полностью выключается через 15 минут
  • Дополнительно: многоточечные беспроводные комплекты для расширения зоны управления без прокладки новой проводки
  • Дополнительно: несколько вариантов подключения как для нового строительства, так и для проектов модернизации.

Соответствует обязательным требованиям

IECC – 2011

C405.2.1 Элементы управления датчиков присутствия

Для управления освещением в помещении должны быть установлены элементы управления датчиков присутствия.

For open offices < 300 sq. ft:

C405.2.1.1 Функции элементов управления датчиков присутствия

  • Ручное включение или частичное включение не более чем на 50% мощности.
  • Полное выключение в течение 20 минут после того, как все люди покинут помещение
  • Ручной орган управления для выключения света.

For open offices > 300 sq. ft:

  • The general lighting shall be controlled separately in control zones with floor areas not greater than 600 sq. ft within the open plan office space.
  • In each control zone, the general lighting shall be permitted to automatically turn on within the control zone. In other unoccupied zones, the general lighting shall be permitted to turn on to < 20% full power(or unaffected).
  • Automatically turn off general lighting in all control zones within 20 minutes after all occupants have left the space.
  • In each control zone, the general lighting shall turn off or uniformly reduce lighting power to an unoccupied setpoint of < 20% full power within 20 minutes after all occupants have left.

ASHRAE 90.1 – 2022

For open offices in any sizes:

9.4.1.1 a Локальное управление

Должно быть предусмотрено одно или несколько устройств ручного управления освещением, обеспечивающих включение (ON) и выключение (OFF)
всего освещения в помещении.

9.4.1.1 b Ограничение только ручным включением (ON)

Никакая часть освещения не должна включаться автоматически

9.4.1.1 c Ограничение частичным автоматическим включением (ON)

Автоматическое включение допускается не более чем для 50% мощности общего освещения

** NOTE: At least one 9.4.1.1 b or 9.4.1.1 c shall be implemented.

9.4.1.1 H Automatic full OFF control

All lighting in the space shall be automatically shut off within 20 minutes of all occupants leaving the space

Additionally, for open offices > 300 sq. ft:

9.4.1.1 g Automatic reduction control

The general lighting power in the space shall be automatically reduced by at least 50% within 15 minutes of all occupants leaving the space.

Title 24 – 2022

For open offices in any sizes:

130.1 (a) Manual area controls.

Each area enclosed by ceiling-height partitions shall provide lighting controls that allow the lighting in that area to be manually turned on and off.

130.1 (c) Shut-OFF Controls.

Additionally, for open offices <250 sq. ft:

130.1 (c) 5. Occupant sensing controls are required for specified offices.

Lighting shall be controlled with occupant sensing controls to automatically shut OFF all of the lighting in 20 minutes or less after the control zone is unoccupied that shall function either as:

  • A. Occupant sensing controls (if 130.1(b) not required to have multi-level lighting controls); or
  • B. Partial-ON occupant sensing controls, or
  • C. Vacancy sensing controls, where all lighting responds to a manual ON input only

Additionally, for open offices > 250 sq. ft:

130.1 (c) 6. Full or partial-OFF occupant sensing controls are required for offices greater than 250 square feet.

In office spaces greater than 250 square feet, general lighting shall be controlled with occupant sensing controls that meet all of the following:

  • Lighting shall be controlled separately in control zones not greater than 600 square feet. For luminaires with an embedded occupant sensor that are capable of reducing power independently from other luminaires, each luminaire can be considered its own control zone
  • The occupant sensing controls shall uniformly reduce lighting power in the control zone by at least 80% full power(or off) in 20 minutes or less after the control zone is unoccupied.
  • The occupant sensing controls shall automatically turn off lighting in ALL control zones in 20 minutes or less after the entire office space is unoccupied
  • When occupancy is detected:
    • in each control zone, lighting shall be allowed to automatically turn on to any level up to full power.
    • in other control zones that are unoccupied, lighting shall operate at no more than 20% full power.

Let us hear you.

Let Rayzeek help design and deliver a bespoke energy-saving lighting solution for you.

    Russian