Open Offices
Ungkap keunggulan kontrol pencahayaan otomatis dalam meningkatkan efisiensi dan mengurangi pemborosan energi. Pelajari cara mengoptimalkan kontrol pencahayaan demi efisiensi dan kenyamanan di ruang kerja Anda.

Revolutionize Your Open Office Lighting with Smart Occupancy Sensors
Open offices, characterized by their large areas and cubicle partitions, are a common sight in many modern workplaces. These spaces are typically bustling with activity, filled with employees working, collaborating, and moving around. The expansive area requires ample illumination, often provided by high-intensity light fixtures. These lights, left on throughout the workday, consume a substantial amount of energy. Moreover, even when the office is vacant, during off-hours or lunch breaks, the lights often remain on, leading to unnecessary energy consumption.
The high energy consumption of lighting in open offices is a concern for both environmental and economic reasons. With the increasing emphasis on energy efficiency and sustainability, businesses are seeking ways to reduce their energy footprint. Moreover, energy costs can account for a significant portion of a company’s operating expenses, making energy-saving measures a smart financial decision as well.
To address this, the integration of occupancy sensors in open offices presents a compelling solution. Occupancy sensors can automatically control lighting based on the presence of individuals in the space, significantly reducing unnecessary energy consumption. When the office is vacant, the sensors can automatically switch off or dim the lights, thereby conserving energy. With our sensors seamlessly integrated into your open office layout, you can transform your open office into an energy-efficient workspace that meets the stringent requirements of US Energy Codes.
Memenuhi Kode Energi

International Energy Conservation Code (IECC) adalah model kode yang dikembangkan oleh International Code Council (ICC) untuk menetapkan persyaratan desain dan konstruksi minimum untuk efisiensi energi pada bangunan. IECC diperbarui setiap tiga tahun untuk menggabungkan praktik dan teknologi konservasi energi terbaru.
IECC, Mengapa Anda Harus Peduli
IECC diadopsi secara luas oleh negara bagian dan kotamadya di seluruh Amerika Serikat. IECC mencakup berbagai aspek penggunaan energi, termasuk selubung bangunan (dinding, atap, dan jendela), sistem pemanas dan pendingin, serta sistem pencahayaan.
IECC mewajibkan kontrol pencahayaan khusus, seperti sensor hunian, untuk meminimalkan pemborosan energi di area yang tidak terisi di berbagai lokasi.

Standar ANSI/ASHRAE/IES 90.1, Standar Energi untuk Tapak dan Bangunan Kecuali Bangunan Hunian Rendah, adalah standar energi yang diakui secara luas yang diterbitkan oleh American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).
ASHRAE 90.1, Mengapa Anda Harus Peduli
ASHRAE 90.1 digunakan sebagai tolok ukur untuk kode energi bangunan di seluruh Amerika Serikat dan berfungsi sebagai jalur kepatuhan dalam IECC yang menguraikan persyaratan minimum untuk kinerja efisiensi energi komponen bangunan komersial termasuk selubung bangunan, sistem HVAC, sistem pemanas air, dan sistem pencahayaan.
Standar ASHRAE 90.1 menentukan kepadatan daya pencahayaan maksimum yang diizinkan dan persyaratan kontrol pencahayaan minimum, termasuk penggunaan sensor hunian di area tertentu.

Title 24, bagian 6 dari Kode Standar Bangunan California, yang secara resmi dikenal sebagai Standar Efisiensi Energi Bangunan untuk Bangunan Hunian dan Non-hunian, Title 24 dikelola oleh California Energy Commission dan diperbarui secara berkala untuk mencerminkan teknologi dan metode efisiensi energi baru.
Title 24, Mengapa Anda Harus Peduli
Title 24 dikenal dengan persyaratannya yang ketat, yang sering kali dianggap lebih ketat daripada yang ditemukan di banyak kode energi lainnya di seluruh Amerika Serikat. Title 24 mewajibkan standar kinerja energi yang ketat untuk semua aspek konstruksi bangunan, yang mencakup pemanas, ventilasi, pengondisian udara (HVAC), pemanas air, dan pencahayaan.
Title 24 mewajibkan pemasangan sensor hunian yang menyesuaikan pencahayaan berdasarkan tingkat hunian ruangan di area tertentu di bangunan komersial untuk memastikan bahwa energi tidak terbuang sia-sia.
Penerapan Kode Energi Berdasarkan Negara Bagian

Perluas untuk melihat tabel terperinci ↓
| Negara Bagian | Kode Komersial Saat Ini | Kategori Efisiensi Kode Komersial |
|---|---|---|
| Alabama | 90.1-2013 | 90.1-2013 |
| Alaska | Tidak ada di seluruh negara bagian | Tidak ada kode seluruh negara bagian |
| Arizona | Pemerintahan mandiri (Home rule) | <90.1-2007 |
| Arkansas | 2009 IECC dan 90.1-2007 | 90.1-2007 |
| California | Standar Efisiensi Energi Bangunan 2022 | 90.1-2019 |
| Colorado | Pemerintahan mandiri (Home rule) | Tidak ada kode seluruh negara bagian |
| Connecticut | IECC 2021 dan 90.1-2019 | 90.1-2019 |
| Delaware | IECC 2018 dan 90.1-2016 | 90.1-2013 |
| District of Columbia | 90.1-2013^ | 90.1-2019 |
| Florida | IECC 2021 dan 90.1-2019^ | 90.1-2016 |
| Georgia | IECC 2015 dan 90.1-2013^ | 90.1-2013 |
| Hawaii | Pemerintahan mandiri (Home rule) | 90.1-2013 |
| Idaho | IECC 2018 dan 90.1-2016 | 90.1-2013 |
| Illinois | IECC 2021 dan 90.1-2019 | 90.1-2019 |
| Indiana | 90.1-2007 | 90.1-2007 |
| Iowa | IECC 2012 dan 90.1-2010 | 90.1-2007 |
| Kansas | Pemerintahan mandiri (Home rule) | Tidak ada kode seluruh negara bagian |
| Kentucky | IECC 2012 dan 90.1-2010 | 90.1-2007 |
| Louisiana | IECC 2021 dan 90.1-2019^ | 90.1-2016 |
| Maine | 2015 IECC dan 90.1-2013 | 90.1-2013 |
| Maryland | IECC 2021 dan 90.1-2019^ | 90.1-2019 |
| Massachusetts | 2018 IECC dan 90.1-2016^ | 90.1-2019 |
| Michigan | IECC 2015 dan 90.1-2013^ | 90.1-2013 |
| Minnesota | 90.1-2019^ | 90.1-2019 |
| Mississippi | Tidak ada di seluruh negara bagian | Tidak ada kode seluruh negara bagian |
| Missouri | Pemerintahan mandiri (Home rule) | Tidak ada kode seluruh negara bagian |
| Montana | IECC 2021 dan 90.1-2019 | 90.1-2019 |
| Nebraska | IECC 2018 dan 90.1-2016 | 90.1-2013 |
| Nevada | IECC 2018 dan 90.1-2016 | 90.1-2013 |
| New Hampshire | 2018 IECC dan 90.1-2016^ | 90.1-2013 |
| New Jersey | 90.1-2019 | 90.1-2019 |
| Meksiko Baru | IECC 2021 dan 90.1-2019^ | 90.1-2019 |
| New York | 2018 IECC dan 90.1-2016^ | 90.1-2016 |
| Karolina Utara | IECC 2015 dan 90.1-2013^ | 90.1-2010 |
| Dakota Utara | Pemerintahan mandiri (Home rule) | Tidak ada kode seluruh negara bagian |
| Ohio | IECC 2021 dan 90.1-2019^ | 90.1-2016 |
| Oklahoma | 2006 IECC dan 90.1-2004 | <90.1-2007 |
| Oregon | 90.1-2019 | 90.1-2019 |
| Pensilvania | IECC 2018 dan 90.1-2016 | 90.1-2013 |
| Rhode Island | 2018 IECC dan 90.1-2016^ | 90.1-2013 |
| Karolina Selatan | 2009 IECC dan 90.1-2007 | 90.1-2007 |
| Dakota Selatan | Pemerintahan mandiri (Home rule) | Tidak ada kode seluruh negara bagian |
| Tennessee | 2021 IECC dan 90.1-2013 | 90.1-2007 |
| Texas | 2015 IECC dan 90.1-2013 | 90.1-2013 |
| Utah | IECC 2021 dan 90.1-2019^ | 90.1-2019 |
| Vermont | IECC 2021 dan 90.1-2019^ | 90.1-2019 |
| Virginia | IECC 2021 dan 90.1-2019^ | 90.1-2019 |
| Washington | Kode Energi Negara Bagian Washington 2018 | 90.1-2019 |
| Tennessee | IECC 2012 dan 90.1-2010 | 90.1-2007 |
| Texas | 2015 IECC dan 90.1-2013 | 90.1-2013 |
| Utah | IECC 2021 dan 90.1-2019^ | 90.1-2019 |
| Vermont | 2018 IECC dan 90.1-2016^ | 90.1-2019 |
| Virginia | IECC 2021 dan 90.1-2019^ | 90.1-2019 |
| Washington | Kode Energi Negara Bagian Washington 2018 | 90.1-2019 |
| West Virginia | 90.1-2013 | 90.1-2013 |
| Wisconsin | IECC 2015 dan 90.1-2013^ | 90.1-2010 |
| Wyoming | Pemerintahan mandiri (Home rule) | Tidak ada kode seluruh negara bagian |
- ^ Ketika amandemen yang memengaruhi efisiensi energi dapat dikuantifikasi menggunakan Model Bangunan Prototipe DOE, amandemen tersebut telah dicakup dalam analisis.
- Bagi negara bagian yang mengadopsi IECC dan 90.1, kode IECC biasanya dianalisis sebagai kode berlaku negara bagian dalam studi ini, kecuali untuk negara bagian dengan amandemen ekstensif terhadap IECC.
Design Guide Key Concepts for Open Offices
Designing an energy-efficient lighting control solution for open offices involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.

In an open office setting, the primary areas to consider for sensor placement are the main walkways and areas with high foot traffic. These areas are crucial for sensor placement as they are the main areas of human traffic:
- Cover Main Walkways: The main walkways in an open office are the areas with the highest foot traffic. Therefore, these should be the primary focus when placing sensors. Ceiling-mounted sensors are ideal for these areas as they provide a wide coverage area and are strategically placed to cover the entire length.
- Overlap Coverage on Walkways: To avoid blind spots, ensure that the coverage patterns of the sensors overlap along the walkways. This ensures continuous detection as people move through the space, preventing any gaps in sensor coverage.
- Use a Long Timeout: Given the size and activity level in open offices, use a longer timeout setting (15 or 20 minutes) on the sensors. This prevents the lights from turning off too soon when there’s no movement detected for a brief period.
- Consider Wall-Mounted Sensors: If the cubicle walls are short, consider using wall-mounted sensors in addition to ceiling-mounted ones. These can provide additional coverage and ensure that all areas of the office are monitored.
- Avoid Air Vents: Don’t place sensors near air vents. The vibration and airflow can reduce the effectiveness of the sensors. PIR sensors should not be within 4ft of an air vent, and ultrasonic sensors should not be within 6ft of an air vent.
- Manual Control: Incorporate manual controls that are integrated with the occupancy sensors. This allows for manual override to turn ON/OFF all lighting when necessary.
Produk & Solusi Unggulan
Fitur utama yang disertakan:
- Kontrol manual NYALA/MATI yang terintegrasi untuk semua pencahayaan
- Sensor vakansi (Hanya NYALA manual): Lampu harus dinyalakan secara manual saja
- Penundaan waktu yang dapat disesuaikan, pencahayaan secara otomatis padam sepenuhnya setelah 15 menit
- Tambahan: kit nirkabel multi-lokasi untuk memperluas jangkauan kontrol tanpa pengkabelan ulang
- Tambahan: tersedia beberapa pilihan pengkabelan untuk proyek konstruksi baru maupun renovasi.

Memenuhi Ketentuan Wajib
IECC – 2011
C405.2.1 Kontrol sensor penghuni
Kontrol sensor penghuni harus dipasang untuk mengontrol lampu di dalam ruangan.
For open offices < 300 sq. ft:
C405.2.1.1 Fungsi kontrol sensor penghuni
- Menyala manual atau menyala sebagian hingga tidak lebih dari daya 50%.
- Full off within 20 minutes after all occupants have left the space
- A manual control to turn off the lights.
For open offices > 300 sq. ft:
- The general lighting shall be controlled separately in control zones with floor areas not greater than 600 sq. ft within the open plan office space.
- In each control zone, the general lighting shall be permitted to automatically turn on within the control zone. In other unoccupied zones, the general lighting shall be permitted to turn on to < 20% full power(or unaffected).
- Automatically turn off general lighting in all control zones within 20 minutes after all occupants have left the space.
- In each control zone, the general lighting shall turn off or uniformly reduce lighting power to an unoccupied setpoint of < 20% full power within 20 minutes after all occupants have left.
ASHRAE 90.1 – 2022
For open offices in any sizes:
9.4.1.1 a Local control
There shall be one or more manual lighting control device that provides ON and OFF control
of all lighting in the space.
9.4.1.1 b Restricted to manual ON
None of the lighting shall be automatically turned on
9.4.1.1 c Restricted to partial automatic ON
No more than 50% of the lighting power for the general lighting shall be allowed to be automatically turned on
** NOTE: At least one 9.4.1.1 b or 9.4.1.1 c shall be implemented.
9.4.1.1 H Automatic full OFF control
All lighting in the space shall be automatically shut off within 20 minutes of all occupants leaving the space
Additionally, for open offices > 300 sq. ft:
9.4.1.1 g Automatic reduction control
The general lighting power in the space shall be automatically reduced by at least 50% within 15 minutes of all occupants leaving the space.
Title 24 – 2022
For open offices in any sizes:
130.1 (a) Manual area controls.
Each area enclosed by ceiling-height partitions shall provide lighting controls that allow the lighting in that area to be manually turned on and off.
130.1 (c) Shut-OFF Controls.
Additionally, for open offices <250 sq. ft:
130.1 (c) 5. Occupant sensing controls are required for specified offices.
Lighting shall be controlled with occupant sensing controls to automatically shut OFF all of the lighting in 20 minutes or less after the control zone is unoccupied that shall function either as:
- A. Occupant sensing controls (if 130.1(b) not required to have multi-level lighting controls); or
- B. Partial-ON occupant sensing controls, or
- C. Vacancy sensing controls, where all lighting responds to a manual ON input only
Additionally, for open offices > 250 sq. ft:
130.1 (c) 6. Full or partial-OFF occupant sensing controls are required for offices greater than 250 square feet.
In office spaces greater than 250 square feet, general lighting shall be controlled with occupant sensing controls that meet all of the following:
- Lighting shall be controlled separately in control zones not greater than 600 square feet. For luminaires with an embedded occupant sensor that are capable of reducing power independently from other luminaires, each luminaire can be considered its own control zone
- The occupant sensing controls shall uniformly reduce lighting power in the control zone by at least 80% full power(or off) in 20 minutes or less after the control zone is unoccupied.
- The occupant sensing controls shall automatically turn off lighting in ALL control zones in 20 minutes or less after the entire office space is unoccupied
- When occupancy is detected:
- in each control zone, lighting shall be allowed to automatically turn on to any level up to full power.
- in other control zones that are unoccupied, lighting shall operate at no more than 20% full power.
Let us hear you.
Let Rayzeek help design and deliver a bespoke energy-saving lighting solution for you.