Lobby
Discover the energy-saving potential of your lobby. Learn how to meet energy codes and reduce energy waste with our tailored solutions.

Transform Your Lobby into an Energy-Efficient Space
The lobby is often the first point of contact for visitors and employees in a commercial building. It’s a space that needs to be well-lit and welcoming at all times. It’s a bustling area, filled with people coming and going at all hours. The lighting in these areas is typically high-intensity and left on for extended periods, leading to significant energy consumption.
Traditional lighting systems in lobbies are often manually controlled, resulting in lights being left on unnecessarily when the space is unoccupied, leading to high energy waste. Moreover, the diverse activities and varying occupancy levels in lobbies make it challenging to manage lighting efficiently. This not only increases operational costs but also contributes to a larger carbon footprint.
To address these issues, occupancy sensors offer an effective solution. These devices can automatically turn off or dim the lights when the lobby is vacant, significantly reducing energy consumption. Rayzeek’s range of occupancy sensors, including wall and ceiling-mounted options, provide a tailored solution for lobbies, ensuring efficient lighting control without compromising on comfort or safety.
Respecter les codes de l'énergie

L'IECC (International Energy Conservation Code) est un code modèle élaboré par l'ICC (International Code Council) afin d'établir les exigences minimales de conception et de construction pour l'efficacité énergétique des bâtiments. L'IECC est mis à jour tous les trois ans pour intégrer les dernières pratiques et technologies en matière d'économies d'énergie.
IECC, pourquoi vous devriez vous en soucier
L'IECC est largement adopté par les États et les municipalités à travers les États-Unis. L'IECC couvre divers aspects de la consommation d'énergie, notamment l'enveloppe du bâtiment (murs, toits et fenêtres), les systèmes de chauffage et de refroidissement, ainsi que les systèmes d'éclairage.
L'IECC impose des commandes d'éclairage spécifiques, telles que des détecteurs de présence, afin de minimiser le gaspillage d'énergie dans les espaces inoccupés de diverses zones.

La norme ANSI/ASHRAE/IES 90.1, Norme énergétique pour les sites et les bâtiments à l'exclusion des bâtiments résidentiels bas, est une norme énergétique largement reconnue publiée par l'American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).
ASHRAE 90.1, pourquoi vous devriez vous en soucier
La norme ASHRAE 90.1 sert de référence pour les codes énergétiques du bâtiment à travers les États-Unis et constitue une voie de conformité au sein de l'IECC. Elle définit les exigences minimales en matière de performance d'efficacité énergétique des composants des bâtiments commerciaux, y compris les enveloppes de bâtiment, les systèmes CVC, les systèmes de chauffage de l'eau et les systèmes d'éclairage.
La norme ASHRAE 90.1 spécifie les densités de puissance d'éclairage maximales autorisées et les exigences minimales en matière de contrôle de l'éclairage, notamment l'utilisation de détecteurs de présence dans des zones spécifiques.

Titre 24, partie 6 du California Building Standards Code, officiellement connu sous le nom de Building Energy Efficiency Standards for Residential and Nonresidential Buildings, le Titre 24 est administré par la California Energy Commission et est mis à jour périodiquement pour refléter les nouvelles technologies et méthodes d'efficacité énergétique.
Titre 24, pourquoi vous devriez vous en soucier
Le Titre 24 est reconnu pour ses exigences rigoureuses, souvent considérées comme plus strictes que celles de nombreux autres codes énergétiques aux États-Unis. Le Titre 24 impose des normes de performance énergétique strictes pour tous les aspects de la construction de bâtiments, ce qui comprend le chauffage, la ventilation, la climatisation (CVC), le chauffage de l'eau et l'éclairage.
Le Titre 24 exige l'installation de détecteurs de présence qui ajustent l'éclairage en fonction de l'occupation des pièces dans des zones spécifiques des bâtiments commerciaux pour garantir que l'énergie ne soit pas gaspillée.
Adoption des codes énergétiques par État

Développer pour voir le tableau détaillé ↓
| État | Code commercial actuel | Catégorie d'efficacité du code commercial |
|---|---|---|
| Alabama | 90.1-2013 | 90.1-2013 |
| Alaska | Aucun à l'échelle de l'État | Pas de code à l'échelle de l'État |
| Arizona | Autonomie communale | <90.1-2007 |
| Arkansas | IECC 2009 et 90.1-2007 | 90.1-2007 |
| Californie | Normes d'efficacité énergétique des bâtiments de 2022 | 90.1-2019 |
| Colorado | Autonomie communale | Pas de code à l'échelle de l'État |
| Connecticut | IECC 2021 et 90.1-2019 | 90.1-2019 |
| Delaware | IECC 2018 et 90.1-2016 | 90.1-2013 |
| District de Columbia | 90.1-2013^ | 90.1-2019 |
| Floride | IECC 2021 et 90.1-2019^ | 90.1-2016 |
| Géorgie | IECC 2015 et 90.1-2013^ | 90.1-2013 |
| Hawaï | Autonomie communale | 90.1-2013 |
| Idaho | IECC 2018 et 90.1-2016 | 90.1-2013 |
| Illinois | IECC 2021 et 90.1-2019 | 90.1-2019 |
| Indiana | 90.1-2007 | 90.1-2007 |
| Iowa | IECC 2012 et ASHRAE 90.1-2010 | 90.1-2007 |
| Kansas | Autonomie communale | Pas de code à l'échelle de l'État |
| Kentucky | IECC 2012 et ASHRAE 90.1-2010 | 90.1-2007 |
| Louisiane | IECC 2021 et 90.1-2019^ | 90.1-2016 |
| Maine | IECC 2015 et ASHRAE 90.1-2013 | 90.1-2013 |
| Maryland | IECC 2021 et 90.1-2019^ | 90.1-2019 |
| Massachusetts | IECC 2018 et ASHRAE 90.1-2016^ | 90.1-2019 |
| Michigan | IECC 2015 et 90.1-2013^ | 90.1-2013 |
| Minnesota | 90.1-2019^ | 90.1-2019 |
| Mississippi | Aucun à l'échelle de l'État | Pas de code à l'échelle de l'État |
| Missouri | Autonomie communale | Pas de code à l'échelle de l'État |
| Montana | IECC 2021 et 90.1-2019 | 90.1-2019 |
| Nebraska | IECC 2018 et 90.1-2016 | 90.1-2013 |
| Nevada | IECC 2018 et 90.1-2016 | 90.1-2013 |
| Nouveau-Hampshire | IECC 2018 et ASHRAE 90.1-2016^ | 90.1-2013 |
| New Jersey | 90.1-2019 | 90.1-2019 |
| Nouveau-Mexique | IECC 2021 et 90.1-2019^ | 90.1-2019 |
| New York | IECC 2018 et ASHRAE 90.1-2016^ | 90.1-2016 |
| Caroline du Nord | IECC 2015 et 90.1-2013^ | 90.1-2010 |
| Dakota du Nord | Autonomie communale | Pas de code à l'échelle de l'État |
| Ohio | IECC 2021 et 90.1-2019^ | 90.1-2016 |
| Oklahoma | 2006 IECC et 90.1-2004 | <90.1-2007 |
| Oregon | 90.1-2019 | 90.1-2019 |
| Pennsylvanie | IECC 2018 et 90.1-2016 | 90.1-2013 |
| Rhode Island | IECC 2018 et ASHRAE 90.1-2016^ | 90.1-2013 |
| Caroline du Sud | IECC 2009 et 90.1-2007 | 90.1-2007 |
| Dakota du Sud | Autonomie communale | Pas de code à l'échelle de l'État |
| Tennessee | 2021 IECC et 90.1-2013 | 90.1-2007 |
| Texas | IECC 2015 et ASHRAE 90.1-2013 | 90.1-2013 |
| Utah | IECC 2021 et 90.1-2019^ | 90.1-2019 |
| Vermont | IECC 2021 et 90.1-2019^ | 90.1-2019 |
| Virginie | IECC 2021 et 90.1-2019^ | 90.1-2019 |
| Washington | Code de l'énergie de l'État de Washington 2018 | 90.1-2019 |
| Tennessee | IECC 2012 et ASHRAE 90.1-2010 | 90.1-2007 |
| Texas | IECC 2015 et ASHRAE 90.1-2013 | 90.1-2013 |
| Utah | IECC 2021 et 90.1-2019^ | 90.1-2019 |
| Vermont | IECC 2018 et ASHRAE 90.1-2016^ | 90.1-2019 |
| Virginie | IECC 2021 et 90.1-2019^ | 90.1-2019 |
| Washington | Code de l'énergie de l'État de Washington 2018 | 90.1-2019 |
| Gaspésie–Îles-de-la-Madeleine / Virginie-Occidentale | 90.1-2013 | 90.1-2013 |
| Wisconsin | IECC 2015 et 90.1-2013^ | 90.1-2010 |
| Wyoming | Autonomie communale | Pas de code à l'échelle de l'État |
- ^ Lorsqu'un amendement ayant un impact sur l'efficacité énergétique peut être quantifié à l'aide des modèles de bâtiments prototypes du DOE, il a été pris en compte dans l'analyse.
- Pour les États adoptant à la fois l'IECC et la norme 90.1, le code IECC est généralement analysé comme le code en vigueur de l'État dans cette étude, à l'exception des États ayant apporté des amendements importants à l'IECC.
Design Guide Key Concepts for Lobby
Designing an energy-efficient lighting control solution for lobby involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.

In a lobby, the primary areas that need to be covered by occupancy sensors are the entrance, the reception desk, and any seating or waiting areas. Here’s a possible design guide for a lobby:
- Zone d'entrée: Install a ceiling occupancy sensor near the entrance. This sensor will detect the movement of people entering or exiting the lobby, ensuring the lights are activated when needed. Our ceiling sensors offer Auto ON and Full OFF functionality, providing automatic control of lighting based on occupancy.
- Main Lobby Area: For larger lobbies, additional ceiling sensors may be required to cover the entire space. These sensors should be strategically placed to cover high-traffic areas, such as near the reception desk or waiting areas. The overlapping coverage of multiple sensors ensures there are no blind spots.
- Reception Desk: Place a wall-mounted sensor near the reception desk. This sensor will detect the presence of the receptionist and any visitors at the desk, keeping the lights on in this area during occupied periods.
- Seating/Waiting Areas: Install additional ceiling-mounted sensors in any seating or waiting areas. These sensors will detect when these areas are occupied and adjust the lighting accordingly.
- Commande manuelle: Install a manual control near the entrance or reception desk. This allows for manual override of the lighting system when necessary.
- Corridors Leading to Other Areas: Corridors leading to elevators, staircases, or other parts of the building should have their own wall or ceiling-mounted sensors. This ensures that lights in these areas are only activated when someone is passing through.
Produits et solutions en vedette
Caractéristiques principales incluses :
- Commande manuelle Marche/Arrêt intégrée pour l'ensemble de l'éclairage
- Détecteurs d'absence (allumage manuel uniquement) : les lumières doivent être allumées uniquement de manière manuelle
- Temporisation réglable, l'éclairage s'éteint automatiquement et complètement au bout de 15 min
- En option : kits sans fil multi-emplacements pour étendre la portée de contrôle sans re-câblage
- En option : plusieurs options de câblage disponibles pour les nouvelles constructions et les projets de rénovation.

Conforme aux dispositions obligatoires
IECC – 2011
C405.2.1 Commandes par détecteur de présence
Des commandes par détecteur de présence doivent être installées pour contrôler l'éclairage dans l'espace.
C405.2.1.1 Fonctions de commande par détecteur de présence
- Allumage manuel ou allumage partiel à pas plus de 50% de puissance.
- Extinction complète dans les 20 minutes suivant le départ de tous les occupants de l'espace
- Une commande manuelle pour éteindre les lumières.
Full automatic-on controls with no manual control are permitted in lobbies where manual operation would endanger occupant safety or security.
ASHRAE 90.1 – 2022
9.4.1.1 a Commande locale
Il doit y avoir un ou plusieurs dispositifs de commande manuelle de l'éclairage assurant le contrôle MARCHE et ARRÊT
de tout l'éclairage de l'espace.
9.4.1.1 g Automatic reduction control
The general lighting power in the space shall be automatically reduced by at least 50% within 15 minutes of all occupants leaving the space.
** NOTE: 9.4.1.1 g is required in all other lobbies except (Elevator, Hotel, Motion picture theater, Performing arts theater)
9.4.1.1 h Automatic full OFF control
All lighting in the space shall be automatically shut off within 15 minutes of all occupants leaving the space.
9.4.1.1 i Scheduled shutoff
All lighting in the space shall be automatically shut off during periods when the space is scheduled to be unoccupied.
** NOTE: At least one 9.4.1.1 h or 9.4.1.1 i shall be implemented.
Titre 24 – 2022
130.1 (a) Commandes manuelles de zone.
Chaque zone délimitée par des cloisons jusqu'au plafond doit être équipée de commandes d'éclairage permettant d'allumer et d'éteindre manuellement l'éclairage de cette zone.
130.1 (c) Commandes d'extinction.
L'éclairage doit être contrôlé par des détecteurs de présence afin d'éteindre automatiquement tout l'éclairage dans un délai maximal de 20 minutes après que la zone de contrôle n'est plus occupée, fonctionnant soit comme :
- A. Commandes par détecteur de présence (si la section 130.1(b) ne requiert pas de commandes d'éclairage multiniveau) ; ou
- B. Commandes par détecteur de présence avec allumage partiel (Partial-ON), ou
- C. Commandes par détecteur d'absence, où tout l'éclairage réagit uniquement à une commande d'allumage manuel
Faites-nous part de vos besoins.
Laissez Rayzeek vous aider à concevoir et à fournir une solution d'éclairage sur mesure à économie d'énergie.