Discover the energy-saving potential of your lobby. Learn how to meet energy codes and reduce energy waste with our tailored solutions.

Transform Your Lobby into an Energy-Efficient Space
The lobby is often the first point of contact for visitors and employees in a commercial building. It’s a space that needs to be well-lit and welcoming at all times. It’s a bustling area, filled with people coming and going at all hours. The lighting in these areas is typically high-intensity and left on for extended periods, leading to significant energy consumption.
Traditional lighting systems in lobbies are often manually controlled, resulting in lights being left on unnecessarily when the space is unoccupied, leading to high energy waste. Moreover, the diverse activities and varying occupancy levels in lobbies make it challenging to manage lighting efficiently. This not only increases operational costs but also contributes to a larger carbon footprint.
To address these issues, occupancy sensors offer an effective solution. These devices can automatically turn off or dim the lights when the lobby is vacant, significantly reducing energy consumption. Rayzeek’s range of occupancy sensors, including wall and ceiling-mounted options, provide a tailored solution for lobbies, ensuring efficient lighting control without compromising on comfort or safety.
ऊर्जा कोड का अनुपालन करें

इंटरनेशनल एनर्जी कंजर्वेशन कोड (IECC) इंटरनेशनल कोड काउंसिल (ICC) द्वारा विकसित एक मॉडल कोड है जो भवनों में ऊर्जा दक्षता के लिए न्यूनतम डिजाइन और निर्माण आवश्यकताओं को स्थापित करता है। ऊर्जा संरक्षण प्रथाओं और प्रौद्योगिकियों में नवीनतम नवाचारों को शामिल करने के लिए IECC को हर तीन साल में अपडेट किया जाता है।
IECC, आपको इस पर ध्यान क्यों देना चाहिए
IECC को संयुक्त राज्य भर के राज्यों और नगर पालिकाओं द्वारा व्यापक रूप से अपनाया गया है। IECC ऊर्जा उपयोग के विभिन्न पहलुओं को कवर करता है, जिसमें बिल्डिंग लिफाफा (दीवारें, छतें और खिड़कियां), हीटिंग और कूलिंग सिस्टम और लाइटिंग सिस्टम शामिल हैं।
IECC विभिन्न क्षेत्रों में खाली पड़े स्थानों में ऊर्जा की बर्बादी को कम करने के लिए विशिष्ट लाइटिंग नियंत्रणों, जैसे ऑक्यूपेंसी सेंसर, का आदेश देता है।

ANSI/ASHRAE/IES मानक 90.1, कम ऊंचाई वाले आवासीय भवनों को छोड़कर साइटों और भवनों के लिए ऊर्जा मानक, अमेरिकन सोसाइटी ऑफ हीटिंग, रेफ्रिजरेटिंग एंड एयर-कंडीशनिंग इंजीनियर्स (ASHRAE) द्वारा प्रकाशित एक व्यापक रूप से मान्यता प्राप्त ऊर्जा मानक है।
ASHRAE 90.1, आपको इस पर ध्यान क्यों देना चाहिए
ASHRAE 90.1 का उपयोग पूरे संयुक्त राज्य अमेरिका में बिल्डिंग ऊर्जा कोड के लिए एक बेंचमार्क के रूप में किया जाता है और यह IECC के भीतर एक अनुपालन मार्ग के रूप में कार्य करता है जो वाणिज्यिक भवनों के घटकों जैसे बिल्डिंग लिफाफे, HVAC सिस्टम, वॉटर हीटिंग सिस्टम और लाइटिंग सिस्टम के ऊर्जा-कुशल प्रदर्शन के लिए न्यूनतम आवश्यकताओं की रूपरेखा तैयार करता है।
ASHRAE 90.1 मानक अधिकतम स्वीकार्य लाइटिंग पावर घनत्व और न्यूनतम लाइटिंग नियंत्रण आवश्यकताओं को निर्दिष्ट करता है, जिसमें विशिष्ट क्षेत्रों में ऑक्यूपेंसी सेंसर का उपयोग शामिल है।

कैलिफोर्निया बिल्डिंग स्टैंडर्ड्स कोड का शीर्षक 24, भाग 6, जिसे आधिकारिक तौर पर आवासीय और गैर-आवासीय भवनों के लिए भवन ऊर्जा दक्षता मानक के रूप में जाना जाता है, शीर्षक 24 कैलिफोर्निया ऊर्जा आयोग द्वारा प्रशासित किया जाता है और नई ऊर्जा दक्षता प्रौद्योगिकियों और विधियों को दर्शाने के लिए समय-समय पर अपडेट किया जाता है।
शीर्षक 24, आपको इस पर ध्यान क्यों देना चाहिए
शीर्षक 24 अपनी कठोर आवश्यकताओं के लिए जाना जाता है, जिसे अक्सर संयुक्त राज्य अमेरिका के कई अन्य ऊर्जा कोडों की तुलना में अधिक सख्त माना जाता है। शीर्षक 24 भवन निर्माण के सभी पहलुओं के लिए सख्त ऊर्जा प्रदर्शन मानकों का आदेश देता है, जिसमें हीटिंग, वेंटिलेशन, एयर कंडीशनिंग (HVAC), वॉटर हीटिंग और लाइटिंग शामिल हैं।
शीर्षक 24 में ऑक्यूपेंसी सेंसर लगाने की आवश्यकता होती है जो व्यावसायिक भवनों के विशिष्ट क्षेत्रों में कमरे में उपस्थिति के आधार पर प्रकाश को समायोजित करते हैं ताकि यह सुनिश्चित किया जा सके कि ऊर्जा बर्बाद न हो।
राज्य द्वारा ऊर्जा कोड अपनाना

विस्तृत तालिका देखने के लिए विस्तार करें ↓
| राज्य | वर्तमान व्यावसायिक कोड | व्यावसायिक कोड दक्षता श्रेणी |
|---|---|---|
| अलबामा | 90.1-2013 | 90.1-2013 |
| अलास्का | राज्य भर में कोई नहीं | राज्य स्तर पर कोई कोड नहीं |
| एरिज़ोना | होम रूल | <90.1-2007 |
| अरकांसस | 2009 IECC और 90.1-2007 | 90.1-2007 |
| कैलिफ़ोर्निया | 2022 Building Energy Efficiency Standards | 90.1-2019 |
| Colorado | होम रूल | राज्य स्तर पर कोई कोड नहीं |
| Connecticut | 2021 IECC and 90.1-2019 | 90.1-2019 |
| Delaware | 2018 IECC and 90.1-2016 | 90.1-2013 |
| District of Columbia | 90.1-2013^ | 90.1-2019 |
| Florida | 2021 IECC and 90.1-2019^ | 90.1-2016 |
| Georgia | 2015 IECC and 90.1-2013^ | 90.1-2013 |
| Hawaii | होम रूल | 90.1-2013 |
| Idaho | 2018 IECC and 90.1-2016 | 90.1-2013 |
| Illinois | 2021 IECC and 90.1-2019 | 90.1-2019 |
| Indiana | 90.1-2007 | 90.1-2007 |
| Iowa | 2012 IECC and 90.1-2010 | 90.1-2007 |
| Kansas | होम रूल | राज्य स्तर पर कोई कोड नहीं |
| Kentucky | 2012 IECC and 90.1-2010 | 90.1-2007 |
| Louisiana | 2021 IECC and 90.1-2019^ | 90.1-2016 |
| Maine | 2015 IECC and 90.1-2013 | 90.1-2013 |
| Maryland | 2021 IECC and 90.1-2019^ | 90.1-2019 |
| Massachusetts | 2018 IECC and 90.1-2016^ | 90.1-2019 |
| Michigan | 2015 IECC and 90.1-2013^ | 90.1-2013 |
| Minnesota | 90.1-2019^ | 90.1-2019 |
| Mississippi | राज्य भर में कोई नहीं | राज्य स्तर पर कोई कोड नहीं |
| Missouri | होम रूल | राज्य स्तर पर कोई कोड नहीं |
| Montana | 2021 IECC and 90.1-2019 | 90.1-2019 |
| Nebraska | 2018 IECC and 90.1-2016 | 90.1-2013 |
| Nevada | 2018 IECC and 90.1-2016 | 90.1-2013 |
| New Hampshire | 2018 IECC and 90.1-2016^ | 90.1-2013 |
| New Jersey | 90.1-2019 | 90.1-2019 |
| New Mexico | 2021 IECC and 90.1-2019^ | 90.1-2019 |
| New York | 2018 IECC and 90.1-2016^ | 90.1-2016 |
| North Carolina | 2015 IECC and 90.1-2013^ | 90.1-2010 |
| North Dakota | होम रूल | राज्य स्तर पर कोई कोड नहीं |
| Ohio | 2021 IECC and 90.1-2019^ | 90.1-2016 |
| Oklahoma | 2006 IECC and 90.1-2004 | <90.1-2007 |
| Oregon | 90.1-2019 | 90.1-2019 |
| Pennsylvania | 2018 IECC and 90.1-2016 | 90.1-2013 |
| Rhode Island | 2018 IECC and 90.1-2016^ | 90.1-2013 |
| South Carolina | 2009 IECC और 90.1-2007 | 90.1-2007 |
| South Dakota | होम रूल | राज्य स्तर पर कोई कोड नहीं |
| Tennessee | 2021 IECC and 90.1-2013 | 90.1-2007 |
| Texas | 2015 IECC and 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC and 90.1-2019^ | 90.1-2019 |
| Vermont | 2021 IECC and 90.1-2019^ | 90.1-2019 |
| Virginia | 2021 IECC and 90.1-2019^ | 90.1-2019 |
| Washington | 2018 Washington State Energy Code | 90.1-2019 |
| Tennessee | 2012 IECC and 90.1-2010 | 90.1-2007 |
| Texas | 2015 IECC and 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC and 90.1-2019^ | 90.1-2019 |
| Vermont | 2018 IECC and 90.1-2016^ | 90.1-2019 |
| Virginia | 2021 IECC and 90.1-2019^ | 90.1-2019 |
| Washington | 2018 Washington State Energy Code | 90.1-2019 |
| West Virginia | 90.1-2013 | 90.1-2013 |
| Wisconsin | 2015 IECC and 90.1-2013^ | 90.1-2010 |
| Wyoming | होम रूल | राज्य स्तर पर कोई कोड नहीं |
- ^ When an amendment impacting energy efficiency can be quantified using DOE Prototype Building Models, they were captured in the analysis.
- For states adopting both IECC and 90.1, the IECC code is usually analyzed as the state current code in this study except for states with extensive amendments to the IECC.
Design Guide Key Concepts for Lobby
Designing an energy-efficient lighting control solution for lobby involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.

In a lobby, the primary areas that need to be covered by occupancy sensors are the entrance, the reception desk, and any seating or waiting areas. Here’s a possible design guide for a lobby:
- Entrance Area: Install a ceiling occupancy sensor near the entrance. This sensor will detect the movement of people entering or exiting the lobby, ensuring the lights are activated when needed. Our ceiling sensors offer Auto ON and Full OFF functionality, providing automatic control of lighting based on occupancy.
- Main Lobby Area: For larger lobbies, additional ceiling sensors may be required to cover the entire space. These sensors should be strategically placed to cover high-traffic areas, such as near the reception desk or waiting areas. The overlapping coverage of multiple sensors ensures there are no blind spots.
- Reception Desk: Place a wall-mounted sensor near the reception desk. This sensor will detect the presence of the receptionist and any visitors at the desk, keeping the lights on in this area during occupied periods.
- Seating/Waiting Areas: Install additional ceiling-mounted sensors in any seating or waiting areas. These sensors will detect when these areas are occupied and adjust the lighting accordingly.
- Manual Control: Install a manual control near the entrance or reception desk. This allows for manual override of the lighting system when necessary.
- Corridors Leading to Other Areas: Corridors leading to elevators, staircases, or other parts of the building should have their own wall or ceiling-mounted sensors. This ensures that lights in these areas are only activated when someone is passing through.
Featured Products & Solutions
Core features included:
- Integrated manual ON/OFF control for all lighting
- Vacancy sensors (Manual ON only): Lights must be turned on manually only
- Adjustable time-delay, lighting is automatically turned full OFF after 15mins
- Additional: multi-location wireless kits to expand the control range without re-wring
- Additional: multiple wiring options available for both new constructions and retrofit projects.

Meets the Mandatory Provisions
IECC – 2011
C405.2.1 Occupant sensor controls
Occupant sensor controls shall be installed to control lights in the space.
C405.2.1.1 Occupant sensor control functions
- Manual on or partial on to no more than 50% power.
- Full off within 20 minutes after all occupants have left the space
- A manual control to turn off the lights.
Full automatic-on controls with no manual control are permitted in lobbies where manual operation would endanger occupant safety or security.
ASHRAE 90.1 – 2022
9.4.1.1 a Local control
There shall be one or more manual lighting control device that provides ON and OFF control
of all lighting in the space.
9.4.1.1 g Automatic reduction control
The general lighting power in the space shall be automatically reduced by at least 50% within 15 minutes of all occupants leaving the space.
** NOTE: 9.4.1.1 g is required in all other lobbies except (Elevator, Hotel, Motion picture theater, Performing arts theater)
9.4.1.1 h Automatic full OFF control
All lighting in the space shall be automatically shut off within 15 minutes of all occupants leaving the space.
9.4.1.1 i Scheduled shutoff
All lighting in the space shall be automatically shut off during periods when the space is scheduled to be unoccupied.
** NOTE: At least one 9.4.1.1 h or 9.4.1.1 i shall be implemented.
Title 24 – 2022
130.1 (a) Manual area controls.
Each area enclosed by ceiling-height partitions shall provide lighting controls that allow the lighting in that area to be manually turned on and off.
130.1 (c) Shut-OFF Controls.
Lighting shall be controlled with occupant sensing controls to automatically shut OFF all of the lighting in 20 minutes or less after the control zone is unoccupied that shall function either as:
- A. Occupant sensing controls (if 130.1(b) not required to have multi-level lighting controls); or
- B. Partial-ON occupant sensing controls, or
- C. Vacancy sensing controls, where all lighting responds to a manual ON input only