Lobby
Upptäck energibesparingspotentialen i er entréhall. Lär dig hur ni uppfyller energikrav och minskar energisvinn med våra skräddarsydda lösningar.

Transform Your Lobby into an Energy-Efficient Space
The lobby is often the first point of contact for visitors and employees in a commercial building. It’s a space that needs to be well-lit and welcoming at all times. It’s a bustling area, filled with people coming and going at all hours. The lighting in these areas is typically high-intensity and left on for extended periods, leading to significant energy consumption.
Traditional lighting systems in lobbies are often manually controlled, resulting in lights being left on unnecessarily when the space is unoccupied, leading to high energy waste. Moreover, the diverse activities and varying occupancy levels in lobbies make it challenging to manage lighting efficiently. This not only increases operational costs but also contributes to a larger carbon footprint.
To address these issues, occupancy sensors offer an effective solution. These devices can automatically turn off or dim the lights when the lobby is vacant, significantly reducing energy consumption. Rayzeek’s range of occupancy sensors, including wall and ceiling-mounted options, provide a tailored solution for lobbies, ensuring efficient lighting control without compromising on comfort or safety.
Uppfyll energireglerna

International Energy Conservation Code (IECC) är en modellkod framtagen av International Code Council (ICC) för att fastställa minimikrav för utformning och konstruktion avseende energieffektivitet i byggnader. IECC uppdateras vart tredje år för att inkludera de senaste metoderna och teknikerna inom energibesparing.
IECC – Varför du bör bry dig
IECC har antagits i stor utsträckning av delstater och kommuner över hela USA. IECC omfattar olika aspekter av energianvändning, inklusive byggnadsskalet (väggar, tak och fönster), värme- och kylsystem samt belysningssystem.
IECC föreskriver specifik belysningsstyrning, såsom närvarosensorer, för att minimera energislöseri i outnyttjade utrymmen i olika områden.

ANSI/ASHRAE/IES Standard 90.1, Energy Standard for Sites and Buildings Except Low-Rise Residential Buildings, är en allmänt erkänd energistandard som publiceras av American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).
ASHRAE 90.1 – Varför du bör bry dig
ASHRAE 90.1 används som riktmärke för energikoder för byggnader i hela USA och fungerar som en efterlevnadsväg inom IECC, vilken anger minimikrav för energieffektiva prestanda hos komponenter i kommersiella byggnader, inklusive byggnadsskal, VVS-system, varmvattensystem och belysningssystem.
Standarden ASHRAE 90.1 anger maximalt tillåtna belysningseffekttätheter och minimikrav på belysningsstyrning, inklusive användning av närvarosensorer inom specifika områden.

Title 24, del 6 i California Building Standards Code, officiellt känd som Building Energy Efficiency Standards for Residential and Nonresidential Buildings, administreras av California Energy Commission och uppdateras regelbundet för att återspegla ny teknik och nya metoder för energieffektivitet.
Title 24 – Varför du bör bry dig
Title 24 är känd för sina stränga krav, vilka ofta anses vara striktare än de som finns i många andra energikoder i USA. Title 24 föreskriver strikta energiprestandastandarder för alla aspekter av byggnadskonstruktion, vilket inkluderar uppvärmning, ventilation, luftkonditionering (VVS), varmvatten och belysning.
Title 24 kräver installation av närvarosensorer som anpassar belysningen baserat på rumsutnyttjande i specifika utrymmen i kommersiella byggnader för att säkerställa att energi inte slösas bort.
Införande av energikoder per delstat

Expandera för att se den utförliga tabellen ↓
| Delstat | Gällande kommersiella föreskrifter | Effektivitetskategori för kommersiella föreskrifter |
|---|---|---|
| Alabama | 90.1-2013 | 90.1-2013 |
| Alaska | Inga delstatsövergripande | Inga delstatsövergripande föreskrifter |
| Arizona | Lokal självstyre | <90.1-2007 |
| Arkansas | 2009 IECC och 90.1-2007 | 90.1-2007 |
| Kalifornien | 2022 Building Energy Efficiency Standards | 90.1-2019 |
| Colorado | Lokal självstyre | Inga delstatsövergripande föreskrifter |
| Connecticut | 2021 IECC och 90.1-2019 | 90.1-2019 |
| Delaware | 2018 IECC och 90.1-2016 | 90.1-2013 |
| District of Columbia | 90.1-2013^ | 90.1-2019 |
| Florida | 2021 IECC and 90.1-2019^ | 90.1-2016 |
| Georgia | 2015 IECC and 90.1-2013^ | 90.1-2013 |
| Hawaii | Lokal självstyre | 90.1-2013 |
| Idaho | 2018 IECC och 90.1-2016 | 90.1-2013 |
| Illinois | 2021 IECC och 90.1-2019 | 90.1-2019 |
| Indiana | 90.1-2007 | 90.1-2007 |
| Iowa | 2012 IECC and 90.1-2010 | 90.1-2007 |
| Kansas | Lokal självstyre | Inga delstatsövergripande föreskrifter |
| Kentucky | 2012 IECC and 90.1-2010 | 90.1-2007 |
| Louisiana | 2021 IECC and 90.1-2019^ | 90.1-2016 |
| Maine | 2015 IECC och 90.1-2013 | 90.1-2013 |
| Maryland | 2021 IECC and 90.1-2019^ | 90.1-2019 |
| Massachusetts | 2018 IECC och 90.1-2016^ | 90.1-2019 |
| Michigan | 2015 IECC and 90.1-2013^ | 90.1-2013 |
| Minnesota | 90.1-2019^ | 90.1-2019 |
| Mississippi | Inga delstatsövergripande | Inga delstatsövergripande föreskrifter |
| Missouri | Lokal självstyre | Inga delstatsövergripande föreskrifter |
| Montana | 2021 IECC och 90.1-2019 | 90.1-2019 |
| Nebraska | 2018 IECC och 90.1-2016 | 90.1-2013 |
| Nevada | 2018 IECC och 90.1-2016 | 90.1-2013 |
| New Hampshire | 2018 IECC och 90.1-2016^ | 90.1-2013 |
| New Jersey | 90.1-2019 | 90.1-2019 |
| New Mexico | 2021 IECC and 90.1-2019^ | 90.1-2019 |
| New York | 2018 IECC och 90.1-2016^ | 90.1-2016 |
| North Carolina | 2015 IECC and 90.1-2013^ | 90.1-2010 |
| North Dakota | Lokal självstyre | Inga delstatsövergripande föreskrifter |
| Ohio | 2021 IECC and 90.1-2019^ | 90.1-2016 |
| Oklahoma | 2006 IECC och 90.1-2004 | <90.1-2007 |
| Oregon | 90.1-2019 | 90.1-2019 |
| Pennsylvania | 2018 IECC och 90.1-2016 | 90.1-2013 |
| Rhode Island | 2018 IECC och 90.1-2016^ | 90.1-2013 |
| South Carolina | 2009 IECC och 90.1-2007 | 90.1-2007 |
| South Dakota | Lokal självstyre | Inga delstatsövergripande föreskrifter |
| Tennessee | 2021 IECC and 90.1-2013 | 90.1-2007 |
| Texas | 2015 IECC och 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC and 90.1-2019^ | 90.1-2019 |
| Vermont | 2021 IECC and 90.1-2019^ | 90.1-2019 |
| Virginia | 2021 IECC and 90.1-2019^ | 90.1-2019 |
| Washington | 2018 Washington State Energy Code | 90.1-2019 |
| Tennessee | 2012 IECC and 90.1-2010 | 90.1-2007 |
| Texas | 2015 IECC och 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC and 90.1-2019^ | 90.1-2019 |
| Vermont | 2018 IECC och 90.1-2016^ | 90.1-2019 |
| Virginia | 2021 IECC and 90.1-2019^ | 90.1-2019 |
| Washington | 2018 Washington State Energy Code | 90.1-2019 |
| West Virginia | 90.1-2013 | 90.1-2013 |
| Wisconsin | 2015 IECC and 90.1-2013^ | 90.1-2010 |
| Wyoming | Lokal självstyre | Inga delstatsövergripande föreskrifter |
- ^ When an amendment impacting energy efficiency can be quantified using DOE Prototype Building Models, they were captured in the analysis.
- For states adopting both IECC and 90.1, the IECC code is usually analyzed as the state current code in this study except for states with extensive amendments to the IECC.
Viktiga designprinciper för entréhallar och lobbyer
Att utforma en energieffektiv belysningsstyrningslösning för en lobby kräver en strategisk placering av närvarosensorer för att säkerställa en heltäckande bevakning av utrymmet.

In a lobby, the primary areas that need to be covered by occupancy sensors are the entrance, the reception desk, and any seating or waiting areas. Here’s a possible design guide for a lobby:
- Entrance Area: Install a ceiling occupancy sensor near the entrance. This sensor will detect the movement of people entering or exiting the lobby, ensuring the lights are activated when needed. Our ceiling sensors offer Auto ON and Full OFF functionality, providing automatic control of lighting based on occupancy.
- Main Lobby Area: For larger lobbies, additional ceiling sensors may be required to cover the entire space. These sensors should be strategically placed to cover high-traffic areas, such as near the reception desk or waiting areas. The overlapping coverage of multiple sensors ensures there are no blind spots.
- Reception Desk: Place a wall-mounted sensor near the reception desk. This sensor will detect the presence of the receptionist and any visitors at the desk, keeping the lights on in this area during occupied periods.
- Seating/Waiting Areas: Install additional ceiling-mounted sensors in any seating or waiting areas. These sensors will detect when these areas are occupied and adjust the lighting accordingly.
- Manual Control: Install a manual control near the entrance or reception desk. This allows for manual override of the lighting system when necessary.
- Corridors Leading to Other Areas: Corridors leading to elevators, staircases, or other parts of the building should have their own wall or ceiling-mounted sensors. This ensures that lights in these areas are only activated when someone is passing through.
Featured Products & Solutions
Core features included:
- Integrated manual ON/OFF control for all lighting
- Vacancy sensors (Manual ON only): Lights must be turned on manually only
- Adjustable time-delay, lighting is automatically turned full OFF after 15mins
- Additional: multi-location wireless kits to expand the control range without re-wring
- Additional: multiple wiring options available for both new constructions and retrofit projects.

Meets the Mandatory Provisions
IECC – 2011
C405.2.1 Occupant sensor controls
Occupant sensor controls shall be installed to control lights in the space.
C405.2.1.1 Occupant sensor control functions
- Manual on or partial on to no more than 50% power.
- Full off within 20 minutes after all occupants have left the space
- A manual control to turn off the lights.
Full automatic-on controls with no manual control are permitted in lobbies where manual operation would endanger occupant safety or security.
ASHRAE 90.1 – 2022
9.4.1.1 a Local control
There shall be one or more manual lighting control device that provides ON and OFF control
of all lighting in the space.
9.4.1.1 g Automatic reduction control
The general lighting power in the space shall be automatically reduced by at least 50% within 15 minutes of all occupants leaving the space.
** NOTE: 9.4.1.1 g is required in all other lobbies except (Elevator, Hotel, Motion picture theater, Performing arts theater)
9.4.1.1 h Automatic full OFF control
All lighting in the space shall be automatically shut off within 15 minutes of all occupants leaving the space.
9.4.1.1 i Scheduled shutoff
All lighting in the space shall be automatically shut off during periods when the space is scheduled to be unoccupied.
** NOTE: At least one 9.4.1.1 h or 9.4.1.1 i shall be implemented.
Title 24 – 2022
130.1 (a) Manual area controls.
Each area enclosed by ceiling-height partitions shall provide lighting controls that allow the lighting in that area to be manually turned on and off.
130.1 (c) Shut-OFF Controls.
Lighting shall be controlled with occupant sensing controls to automatically shut OFF all of the lighting in 20 minutes or less after the control zone is unoccupied that shall function either as:
- A. Occupant sensing controls (if 130.1(b) not required to have multi-level lighting controls); or
- B. Partial-ON occupant sensing controls, or
- C. Vacancy sensing controls, where all lighting responds to a manual ON input only
Let us hear you.