البهو

اكتشف إمكانات توفير الطاقة في بهو مبناك. تعرّف على كيفية تلبية أكواد الطاقة وتقليل هدر الطاقة من خلال حلولنا المخصصة.

Transform Your Lobby into an Energy-Efficient Space

The lobby is often the first point of contact for visitors and employees in a commercial building. It’s a space that needs to be well-lit and welcoming at all times. It’s a bustling area, filled with people coming and going at all hours. The lighting in these areas is typically high-intensity and left on for extended periods, leading to significant energy consumption.

Traditional lighting systems in lobbies are often manually controlled, resulting in lights being left on unnecessarily when the space is unoccupied, leading to high energy waste. Moreover, the diverse activities and varying occupancy levels in lobbies make it challenging to manage lighting efficiently. This not only increases operational costs but also contributes to a larger carbon footprint.

To address these issues, occupancy sensors offer an effective solution. These devices can automatically turn off or dim the lights when the lobby is vacant, significantly reducing energy consumption. Rayzeek’s range of occupancy sensors, including wall and ceiling-mounted options, provide a tailored solution for lobbies, ensuring efficient lighting control without compromising on comfort or safety.

الامتثال للوائح القياسية للطاقة

قانون حفظ الطاقة الدولي (IECC) هو قانون نموذجي تم تطويره بواسطة مجلس القوانين الدولي (ICC) لوضع الحد الأدنى من متطلبات التصميم والبناء لكفاءة الطاقة في المباني. ويتم تحديث IECC كل ثلاث سنوات لإدماج أحدث الممارسات والتقنيات في مجال حفظ الطاقة.

قانون IECC: لماذا ينبغي أن تهتم به؟

يُطبق قانون IECC على نطاق واسع من قبل الولايات والبلديات في جميع أنحاء الولايات المتحدة. ويغطي IECC جوانب مختلفة من استخدام الطاقة، بما في ذلك غلاف المبنى (الجدران والأسقف والنوافذ)، وأنظمة التدفئة والتبريد، وأنظمة الإضاءة.

ينص قانون IECC على عناصر تحكم محددة في الإضاءة، مثل أجهزة استشعار الإشغال، للحد من هدر الطاقة في المساحات غير المشغولة في مختلف المناطق.

تُعد معايير ANSI/ASHRAE/IES Standard 90.1، الخاصة بطاقة المواقع والمباني باستثناء المباني السكنية منخفضة الارتفاع، معيارًا معترفًا به على نطاق واسع للطاقة، صادرًا عن الجمعية الأمريكية لمهندسي التدفئة والتبريد وتكييف الهواء (ASHRAE).

معيار ASHRAE 90.1: لماذا ينبغي أن تهتم به؟

يُستخدم معيار ASHRAE 90.1 كمرجع للوائح طاقة المباني في جميع أنحاء الولايات المتحدة، ويُعد مسارًا للامتثال ضمن قانون IECC، حيث يحدد الحد الأدنى من المتطلبات للأداء الموفر للطاقة لمكونات المباني التجارية، بما في ذلك أغلفة المباني، وأنظمة التدفئة والتهوية وتكييف الهواء (HVAC)، وأنظمة تسخين المياه، وأنظمة الإضاءة.

يحدد معيار ASHRAE 90.1 الحد الأقصى لكثافة قدرة الإضاءة المسموح بها والحد الأدنى لمتطلبات التحكم في الإضاءة، بما في ذلك استخدام أجهزة استشعار الإشغال في مناطق محددة.

العنوان 24، الجزء 6 من قانون معايير البناء في كاليفورنيا، المعروف رسميًا باسم معايير كفاءة طاقة المباني للمباني السكنية غير السكنية، تُديره لجنة الطاقة في كاليفورنيا ويتم تحديثه بشكل دوري ليعكس تقنيات وطرق كفاءة الطاقة الجديدة.

العنوان 24 (Title 24): لماذا ينبغي أن تهتم به؟

يشتهر العنوان 24 بمتطلباته الصارمة، والتي تُعتبر في كثير من الأحيان أكثر صرامة من تلك الموجودة في العديد من لوائح الطاقة الأخرى عبر الولايات المتحدة. وينص العنوان 24 على معايير صارمة لأداء الطاقة لكافة جوانب تشييد المباني، والتي تشمل التدفئة والتهوية وتكييف الهواء (HVAC)، وتسخين المياه، والإضاءة.

يتطلب العنوان 24 تركيب أجهزة استشعار الإشغال التي تضبط الإضاءة بناءً على إشغال الغرفة في مناطق محددة من المباني التجارية لضمان عدم هدر الطاقة.

اعتماد لوائح الطاقة حسب الولاية

قم بالتوسيع لعرض الجدول التفصيلي ↓

الولايةالقانون التجاري الحاليفئة كفاءة القانون التجاري
ألاباما90.1-201390.1-2013
ألاسكالا يوجد على مستوى الولايةلا يوجد قانون على مستوى الولاية
أريزوناالحكم المحلي<90.1-2007
أركنساس2009 IECC و 90.1-200790.1-2007
كاليفورنيا2022 Building Energy Efficiency Standards90.1-2019
Coloradoالحكم المحليلا يوجد قانون على مستوى الولاية
Connecticut2021 IECC and 90.1-201990.1-2019
Delaware2018 IECC and 90.1-201690.1-2013
District of Columbia90.1-2013^90.1-2019
Florida2021 IECC and 90.1-2019^90.1-2016
Georgia2015 IECC and 90.1-2013^90.1-2013
Hawaiiالحكم المحلي90.1-2013
Idaho2018 IECC and 90.1-201690.1-2013
Illinois2021 IECC and 90.1-201990.1-2019
Indiana90.1-200790.1-2007
Iowa2012 IECC and 90.1-201090.1-2007
Kansasالحكم المحليلا يوجد قانون على مستوى الولاية
Kentucky2012 IECC and 90.1-201090.1-2007
Louisiana2021 IECC and 90.1-2019^90.1-2016
Maine2015 IECC and 90.1-201390.1-2013
Maryland2021 IECC and 90.1-2019^90.1-2019
Massachusetts2018 IECC and 90.1-2016^90.1-2019
Michigan2015 IECC and 90.1-2013^90.1-2013
Minnesota90.1-2019^90.1-2019
Mississippiلا يوجد على مستوى الولايةلا يوجد قانون على مستوى الولاية
Missouriالحكم المحليلا يوجد قانون على مستوى الولاية
Montana2021 IECC and 90.1-201990.1-2019
Nebraska2018 IECC and 90.1-201690.1-2013
Nevada2018 IECC and 90.1-201690.1-2013
New Hampshire2018 IECC and 90.1-2016^90.1-2013
New Jersey90.1-201990.1-2019
New Mexico2021 IECC and 90.1-2019^90.1-2019
New York2018 IECC and 90.1-2016^90.1-2016
North Carolina2015 IECC and 90.1-2013^90.1-2010
North Dakotaالحكم المحليلا يوجد قانون على مستوى الولاية
Ohio2021 IECC and 90.1-2019^90.1-2016
Oklahoma2006 IECC and 90.1-2004<90.1-2007
Oregon90.1-201990.1-2019
Pennsylvania2018 IECC and 90.1-201690.1-2013
Rhode Island2018 IECC and 90.1-2016^90.1-2013
South Carolina2009 IECC و 90.1-200790.1-2007
South Dakotaالحكم المحليلا يوجد قانون على مستوى الولاية
Tennessee2021 IECC and 90.1-201390.1-2007
Texas2015 IECC and 90.1-201390.1-2013
Utah2021 IECC and 90.1-2019^90.1-2019
Vermont2021 IECC and 90.1-2019^90.1-2019
Virginia2021 IECC and 90.1-2019^90.1-2019
Washington2018 Washington State Energy Code90.1-2019
Tennessee2012 IECC and 90.1-201090.1-2007
Texas2015 IECC and 90.1-201390.1-2013
Utah2021 IECC and 90.1-2019^90.1-2019
Vermont2018 IECC and 90.1-2016^90.1-2019
Virginia2021 IECC and 90.1-2019^90.1-2019
Washington2018 Washington State Energy Code90.1-2019
West Virginia90.1-201390.1-2013
Wisconsin2015 IECC and 90.1-2013^90.1-2010
Wyomingالحكم المحليلا يوجد قانون على مستوى الولاية
  • ^ When an amendment impacting energy efficiency can be quantified using DOE Prototype Building Models, they were captured in the analysis.
  • For states adopting both IECC and 90.1, the IECC code is usually analyzed as the state current code in this study except for states with extensive amendments to the IECC.

Sensor Solutions

Find out how Rayzeek can solve your energy saving challenges.

عرض جميع المنتجات

المفاهيم الأساسية لدليل تصميم ردهات الاستقبال

يتطلب تصميم حل فعال من حيث استهلاك الطاقة للتحكم في الإضاءة في ردهة الاستقبال التوزيع الاستراتيجي لمستشعرات الإشغال لضمان التغطية الشاملة للمساحة.

In a lobby, the primary areas that need to be covered by occupancy sensors are the entrance, the reception desk, and any seating or waiting areas. Here’s a possible design guide for a lobby:

  • Entrance Area: Install a ceiling occupancy sensor near the entrance. This sensor will detect the movement of people entering or exiting the lobby, ensuring the lights are activated when needed. Our ceiling sensors offer Auto ON and Full OFF functionality, providing automatic control of lighting based on occupancy.
  • Main Lobby Area: For larger lobbies, additional ceiling sensors may be required to cover the entire space. These sensors should be strategically placed to cover high-traffic areas, such as near the reception desk or waiting areas. The overlapping coverage of multiple sensors ensures there are no blind spots.
  • Reception Desk: Place a wall-mounted sensor near the reception desk. This sensor will detect the presence of the receptionist and any visitors at the desk, keeping the lights on in this area during occupied periods.
  • Seating/Waiting Areas: Install additional ceiling-mounted sensors in any seating or waiting areas. These sensors will detect when these areas are occupied and adjust the lighting accordingly.
  • Manual Control: Install a manual control near the entrance or reception desk. This allows for manual override of the lighting system when necessary.
  • Corridors Leading to Other Areas: Corridors leading to elevators, staircases, or other parts of the building should have their own wall or ceiling-mounted sensors. This ensures that lights in these areas are only activated when someone is passing through.

Wall Sensor Switches

RZ020/021 Motion Sensor Switches

  • 2-wire, 3-wire, 4-wires wiring options
  • Occupancy, Vacancy, Manual ON/OFF
  • Adjustive time delay and ambient light control

Multi-Location Wireless Wall Sensors

RZ020A/021A + RZ022W Kits

  • Hardwired RZ021A/022A occupancy sensor switch
  • Wireless companion switch (RZ022W) for multi-location control

Ceiling Occupancy Sensors

RZ036

  • Hardwired occupancy sensors
  • Auto ON, auto OFF
  • Line voltage and Low voltage available

Core features included:

  • Integrated manual ON/OFF control for all lighting
  • Vacancy sensors (Manual ON only): Lights must be turned on manually only
  • Adjustable time-delay, lighting is automatically turned full OFF after 15mins
  • Additional: multi-location wireless kits to expand the control range without re-wring
  • Additional: multiple wiring options available for both new constructions and retrofit projects.

Meets the Mandatory Provisions

IECC – 2011

C405.2.1 Occupant sensor controls

Occupant sensor controls shall be installed to control lights in the space.

C405.2.1.1 Occupant sensor control functions

  • Manual on or partial on to no more than 50% power.
  • Full off within 20 minutes after all occupants have left the space
  • A manual control to turn off the lights.

Full automatic-on controls with no manual control are permitted in lobbies where manual operation would endanger occupant safety or security.

ASHRAE 90.1 – 2022

9.4.1.1 a Local control

There shall be one or more manual lighting control device that provides ON and OFF control
of all lighting in the space.

9.4.1.1 g Automatic reduction control

The general lighting power in the space shall be automatically reduced by at least 50% within 15 minutes of all occupants leaving the space.

** NOTE: 9.4.1.1 g is required in all other lobbies except (Elevator, Hotel, Motion picture theater, Performing arts theater)

9.4.1.1 h Automatic full OFF control

All lighting in the space shall be automatically shut off within 15 minutes of all occupants leaving the space.

9.4.1.1 i Scheduled shutoff

All lighting in the space shall be automatically shut off during periods when the space is scheduled to be unoccupied.

** NOTE: At least one 9.4.1.1 h or 9.4.1.1 i shall be implemented.

Title 24 – 2022

130.1 (a) Manual area controls.

Each area enclosed by ceiling-height partitions shall provide lighting controls that allow the lighting in that area to be manually turned on and off.

130.1 (c) Shut-OFF Controls.

Lighting shall be controlled with occupant sensing controls to automatically shut OFF all of the lighting in 20 minutes or less after the control zone is unoccupied that shall function either as:

  • A. Occupant sensing controls (if 130.1(b) not required to have multi-level lighting controls); or
  • B. Partial-ON occupant sensing controls, or
  • C. Vacancy sensing controls, where all lighting responds to a manual ON input only

Let us hear you.

Let Rayzeek help design and deliver a bespoke energy-saving lighting solution for you.

    Arabic