Lobby
Oplev energibesparelsespotentialet i din lobby. Lær, hvordan du opfylder energibestemmelserne og reducerer energispild med vores skræddersyede løsninger.

Transform Your Lobby into an Energy-Efficient Space
The lobby is often the first point of contact for visitors and employees in a commercial building. It’s a space that needs to be well-lit and welcoming at all times. It’s a bustling area, filled with people coming and going at all hours. The lighting in these areas is typically high-intensity and left on for extended periods, leading to significant energy consumption.
Traditional lighting systems in lobbies are often manually controlled, resulting in lights being left on unnecessarily when the space is unoccupied, leading to high energy waste. Moreover, the diverse activities and varying occupancy levels in lobbies make it challenging to manage lighting efficiently. This not only increases operational costs but also contributes to a larger carbon footprint.
To address these issues, occupancy sensors offer an effective solution. These devices can automatically turn off or dim the lights when the lobby is vacant, significantly reducing energy consumption. Rayzeek’s range of occupancy sensors, including wall and ceiling-mounted options, provide a tailored solution for lobbies, ensuring efficient lighting control without compromising on comfort or safety.
Overhold energireglementerne

International Energy Conservation Code (IECC) er en modelstandard udviklet af International Code Council (ICC) med henblik på at fastsætte minimumskrav til projektering og udførelse for energieffektivitet i bygninger. IECC opdateres hvert tredje år for at integrere de nyeste praksisser og teknologier inden for energibesparelse.
IECC – Hvorfor det er vigtigt for dig
IECC er udbredt i delstater og kommuner over hele USA. IECC dækker forskellige aspekter af energiforbrug, herunder klimaskærmen (vægge, tag og vinduer), varme- og kølesystemer samt belysningsanlæg.
IECC stiller krav om specifikke belysningsstyringer, såsom tilstedeværelsessensorer, for at minimere energispild i ubrugte rum på tværs af forskellige områder.

ANSI/ASHRAE/IES Standard 90.1, Energy Standard for Sites and Buildings Except Low-Rise Residential Buildings, er en vidt anerkendt energistandard udgivet af American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).
ASHRAE 90.1 – Hvorfor det er vigtigt for dig
ASHRAE 90.1 anvendes som reference for bygningsreglementer i hele USA og fungerer som en overholdelsesmetode inden for IECC, der opstiller minimumskrav til energieffektive ydelser i erhvervsbygningers komponenter, herunder klimaskærme, HVAC-systemer, brugsvandssystemer og belysningsanlæg.
ASHRAE 90.1-standarden angiver maksimalt tilladte belysningseffekttætheder og minimumskrav til belysningsstyring, herunder brugen af tilstedeværelsessensorer i specifikke områder.

Title 24, del 6 af California Building Standards Code, officielt kendt som Building Energy Efficiency Standards for Residential and Nonresidential Buildings, Title 24 administreres af California Energy Commission og opdateres med jævne mellemrum for at afspejle nye teknologier og metoder inden for energieffektivitet.
Title 24 – Hvorfor det er vigtigt for dig
Title 24 er kendt for sine strenge krav, der ofte anses for at være mere vidtgående end kravene i mange andre energireglementer i USA. Title 24 opstiller strenge energiydelsesstandarder for alle aspekter af bygningskonstruktion, hvilket omfatter opvarmning, ventilation, aircondition (HVAC), brugsvand og belysning.
Title 24 kræver installation af tilstedeværelsessensorer, der tilpasser belysningen baseret på personers tilstedeværelse i specifikke områder af erhvervsbygninger for at sikre, at der ikke spildes energi.
Implementering af energireglementer efter delstat

Fold ud for at se den detaljerede tabel ↓
| Delstat | Gældende erhvervsbygningsreglement | Effektivitetskategori for erhvervsbygningsreglement |
|---|---|---|
| Alabama | 90.1-2013 | 90.1-2013 |
| Alaska | Ingen på delstatsniveau | Intet reglement på delstatsniveau |
| Arizona | Kommunalt selvstyre | <90.1-2007 |
| Arkansas | 2009 IECC og 90.1-2007 | 90.1-2007 |
| Californien | 2022 Building Energy Efficiency Standards | 90.1-2019 |
| Colorado | Kommunalt selvstyre | Intet reglement på delstatsniveau |
| Connecticut | 2021 IECC og 90.1-2019 | 90.1-2019 |
| Delaware | 2018 IECC og 90.1-2016 | 90.1-2013 |
| District of Columbia | 90.1-2013^ | 90.1-2019 |
| Florida | 2021 IECC og 90.1-2019^ | 90.1-2016 |
| Georgia | 2015 IECC og 90.1-2013^ | 90.1-2013 |
| Hawaii | Kommunalt selvstyre | 90.1-2013 |
| Idaho | 2018 IECC og 90.1-2016 | 90.1-2013 |
| Illinois | 2021 IECC og 90.1-2019 | 90.1-2019 |
| Indiana | 90.1-2007 | 90.1-2007 |
| Iowa | 2012 IECC og 90.1-2010 | 90.1-2007 |
| Kansas | Kommunalt selvstyre | Intet reglement på delstatsniveau |
| Kentucky | 2012 IECC og 90.1-2010 | 90.1-2007 |
| Louisiana | 2021 IECC og 90.1-2019^ | 90.1-2016 |
| Maine | 2015 IECC og 90.1-2013 | 90.1-2013 |
| Maryland | 2021 IECC og 90.1-2019^ | 90.1-2019 |
| Massachusetts | 2018 IECC og 90.1-2016^ | 90.1-2019 |
| Michigan | 2015 IECC og 90.1-2013^ | 90.1-2013 |
| Minnesota | 90.1-2019^ | 90.1-2019 |
| Mississippi | Ingen på delstatsniveau | Intet reglement på delstatsniveau |
| Missouri | Kommunalt selvstyre | Intet reglement på delstatsniveau |
| Montana | 2021 IECC og 90.1-2019 | 90.1-2019 |
| Nebraska | 2018 IECC og 90.1-2016 | 90.1-2013 |
| Nevada | 2018 IECC og 90.1-2016 | 90.1-2013 |
| New Hampshire | 2018 IECC og 90.1-2016^ | 90.1-2013 |
| New Jersey | 90.1-2019 | 90.1-2019 |
| New Mexico | 2021 IECC og 90.1-2019^ | 90.1-2019 |
| New York | 2018 IECC og 90.1-2016^ | 90.1-2016 |
| North Carolina | 2015 IECC og 90.1-2013^ | 90.1-2010 |
| North Dakota | Kommunalt selvstyre | Intet reglement på delstatsniveau |
| Ohio | 2021 IECC og 90.1-2019^ | 90.1-2016 |
| Oklahoma | 2006 IECC og 90.1-2004 | <90.1-2007 |
| Oregon | 90.1-2019 | 90.1-2019 |
| Pennsylvania | 2018 IECC og 90.1-2016 | 90.1-2013 |
| Rhode Island | 2018 IECC og 90.1-2016^ | 90.1-2013 |
| South Carolina | 2009 IECC og 90.1-2007 | 90.1-2007 |
| South Dakota | Kommunalt selvstyre | Intet reglement på delstatsniveau |
| Tennessee | 2021 IECC og 90.1-2013 | 90.1-2007 |
| Texas | 2015 IECC og 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC og 90.1-2019^ | 90.1-2019 |
| Vermont | 2021 IECC og 90.1-2019^ | 90.1-2019 |
| Virginia | 2021 IECC og 90.1-2019^ | 90.1-2019 |
| Washington | 2018 Washington State Energy Code | 90.1-2019 |
| Tennessee | 2012 IECC og 90.1-2010 | 90.1-2007 |
| Texas | 2015 IECC og 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC og 90.1-2019^ | 90.1-2019 |
| Vermont | 2018 IECC og 90.1-2016^ | 90.1-2019 |
| Virginia | 2021 IECC og 90.1-2019^ | 90.1-2019 |
| Washington | 2018 Washington State Energy Code | 90.1-2019 |
| West Virginia | 90.1-2013 | 90.1-2013 |
| Wisconsin | 2015 IECC og 90.1-2013^ | 90.1-2010 |
| Wyoming | Kommunalt selvstyre | Intet reglement på delstatsniveau |
- ^ When an amendment impacting energy efficiency can be quantified using DOE Prototype Building Models, they were captured in the analysis.
- For states adopting both IECC and 90.1, the IECC code is usually analyzed as the state current code in this study except for states with extensive amendments to the IECC.
Vigtige konceptudformningsprincipper for lobbyer
Projektering af en energieffektiv lysstyringsløsning til en lobby indebærer strategisk placering af tilstedeværelsessensorer for at sikre fuldstændig dækning af rummet.

In a lobby, the primary areas that need to be covered by occupancy sensors are the entrance, the reception desk, and any seating or waiting areas. Here’s a possible design guide for a lobby:
- Entrance Area: Install a ceiling occupancy sensor near the entrance. This sensor will detect the movement of people entering or exiting the lobby, ensuring the lights are activated when needed. Our ceiling sensors offer Auto ON and Full OFF functionality, providing automatic control of lighting based on occupancy.
- Main Lobby Area: For larger lobbies, additional ceiling sensors may be required to cover the entire space. These sensors should be strategically placed to cover high-traffic areas, such as near the reception desk or waiting areas. The overlapping coverage of multiple sensors ensures there are no blind spots.
- Reception Desk: Place a wall-mounted sensor near the reception desk. This sensor will detect the presence of the receptionist and any visitors at the desk, keeping the lights on in this area during occupied periods.
- Seating/Waiting Areas: Install additional ceiling-mounted sensors in any seating or waiting areas. These sensors will detect when these areas are occupied and adjust the lighting accordingly.
- Manual Control: Install a manual control near the entrance or reception desk. This allows for manual override of the lighting system when necessary.
- Corridors Leading to Other Areas: Corridors leading to elevators, staircases, or other parts of the building should have their own wall or ceiling-mounted sensors. This ensures that lights in these areas are only activated when someone is passing through.
Featured Products & Solutions
Core features included:
- Integrated manual ON/OFF control for all lighting
- Vacancy sensors (Manual ON only): Lights must be turned on manually only
- Adjustable time-delay, lighting is automatically turned full OFF after 15mins
- Additional: multi-location wireless kits to expand the control range without re-wring
- Additional: multiple wiring options available for both new constructions and retrofit projects.

Meets the Mandatory Provisions
IECC – 2011
C405.2.1 Occupant sensor controls
Occupant sensor controls shall be installed to control lights in the space.
C405.2.1.1 Occupant sensor control functions
- Manual on or partial on to no more than 50% power.
- Full off within 20 minutes after all occupants have left the space
- A manual control to turn off the lights.
Full automatic-on controls with no manual control are permitted in lobbies where manual operation would endanger occupant safety or security.
ASHRAE 90.1 – 2022
9.4.1.1 a Local control
There shall be one or more manual lighting control device that provides ON and OFF control
of all lighting in the space.
9.4.1.1 g Automatic reduction control
The general lighting power in the space shall be automatically reduced by at least 50% within 15 minutes of all occupants leaving the space.
** NOTE: 9.4.1.1 g is required in all other lobbies except (Elevator, Hotel, Motion picture theater, Performing arts theater)
9.4.1.1 h Automatic full OFF control
All lighting in the space shall be automatically shut off within 15 minutes of all occupants leaving the space.
9.4.1.1 i Scheduled shutoff
All lighting in the space shall be automatically shut off during periods when the space is scheduled to be unoccupied.
** NOTE: At least one 9.4.1.1 h or 9.4.1.1 i shall be implemented.
Title 24 – 2022
130.1 (a) Manual area controls.
Each area enclosed by ceiling-height partitions shall provide lighting controls that allow the lighting in that area to be manually turned on and off.
130.1 (c) Shut-OFF Controls.
Lighting shall be controlled with occupant sensing controls to automatically shut OFF all of the lighting in 20 minutes or less after the control zone is unoccupied that shall function either as:
- A. Occupant sensing controls (if 130.1(b) not required to have multi-level lighting controls); or
- B. Partial-ON occupant sensing controls, or
- C. Vacancy sensing controls, where all lighting responds to a manual ON input only
Let us hear you.