Conference Rooms
Discover the energy-saving potential of your conference room with Rayzeek’s occupancy sensor design guide.

Maximize Energy Efficiency in Conference Rooms with Occupancy Sensors
Conference rooms are integral to the functioning of any commercial building, serving as the hub for meetings, presentations, and brainstorming sessions. These rooms are often equipped with high-intensity lighting to ensure visibility during presentations and discussions. However, due to their intermittent usage, they are prone to high energy wastage. Lights are often left on when the room is vacant, leading to unnecessary energy consumption.
Moreover, the sporadic usage of conference rooms means that they often remain vacant for extended periods, leading to unnecessary energy consumption if the lights are left on. This wastage not only impacts the building’s energy efficiency but also contributes to higher operational costs.
With Rayzeek’s occupancy sensors, you can transform your conference room into an energy-efficient space, meeting the requirements of energy codes and contributing to a greener environment.
Splnění energetických předpisů

International Energy Conservation Code (IECC) je vzorový předpis vyvinutý organizací International Code Council (ICC) za účelem stanovení minimálních požadavků na návrh a konstrukci z hlediska energetické účinnosti budov. Předpis IECC je aktualizován každé tři roky, aby zohledňoval nejnovější postupy a technologie v oblasti úspory energie.
IECC a proč by vás měl zajímat
Předpis IECC je široce přijímán jednotlivými státy i samosprávami po celých Spojených státech. IECC pokrývá různé oblasti využití energie, včetně obálky budovy (stěny, střechy a okna), systémů vytápění a chlazení a osvětlovacích soustav.
Předpis IECC vyžaduje specifické prvky řízení osvětlení, jako jsou senzory přítomnosti, které minimalizují plytvání energií v neobsazených prostorech v různých oblastech.

Standard ANSI/ASHRAE/IES 90.1, Energy Standard for Sites and Buildings Except Low-Rise Residential Buildings, je široce uznávaný energetický standard vydávaný Americkou společností inženýrů pro vytápění, chlazení a klimatizaci (ASHRAE).
ASHRAE 90.1 a proč by vás měl zajímat
Standard ASHRAE 90.1 se používá jako srovnávací základna pro energetické předpisy budov po celých Spojených státech a slouží jako cesta k prokázání shody v rámci IECC. Definujeme minimální požadavky na energetickou účinnost prvků komerčních budov, včetně obálek budov, systémů HVAC, systémů ohřevu vody a osvětlovacích soustav.
Standard ASHRAE 90.1 stanovuje maximální povolenou hustotu příkonu osvětlení a minimální požadavky na řízení osvětlení, včetně použití senzorů přítomnosti v konkrétních prostorech.

Title 24, část 6 předpisu California Building Standards Code, oficiálně známá jako Building Energy Efficiency Standards for Residential and Nonresidential Buildings, je spravována orgánem California Energy Commission a pravidelně aktualizována s ohledem na nové technologie a metody energetické účinnosti.
Title 24 a proč by vás měl zajímat
Title 24 je známý svými přísnými požadavky, které jsou často považovány za náročnější než požadavky obsažené v mnoha jiných energetických předpisech napříč Spojenými státy. Title 24 vyžaduje přísné standardy energetické náročnosti pro všechny aspekty výstavby budov, což zahrnuje vytápění, větrání, klimatizaci (HVAC), ohřev vody a osvětlení.
Title 24 vyžaduje instalaci senzorů přítomnosti, které upravují osvětlení na základě obsazenosti místností v konkrétních prostorech komerčních budov, aby nedocházelo k plytvání energií.
Míra přijetí energetických předpisů podle států

Rozbalte pro zobrazení podrobné tabulky ↓
| Stát | Platný komerční předpis | Kategorie účinnosti komerčního předpisu |
|---|---|---|
| Alabama | 90.1-2013 | 90.1-2013 |
| Aljaška | Žádný celostátní | Žádný celostátní předpis |
| Arizona | Místní samospráva (Home rule) | <90.1-2007 |
| Arkansas | 2009 IECC a 90.1-2007 | 90.1-2007 |
| Kalifornie | Normy energetické účinnosti budov z roku 2022 | 90.1-2019 |
| Colorado | Místní samospráva (Home rule) | Žádný celostátní předpis |
| Connecticut | 2021 IECC a 90.1-2019 | 90.1-2019 |
| Delaware | 2018 IECC a 90.1-2016 | 90.1-2013 |
| District of Columbia | 90.1-2013^ | 90.1-2019 |
| Florida | 2021 IECC a 90.1-2019^ | 90.1-2016 |
| Georgia | 2015 IECC a 90.1-2013^ | 90.1-2013 |
| Havaj | Místní samospráva (Home rule) | 90.1-2013 |
| Idaho | 2018 IECC a 90.1-2016 | 90.1-2013 |
| Illinois | 2021 IECC a 90.1-2019 | 90.1-2019 |
| Indiana | 90.1-2007 | 90.1-2007 |
| Iowa | 2012 IECC and 90.1-2010 | 90.1-2007 |
| Kansas | Místní samospráva (Home rule) | Žádný celostátní předpis |
| Kentucky | 2012 IECC and 90.1-2010 | 90.1-2007 |
| Louisiana | 2021 IECC a 90.1-2019^ | 90.1-2016 |
| Maine | 2015 IECC and 90.1-2013 | 90.1-2013 |
| Maryland | 2021 IECC a 90.1-2019^ | 90.1-2019 |
| Massachusetts | 2018 IECC and 90.1-2016^ | 90.1-2019 |
| Michigan | 2015 IECC a 90.1-2013^ | 90.1-2013 |
| Minnesota | 90.1-2019^ | 90.1-2019 |
| Mississippi | Žádný celostátní | Žádný celostátní předpis |
| Missouri | Místní samospráva (Home rule) | Žádný celostátní předpis |
| Montana | 2021 IECC a 90.1-2019 | 90.1-2019 |
| Nebraska | 2018 IECC a 90.1-2016 | 90.1-2013 |
| Nevada | 2018 IECC a 90.1-2016 | 90.1-2013 |
| New Hampshire | 2018 IECC and 90.1-2016^ | 90.1-2013 |
| New Jersey | 90.1-2019 | 90.1-2019 |
| Nové Mexiko | 2021 IECC a 90.1-2019^ | 90.1-2019 |
| New York | 2018 IECC and 90.1-2016^ | 90.1-2016 |
| Severní Karolína | 2015 IECC a 90.1-2013^ | 90.1-2010 |
| Severní Dakota | Místní samospráva (Home rule) | Žádný celostátní předpis |
| Ohio | 2021 IECC a 90.1-2019^ | 90.1-2016 |
| Oklahoma | 2006 IECC a 90.1-2004 | <90.1-2007 |
| Oregon | 90.1-2019 | 90.1-2019 |
| Pensylvánie | 2018 IECC a 90.1-2016 | 90.1-2013 |
| Rhode Island | 2018 IECC and 90.1-2016^ | 90.1-2013 |
| Jižní Karolína | 2009 IECC a 90.1-2007 | 90.1-2007 |
| Jižní Dakota | Místní samospráva (Home rule) | Žádný celostátní předpis |
| Tennessee | 2021 IECC a 90.1-2013 | 90.1-2007 |
| Texas | 2015 IECC and 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC a 90.1-2019^ | 90.1-2019 |
| Vermont | 2021 IECC a 90.1-2019^ | 90.1-2019 |
| Virginie | 2021 IECC a 90.1-2019^ | 90.1-2019 |
| Washington | Energetický kodex státu Washington z roku 2018 | 90.1-2019 |
| Tennessee | 2012 IECC and 90.1-2010 | 90.1-2007 |
| Texas | 2015 IECC and 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC a 90.1-2019^ | 90.1-2019 |
| Vermont | 2018 IECC and 90.1-2016^ | 90.1-2019 |
| Virginie | 2021 IECC a 90.1-2019^ | 90.1-2019 |
| Washington | Energetický kodex státu Washington z roku 2018 | 90.1-2019 |
| Západní Virginie | 90.1-2013 | 90.1-2013 |
| Wisconsin | 2015 IECC a 90.1-2013^ | 90.1-2010 |
| Wyoming | Místní samospráva (Home rule) | Žádný celostátní předpis |
- ^ Pokud lze změnu s dopadem na energetickou účinnost kvantifikovat pomocí prototypových modelů budov DOE, byla do analýzy zahrnuta.
- U států přijímajících normy IECC i 90.1 je v této studii norma IECC obvykle analyzována jako aktuální státní kodex, s výjimkou států s rozsáhlými změnami normy IECC.
Design Guide Key Concepts for Conference Rooms
Designing an energy-efficient lighting control solution for conference rooms involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.

Designing an energy-efficient lighting system for a conference room involves strategic placement of occupancy sensors to ensure comprehensive coverage. Here are some guidelines to consider:
- Entrance Coverage: Install a wall-mounted sensor near the entrance to detect when someone enters or exits the room. This sensor should be positioned high enough to avoid obstruction from the open door and should not directly face the entrance to avoid false triggers from movement outside the room.
- Table Coverage: Place a ceiling-mounted sensor above the conference table to detect occupancy in the main area of the room. This sensor should be positioned centrally to ensure comprehensive coverage.
- Presentation Area Coverage: If your conference room has a dedicated presentation area, consider installing an additional wall-mounted sensor to cover this space. This sensor should be positioned to avoid any potential obstructions, such as screens or projectors.
- Wall Control: Install a wall control unit near the entrance for manual override or adjustments of the lighting settings. This control should be easily accessible upon entering or exiting the room.
- Avoidance of Obstructions and Interference: Ensure that sensors are not placed near air vents to prevent interference from air flow or vibrations. Also, consider the height and placement of furniture to avoid blocking the sensor’s field of view.
- Integration with Existing Systems: Our occupancy sensors can be integrated with existing lighting systems for seamless operation. They can also be programmed to turn off all lights after a certain period of inactivity, further enhancing energy efficiency.
Featured Products & Solutions
Core features included:
- Integrated manual ON/OFF control for all lighting
- Vacancy sensors (Manual ON only): Lights must be turned on manually only
- Adjustable time-delay, lighting is automatically turned full OFF after 15mins
- Additional: multi-location wireless kits to expand the control range without re-wring
- Additional: multiple wiring options available for both new constructions and retrofit projects.

Meets the Mandatory Provisions
IECC – 2011
C405.2.1 Occupant sensor controls
Occupant sensor controls shall be installed to control lights in the space.
C405.2.1.1 Occupant sensor control functions
- Manual on or partial on to no more than 50% power.
- Full off within 20 minutes after all occupants have left the space
- A manual control to turn off the lights.
ASHRAE 90.1 – 2022
9.4.1.1 a Local control
There shall be one or more manual lighting control device that provides ON and OFF control
of all lighting in the space.
9.4.1.1 b Restricted to manual ON
None of the lighting shall be automatically turned on
9.4.1.1 c Restricted to partial automatic ON
No more than 50% of the lighting power for the general lighting shall be allowed to be automatically turned on
** NOTE: At least one 9.4.1.1 b or 9.4.1.1 c shall be implemented.
9.4.1.1 h Automatic full OFF control
All lighting in the space shall be automatically shut off within 20 minutes of all occupants leaving the space
Title 24 – 2022
130.1 (a) Manual area controls.
Each area enclosed by ceiling-height partitions shall provide lighting controls that allow the lighting in that area to be manually turned on and off.
130.1 (c) Shut-OFF Controls.
Lighting shall be controlled with occupant sensing controls to automatically shut OFF all of the lighting in 20 minutes or less after the control zone is unoccupied that shall function either as:
- A. Occupant sensing controls (if 130.1(b) not required to have multi-level lighting controls); or
- B. Partial-ON occupant sensing controls, or
- C. Vacancy sensing controls, where all lighting responds to a manual ON input only