Maximize Energy Efficiency in Storage Rooms with Occupancy Sensors

Storage rooms, often overlooked, are integral parts of commercial buildings. These spaces are typically filled with shelves, boxes, and various items, and are used for storing supplies, equipment, or archived documents. Lighting in these areas is crucial for visibility and safety, but it can also be a significant source of energy waste. Traditional lighting systems in storage rooms are often left on unnecessarily, leading to high energy consumption and costs.

Moreover, storage rooms are usually equipped with fluorescent or LED lights, which, while energy-efficient, can still consume a considerable amount of power when left on for extended periods. The sporadic and unpredictable nature of storage room usage further exacerbates this issue, as lights are often left on even when the room is unoccupied, leading to unnecessary energy waste.

This energy wastage can be mitigated by using occupancy sensors. These devices automatically control lighting based on the presence or absence of people, ensuring lights are only on when needed. By installing occupancy sensors in storage rooms, businesses can significantly reduce their energy consumption, lower their utility bills, and contribute to a more sustainable environment.

Splnění energetických předpisů

International Energy Conservation Code (IECC) je vzorový předpis vyvinutý organizací International Code Council (ICC) za účelem stanovení minimálních požadavků na návrh a konstrukci z hlediska energetické účinnosti budov. Předpis IECC je aktualizován každé tři roky, aby zohledňoval nejnovější postupy a technologie v oblasti úspory energie.

IECC a proč by vás měl zajímat

Předpis IECC je široce přijímán jednotlivými státy i samosprávami po celých Spojených státech. IECC pokrývá různé oblasti využití energie, včetně obálky budovy (stěny, střechy a okna), systémů vytápění a chlazení a osvětlovacích soustav.

Předpis IECC vyžaduje specifické prvky řízení osvětlení, jako jsou senzory přítomnosti, které minimalizují plytvání energií v neobsazených prostorech v různých oblastech.

Standard ANSI/ASHRAE/IES 90.1, Energy Standard for Sites and Buildings Except Low-Rise Residential Buildings, je široce uznávaný energetický standard vydávaný Americkou společností inženýrů pro vytápění, chlazení a klimatizaci (ASHRAE).

ASHRAE 90.1 a proč by vás měl zajímat

Standard ASHRAE 90.1 se používá jako srovnávací základna pro energetické předpisy budov po celých Spojených státech a slouží jako cesta k prokázání shody v rámci IECC. Definujeme minimální požadavky na energetickou účinnost prvků komerčních budov, včetně obálek budov, systémů HVAC, systémů ohřevu vody a osvětlovacích soustav.

Standard ASHRAE 90.1 stanovuje maximální povolenou hustotu příkonu osvětlení a minimální požadavky na řízení osvětlení, včetně použití senzorů přítomnosti v konkrétních prostorech.

Title 24, část 6 předpisu California Building Standards Code, oficiálně známá jako Building Energy Efficiency Standards for Residential and Nonresidential Buildings, je spravována orgánem California Energy Commission a pravidelně aktualizována s ohledem na nové technologie a metody energetické účinnosti.

Title 24 a proč by vás měl zajímat

Title 24 je známý svými přísnými požadavky, které jsou často považovány za náročnější než požadavky obsažené v mnoha jiných energetických předpisech napříč Spojenými státy. Title 24 vyžaduje přísné standardy energetické náročnosti pro všechny aspekty výstavby budov, což zahrnuje vytápění, větrání, klimatizaci (HVAC), ohřev vody a osvětlení.

Title 24 vyžaduje instalaci senzorů přítomnosti, které upravují osvětlení na základě obsazenosti místností v konkrétních prostorech komerčních budov, aby nedocházelo k plytvání energií.

Míra přijetí energetických předpisů podle států

Rozbalte pro zobrazení podrobné tabulky ↓

StátPlatný komerční předpisKategorie účinnosti komerčního předpisu
Alabama90.1-201390.1-2013
AljaškaŽádný celostátníŽádný celostátní předpis
ArizonaMístní samospráva (Home rule)<90.1-2007
Arkansas2009 IECC a 90.1-200790.1-2007
KalifornieNormy energetické účinnosti budov z roku 202290.1-2019
ColoradoMístní samospráva (Home rule)Žádný celostátní předpis
Connecticut2021 IECC a 90.1-201990.1-2019
Delaware2018 IECC a 90.1-201690.1-2013
District of Columbia90.1-2013^90.1-2019
Florida2021 IECC a 90.1-2019^90.1-2016
Georgia2015 IECC a 90.1-2013^90.1-2013
HavajMístní samospráva (Home rule)90.1-2013
Idaho2018 IECC a 90.1-201690.1-2013
Illinois2021 IECC a 90.1-201990.1-2019
Indiana90.1-200790.1-2007
Iowa2012 IECC and 90.1-201090.1-2007
KansasMístní samospráva (Home rule)Žádný celostátní předpis
Kentucky2012 IECC and 90.1-201090.1-2007
Louisiana2021 IECC a 90.1-2019^90.1-2016
Maine2015 IECC and 90.1-201390.1-2013
Maryland2021 IECC a 90.1-2019^90.1-2019
Massachusetts2018 IECC and 90.1-2016^90.1-2019
Michigan2015 IECC a 90.1-2013^90.1-2013
Minnesota90.1-2019^90.1-2019
MississippiŽádný celostátníŽádný celostátní předpis
MissouriMístní samospráva (Home rule)Žádný celostátní předpis
Montana2021 IECC a 90.1-201990.1-2019
Nebraska2018 IECC a 90.1-201690.1-2013
Nevada2018 IECC a 90.1-201690.1-2013
New Hampshire2018 IECC and 90.1-2016^90.1-2013
New Jersey90.1-201990.1-2019
Nové Mexiko2021 IECC a 90.1-2019^90.1-2019
New York2018 IECC and 90.1-2016^90.1-2016
Severní Karolína2015 IECC a 90.1-2013^90.1-2010
Severní DakotaMístní samospráva (Home rule)Žádný celostátní předpis
Ohio2021 IECC a 90.1-2019^90.1-2016
Oklahoma2006 IECC a 90.1-2004<90.1-2007
Oregon90.1-201990.1-2019
Pensylvánie2018 IECC a 90.1-201690.1-2013
Rhode Island2018 IECC and 90.1-2016^90.1-2013
Jižní Karolína2009 IECC a 90.1-200790.1-2007
Jižní DakotaMístní samospráva (Home rule)Žádný celostátní předpis
Tennessee2021 IECC a 90.1-201390.1-2007
Texas2015 IECC and 90.1-201390.1-2013
Utah2021 IECC a 90.1-2019^90.1-2019
Vermont2021 IECC a 90.1-2019^90.1-2019
Virginie2021 IECC a 90.1-2019^90.1-2019
WashingtonEnergetický kodex státu Washington z roku 201890.1-2019
Tennessee2012 IECC and 90.1-201090.1-2007
Texas2015 IECC and 90.1-201390.1-2013
Utah2021 IECC a 90.1-2019^90.1-2019
Vermont2018 IECC and 90.1-2016^90.1-2019
Virginie2021 IECC a 90.1-2019^90.1-2019
WashingtonEnergetický kodex státu Washington z roku 201890.1-2019
Západní Virginie90.1-201390.1-2013
Wisconsin2015 IECC a 90.1-2013^90.1-2010
WyomingMístní samospráva (Home rule)Žádný celostátní předpis
  • ^ Pokud lze změnu s dopadem na energetickou účinnost kvantifikovat pomocí prototypových modelů budov DOE, byla do analýzy zahrnuta.
  • U států přijímajících normy IECC i 90.1 je v této studii norma IECC obvykle analyzována jako aktuální státní kodex, s výjimkou států s rozsáhlými změnami normy IECC.

Senzorová řešení

Zjistěte, jak může Rayzeek vyřešit vaše výzvy v oblasti úspory energie.

Zobrazit všechny nabídky

Klíčové koncepty návrhové příručky pro samostatné kanceláře

Návrh energeticky úsporného řešení řízení osvětlení pro samostatné kanceláře vyžaduje strategické umístění snímačů přítomnosti, které zajistí kompletní pokrytí daného prostoru.

In a storage room, the primary areas that require lighting are the main walkways and the individual aisles between shelves. Here are some guidelines to follow:

  • Main Walkways: Install ceiling occupancy sensors at regular intervals along the main walkways. These sensors should be set to Auto ON and Full OFF mode, ensuring that lights turn on automatically when someone enters the walkway and turn off when the area is vacant.
  • Individual Aisles: For individual aisles between shelves, consider installing wall occupancy sensors at the entrance of each aisle. These sensors can detect when someone enters the aisle and turn on the lights accordingly. Given the sporadic usage of these aisles, the sensors should be set to Manual ON and Full OFF mode. This means that the lights will only turn on when manually switched on but will turn off automatically when the aisle is vacant.
  • Entrance Area: The entrance area of the storage room should have a wall sensor switch that allows manual control of all lighting in the room. This switch can be used to turn all lights on or off as needed, providing an additional layer of control.
  • Sensor Placement Considerations: When placing sensors, ensure they are not located near air vents or other sources of movement that could trigger false positives. Also, ensure that the sensors’ field of view is not obstructed by shelves or stored items.
  • Sensor Height: Consider the height of the sensor installation. Sensors should be installed at a height that allows for optimal coverage of the room, taking into account the height of stored items.
  • Manual Control: Incorporate manual controls to allow users to turn ON/OFF all lighting when needed. This can be particularly useful in storage rooms where lighting may be required for extended periods during inventory checks or reorganization tasks.

Wall Sensor Switches

RZ020/021 Motion Sensor Switches

  • 2-wire, 3-wire, 4-wires wiring options
  • Occupancy, Vacancy, Manual ON/OFF
  • Adjustive time delay and ambient light control

Multi-Location Wireless Wall Sensors

RZ020A/021A + RZ022W Kits

  • Hardwired RZ021A/022A occupancy sensor switch
  • Wireless companion switch (RZ022W) for multi-location control

Ceiling Occupancy Sensors

RZ036

  • Hardwired occupancy sensors
  • Auto ON, auto OFF
  • Line voltage and Low voltage available

Core features included:

  • Integrated manual ON/OFF control for all lighting
  • Vacancy sensors (Manual ON only): Lights must be turned on manually only
  • Adjustable time-delay, lighting is automatically turned full OFF after 15mins
  • Additional: multi-location wireless kits to expand the control range without re-wring
  • Additional: multiple wiring options available for both new constructions and retrofit projects.

Meets the Mandatory Provisions

IECC – 2011

C405.2.1 Occupant sensor controls

Occupant sensor controls shall be installed to control lights in the space.

C405.2.1.1 Occupant sensor control functions

  • Manual on or partial on to no more than 50% power.
  • Full off within 20 minutes after all occupants have left the space
  • A manual control to turn off the lights.

ASHRAE 90.1 – 2022

9.4.1.1 a Local control

There shall be one or more manual lighting control device that provides ON and OFF control
of all lighting in the space.

9.4.1.1 H Automatic full OFF control

All lighting in the space shall be automatically shut off within 20 minutes of all occupants leaving the space

Additionally, for storage rooms with sizes <50 ft2:

9.4.1.1 b Restricted to manual ON

None of the lighting shall be automatically turned on

Title 24 – 2022

130.1 (a) Manual area controls.

Each area enclosed by ceiling-height partitions shall provide lighting controls that allow the lighting in that area to be manually turned on and off.

130.1 (c) Shut-OFF Controls.

Lighting shall be controlled with occupant sensing controls to automatically shut OFF all of the lighting in 20 minutes or less after the control zone is unoccupied that shall function either as:

  • A. Occupant sensing controls (if 130.1(b) not required to have multi-level lighting controls); or
  • B. Partial-ON occupant sensing controls, or
  • C. Vacancy sensing controls, where all lighting responds to a manual ON input only

Let us hear you.

Let Rayzeek help design and deliver a bespoke energy-saving lighting solution for you.

    Czech