Open offices, characterized by their large areas and cubicle partitions, are a common sight in many modern workplaces. These spaces are typically bustling with activity, filled with employees working, collaborating, and moving around. The expansive area requires ample illumination, often provided by high-intensity light fixtures. These lights, left on throughout the workday, consume a substantial amount of energy. Moreover, even when the office is vacant, during off-hours or lunch breaks, the lights often remain on, leading to unnecessary energy consumption.

The high energy consumption of lighting in open offices is a concern for both environmental and economic reasons. With the increasing emphasis on energy efficiency and sustainability, businesses are seeking ways to reduce their energy footprint. Moreover, energy costs can account for a significant portion of a company’s operating expenses, making energy-saving measures a smart financial decision as well.

To address this, the integration of occupancy sensors in open offices presents a compelling solution. Occupancy sensors can automatically control lighting based on the presence of individuals in the space, significantly reducing unnecessary energy consumption. When the office is vacant, the sensors can automatically switch off or dim the lights, thereby conserving energy. With our sensors seamlessly integrated into your open office layout, you can transform your open office into an energy-efficient workspace that meets the stringent requirements of US Energy Codes.

Enerji Kodlarıyla Uyum Sağlayın

Uluslararası Enerji Koruma Kodu (IECC), binalarda enerji verimliliği için asgari tasarım ve inşaat gerekliliklerini belirlemek üzere Uluslararası Kod Konseyi (ICC) tarafından geliştirilen bir model koddur. IECC, enerji koruma uygulamaları ve teknolojilerindeki en son gelişmeleri dahil etmek için her üç yılda bir güncellenir.

IECC, Neden Önemsemelisiniz?

IECC, Amerika Birleşik Devletleri genelinde eyaletler ve belediyeler tarafından yaygın olarak benimsenmektedir. IECC, bina kabuğu (duvarlar, çatılar ve pencereler), ısıtma ve soğutma sistemleri ile aydınlatma sistemleri dahil olmak üzere enerji kullanımının çeşitli yönlerini kapsar.

IECC, çeşitli alanlarda kullanılmayan mekanlardaki enerji israfını en aza indirmek için doluluk sensörleri gibi belirli aydınlatma kontrollerini zorunlu kılar.

ANSI/ASHRAE/IES Standard 90.1, Düşük Katlı Konut Dışındaki Siteler ve Binalar için Enerji Standardı, Amerikan Isıtma, Soğutma ve Klima Mühendisleri Derneği (ASHRAE) tarafından yayımlanan ve yaygın olarak tanınan bir enerji standardıdır.

ASHRAE 90.1, Neden Önemsemelisiniz?

ASHRAE 90.1, Amerika Birleşik Devletleri genelinde bina enerji kodları için bir kıyaslama ölçütü olarak kullanılır ve ticari binaların bileşenlerinin (bina kabukları, HVAC sistemleri, su ısıtma sistemleri ve aydınlatma sistemleri dahil) enerji verimli performansı için asgari gereklilikleri ana hatlarıyla belirleyen IECC içinde bir uyumluluk yolu olarak hizmet eder.

ASHRAE 90.1 standardı, belirli alanlarda doluluk sensörlerinin kullanımını da içeren asgari aydınlatma kontrol gerekliliklerini ve izin verilen maksimum aydınlatma güç yoğunluklarını belirtir.

California Yapı Standartları Kodu'nun 6. Bölümü, 24. Başlık, resmi olarak Konut ve Konut Dışı Binalar için Bina Enerji Verimliliği Standartları olarak bilinir. 24. Başlık, California Enerji Komisyonu tarafından yönetilir ve yeni enerji verimliliği teknolojilerini ve yöntemlerini yansıtacak şekilde periyodik olarak güncellenir.

Title 24, Neden Önemsemelisiniz?

Title 24, sıkı gereklilikleriyle bilinir ve genellikle Amerika Birleşik Devletleri'ndeki birçok diğer enerji kodundakinden daha katı olarak kabul edilir. Title 24, ısıtma, havalandırma, klima (HVAC), su ısıtma ve aydınlatma dahil olmak üzere bina inşaatının tüm yönleri için katı enerji performans standartlarını zorunlu kılar.

Title 24, enerji israfını önlemek için ticari binaların belirli alanlarında oda doluluk durumuna göre aydınlatmayı ayarlayan doluluk sensörlerinin kurulumunu gerektirir.

Eyaletlere Göre Enerji Kodu Kabulü

Ayrıntılı tabloyu görmek için genişletin ↓

EyaletMevcut Ticari KodTicari Kod Verimlilik Kategorisi
Alabama90.1-201390.1-2013
AlaskaEyalet genelinde yokEyalet genelinde kod yok
ArizonaYerel yönetim kuralı<90.1-2007
Arkansas2009 IECC ve 90.1-200790.1-2007
California2022 Bina Enerji Verimliliği Standartları90.1-2019
ColoradoYerel yönetim kuralıEyalet genelinde kod yok
Connecticut2021 IECC ve 90.1-201990.1-2019
Delaware2018 IECC ve 90.1-201690.1-2013
Columbia Bölgesi90.1-2013^90.1-2019
Florida2021 IECC ve 90.1-2019^90.1-2016
Georgia2015 IECC ve 90.1-2013^90.1-2013
HawaiiYerel yönetim kuralı90.1-2013
Idaho2018 IECC ve 90.1-201690.1-2013
Illinois2021 IECC ve 90.1-201990.1-2019
Indiana90.1-200790.1-2007
Iowa2012 IECC ve 90.1-201090.1-2007
KansasYerel yönetim kuralıEyalet genelinde kod yok
Kentucky2012 IECC ve 90.1-201090.1-2007
Louisiana2021 IECC ve 90.1-2019^90.1-2016
Maine2015 IECC ve 90.1-201390.1-2013
Maryland2021 IECC ve 90.1-2019^90.1-2019
Massachusetts2018 IECC ve 90.1-2016^90.1-2019
Michigan2015 IECC ve 90.1-2013^90.1-2013
Minnesota90.1-2019^90.1-2019
MississippiEyalet genelinde yokEyalet genelinde kod yok
MissouriYerel yönetim kuralıEyalet genelinde kod yok
Montana2021 IECC ve 90.1-201990.1-2019
Nebraska2018 IECC ve 90.1-201690.1-2013
Nevada2018 IECC ve 90.1-201690.1-2013
New Hampshire2018 IECC ve 90.1-2016^90.1-2013
New Jersey90.1-201990.1-2019
New Mexico2021 IECC ve 90.1-2019^90.1-2019
New York2018 IECC ve 90.1-2016^90.1-2016
North Carolina2015 IECC ve 90.1-2013^90.1-2010
North DakotaYerel yönetim kuralıEyalet genelinde kod yok
Ohio2021 IECC ve 90.1-2019^90.1-2016
Oklahoma2006 IECC ve 90.1-2004<90.1-2007
Oregon90.1-201990.1-2019
Pennsylvania2018 IECC ve 90.1-201690.1-2013
Rhode Island2018 IECC ve 90.1-2016^90.1-2013
South Carolina2009 IECC ve 90.1-200790.1-2007
South DakotaYerel yönetim kuralıEyalet genelinde kod yok
Tennessee2021 IECC ve 90.1-201390.1-2007
Texas2015 IECC ve 90.1-201390.1-2013
Utah2021 IECC ve 90.1-2019^90.1-2019
Vermont2021 IECC ve 90.1-2019^90.1-2019
Virginia2021 IECC ve 90.1-2019^90.1-2019
Washington2018 Washington Eyaleti Enerji Kodu90.1-2019
Tennessee2012 IECC ve 90.1-201090.1-2007
Texas2015 IECC ve 90.1-201390.1-2013
Utah2021 IECC ve 90.1-2019^90.1-2019
Vermont2018 IECC ve 90.1-2016^90.1-2019
Virginia2021 IECC ve 90.1-2019^90.1-2019
Washington2018 Washington Eyaleti Enerji Kodu90.1-2019
West Virginia90.1-201390.1-2013
Wisconsin2015 IECC ve 90.1-2013^90.1-2010
WyomingYerel yönetim kuralıEyalet genelinde kod yok
  • ^ Enerji verimliliğini etkileyen bir değişiklik, DOE Prototip Bina Modelleri kullanılarak nicelendirilebildiğinde, analizde yer almıştır.
  • Hem IECC'yi hem de 90.1'i benimseyen eyaletler için, bu çalışmada IECC kodu genellikle eyaletin geçerli kodu olarak analiz edilir; IECC'ye kapsamlı değişiklikler yapan eyaletler hariç.

Sensör Çözümleri

Rayzeek'in enerji tasarrufu zorluklarınızı nasıl çözebileceğini öğrenin.

Tüm Teklifleri Görüntüle

Design Guide Key Concepts for Open Offices

Designing an energy-efficient lighting control solution for open offices involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.

In an open office setting, the primary areas to consider for sensor placement are the main walkways and areas with high foot traffic. These areas are crucial for sensor placement as they are the main areas of human traffic:

  • Cover Main Walkways: The main walkways in an open office are the areas with the highest foot traffic. Therefore, these should be the primary focus when placing sensors. Ceiling-mounted sensors are ideal for these areas as they provide a wide coverage area and are strategically placed to cover the entire length.
  • Overlap Coverage on Walkways: To avoid blind spots, ensure that the coverage patterns of the sensors overlap along the walkways. This ensures continuous detection as people move through the space, preventing any gaps in sensor coverage.
  • Use a Long Timeout: Given the size and activity level in open offices, use a longer timeout setting (15 or 20 minutes) on the sensors. This prevents the lights from turning off too soon when there’s no movement detected for a brief period.
  • Consider Wall-Mounted Sensors: If the cubicle walls are short, consider using wall-mounted sensors in addition to ceiling-mounted ones. These can provide additional coverage and ensure that all areas of the office are monitored.
  • Avoid Air Vents: Don’t place sensors near air vents. The vibration and airflow can reduce the effectiveness of the sensors. PIR sensors should not be within 4ft of an air vent, and ultrasonic sensors should not be within 6ft of an air vent.
  • Manuel Kontrol: Incorporate manual controls that are integrated with the occupancy sensors. This allows for manual override to turn ON/OFF all lighting when necessary.

Duvar Sensör Anahtarları

RZ020/021 Hareket Sensör Anahtarları

  • 2 telli, 3 telli, 4 telli kablolama seçenekleri
  • Doluluk, Boşaltma, Manuel AÇMA/KAPAMA
  • Ayarlanabilir zaman gecikmesi ve ortam ışığı kontrolü

Çoklu Konumlu Kablosuz Duvar Sensörleri

RZ020A/021A + RZ022W Kitleri

  • Kablolu RZ021A/022A doluluk sensör anahtarı
  • Çoklu konum kontrolü için kablosuz refakatçi anahtar (RZ022W)

Tavan Doluluk Sensörleri

RZ036

  • Kablolu doluluk sensörleri
  • Otomatik AÇMA, otomatik KAPAMA
  • Hat voltajı ve Düşük voltaj seçenekleri mevcut

Temel özellikler şunları içerir:

  • Tüm aydınlatma için entegre manuel AÇMA/KAPAMA kontrolü
  • Boşaltma sensörleri (Yalnızca Manuel AÇMA): Işıklar yalnızca manuel olarak açılmalıdır
  • Ayarlanabilir zaman gecikmesi, aydınlatma 15 dakika sonra otomatik olarak tamamen KAPANIR
  • Ek olarak: Yeniden kablolama yapmadan kontrol alanını genişletmek için çoklu konumlu kablosuz kitler
  • Ek olarak: Hem yeni inşaat hem de renovasyon projeleri için birden fazla kablolama seçeneği mevcuttur.

Zorunlu Hükümleri Karşılar

IECC – 2011

C405.2.1 Kullanıcı sensör kontrolleri

Alandaki ışıkları kontrol etmek için kullanıcı sensör kontrolleri kurulmalıdır.

For open offices < 300 sq. ft:

C405.2.1.1 Kullanıcı sensör kontrol işlevleri

  • Manuel açma veya % gücüne kadar kısmi açma.
  • Tüm kullanıcılar alanı terk ettikten sonra 20 dakika içinde tamamen kapanma
  • Işıkları kapatmak için bir manuel kontrol.

For open offices > 300 sq. ft:

  • The general lighting shall be controlled separately in control zones with floor areas not greater than 600 sq. ft within the open plan office space.
  • In each control zone, the general lighting shall be permitted to automatically turn on within the control zone. In other unoccupied zones, the general lighting shall be permitted to turn on to < 20% full power(or unaffected).
  • Automatically turn off general lighting in all control zones within 20 minutes after all occupants have left the space.
  • In each control zone, the general lighting shall turn off or uniformly reduce lighting power to an unoccupied setpoint of < 20% full power within 20 minutes after all occupants have left.

ASHRAE 90.1 – 2022

For open offices in any sizes:

9.4.1.1 a Local control

There shall be one or more manual lighting control device that provides ON and OFF control
of all lighting in the space.

9.4.1.1 b Restricted to manual ON

None of the lighting shall be automatically turned on

9.4.1.1 c Restricted to partial automatic ON

No more than 50% of the lighting power for the general lighting shall be allowed to be automatically turned on

** NOTE: At least one 9.4.1.1 b or 9.4.1.1 c shall be implemented.

9.4.1.1 H Otomatik tam KAPAMA kontrolü

Alandaki tüm aydınlatma, tüm kullanıcılar alanı terk ettikten sonra 20 dakika içinde otomatik olarak kapatılmalıdır

Additionally, for open offices > 300 sq. ft:

9.4.1.1 g Automatic reduction control

The general lighting power in the space shall be automatically reduced by at least 50% within 15 minutes of all occupants leaving the space.

Title 24 – 2022

For open offices in any sizes:

130.1 (a) Manuel alan kontrolleri.

Tavan yüksekliğindeki bölmelerle çevrelenen her alan, o alandaki aydınlatmanın manuel olarak açılıp kapatılmasına olanak tanıyan aydınlatma kontrolleri sağlamalıdır.

130.1 (c) KAPAMA Kontrolleri.

Additionally, for open offices <250 sq. ft:

130.1 (c) 5. Occupant sensing controls are required for specified offices.

Aydınlatma, kontrol alanı boşaldıktan sonra 20 dakika veya daha kısa sürede tüm aydınlatmayı otomatik olarak KAPATMAK için kullanıcı algılama kontrolleriyle kontrol edilmelidir. Bu kontroller şu işlevlerden birini yerine getirmelidir:

  • A. Kullanıcı algılama kontrolleri (eğer 130.1(b) çok seviyeli aydınlatma kontrolleri gerektirmiyorsa); veya
  • B. Kısmi AÇMA kullanıcı algılama kontrolleri, veya
  • C. Boşluk algılama kontrolleri, tüm aydınlatmanın yalnızca manuel AÇIK girişine yanıt verdiği yer

Additionally, for open offices > 250 sq. ft:

130.1 (c) 6. Full or partial-OFF occupant sensing controls are required for offices greater than 250 square feet.

In office spaces greater than 250 square feet, general lighting shall be controlled with occupant sensing controls that meet all of the following:

  • Lighting shall be controlled separately in control zones not greater than 600 square feet. For luminaires with an embedded occupant sensor that are capable of reducing power independently from other luminaires, each luminaire can be considered its own control zone
  • The occupant sensing controls shall uniformly reduce lighting power in the control zone by at least 80% full power(or off) in 20 minutes or less after the control zone is unoccupied.
  • The occupant sensing controls shall automatically turn off lighting in ALL control zones in 20 minutes or less after the entire office space is unoccupied
  • When occupancy is detected:
    • in each control zone, lighting shall be allowed to automatically turn on to any level up to full power.
    • in other control zones that are unoccupied, lighting shall operate at no more than 20% full power.