storage rooms
Discover the energy-saving potential of storage rooms with Rayzeek’s occupancy sensor design guide.

Maximize Energy Efficiency in Storage Rooms with Occupancy Sensors
Storage rooms, often overlooked, are integral parts of commercial buildings. These spaces are typically filled with shelves, boxes, and various items, and are used for storing supplies, equipment, or archived documents. Lighting in these areas is crucial for visibility and safety, but it can also be a significant source of energy waste. Traditional lighting systems in storage rooms are often left on unnecessarily, leading to high energy consumption and costs.
Moreover, storage rooms are usually equipped with fluorescent or LED lights, which, while energy-efficient, can still consume a considerable amount of power when left on for extended periods. The sporadic and unpredictable nature of storage room usage further exacerbates this issue, as lights are often left on even when the room is unoccupied, leading to unnecessary energy waste.
This energy wastage can be mitigated by using occupancy sensors. These devices automatically control lighting based on the presence or absence of people, ensuring lights are only on when needed. By installing occupancy sensors in storage rooms, businesses can significantly reduce their energy consumption, lower their utility bills, and contribute to a more sustainable environment.
Соответствие энергетическим стандартам

Международный код по энергосбережению (IECC) представляет собой типовой свод правил, разработанный Международным советом по строительным нормам и правилам (ICC) для установления минимальных требований к проектированию и строительству с точки зрения энергоэффективности зданий. IECC обновляется каждые три года, чтобы включать новейшие практики и технологии в области энергосбережения.
Почему IECC важен для вас
IECC широко применяется штатами и муниципалитетами по всей территории США. IECC охватывает различные аспекты энергопотребления, включая ограждающие конструкции здания (стены, крыши и окна), системы отопления и охлаждения, а также системы освещения.
IECC предписывает обязательное использование специальных средств управления освещением, таких как датчики присутствия, чтобы минимизировать потерю энергии в незанятых помещениях различных зон.

Стандарт ANSI/ASHRAE/IES 90.1 «Стандарт энергоэффективности зданий и сооружений, за исключением малоэтажных жилых зданий» — это широко признанный стандарт энергоэффективности, публикуемый Американским обществом инженеров по отоплению, охлаждению и кондиционированию воздуха (ASHRAE).
Почему ASHRAE 90.1 важен для вас
ASHRAE 90.1 используется в качестве ориентира для энергетических строительных норм по всей территории США и служит вариантом подтверждения соответствия в рамках IECC, определяя минимальные требования к энергоэффективности компонентов коммерческих зданий, включая ограждающие конструкции, системы HVAC, системы горячего водоснабжения и системы освещения.
Стандарт ASHRAE 90.1 устанавливает максимально допустимую удельную мощность освещения и минимальные требования к управлению освещением, включая использование датчиков присутствия в определенных зонах.

Раздел 24, часть 6 Строительных стандартов штата Калифорния, официально известный как «Стандарты энергоэффективности жилых и нежилых зданий» (Title 24), находится в ведении Энергетической комиссии штата Калифорния и периодически обновляется с учетом новых технологий и методов энергоэффективности.
Почему Title 24 важен для вас
Стандарт Title 24 известен своими строгими требованиями, которые часто считаются более жесткими, чем нормы других энергетических сводов правил в США. Title 24 устанавливает строгие стандарты энергоэффективности для всех аспектов строительства зданий, включая отопление, вентиляцию, кондиционирование воздуха (HVAC), горячее водоснабжение и освещение.
Title 24 требует установки датчиков присутствия, регулирующих освещение в зависимости от наличия людей в определенных помещениях коммерческих зданий, что предотвращает нерациональный расход энергии.
Применение энергетических стандартов по штатам

Разверните, чтобы просмотреть подробную таблицу ↓
| Штат | Действующий коммерческий строительный код | Категория эффективности коммерческого строительного кода |
|---|---|---|
| Алабама | 90.1-2013 | 90.1-2013 |
| Аляска | Отсутствует на уровне штата | Нет единого строительного кода на уровне штата |
| Аризона | Местное самоуправление | <90.1-2007 |
| Арканзас | 2009 IECC и 90.1-2007 | 90.1-2007 |
| Калифорния | 2022 Стандарты энергоэффективности зданий | 90.1-2019 |
| Колорадо | Местное самоуправление | Нет единого строительного кода на уровне штата |
| Коннектикут | 2021 IECC и 90.1-2019 | 90.1-2019 |
| Делавэр | 2018 IECC и 90.1-2016 | 90.1-2013 |
| Округ Колумбия | 90.1-2013^ | 90.1-2019 |
| Флорида | 2021 IECC и 90.1-2019^ | 90.1-2016 |
| Джорджия | 2015 IECC и 90.1-2013^ | 90.1-2013 |
| Гавайи | Местное самоуправление | 90.1-2013 |
| Айдахо | 2018 IECC и 90.1-2016 | 90.1-2013 |
| Иллинойс | 2021 IECC и 90.1-2019 | 90.1-2019 |
| Индиана | 90.1-2007 | 90.1-2007 |
| Айова | 2012 IECC и 90.1-2010 | 90.1-2007 |
| Канзас | Местное самоуправление | Нет единого строительного кода на уровне штата |
| Кентукки | 2012 IECC и 90.1-2010 | 90.1-2007 |
| Луизиана | 2021 IECC и 90.1-2019^ | 90.1-2016 |
| Мэн | 2015 IECC и 90.1-2013 | 90.1-2013 |
| Мэриленд | 2021 IECC и 90.1-2019^ | 90.1-2019 |
| Массачусетс | 2018 IECC и 90.1-2016^ | 90.1-2019 |
| Мичиган | 2015 IECC и 90.1-2013^ | 90.1-2013 |
| Миннесота | 90.1-2019^ | 90.1-2019 |
| Миссисипи | Отсутствует на уровне штата | Нет единого строительного кода на уровне штата |
| Миссури | Местное самоуправление | Нет единого строительного кода на уровне штата |
| Монтана | 2021 IECC и 90.1-2019 | 90.1-2019 |
| Небраска | 2018 IECC и 90.1-2016 | 90.1-2013 |
| Невада | 2018 IECC и 90.1-2016 | 90.1-2013 |
| Нью-Гэмпшир | 2018 IECC и 90.1-2016^ | 90.1-2013 |
| Нью-Джерси | 90.1-2019 | 90.1-2019 |
| Нью-Мексико | 2021 IECC и 90.1-2019^ | 90.1-2019 |
| Нью-Йорк | 2018 IECC и 90.1-2016^ | 90.1-2016 |
| Северная Каролина | 2015 IECC и 90.1-2013^ | 90.1-2010 |
| Северная Дакота | Местное самоуправление | Нет единого строительного кода на уровне штата |
| Огайо | 2021 IECC и 90.1-2019^ | 90.1-2016 |
| Оклахома | 2006 IECC и 90.1-2004 | <90.1-2007 |
| Орегон | 90.1-2019 | 90.1-2019 |
| Пенсильвания | 2018 IECC и 90.1-2016 | 90.1-2013 |
| Род-Айленд | 2018 IECC и 90.1-2016^ | 90.1-2013 |
| Южная Каролина | 2009 IECC и 90.1-2007 | 90.1-2007 |
| Южная Дакота | Местное самоуправление | Нет единого строительного кода на уровне штата |
| Теннесси | 2021 IECC и 90.1-2013 | 90.1-2007 |
| Техас | 2015 IECC и 90.1-2013 | 90.1-2013 |
| Юта | 2021 IECC и 90.1-2019^ | 90.1-2019 |
| Вермонт | 2021 IECC и 90.1-2019^ | 90.1-2019 |
| Виргиния | 2021 IECC и 90.1-2019^ | 90.1-2019 |
| Вашингтон | Энергетический кодекс штата Вашингтон 2018 года | 90.1-2019 |
| Теннесси | 2012 IECC и 90.1-2010 | 90.1-2007 |
| Техас | 2015 IECC и 90.1-2013 | 90.1-2013 |
| Юта | 2021 IECC и 90.1-2019^ | 90.1-2019 |
| Вермонт | 2018 IECC и 90.1-2016^ | 90.1-2019 |
| Виргиния | 2021 IECC и 90.1-2019^ | 90.1-2019 |
| Вашингтон | Энергетический кодекс штата Вашингтон 2018 года | 90.1-2019 |
| Западная Виргиния | 90.1-2013 | 90.1-2013 |
| Висконсин | 2015 IECC и 90.1-2013^ | 90.1-2010 |
| Вайоминг | Местное самоуправление | Нет единого строительного кода на уровне штата |
- ^ Если поправка, влияющая на энергоэффективность, могла быть количественно оценена с использованием типовых моделей зданий Министерства энергетики США (DOE), она учитывалась в анализе.
- Для штатов, принимающих как IECC, так и 90.1, кодекс IECC обычно анализируется в данном исследовании как действующий кодекс штата, за исключением штатов с обширными поправками к IECC.
Основные концепции руководства по проектированию освещения для отдельных кабинетов
Проектирование энергоэффективного решения по управлению освещением для отдельных кабинетов требует стратегического размещения датчиков присутствия для обеспечения полного охвата помещения.

In a storage room, the primary areas that require lighting are the main walkways and the individual aisles between shelves. Here are some guidelines to follow:
- Main Walkways: Install ceiling occupancy sensors at regular intervals along the main walkways. These sensors should be set to Auto ON and Full OFF mode, ensuring that lights turn on automatically when someone enters the walkway and turn off when the area is vacant.
- Individual Aisles: For individual aisles between shelves, consider installing wall occupancy sensors at the entrance of each aisle. These sensors can detect when someone enters the aisle and turn on the lights accordingly. Given the sporadic usage of these aisles, the sensors should be set to Manual ON and Full OFF mode. This means that the lights will only turn on when manually switched on but will turn off automatically when the aisle is vacant.
- Entrance Area: The entrance area of the storage room should have a wall sensor switch that allows manual control of all lighting in the room. This switch can be used to turn all lights on or off as needed, providing an additional layer of control.
- Факторы, учитываемые при размещении датчиков: When placing sensors, ensure they are not located near air vents or other sources of movement that could trigger false positives. Also, ensure that the sensors’ field of view is not obstructed by shelves or stored items.
- Sensor Height: Consider the height of the sensor installation. Sensors should be installed at a height that allows for optimal coverage of the room, taking into account the height of stored items.
- Manual Control: Incorporate manual controls to allow users to turn ON/OFF all lighting when needed. This can be particularly useful in storage rooms where lighting may be required for extended periods during inventory checks or reorganization tasks.
Рекомендуемые продукты и решения
Основные функции:
- Встроенное ручное управление включением/выключением для всего освещения
- Датчики отсутствия (только ручное включение): свет необходимо включать только вручную
- Регулируемая задержка времени, освещение автоматически полностью выключается через 15 минут
- Дополнительно: многоточечные беспроводные комплекты для расширения зоны управления без прокладки новой проводки
- Дополнительно: несколько вариантов подключения как для нового строительства, так и для проектов модернизации.

Соответствует обязательным требованиям
IECC – 2011
C405.2.1 Элементы управления датчиков присутствия
Для управления освещением в помещении должны быть установлены элементы управления датчиков присутствия.
C405.2.1.1 Функции элементов управления датчиков присутствия
- Ручное включение или частичное включение не более чем на 50% мощности.
- Полное выключение в течение 20 минут после того, как все люди покинут помещение
- Ручной орган управления для выключения света.
ASHRAE 90.1 – 2022
9.4.1.1 a Локальное управление
Должно быть предусмотрено одно или несколько устройств ручного управления освещением, обеспечивающих включение (ON) и выключение (OFF)
всего освещения в помещении.
9.4.1.1 H Automatic full OFF control
All lighting in the space shall be automatically shut off within 20 minutes of all occupants leaving the space
Additionally, for storage rooms with sizes <50 ft2:
9.4.1.1 b Ограничение только ручным включением (ON)
Никакая часть освещения не должна включаться автоматически
Title 24 – 2022
130.1 (a) Manual area controls.
Each area enclosed by ceiling-height partitions shall provide lighting controls that allow the lighting in that area to be manually turned on and off.
130.1 (c) Shut-OFF Controls.
Lighting shall be controlled with occupant sensing controls to automatically shut OFF all of the lighting in 20 minutes or less after the control zone is unoccupied that shall function either as:
- A. Occupant sensing controls (if 130.1(b) not required to have multi-level lighting controls); or
- B. Partial-ON occupant sensing controls, or
- C. Vacancy sensing controls, where all lighting responds to a manual ON input only
Let us hear you.
Let Rayzeek help design and deliver a bespoke energy-saving lighting solution for you.