Senzor de mișcare și prezență la tensiunea rețelei, cu montaj pe tavan (RZ037-10A)

RZ037-10A

$17.00

RZ037-10A is a line voltage passive infrared (PIR) ceiling-mount occupancy sensor for automatic lighting and fan control in residential and commercial spaces.

The RZ037-10A connects directly to line voltage and mounts to the ceiling (neutral required). It offers 360° coverage with an 8–12 m detection diameter, a robust 10A load rating for multiple fixtures, push-button setup for time delay, Lux, and sensitivity, and a 1-minute warm-up on power-up for stable operation.

Caracteristici principale:

  • Mod de prezență Auto-ON/Auto-OFF (cu posibilitate de ignorare prin senzorul Lux)
  • Acoperire de 360 de grade; diametru de detecție de 8–12 m
  • 100V ~ 265V AC line voltage, 10A rating
  • Reglare prin butoane: temporizare, nivel Lux, sensibilitate
  • Necesită fir de nul; cablare cu 3 fire (L, N, sarcină)
Citește mai mult

Caracteristici principale

  • Line voltage 100–265V AC, 10A rating (neutral required)
  • Senzor PIR cu montare pe plafon, acoperire de 360° și diametru de detecție de 8–12 m
  • Configurare prin butoane: Timp, Lux, Sensibilitate

Livrare rapidă: 99% în stoc

Gamă completă de produse activate de mișcare

Solicitați informații pentru comenzi ODM/OEM en gros

Senzor de prezență pentru montare pe plafon

The RZ037-10A is a ceiling-mounted 360-degree PIR motion sensor switch for dependable lighting control. Using advanced passive infrared (PIR) and microcontroller technology, it delivers stable detection and easy configuration to help reduce energy use.

With a 10A rating, it supports heavier residential and commercial lighting loads and multiple fixtures.

Reglaje simple

Tool-free push-button setup under the top cover. Configure:

  • Temporizarea: de la 15 s la 30 min
  • Nivelul senzorului de lumină: OFF, 15, 25 (implicit), 35 Lux
  • Sensibilitatea: Ridicată sau Scăzută

Note: After first power-up or power restoration, a 1-minute warm-up occurs during which the load is not controlled.

Caracteristici, avantaje, specificații

The RZ037-10A ceiling occupancy sensor provides wide 360° coverage with adjustable time delay, sensitivity, and ambient light threshold. It connects directly to line voltage and is suitable for residential and commercial applications.

Caracteristici și avantaje

  • PIR with microcontroller for stable, accurate detection
  • Adjustable time delay, Lux level, and sensitivity
  • 360° ceiling coverage with 8–12 m detection diameter
  • Neutral wire required
  • 100–265 VAC wide voltage input
Caracteristici

Sensor Mode

Occupancy mode; occupancy without light sensor (Lux OFF)

Temporizare

15 s, 30 s, 1 min (default), 3 min, 5 min, 10 min, 30 min

Senzor de lumină

Off, 15 Lux, 25 Lux (default), 35 Lux

Sensor Sensitivity

Low Sensitivity, High Sensitivity

Power-Up

1-minute warm-up (no load control during warm-up)

Working Conditions

Power Source

100 VAC ~ 265 VAC

Power Frequency

50 / 60 Hz

Installation Height

2.5 m ~ 3.5 m

Umiditate de funcționare

< 93% RH

Working Temperature

-10 ~ +40℃

Detection Capability

Detection Diameter

8 m ~ 12 m (<27℃)

Rază de detecție

360°

Detection Speed

0.6 ~ 1.5 m/s

Load Compatibility (RZ037-10A)

Fluorescent / Ballast / LED

500 W / 110 VAC; 1000 W / 220 VAC

Incandescent / Halogen

1000 W / 110 VAC; 2200 W / 220 VAC

Versatile Applications

The RZ037 is the ideal ceiling-mounted occupancy sensor solution for 100V ~265V home applications and commercial projects. Perfect for frequently visited spaces, such as public bathrooms, hallways, garages, open offices, breakrooms, stairwells, or corridors.

Bathroom

Occupancy sensor with light sensor enabled is the ideal mode for bathroom usage, especially when you need to use it at night. Manual ON mode can be suitable for long showers.

Garage

Walk in and out of your home garage without the need to reach the light switch with an occupancy sensor switch. Enable daylight sensing to save more energy in the daytime.

Laundry Room

Enjoy the automatic lighting turned on and off for you when arm-full with piles of laundry to wash or clean clothes to take away.

Kitchen

Place an occupancy sensor switch at the entrance and enjoy the automatic lighting while you’re busy cooking and preparing food for your family.

Hallway

Occupancy/vacancy sensor switches can reduce the hours of lighting used by approximately 53% on dark hallways in your basement.

Breakroom

Occupancy sensors can reduce energy waste by 39% and increase energy-saving up to 17% with a 20-minute time delay for breakrooms.

Birou individual

Rayzeek motion sensor switches provide max flexibility for office use cases. Occurpnay, vacancy or manual mode, your office, your call.

Sală de ședințe

Vacancy switch with manual override feature is perfect for conference rooms where it’s not frequently used and requires manual turn on and off for presentations.

Videoclipuri

RZ037 User Guide

Fire Resistance Testing – RZ036

Load Testing

Resurse

rz021 occupancy vacanccy sensor switch residential appliction

Extindeți gama de senzori de mișcare

Vizualizați toate produsele noastre cu senzori de mișcare pentru economisirea energiei

Recenzii

Nu există recenzii până acum.

Fii primul care scrii o recenzie pentru „Ceiling Mount Line Voltage Occupancy Motion Sensor (RZ037-10A)”

S-ar putea să-ți placă și…

Romanian