Product video
Sufitowy czujnik ruchu i obecności o napięciu sieciowym (RZ037-10A)
RZ037-10A
$17.00
RZ037-10A is a line voltage passive infrared (PIR) ceiling-mount occupancy sensor for automatic lighting and fan control in residential and commercial spaces.
Main Features:
- Auto-ON/Auto-OFF occupancy mode (Lux override available)
- 360-degree coverage; 8–12 m detection diameter
- 100V ~ 265V AC line voltage, 10A rating
- Push-button adjustment: time delay, Lux, sensitivity
- Neutral wire required; 3-wire (L, N, Load) wiring
Główne cechy produktu
- Line voltage 100–265V AC, 10A rating (neutral required)
- 360° ceiling-mount PIR with 8–12 m detection diameter
- Push-button setup: Time, Lux, Sensitivity
Nie tego szukasz? Zobacz nasze portfolio:
Skonsultuj się z ekspertem
Szybka dostawa: 99% w magazynie
Pełna linia produktów aktywowanych ruchem
Wyślij zapytanie dla hurtowych zamówień ODM/OEM

Ceiling Mount Occupancy Sensor
The RZ037-10A is a ceiling-mounted 360-degree PIR motion sensor switch for dependable lighting control. Using advanced passive infrared (PIR) and microcontroller technology, it delivers stable detection and easy configuration to help reduce energy use.
With a 10A rating, it supports heavier residential and commercial lighting loads and multiple fixtures.

Easy Adjustments
Tool-free push-button setup under the top cover. Configure:
- Time delay: 15s to 30min
- Light sensor level: OFF, 15, 25 (default), 35 Lux
- Sensitivity: High or Low
Note: After first power-up or power restoration, a 1-minute warm-up occurs during which the load is not controlled.
Funkcje, zalety, specyfikacja
The RZ037-10A ceiling occupancy sensor provides wide 360° coverage with adjustable time delay, sensitivity, and ambient light threshold. It connects directly to line voltage and is suitable for residential and commercial applications.

Funkcje i zalety
- PIR with microcontroller for stable, accurate detection
- Adjustable time delay, Lux level, and sensitivity
- 360° ceiling coverage with 8–12 m detection diameter
- Neutral wire required
- 100–265 VAC wide voltage input
- Cechy
-
Sensor Mode
Occupancy mode; occupancy without light sensor (Lux OFF)
Opóźnienie czasowe
15 s, 30 s, 1 min (default), 3 min, 5 min, 10 min, 30 min
Czujnik światła
Off, 15 Lux, 25 Lux (default), 35 Lux
Sensor Sensitivity
Low Sensitivity, High Sensitivity
Power-Up
1-minute warm-up (no load control during warm-up)
- Working Conditions
-
Źródło zasilania
100 VAC ~ 265 VAC
Częstotliwość zasilania
50 / 60 Hz
Installation Height
2.5 m ~ 3.5 m
Wilgotność robocza
< 93% RH
Temperatura pracy
-10 ~ +40℃
- Detection Capability
-
Detection Diameter
8 m ~ 12 m (<27℃)
Zasięg detekcji
360°
Detection Speed
0.6 ~ 1.5 m/s
- Load Compatibility (RZ037-10A)
-
Fluorescent / Ballast / LED
500 W / 110 VAC; 1000 W / 220 VAC
Incandescent / Halogen
1000 W / 110 VAC; 2200 W / 220 VAC
Versatile Applications
The RZ037 is the ideal ceiling-mounted occupancy sensor solution for 100V ~265V home applications and commercial projects. Perfect for frequently visited spaces, such as public bathrooms, hallways, garages, open offices, breakrooms, stairwells, or corridors.

Bathroom
Occupancy sensor with light sensor enabled is the ideal mode for bathroom usage, especially when you need to use it at night. Manual ON mode can be suitable for long showers.

Garage
Walk in and out of your home garage without the need to reach the light switch with an occupancy sensor switch. Enable daylight sensing to save more energy in the daytime.

Laundry Room
Enjoy the automatic lighting turned on and off for you when arm-full with piles of laundry to wash or clean clothes to take away.

Kitchen
Place an occupancy sensor switch at the entrance and enjoy the automatic lighting while you’re busy cooking and preparing food for your family.

Hallway
Occupancy/vacancy sensor switches can reduce the hours of lighting used by approximately 53% on dark hallways in your basement.

Breakroom
Occupancy sensors can reduce energy waste by 39% and increase energy-saving up to 17% with a 20-minute time delay for breakrooms.

Private Office
Rayzeek motion sensor switches provide max flexibility for office use cases. Occurpnay, vacancy or manual mode, your office, your call.

Conference Room
Vacancy switch with manual override feature is perfect for conference rooms where it’s not frequently used and requires manual turn on and off for presentations.
Filmy
RZ037 User Guide
Fire Resistance Testing – RZ036
Load Testing
Zasoby

Rozszerz swój system czujników ruchu
Może spodoba się również…
-

Sufitowy czujnik ruchu i obecności sieciowy
RZ036-10A- Tryb obecności (Occupancy)
- 100~265V, 10A
- Wymagany przewód neutralny
- 1600 sq ft
-

Przełącznik z czujnikiem ruchu (tryb zajętości / pustostanu / ręczny), niewymagany przewód neutralny, certyfikat UL
RZ021-5A-G- Tryb zajętości, pustostanu, WŁ./WYŁ.
- 120V, 5A
- Wymagany przewód uziemiający
- Pasuje do amerykańskiej puszkowej ściennej 1-Gang
-

Przełącznik z czujnikiem ruchu z trybami zajętości / pustostanu / ręcznym, wymagany przewód neutralny, UK
RZ023-5A- Tryb zajętości, pustostanu, WŁ./WYŁ.
- 100~265V, 5A
- Wymagany przewód neutralny
- Fits the UK square pattress box
-

Przełącznik z czujnikiem ruchu (Occupancy / Vacancy / Manual), wymagana żyła neutralna, EU
RZ022-5A- Tryb zajętości, pustostanu, WŁ./WYŁ.
- 100~265V, 5A
- Wymagany przewód neutralny
- Pasuje do europejskiej puszkowej obudowy okrągłej




Opinie