RZ047-5A 360-graders loftmonteret mikrobølge-bevægelsessensorkontakt
RZ047-5A
RZ047-5A is a 100-265 VAC ceiling-mounted microwave motion sensor switch for automatic indoor lighting control.
The 5A model uses high-frequency microwave Doppler sensing, neutral-required AC wiring, adjustable time delay, selectable Lux threshold, and high/low sensitivity for ceiling-mounted lighting control.
- 100-265 VAC netspændingsindgang, 5A-model
- 5.8 GHz mikrobølgesensor med 360-graders dækning
- 8-12 m detekteringsdiameter under manuelle forhold
- Tidsforsinkelse: 15 s til 30 min
- Lux-indstilling: Fra, 15, 25 eller 35 Lux
Produkthøjdepunkter
- 5A AC model: 100-265 VAC ceiling microwave sensor switch for verified RZ047-5A load ratings.
- Mikrobølgesensor: 5.8 GHz Doppler-detektering med 360-graders loftdækning.
- Installatøropsætning: Trykknapindstillinger for tidsforsinkelse, Lux-grænseværdi og høj/lav følsomhed.
Ikke det, du leder efter? Se vores sortiment:
Rådfør dig med en ekspert
Hurtig levering: 99% på lager
Komplet produktlinje for bevægelsesaktiverede produkter
Send forespørgsel for større ODM/OEM-ordrer

5A Ceiling Microwave Sensing For Automatic Lighting
The RZ047-5A is a ceiling-mounted microwave motion sensor switch for indoor automatic lighting control where overhead sensing is preferred over a wall switch.
It uses 100-265 VAC live, neutral, and load wiring, with push-button adjustment for time delay, Lux threshold, and high/low sensitivity after installation.

360-Degree Microwave Coverage For Everyday Rooms
Microwave Doppler sensing can detect movement through many non-metal materials such as glass, plastic, and thin partitions, which helps ceiling placement cover practical indoor room layouts.
Because that same sensitivity can also detect movement outside the intended area, installers should reduce sensitivity or relocate the sensor when doors, windows, partitions, metal surfaces, or moving fixtures cause nuisance triggering.
Funktioner, fordele, specifikationer
The RZ047-5A combines 5A AC lighting control, 5.8 GHz microwave detection, and adjustable ceiling-sensor settings so installers can verify load fit, placement, and setup before ordering.

Funktioner og fordele
- 5A line-voltage control: Supports 100-265 VAC lighting circuits with the source-backed RZ047-5A load ratings shown in the specifications.
- 5,8 GHz mikrobølgedetektering: Højfrekvent Doppler-detektering registrerer aktivt bevægelse til automatisk belysningsstyring monteret i loftet.
- 360-graders loftdækning: Loftplacering giver bred rumdækning med en detekteringsdiameter på 8-12 m under manuelle forhold.
- Gennemtrængning af ikke-metalliske materialer: Mikrobølgedetektering kan trænge igennem mange typer plast, glas og tynde skillevægge, mens metal blokerer for detektering.
- Justerbar tidsforsinkelse: Vælg 15 s, 30 s, 1 min, 3 min, 5 min, 10 min eller 30 min for at matche mønstrene for persontrafik i rummet.
- Vælgbar Lux-tærskel: Set Off, 15 Lux, 25 Lux, or 35 Lux so the load responds to motion only when the ambient-light condition fits the installation.
- Høj/lav følsomhed: The SENS button helps reduce nuisance detection through doors, glass, partitions, or adjacent spaces.
- Funktioner
-
Model
RZ047-5A
Product type
Loftmonteret mikrobølge-bevægelsessensorkontakt
Sensor type
High-frequency microwave Doppler (HF)
Microwave frequency
5.8 GHz ISM band
Transmission power
0.4 mW
Time delay
15 s, 30 s, 1 min (default), 3 min, 5 min, 10 min, 30 min
Light sensor level
Off, 15 Lux, 25 Lux (default), 35 Lux
Følsomhed
High or Low
Material penetration
Detects through most plastics, glass, and thin partitions; metal blocks detection
- Electrical
-
Power source
100 VAC ~ 265 VAC
Power frequency
50/60 Hz
Ledningsføring
White to Neutral; Red to Load; Black to Live
Power consumption
<=0.5 W standby; 1 W operation
Incandescent / Halogen load
500 W / 110 VAC; 1100 W / 220 VAC
Fluorescent / Ballast / LED load
250 W / 110 VAC; 500 W / 220 VAC
- Detection & Installation
-
Detection diameter
8-12 m
Detection range
360-degree ceiling coverage
Installation height
2.5-5 m
Working temperature
-10 to +40 C
Working humidity
< 93% RH non-condensing
Metal clearance
Keep at least 1 m from large metal or highly reflective surfaces; do not fully enclose in metal
Installation notes
Avoid windows, doors, automatic doors, rotating equipment, HVAC airflow, fans, moving machinery, and vibrating fixtures that may cause nuisance detection
FAQ
How is the RZ047-5A different from a PIR ceiling sensor?
RZ047 uses high-frequency microwave Doppler sensing. It can detect through many non-metal materials such as glass, plastic, and thin partitions, while metal blocks detection.
Does the RZ047-5A need a neutral wire?
Yes. The AC wiring diagram requires White to Neutral, Red to Load, and Black to Live.
What loads can the 5A model control?
The manual lists 500 W / 110 VAC and 1100 W / 220 VAC for incandescent or halogen loads, and 250 W / 110 VAC and 500 W / 220 VAC for fluorescent, ballast, or LED loads.
Can microwave sensing trigger from outside the room?
Yes. The manual warns that microwave sensing can detect through glass, doors, or partitions, so sensitivity should be reduced or the sensor relocated if nuisance detection occurs.
What settings can installers adjust?
Installers can adjust time delay, Lux threshold, and high/low sensitivity using the buttons under the top cover.
Where should the RZ047 be installed?
The manual lists a 2.5-5 m installation height and recommends avoiding windows, doors, automatic doors, rotating equipment, HVAC airflow, fans, moving machinery, vibrating fixtures, and large metal surfaces.



Anmeldelser
Der er endnu ikke nogle anmeldelser.