RZ047-5A 360度吸頂式微波動態感應器開關
RZ047-5A
RZ047-5A is a 100-265 VAC ceiling-mounted microwave motion sensor switch for automatic indoor lighting control.
The 5A model uses high-frequency microwave Doppler sensing, neutral-required AC wiring, adjustable time delay, selectable Lux threshold, and high/low sensitivity for ceiling-mounted lighting control.
- 100-265 VAC 市電輸入,5A 型號
- 5.8 GHz 微波感應,360 度全方位覆蓋
- 8-12 m detection diameter under manual conditions
- 延時時間:15 秒至 30 分鐘
- Lux setting: Off, 15, 25, or 35 Lux
產品亮點
- 5A AC model: 100-265 VAC ceiling microwave sensor switch for verified RZ047-5A load ratings.
- 微波感應: 5.8 GHz Doppler detection with 360-degree ceiling coverage.
- Installer setup: Push-button settings for time delay, Lux threshold, and high/low sensitivity.
未找到您需要的產品? 瀏覽我們的產品系列:
諮詢專家

5A Ceiling Microwave Sensing For Automatic Lighting
The RZ047-5A is a ceiling-mounted microwave motion sensor switch for indoor automatic lighting control where overhead sensing is preferred over a wall switch.
It uses 100-265 VAC live, neutral, and load wiring, with push-button adjustment for time delay, Lux threshold, and high/low sensitivity after installation.

360-Degree Microwave Coverage For Everyday Rooms
Microwave Doppler sensing can detect movement through many non-metal materials such as glass, plastic, and thin partitions, which helps ceiling placement cover practical indoor room layouts.
Because that same sensitivity can also detect movement outside the intended area, installers should reduce sensitivity or relocate the sensor when doors, windows, partitions, metal surfaces, or moving fixtures cause nuisance triggering.
功能、優勢、規格
The RZ047-5A combines 5A AC lighting control, 5.8 GHz microwave detection, and adjustable ceiling-sensor settings so installers can verify load fit, placement, and setup before ordering.

功能與優勢
- 5A line-voltage control: Supports 100-265 VAC lighting circuits with the source-backed RZ047-5A load ratings shown in the specifications.
- 5.8 GHz microwave sensing: High-frequency Doppler detection actively senses movement for ceiling-mounted automatic lighting control.
- 360-degree ceiling coverage: Ceiling placement gives broad room coverage with an 8-12 m detection diameter under manual conditions.
- Non-metal material penetration: Microwave detection can pass through many plastics, glass, and thin partitions, while metal blocks detection.
- 可調延遲時間: Choose 15 s, 30 s, 1 min, 3 min, 5 min, 10 min, or 30 min to match room traffic patterns.
- Selectable Lux threshold: Set Off, 15 Lux, 25 Lux, or 35 Lux so the load responds to motion only when the ambient-light condition fits the installation.
- 高/低靈敏度: The SENS button helps reduce nuisance detection through doors, glass, partitions, or adjacent spaces.
- 功能
-
Model
RZ047-5A
產品類型
吸頂式微波動態感應器開關
感應器類型
High-frequency microwave Doppler (HF)
Microwave frequency
5.8 GHz ISM band
Transmission power
0.4 mW
延時設定
15 秒、30 秒、1 分鐘(預設)、3 分鐘、5 分鐘、10 分鐘、30 分鐘
光感應等級
關閉、15 Lux、25 Lux (預設)、35 Lux
靈敏度
高或低
Material penetration
Detects through most plastics, glass, and thin partitions; metal blocks detection
- Electrical
-
Power source
100 VAC ~ 265 VAC
Power frequency
50/60 Hz
接線方式
White to Neutral; Red to Load; Black to Live
Power consumption
<=0.5 W standby; 1 W operation
Incandescent / Halogen load
500 W / 110 VAC; 1100 W / 220 VAC
Fluorescent / Ballast / LED load
250 W / 110 VAC; 500 W / 220 VAC
- Detection & Installation
-
偵測直徑
8-12 m
偵測範圍
360-degree ceiling coverage
安裝高度
2.5-5 m
工作溫度
-10 to +40 C
工作濕度
< 93% RH non-condensing
Metal clearance
Keep at least 1 m from large metal or highly reflective surfaces; do not fully enclose in metal
Installation notes
Avoid windows, doors, automatic doors, rotating equipment, HVAC airflow, fans, moving machinery, and vibrating fixtures that may cause nuisance detection
常見問題
How is the RZ047-5A different from a PIR ceiling sensor?
RZ047 uses high-frequency microwave Doppler sensing. It can detect through many non-metal materials such as glass, plastic, and thin partitions, while metal blocks detection.
Does the RZ047-5A need a neutral wire?
Yes. The AC wiring diagram requires White to Neutral, Red to Load, and Black to Live.
What loads can the 5A model control?
The manual lists 500 W / 110 VAC and 1100 W / 220 VAC for incandescent or halogen loads, and 250 W / 110 VAC and 500 W / 220 VAC for fluorescent, ballast, or LED loads.
Can microwave sensing trigger from outside the room?
Yes. The manual warns that microwave sensing can detect through glass, doors, or partitions, so sensitivity should be reduced or the sensor relocated if nuisance detection occurs.
What settings can installers adjust?
Installers can adjust time delay, Lux threshold, and high/low sensitivity using the buttons under the top cover.
Where should the RZ047 be installed?
The manual lists a 2.5-5 m installation height and recommends avoiding windows, doors, automatic doors, rotating equipment, HVAC airflow, fans, moving machinery, vibrating fixtures, and large metal surfaces.



商品評價