Contrôleur de détecteur de mouvement pour climatiseur

RZ050

$27.00

The RZ050 is a smart air conditioner motion sensor controller that automatically manages your AC based on room occupancy, saving you up to 20-50% on energy bills. It learns your AC remote’s “Power OFF” command to shut down the AC when the room is vacant, and can optionally learn an “ON” command (or startup temperature) to turn the AC on upon initial room entry.

The wireless & battery-powered design makes for a quick and easy DIY installation. Plus, the intelligent night mode feature suppresses auto-shutoff in the dark (< 1 Lux) for a comfortable night’s sleep without accidental shut-offs. Enjoy a cool, comfortable home without the worry of sky-high energy bills. The RZ050 is perfect for homes, offices, hotels, and B&Bs looking for a simple yet effective way to reduce energy consumption.
En savoir plus

Points forts du produit

  • Smart PIR Motion Sensor: Automatically turns off your AC when vacant, with optional auto-ON upon room entry.
  • Energy Saving: Acting as an advanced occupancy sensor, save energy bills up to 20% ~ 50%.
  • Wireless & Battery-Powered: Easy DIY installation, no wiring required.
  • Learns Your AC Remote: Learns required OFF and optional ON commands (compatible with discrete ON/OFF remote codes).
  • Customizable Time Delay: Choose from 15min, 30min, 1h, or 2h settings.
  • Mode nuit intelligent : Prevents accidental shut-off in the dark (< 1 Lux) while occupants sleep.
  • Window/Door Sensor Option: Need window/door shut-off? Check our RZ050-DS model with magnetic contact sensors.

Livraison rapide : 99% en stock

Gamme complète de produits à détection de mouvement

Demande de renseignements pour les commandes groupées ODM/OEM

Prenez le contrôle de votre climatiseur et de vos factures d'énergie grâce au RZ050

Le contrôleur à détecteur de mouvement pour climatiseur RZ050 est votre solution pour un domicile ou une entreprise plus confortable et plus économe en énergie. Cet appareil intelligent utilise un détecteur de mouvement PIR pour détecter l'occupation d'une pièce, envoyant automatiquement un signal d'extinction (“ OFF ”) lorsque la pièce est vide, tout en prenant en charge un signal d'allumage (“ ON ”) mémorisé en option pour allumer le climatiseur dès la première entrée.

Facile à installer, simple à utiliser et compatible avec la plupart des climatiseurs split, le RZ050 est le choix intelligent pour quiconque souhaite faire des économies et réduire son impact environnemental.

Vous recherchez des détecteurs d'ouverture de portes et fenêtres ? Découvrez la série RZ050-DS

Alors que le RZ050 standard fonctionne comme un contrôleur de mouvement PIR indépendant, notre gamme de produits propose également la surveillance des portes et fenêtres grâce à la série RZ050-DS. Le modèle RZ050-DS s'associe sans fil à des détecteurs de contact magnétique pour éteindre automatiquement le climatiseur dès qu'une porte ou une fenêtre reste ouverte.

Si vos pièces sont fréquemment aérées ou laissées avec des fenêtres ouvertes, découvrez le contrôleur de climatiseur RZ050-DS pour ajouter des détecteurs de contact magnétique à votre installation de climatisation.

Utilisations intelligentes de votre RZ050 : contrôle de la température à double point de consigne et bien plus

Au-delà de la simple extinction de votre climatiseur, le RZ050 offre un contrôle intelligent de la température à double point de consigne. En lui faisant apprendre des commandes de température spécifiques à partir de la télécommande de votre climatiseur, vous pouvez adopter une approche plus nuancée de la gestion du climat.

Régulation de la température à double point de consigne

Grâce à la capacité d'apprentissage du RZ050, vous pouvez le programmer pour basculer entre une température active et une température d'économie au lieu de couper complètement l'alimentation. Par exemple, il peut transmettre une température de démarrage confortable (telle que 21 °C) lorsque quelqu'un entre dans la pièce, et passer à une température d'économie d'énergie (telle que 28 °C) lorsque la pièce est inoccupée, garantissant le confort tout en réduisant au minimum le gaspillage d'énergie.

Idéal pour les hôtels, chambres d'hôtes, locations de vacances, bureaux et habitations

Le RZ050 est une solution polyvalente pour tout environnement utilisant des climatiseurs. Les hôtels et chambres d'hôtes peuvent réduire considérablement leurs coûts d'énergie en empêchant les clients de laisser la climatisation fonctionner dans des chambres vides. Les bureaux peuvent bénéficier d'une extinction automatisée en dehors des heures de travail ou dans les salles de réunion inutilisées. Et les foyers peuvent profiter du confort et des économies d'un système de climatisation intelligent sans devoir effectuer d'emplacements coûteux.

Caractéristiques, avantages, spécifications

Caractéristiques et avantages

  • Éteint automatiquement le climatiseur lorsque la pièce est laissée vide, avec option d'allumage automatique dès l'entrée dans la pièce.
  • Compatible avec les climatiseurs split contrôlés par télécommande (nécessite un code OFF distinct pour l'arrêt ; codes ON et OFF distincts pour le double contrôle).
  • Mode nuit intelligent : Supprime l'arrêt automatique dans l'obscurité (< 1 Lux) pour protéger les occupants qui dorment, tout en conservant l'allumage activé par le mouvement dès l'entrée.
  • Sûr et fiable : Operates via infrared commands without interfering with your AC’s internal wiring or warranty.
  • Battery-Powered: Cordless operation with at least 1 year battery life using 2 standard AAA batteries.
  • Wireless Design: Fast, easy DIY installation—simply mount with included adhesive tape or screws.
  • Adjustable Time Delay: Select from 15min, 30min, 1h (default), or 2h vacancy countdowns (automatically clamps to 1h or 2h in Night Mode).
  • Window/Door Sensor Option: Need opening sensors? Check our companion RZ050-DS model designed for door and window monitoring.
  • Low Battery Indicator: Flashes red light 5 times to notify you when batteries need replacing.
  • Motion Detection Light: Red lens detection indicator can be turned ON/OFF as desired.
Caractéristiques

Tension

2.5V-3.5VDC(2 AAA batteries)

Time delay

options 15min, 30min, 1h(default), 2h.

Motion Detecting range

6-9M Max

IR transmitting range

<10M

IR Transmitting direction

30 degree

Montage

Screwing or sticking on the wall

Supported commands

Learned IR OFF (required); learned IR ON or dual temperature setpoints (optional)

Dimensions

45 x 70 x 64 mm

Indoor use only

Indoor use only, 0~40°C relative humidity: up to 90%

Tableau comparatif

RZ050 Product Image RZ050 RZ050-DP Product Image RZ050-DP RZ050-DS Product Image RZ050-DS
Auto AC Control Modes
  • Turn AC OFF
  • Turn AC ON & OFF (Optional)
  • Turn AC OFF
  • Turn AC ON & OFF
  • Turn AC OFF
Window/Door Sensor Compatible
  • No
  • No
  • Standard kits include 1 or 2 door sensors (RZ050-DS-1 / RZ050-DS-2)
  • Extra door sensors purchasable
Power Supply
  • Battery Only
  • Battery
  • USB *
  • USB Only *

Note : USB Power adaptor not included in the package, purchase here(Plug type: US, UK, EU).

FAQ

Will the RZ050 work with my AC unit?

The RZ050 is compatible with split AC units operated by infrared remotes with discrete commands. For vacancy shutoff only, a discrete OFF command is required. For dual turn-ON and turn-OFF control, the remote must have separate, discrete codes for ON and OFF. Remotes with a single toggle button for both power ON and OFF are not supported.

How do I install the RZ050 Air Conditioner Occupancy Sensor?

Installation is simple and requires no wiring. You can either stick the device to the wall using the included adhesive or mount it with screws. Detailed instructions are provided in the user manual.

How long does the battery last?

The RZ050 is designed for long battery life, typically lasting at least one year with normal use.

What is Night Mode?

Night Mode prevents the AC from turning off while you sleep. When ambient brightness is below 1Lux, the controller suppresses the automatic OFF command so sleeping occupants are not interrupted. Motion detection remains active and can still turn the AC ON upon room entry if the ON command has been learned.

Can I use the RZ050 to turn my AC ON?

Yes. In addition to the required OFF command, the RZ050 can learn an optional ON command (or startup temperature) from your AC remote. Upon the first motion detected when entering an unoccupied room, the RZ050 automatically transmits the learned ON signal to your AC. Note: To configure automatic turn-ON, the ON command must be learned immediately following the OFF command setup by holding the Mode button for 10 seconds. Re-learning an OFF command clears any previously stored ON command.

Why won’t the AC turn back on automatically after I turn it off with my remote?

The RZ050 operates open-loop without telemetry feedback from the AC. If you manually turn off the AC with your remote while staying in the room, the RZ050 still assumes the room is occupied and the AC is running. In this state, motion only resets the vacancy countdown. To restore automatic turn-ON, the space must remain vacant until the time delay expires and the RZ050 transmits its own OFF signal, or you can turn the AC back on manually with the remote.

What is the warranty on the RZ050?

The RZ050 comes with a 1-year limited warranty.

What if I have trouble with the RZ050?

Please refer to the troubleshooting guide in the user manual. If you still need assistance, contact our customer support at [email protected].

Can I use door and window sensors with the RZ050?

The standard RZ050 is an independent PIR motion controller and does not connect to external door sensors. If you need your AC to automatically shut down when doors or windows are left open, that capability is supported by another model in our series: the RZ050-DS Air Conditioner Controller, which pairs wirelessly with RZ001 magnetic contact sensors.

How does temperature-based control work instead of turning the AC completely off?

The RZ050 can learn specific temperature signals from your AC remote instead of power commands. It learns an active startup temperature (e.g., 21°C) triggered upon room entry, and an energy-saving setback temperature (e.g., 28°C) triggered after the vacancy delay expires.

Vidéos

Présentation du détecteur de mouvement pour climatisation RZ050

Guide d'utilisation du RZ050

RZ050 AC Compatibility Test

Détecteur de présence UE rz022 c2a

Développez vos détecteurs de mouvement

Découvrez tous nos produits d'économie d'énergie pour détecteurs de mouvement

3 avis pour Air Conditioner Motion Sensor Controller

  1. 5 sur 5

    mensouri –

    bonjour
    fonctionne très bien même sur un téléviseur j’ai pas encor essayer sur une climatisation il dois faire le job

  2. 5 sur 5

    Ángel –

    Muy buen sensor y detector rz050 tanto de puertas y como las dos cosas conjuntamente y muy amables y te informan de todo al detalle y rápido envío lo recomiendo 100x 100 todo funciona bien contento

  3. 5 sur 5

    Dan –

    Quality: very good designed and robust sensors, easy to setup, a very good and intuitive product.
    Design: optimal design, nice, small, good components and robust.
    Service: Big thank you for the great support, and generally from the Rayzeek team, very trustworth and answering every question in a very professional way, they assist you with any problem or information you need.

Ajouter un Avis

Vous aimerez peut-être aussi…

French