Product video
Hochvolt-Präsenz-Bewegungssensor für Deckenmontage
RZ036-5A
$15.00
RZ036-5A is a line voltage passive infrared(PIR) technology ceiling mount occupancy sensor that is commonly used as an automatic light switch or fan switch for commercial and residential applications.
The line voltage ceiling mount occupancy sensor RZ036-5a does not require power packs, they are directly installed and mounted on the ceiling. Rayzeek 036-5A ceiling mounted occupancy sensors offer detection coverage up to 1600 sq ft. with a 5A high current rating which is capable of controlling multiple lighting fixtures and exhaust fans.
Hauptmerkmale:
- Auto-EIN/Auto-AUS Präsenzmodus
- 360-degree detection coverage up to 1600 sq ft.
- 100V ~ 265V for residential and commercial application
- Time delay, light sensor Lux value and sensitivity adjustment
- Certification: FCC, RoHS certified
Produkt-Highlights
- Line voltage, 5A current rating
- Neutral required.
- Ceiling Mount Occupancy Sensor, PIR motion sensor
Nicht das, wonach Sie suchen? Unser Portfolio ansehen:
Experten konsultieren
Schnelle Lieferung: 99% auf Lager
Vollständige bewegungsaktivierte Produktlinie
Anfragen für ODM/OEM-Großbestellungen

Präsenzmelder für Deckenmontage
The RZ036 ceiling mount occupancy sensor, also referred to as a ceiling mount motion sensor or motion detector, utilizes advanced passive infrared(PIR) motion sensor technology to provide our users a better motion detecting performance.
The RZ036-5A model offers a 5A current rating which is adequate for most residential lighting usage, such as hallway lighting or control fans.

Einfache Einstellungen
Rayzeek entwickelt Bewegungssensoren unter dem Aspekt höchster Benutzerfreundlichkeit. Einstellungen können mühelos über Drucktasten und Anzeigeleuchten von Hand vorgenommen werden. Es ist kein Schraubendreher mehr erforderlich.
Anwender können die Sensorempfindlichkeit von hoch bis niedrig, die Zeitverzögerung von 30 Sek. bis 30 Min. und den Umgebungslichtwert von 15 bis 35 LUX anpassen oder diesen deaktivieren, damit der Sensor auch tagsüber arbeitet.

In jeder Hinsicht überlegen
Die Präsenzmelder der Serie RZ036 für Deckenmontage bieten ein 360-Grad-Sichtfeld mit einem großen Erfassungsbereich von bis zu 1600 sq. ft, um Bewegungen von jedem Punkt im Raum aus zu erfassen.
Durch das flache und elegante Design fügen sich RZ036 Bewegungssensoren harmonisch in jede Decke und jeden Einrichtungsstil ein. Der Präsenzmelder fügt sich unauffällig ein und sorgt für eine optimale Bewegungserkennung.
Funktionen, Vorteile, Spezifikationen
Der RZ036 Decken-Präsenzmelder ist eine universelle Bewegungssensor-Lösung für die Deckenmontage, die sich optimal für nahezu alle Wohn- und Gewerbeanwendungen eignet.

Funktionen & Vorteile
- Fortschrittliche PIR-Technologie mit einem integrierten Detektor für präzise und hochempfindliche Leistung.
- Hergestellt aus hochsicherem, feuerfestem Material.
- Das integrierte Magnet-Bistabil-Relais bietet eine höhere Leistungsfähigkeit im Vergleich zu herkömmlichen Relais.
- Einstellbare Zeitverzögerung von 15 Sek., 30 Sek., 1 Min., 3 Min., 5 Min., 10 Min. bis 30 Min.
- Einstellbarer Lichtsensorwert: AUS, 15 Lux, 25 Lux bis 35 Lux
- Einstellbare Empfindlichkeit (Erfassungsbereich) von niedrig bis hoch.
- FCC, CE, RoHS certified.
- Eigenschaften
Sensor Mode
Occupancy mode, Occupancy without light sensor mode
Time-Delay
15 s, 30s, 1 min(default), 3 min, 5 min, 10 min, 30 min
Lichtsensor
Off, 15 Lux, 25 Lux (default), 35 Lux
Sensor Sensitivity
Low Sensitivity, High Sensitivity
- Working Conditions
Power Source
110 VAC ~ 265 VAC
Netzfrequenz
50 / 60Hz
Installation Height
2.6 m ~ 3.5 m
Betriebsfeuchtigkeit
< 93%RH
Betriebstemperatur
-10 ~ +40℃
- Detection Capability
Detection Distance
12 m ~ 18 m (<27℃)
Detection Range
360°
Detection Speed
0.6 ~ 1.5m/s
- Bulb Compatibility
Fluorescent / Ballast / LED
500 W / 220 VAC
Incandescent / Halogen
1100 W / 220 VAC
Versatile Applications
The RZ036 is the ideal ceiling-mounted occupancy sensor solution for 100V ~265V home applications and commercial projects. Perfect for frequently visited spaces, such as public bathrooms, hallways, garages, open offices, breakrooms, stairwells, or corridors.

Bathroom
Occupancy sensor with light sensor enabled is the ideal mode for bathroom usage, especially when you need to use it at night. Manual ON mode can be suitable for long showers.

Garage
Walk in and out of your home garage without the need to reach the light switch with an occupancy sensor switch. Enable daylight sensing to save more energy in the daytime.

Laundry Room
Enjoy the automatic lighting turned on and off for you when arm-full with piles of laundry to wash or clean clothes to take away.

Kitchen
Place an occupancy sensor switch at the entrance and enjoy the automatic lighting while you’re busy cooking and preparing food for your family.

Hallway
Occupancy/vacancy sensor switches can reduce the hours of lighting used by approximately 53% on dark hallways in your basement.

Breakroom
Occupancy sensors can reduce energy waste by 39% and increase energy-saving up to 17% with a 20-minute time delay for breakrooms.

Private Office
Rayzeek motion sensor switches provide max flexibility for office use cases. Occurpnay, vacancy or manual mode, your office, your call.

Conference Room
Vacancy switch with manual override feature is perfect for conference rooms where it’s not frequently used and requires manual turn on and off for presentations.
Videos
RZ036 Installation
RZ036 Benutzerhandbuch
Fire Resistance Testing – RZ036
Load Testing
Ressourcen
2 Rezensionen für Ceiling Mount Line Voltage Occupancy Motion Sensor
Das könnte dir auch gefallen …
-

Präsenz- / Vakanz- / manueller Bewegungsmelderschalter, kein Neutralleiter erforderlich, UL-gelistet
RZ021-5A-G- Präsenz-, Vakanz-, EIN/AUS-Modus
- 120V, 5A
- Erdungsleiter erforderlich
- Passend für US-1-Gang-Unterputzdosen
-

Präsenz- / Leerstands- / Manueller Bewegungssensorschalter, Neutralleiter erforderlich, EU
RZ022-5A- Präsenz-, Vakanz-, EIN/AUS-Modus
- 100~265V, 5A
- Neutralleiter erforderlich
- Passend für die europäische runde Unterputzdose
-

Hochvolt-Präsenz-Bewegungssensor für Deckenmontage
RZ036-10A- Präsenzmodus
- 100~265V, 10A
- Neutralleiter erforderlich
- 1600 sq ft
-

Präsenz- / Leerstands- / Manueller Bewegungssensorschalter, Neutralleiter erforderlich, UK
RZ023-5A- Präsenz-, Vakanz-, EIN/AUS-Modus
- 100~265V, 5A
- Neutralleiter erforderlich
- Passend für die britische quadratische Aufputzdose





Tim.K –
The sensor works great so far on our project.
Rob –
It has a low profile look with style, matches our ceiling decor. Exactly what we need.