Product video
Sufitowy czujnik ruchu i obecności o napięciu sieciowym (RZ037-10A)
RZ037-10A
$17.00
RZ037-10A is a line voltage passive infrared (PIR) ceiling-mount occupancy sensor for automatic lighting and fan control in residential and commercial spaces.
Main Features:
- Auto-ON/Auto-OFF occupancy mode (Lux override available)
- 360-degree coverage; 8–12 m detection diameter
- 100V ~ 265V AC line voltage, 10A rating
- Push-button adjustment: time delay, Lux, sensitivity
- Neutral wire required; 3-wire (L, N, Load) wiring
Główne cechy produktu
- Line voltage 100–265V AC, 10A rating (neutral required)
- 360° ceiling-mount PIR with 8–12 m detection diameter
- Push-button setup: Time, Lux, Sensitivity
Nie tego szukasz? Zobacz nasze portfolio:
Skonsultuj się z ekspertem
Szybka dostawa: 99% w magazynie
Pełna linia produktów aktywowanych ruchem
Wyślij zapytanie dla hurtowych zamówień ODM/OEM

Sufitowy czujnik obecności
RZ037-10A to montowany na suficie czujnik ruchu PIR o kącie detekcji 360 stopni, zapewniający niezawodne sterowanie oświetleniem. Dzięki zastosowaniu zaawansowanej technologii pasywnej podczerwieni (PIR) oraz mikrokontrolera oferuje stabilną detekcję i łatwą konfigurację, ułatwiając zmniejszenie zużycia energii.
Dzięki prądowi znamionowemu 10 A obsługuje większe obciążenia oświetleniowe oraz wiele opraw w zastosowaniach domowych i komercyjnych.

Łatwa regulacja
Konfiguracja za pomocą przycisków pod górną pokrywą bez użycia narzędzi. Możliwości konfiguracji:
- Opóźnienie czasowe: od 15 s do 30 min
- Poziom czujnika światła: WYŁ., 15, 25 (domyślnie), 35 luksów
- Czułość: Wysoka lub Niska
Uwaga: Po pierwszym włączeniu zasilania lub jego przywróceniu następuje 1-minutowy rozruch, podczas którego obciążenie nie jest sterowane.
Funkcje, zalety, specyfikacja
Sufitowy czujnik obecności RZ037-10A zapewnia szerokie pole widzenia 360° z regulowanym opóźnieniem czasowym, czułością i progiem natężenia światła otoczenia. Podłącza się go bezpośrednio do napięcia sieciowego, co czyni go odpowiednim do zastosowań domowych i komercyjnych.

Funkcje i zalety
- Czujnik PIR z mikrokontrolerem zapewniający stabilną i dokładną detekcję
- Regulowane opóźnienie czasowe, poziom natężenia światła (Lux) i czułość
- Sufitowe pole widzenia 360° o średnicy detekcji 8–12 m
- Wymagany przewód neutralny
- Szeroki zakres napięcia wejściowego 100–265 VAC
- Cechy
-
Tryb czujnika
Tryb obecności; tryb obecności bez czujnika światła (Lux WYŁ.)
Opóźnienie czasowe
15 s, 30 s, 1 min (domyślnie), 3 min, 5 min, 10 min, 30 min
Czujnik światła
Wył., 15 Lux, 25 Lux (domyślnie), 35 Lux
Czułość czujnika
Low Sensitivity, High Sensitivity
Power-Up
1-minute warm-up (no load control during warm-up)
- Working Conditions
-
Źródło zasilania
100 VAC ~ 265 VAC
Częstotliwość zasilania
50 / 60 Hz
Installation Height
2.5 m ~ 3.5 m
Wilgotność robocza
< 93% RH
Temperatura pracy
-10 ~ +40℃
- Detection Capability
-
Detection Diameter
8 m ~ 12 m (<27℃)
Zasięg detekcji
360°
Detection Speed
0.6 ~ 1.5 m/s
- Load Compatibility (RZ037-10A)
-
Fluorescent / Ballast / LED
500 W / 110 VAC; 1000 W / 220 VAC
Incandescent / Halogen
1000 W / 110 VAC; 2200 W / 220 VAC
Versatile Applications
The RZ037 is the ideal ceiling-mounted occupancy sensor solution for 100V ~265V home applications and commercial projects. Perfect for frequently visited spaces, such as public bathrooms, hallways, garages, open offices, breakrooms, stairwells, or corridors.

Bathroom
Occupancy sensor with light sensor enabled is the ideal mode for bathroom usage, especially when you need to use it at night. Manual ON mode can be suitable for long showers.

Garage
Walk in and out of your home garage without the need to reach the light switch with an occupancy sensor switch. Enable daylight sensing to save more energy in the daytime.

Laundry Room
Enjoy the automatic lighting turned on and off for you when arm-full with piles of laundry to wash or clean clothes to take away.

Kuchnia
Place an occupancy sensor switch at the entrance and enjoy the automatic lighting while you’re busy cooking and preparing food for your family.

Hallway
Occupancy/vacancy sensor switches can reduce the hours of lighting used by approximately 53% on dark hallways in your basement.

Breakroom
Occupancy sensors can reduce energy waste by 39% and increase energy-saving up to 17% with a 20-minute time delay for breakrooms.

Gabinet prywatny
Rayzeek motion sensor switches provide max flexibility for office use cases. Occurpnay, vacancy or manual mode, your office, your call.

Sala konferencyjna
Vacancy switch with manual override feature is perfect for conference rooms where it’s not frequently used and requires manual turn on and off for presentations.
Filmy
RZ037 User Guide
Fire Resistance Testing – RZ036
Load Testing
Zasoby

Rozszerz swój system czujników ruchu
Może spodoba się również…
-

Sufitowy czujnik ruchu i obecności sieciowy
RZ036-10A- Tryb obecności (Occupancy)
- 100~265V, 10A
- Wymagany przewód neutralny
- 1600 sq ft
-

Przełącznik z czujnikiem ruchu (tryb zajętości / pustostanu / ręczny), niewymagany przewód neutralny, certyfikat UL
RZ021-5A-G- Tryb zajętości, pustostanu, WŁ./WYŁ.
- 120V, 5A
- Wymagany przewód uziemiający
- Pasuje do amerykańskiej puszkowej ściennej 1-Gang
-

Przełącznik z czujnikiem ruchu z trybami zajętości / pustostanu / ręcznym, wymagany przewód neutralny, UK
RZ023-5A- Tryb zajętości, pustostanu, WŁ./WYŁ.
- 100~265V, 5A
- Wymagany przewód neutralny
- Pasuje do brytyjskiej kwadratowej puszki montażowej
-

Przełącznik z czujnikiem ruchu (Occupancy / Vacancy / Manual), wymagana żyła neutralna, EU
RZ022-5A- Tryb zajętości, pustostanu, WŁ./WYŁ.
- 100~265V, 5A
- Wymagany przewód neutralny
- Pasuje do europejskiej puszkowej obudowy okrągłej




Opinie
Na razie nie ma opinii o produkcie.