Damp location is an interior or exterior area that is periodically or regularly exposed to moisture condensation on, in, or near electrical equipment. These locations can also include partially protected regions. Damp locations are characterized by the presence of moisture, high humidity, or the potential for condensation, but not direct contact with water. Examples of damp locations include bathrooms, laundry rooms, and covered outdoor areas like patios and porches.

Vielleicht interessiert Sie

  • Deckenmontierter PIR-Anwesenheitssensor mit Trockenkontakt-Relaisausgang
  • 12/24VDC oder 12/24VAC Niedervoltversorgung
  • COM, NO und NC isolierte Relaiskontakte für EMS-, HVAC- und Gebäudesteuerungseingänge
RZ048 einbaufähiges Decken-Mikrowellen-Bewegungssensor-Produktbild
  • Niedervolt-DC-Einbaudeckenmontierter Mikrowellen-Bewegungssensor-Schalter
  • 12 VDC / 24 VDC Eingang mit 10-30 VDC Bereich
  • 10A max. Betriebsstrom mit einstellbarer Zeitverzögerung, Lux-Schwellenwert und Empfindlichkeit
RZ048 einbaufähiges Decken-Mikrowellen-Bewegungssensor-Produktbild
  • Einbaudeckenmontierter Mikrowellen-Bewegungssensor-Schalter für höhere Last
  • 100-265 VAC Netzspannungseingang, 10A-Modell
  • 5,8 GHz Mikrowellenerkennung mit einstellbarer Zeitverzögerung, Lux-Schwellenwert und Empfindlichkeit
RZ048 einbaufähiges Decken-Mikrowellen-Bewegungssensor-Produktbild
  • Eingelassener Decken-Mikrowellen-Bewegungssensor-Schalter
  • 100-265 VAC Netzspannungseingang, 5A-Modell
  • 5,8 GHz Mikrowellenerkennung mit einstellbarer Zeitverzögerung, Lux-Schwellenwert und Empfindlichkeit
  • Deckenmontierter RZ037 PIR Belegungssensor-Dimmer für 220V
  • Max. Betriebsstrom 3A bei 660W Nennlast
  • LUX-Taste steuert Lichtsensor EIN/AUS und benutzerdefinierte Dimmhelligkeit
  • Deckenmontierter RZ037 PIR Belegungssensor-Dimmer für 110V
  • Max. Betriebsstrom 3A bei 330W Nennlast
  • LUX-Taste steuert Lichtsensor EIN/AUS und benutzerdefinierte Dimmhelligkeit
RZ047 deckenmontierter Mikrowellen-Bewegungssensor-Schalter
  • Niedervolt-DC Decken-Mikrowellen-Bewegungssensor-Schalter
  • 12 VDC / 24 VDC Eingang mit 10-30 VDC Bereich
  • 10A max. Betriebsstrom mit einstellbarer Zeitverzögerung, Lux-Schwellenwert und Empfindlichkeit
RZ047 deckenmontierter Mikrowellen-Bewegungssensor-Schalter
  • Höher belastbarer Decken-Mikrowellen-Bewegungssensor-Schalter
  • 100-265 VAC Netzspannungseingang, 10A-Modell
  • 5,8 GHz Mikrowellenerkennung mit einstellbarer Zeitverzögerung, Lux-Schwellenwert und Empfindlichkeit
RZ047 deckenmontierter Mikrowellen-Bewegungssensor-Schalter
  • Decken-Mikrowellen-Bewegungssensor-Schalter
  • 100-265 VAC Netzspannungseingang, 5A-Modell
  • 5,8 GHz Mikrowellenerkennung mit einstellbarer Zeitverzögerung, Lux-Schwellenwert und Empfindlichkeit
RZ038 einbaufähiger Decken-PIR-Bewegungssensor, Seiten- und Draufsicht
  • Niedervolt-DC eingelassener Decken-PIR-Bewegungssensor-Schalter
  • 12 VDC / 24 VDC Eingang mit 10-30 VDC Bereich
  • Max. Betriebsstrom 10A mit einstellbarer Zeitverzögerung, Lux-Schwellwert und Empfindlichkeit
RZ038 einbaufähiger Decken-PIR-Bewegungssensor, Vorderansicht
  • Höher belastbarer eingelassener Decken-PIR-Bewegungssensor-Schalter
  • 100-265 VAC Netzspannungseingang, 10A-Modell
  • 360-Grad-Erkennung mit einstellbarer Zeitverzögerung, Lux-Schwellwert und Empfindlichkeit
RZ038 einbaufähiger Decken-PIR-Bewegungssensor, Vorderansicht
  • Eingelassener Decken-PIR-Bewegungssensor-Schalter
  • 100-265 VAC Netzspannungseingang, 5A-Modell
  • 360-Grad-Erkennung mit einstellbarer Zeitverzögerung, Lux-Schwellwert und Empfindlichkeit
RZ040 kabelloses Schalter- und Empfänger-Set
  • Kabelloses Schalter- und Empfänger-Kit für Innenbeleuchtungssteuerung EIN/AUS
  • 100-230VAC, 50/60Hz Empfänger mit 5A Nennstrom
  • CR2032-betriebener kabelloser Schalter mit 2,4GHz-Kommunikation
  • Belegung (Auto-EIN/Auto-AUS)
  • 12–24V DC (10–30VDC), bis zu 10A
  • 360°-Abdeckung, 8–12 m Durchmesser
  • Zeitverzögerung 15 s–30 min
  • Lichtsensor Aus/15/25/35 Lux
  • Hohe/Niedrige Empfindlichkeit
  • Auto-EIN/Auto-AUS Belegungsmodus
  • 100–265V AC, 10A (Nulleiter erforderlich)
  • 360°-Abdeckung; 8–12 m Erkennungsdurchmesser
  • Zeitverzögerung 15 s–30 min; Lux AUS/15/25/35; Empfindlichkeit Hoch/Niedrig
  • Auto-EIN/Auto-AUS Belegungsmodus
  • 100–265V AC, 5A (Nulleiter erforderlich)
  • 360°-Abdeckung; 8–12 m Erkennungsdurchmesser
  • Zeitverzögerung 15 s–30 min; Lux AUS/15/25/35; Empfindlichkeit Hoch/Niedrig
  • 100V-230VAC
  • Übertragungsdistanz: bis zu 20m
  • Kabelloser Bewegungssensor
  • Festverdrahtete Steuerung
  • Spannung: 2x AAA-Batterien / 5V DC (Micro-USB)
  • Tag/Nacht-Modus
  • Zeitverzögerung: 15min, 30min, 1h(Standard), 2h

When selecting light fixtures for damp locations, choose fixtures that are specifically labeled as “damp rated.” These fixtures are designed to withstand the moisture and humidity present in these areas without compromising safety or performance. It is important to note that damp-rated lighting solutions differ from wet-rated lighting solutions. Wet-rated lights are specifically designed to withstand direct exposure to water, such as rain or water splashes, and are suitable for outdoor areas where they may come into direct contact with moisture.

Frequently Asked Questions

What Is the Difference Between Damp and Wet Locations

One rating is specifically designed to handle direct exposure to water, while the other rating does not have this capability.

What Is a Damp Location Per NEC

The NEC defines a damp location as an area that is shielded from weather conditions and not prone to being saturated with water or other liquids, but is exposed to moderate levels of moisture. An additional note accompanying this definition offers a few instances of damp locations, such as “certain basements.”

Is a Shower Light a Wet or Damp Location

Indoor locations such as showers are classified as wet locations. If a light fixture can come into direct contact with water splashes or flows, it is considered a wet location. Dutton Brown Design’s light fixtures are mostly UL Listed for dry locations, indicating they are not suitable for wet environments like showers.

What Are Indoor Damp Locations

Indoor Damp Locations encompass areas such as indoor pool areas, utility rooms, and spaces above bathtubs or showers in bathrooms (where there is no direct water contact).

Can LED Bulbs Be Used in Damp Locations

LED bulbs that are listed for damp locations are commonly utilized indoors in areas such as laundry rooms, over showers and bathtubs, utility rooms, unfinished basements, and similar spaces.

Do You Need Damp Rated Lighting for Bathroom

No, you don’t always require damp-rated lighting in your bathroom. The majority of areas in these spaces are exposed to only minimal levels of moisture, and proper ventilation helps prevent condensation. Feel free to explore our selection of bathroom lighting options, which include dry, damp, and wet fixtures, to create your ideal oasis.

What Device Is Used in Damp Locations

For areas that are wet or damp, such as when it needs to be buried directly in the ground, UF-B (underground feeder) cable is the appropriate device to use. This type of cable is designed with solid, water-proof plastic vinyl sheaths that fully protect the individual conductors from moisture, making it suitable for damp locations.

Do Kitchen Lights Need to Be Damp Rated

An additional requirement is that fixtures should have a damp or wet location rating. It is important to note that most lighting fixtures available in the market are only dry-rated. In space-efficient bathrooms, sconces are preferred over pendants and chandeliers as they are more suitable for small spaces and can be easily adjusted around mirrors.

Is It OK to Put LED Lights in the Bathroom

LED light bulbs are a great choice for bathroom fixtures due to their energy efficiency and durability. According to the U.S. Department of Energy, LED bulbs can last up to 25,000 hours, making them a long-lasting option that outperforms traditional light bulbs. Additionally, LED bulbs are less likely to overheat, making them a safe and reliable choice for bathroom lighting.

What Does Zone 1 and 2 Mean in Bathroom Lighting

Zone 1 in bathroom lighting refers to the area directly above the bath or shower, extending up to 2.25 meters from the floor. On the other hand, Zone 2 pertains to the lighting positioned on either side of the bath, shower, or wash basin, up to 600mm (0.6m) outside the perimeter of the water sources, and also up to 2.25m from the floor. Any areas that are not within these designated zones are considered as outside zones.