RZ048-10A 360-graders indbygget loftmonteret mikrobølge-bevægelsessensor-afbryder
RZ048-10A
RZ048-10A is the higher-load AC version of the recessed ceiling microwave motion sensor switch for automatic lighting control.
It keeps the same 5.8 GHz microwave sensing and recessed RZ048 ceiling form as the 5A model while using source-backed 10A load ratings for compatible 100-265 VAC lighting circuits.
- 100-265 VAC netspændingsindgang, 10A-model
- 5.8 GHz mikrobølgesensor med 360-graders dækning
- 8-12 m detekteringsdiameter under manuelle forhold
- Tidsforsinkelse: 15 s til 30 min
- Lux-indstilling: Fra, 15, 25 eller 35 Lux
Produkthøjdepunkter
- 10A AC-model: 100-265 VAC recessed ceiling microwave sensor switch with higher source-backed load ratings than the 5A model.
- Mikrobølgesensor: 5.8 GHz Doppler-detektering med 360-graders loftdækning.
- Recessed mounting: Screw mount or spring clip mount with an 82-90 mm circular ceiling cutout.
Ikke det, du leder efter? Se vores sortiment:
Rådfør dig med en ekspert
Hurtig levering: 99% på lager
Komplet produktlinje for bevægelsesaktiverede produkter
Send forespørgsel for større ODM/OEM-ordrer

Higher-Load AC Microwave Control In A Recessed Ceiling Form
The RZ048-10A is the higher-load AC model in the RZ048 recessed ceiling microwave sensor family, built for automatic lighting control where a ceiling sensor is the right detection position.
Den anvender 100-265 VAC fase-, nul- og tændledningsføring med manuel justering af tidsforsinkelse, Lux-tærskel og høj/lav følsomhed efter installation.

AC-registrering med højere belastning til fælles indendørs belysning
Use the RZ048-10A when the project needs the recessed RZ048 microwave sensing platform and the higher verified AC load profile shown in the manual.
Placering i loftet kan passe til korridorer, fællesrum, sekundære rum og lignende indendørsområder, forudsat at sensoren placeres, så uønsket registrering gennem døre, vinduer, skillevægge, metaloverflader eller udstyr i bevægelse undgås.
Funktioner, fordele, specifikationer
The RZ048-10A pairs 10A AC load ratings with recessed mounting and 5.8 GHz microwave detection so installers can compare load capacity, room coverage, and adjustment options.

Funktioner og fordele
- 10A netspændingsstyring: Supports 100-265 VAC lighting circuits with the source-backed RZ048-10A load ratings shown in the specifications.
- Højere AC-belastningsprofil: The 10A model is the RZ048 choice when the verified lighting load exceeds the 5A model rating.
- 5,8 GHz mikrobølgedetektering: Højfrekvent Doppler-detektering registrerer aktivt bevægelse til automatisk belysningsstyring monteret i loftet.
- Recessed ceiling form: Screw mount or spring clip mounting supports a low-profile ceiling installation with the documented 82-90 mm cutout.
- 360-graders loftdækning: Loftplacering giver bred rumdækning med en detekteringsdiameter på 8-12 m under manuelle forhold.
- Gennemtrængning af ikke-metalliske materialer: Mikrobølgedetektering kan trænge igennem mange typer plast, glas og tynde skillevægge, mens metal blokerer for detektering.
- Høj/lav følsomhed: The SENS button helps reduce nuisance detection through doors, glass, partitions, or adjacent spaces.
- Funktioner
-
Model
RZ048-10A
Product type
Indbygget loftmonteret mikrobølge-bevægelsessensorkontakt
Sensor type
High-frequency microwave Doppler (HF)
Microwave frequency
5.8 GHz ISM band
Transmission power
0.4 mW
Time delay
15 s, 30 s, 1 min (default), 3 min, 5 min, 10 min, 30 min
Light sensor level
Off, 15 Lux, 25 Lux (default), 35 Lux
Følsomhed
High or Low
Material penetration
Detects through most plastics, glass, and thin partitions; metal blocks detection
- Electrical
-
Power source
100 VAC ~ 265 VAC
Power frequency
50/60 Hz
Ledningsføring
White to Neutral; Red to Load; Black to Live
Power consumption
0.5 W or less standby; 1 W operation
Incandescent / Halogen load
1000 W / 110 VAC; 2200 W / 220 VAC
Fluorescent / Ballast / LED load
500 W / 110 VAC; 1000 W / 220 VAC
- Detection & Installation
-
Detection diameter
8-12 m
Detection range
360-degree ceiling coverage
Installation height
2.5-5 m
Working temperature
-10 to +40 C
Working humidity
< 93% RH non-condensing
Mounting methods
Screw mount or spring clip mount
Ceiling cutout
82-90 mm circular hole for spring clip mounting
Face diameter
106 mm
Body diameter
78 mm
Height
64 mm overall; 25 mm lower visible section
Metal clearance
Keep at least 1 m from large metal or highly reflective surfaces; do not fully enclose in metal
Installation notes
Avoid windows, doors, automatic doors, rotating equipment, HVAC airflow, fans, moving machinery, vibrating fixtures, and direct view to public corridors or outdoor areas
FAQ
How is the RZ048-10A different from the 5A model?
The 10A model has higher verified AC load ratings. Both models use 100-265 VAC input, neutral-required wiring, the same recessed RZ048 ceiling form, and the same microwave sensing platform.
Does the RZ048-10A need a neutral wire?
Yes. The AC wiring diagram requires White to Neutral, Red to Load, and Black to Live.
What loads can the 10A model control?
The manual lists 1000 W / 110 VAC and 2200 W / 220 VAC for incandescent or halogen loads, and 500 W / 110 VAC and 1000 W / 220 VAC for fluorescent, ballast, or LED loads.
Can microwave sensing detect through glass or partitions?
Yes. The manual states that microwave sensing can detect through most plastics, glass, and thin partitions, while metal blocks detection. Placement and sensitivity should be adjusted accordingly.
How can nuisance triggering be reduced?
Reduce sensitivity to Low or relocate the sensor to avoid doors, windows, adjacent spaces, moving machinery, HVAC airflow, fans, vibrating fixtures, and large metal or reflective surfaces.
What time delay settings are available?
Time delay settings are 15 s, 30 s, 1 min, 3 min, 5 min, 10 min, and 30 min. The manual default is 1 min.



Anmeldelser