Product video
Ceiling Mount Motion Sensor
BS036
$10.00
BS036 is a ceiling mount occupancy sensor switch with a 360-degree PIR Motion sensor covering a 12m detection distance. Users can adjust time delay(10s~7 mins), sensor sensitivity, and light sensor(3-2000LUX) settings on the sensor.
āđāļĄāđāđāļāđāļŠāļīāđāļāļāļĩāđāļāļļāļāļāļģāļĨāļąāļāļĄāļāļāļŦāļēāđāļāđāđāļŦāļĄ? āļāļđāļāļĨāļļāđāļĄāļāļĨāļīāļāļ āļąāļāļāđāļāļāļāđāļĢāļē:
- āļŠāļ§āļīāļāļāđāđāļāļāđāļāļāļĢāđāļāļĢāļ§āļāļāļąāļāļāļ§āļēāļĄāđāļāļĨāļ·āđāļāļāđāļŦāļ§: āđāļāļāđāļāļīāļāļŠāļēāļĒ/āđāļĢāđāļŠāļēāļĒ āļŠāļģāļŦāļĢāļąāļāļāļēāļĢāļāļīāļāļāļąāđāļāļĄāļēāļāļĢāļāļēāļ US/UK/EU āļāļĢāđāļāļĄāļĢāļ°āļāļāļāļ§āļāļāļļāļĄāļāđāļ§āļĒāļĄāļ·āļ (Manual Override)
- āđāļāļāđāļāļāļĢāđāļāļĢāļ§āļāļāļąāļāļāļēāļĢāđāļāļīāļ-āļāļīāļāđāļāļāļēāļĄāļāļēāļĢāđāļāļĨāļ·āđāļāļāđāļŦāļ§āđāļĨāļ°āļŠāļ āļēāļ§āļ°āļŦāđāļāļ (Occupancy/Vacancy sensors)
- āđāļāļāđāļāļāļĢāđāļāļĢāļ§āļāļāļąāļāļāļ§āļēāļĄāđāļāļĨāļ·āđāļāļāđāļŦāļ§āđāļāļāđāļēāđāļĢāļāļāļąāļāļāđāļģ DC
āļāļĢāļķāļāļĐāļēāļāļđāđāđāļāļĩāđāļĒāļ§āļāļēāļ
āļāļąāļāļŠāđāļāļĢāļ§āļāđāļĢāđāļ§: āļĄāļĩāļŠāļīāļāļāđāļēāđāļāļŠāļāđāļāļ 99%
āļāļĨāļļāđāļĄāļāļĨāļīāļāļ āļąāļāļāđāļāļģāļāļēāļāļāđāļ§āļĒāļāļēāļĢāļāļĢāļ§āļāļāļąāļāļāļ§āļēāļĄāđāļāļĨāļ·āđāļāļāđāļŦāļ§āļāļĢāļāļ§āļāļāļĢ
āļŠāļāļāļāļēāļĄāļāđāļāļĄāļđāļĨ āļŠāļģāļŦāļĢāļąāļāļāļģāļŠāļąāđāļāļāļ·āđāļ ODM/OEM āļāļģāļāļ§āļāļĄāļēāļ

Ceiling Mount Motion Sensor
BS036 is a ceiling mount occupancy sensor switch with a 360-degree PIR Motion sensor covering a 12m detection distance.
Users can adjust time delay(10s~7 mins), sensor sensitivity, and light sensor(3-2000LUX) settings on the sensor.
āļāļļāļāļŠāļĄāļāļąāļāļī āļāļĢāļ°āđāļĒāļāļāđ āļŠāđāļāļāļŠāļīāļāļāđāļē

āļāļļāļāļŠāļĄāļāļąāļāļīāđāļĨāļ°āļāļĢāļ°āđāļĒāļāļāđ
- Premium PIR Motion Sensor: 3 detectors for triple overlapping coverage to catch even small movements. Widely used on LED lights, compact fluorescent lamps, incandescent lamps, ceiling lights, exhaust fans
- Light Sensor: 3~2000LUX adjustable. The ceiling occupancy sensor can be adjusted to work the entire day or only work at night.
- Time Delay: 10sec-7min adjustable. The delay time controls how long the light stays on once the ceiling motion sensor gets triggered.
- Detection Range/Sensitivity: 3-12m adjustable and can be adjusted according to your demand. The ceiling occupancy sensor fits both small and large rooms.
- Features
Power Sourcing
110V-240VAC
Detection Range
360°
Detection Distance
3~12m (<24â) adjustable
Working Humidity
<93%RH
Ambient Light
3-2000LUX (Adjustable)
Time-Delay
10sec ~ 7mins
Power Consumption
0.45W (work), 0.1W (idle)
Installing Height
2.2m~4m
Detection motion speed
0.6~1.5m/s
Rated Load
1200W (incandescent lamp), 300W (energy-saving lamp)
Versatile Applications

Bathroom
Occupancy sensor with light sensor enabled is the ideal mode for bathroom usage, especially when you need to use it at night. Manual ON mode can be suitable for long showers.

Garage
Walk in and out of your home garage without the need to reach the light switch with an occupancy sensor switch. Enable daylight sensing to save more energy in the daytime.

Laundry Room
Enjoy the automatic lighting turned on and off for you when arm-full with piles of laundry to wash or clean clothes to take away.

Kitchen
Place an occupancy sensor switch at the entrance and enjoy the automatic lighting while you’re busy cooking and preparing food for your family.

Hallway
Occupancy/vacancy sensor switches can reduce the hours of lighting used by approximately 53% on dark hallways in your basement.

Breakroom
Occupancy sensors can reduce energy waste by 39% and increase energy-saving up to 17% with a 20-minute time delay for breakrooms.

Private Office
Rayzeek motion sensor switches provide max flexibility for office use cases. Occurpnay, vacancy or manual mode, your office, your call.

Conference Room
Vacancy switch with manual override feature is perfect for conference rooms where it’s not frequently used and requires manual turn on and off for presentations.
āđāļŦāļĨāđāļāļāđāļāļĄāļđāļĨ

Expand Your Motion Sensors
View all our energy-saving products on motion sensors
āļāļļāļāļāļēāļāļāļ°āļāļ·āđāļāļāļāļ…
-

Occupancy / Vacancy / Manual Motion Sensor Switch, Neutral Required, EU
RZ022-5A- Occupancy, Vacancy, ON/OFF mode
- 100~265V, 5A
- āļāļģāđāļāđāļāļāđāļāļāđāļāđāļŠāļēāļĒāļŠāļēāļĒāļāļīāļ§āļāļĢāļąāļĨ
- Fits the European round backbox
-

āđāļāļāđāļāļāļĢāđāļāļĢāļ§āļāļāļąāļāļāļ§āļēāļĄāđāļāļĨāļ·āđāļāļāđāļŦāļ§āļāļāļīāļāļāļīāļāđāļāļāļēāļāđāļāđāđāļĢāļāļāļąāļāđāļāļāđāļēāļŠāļēāļĒāļŠāđāļ
RZ036-5A- āđāļŦāļĄāļāļāļēāļĢāļāļģāļāļēāļāđāļĄāļ·āđāļāļĄāļĩāļāļāļāļĒāļđāđ (Occupancy mode)
- 100~265V, 5A
- āļāļģāđāļāđāļāļāđāļāļāđāļāđāļŠāļēāļĒāļŠāļēāļĒāļāļīāļ§āļāļĢāļąāļĨ
- 1,600 āļāļēāļĢāļēāļāļāļļāļ
-

āļŠāļ§āļīāļāļāđāđāļāļāđāļāļāļĢāđāļāļĢāļ§āļāļāļąāļāļāļ§āļēāļĄāđāļāļĨāļ·āđāļāļāđāļŦāļ§ āđāļŦāļĄāļ Occupancy / Vacancy / Manual āļāļģāđāļāđāļāļāđāļāļāđāļāđāļŠāļēāļĒāļāļīāļ§āļāļĢāļąāļĨ āļāļĨāļąāđāļ UK
RZ023-5A- Occupancy, Vacancy, ON/OFF mode
- 100~265V, 5A
- āļāļģāđāļāđāļāļāđāļāļāđāļāđāļŠāļēāļĒāļŠāļēāļĒāļāļīāļ§āļāļĢāļąāļĨ
- Fits the UK square pattress box
-

Occupancy / Vacancy / Manual Motion Sensor Switch, No Neutral Required, UL Listed
RZ021-5A-G- Occupancy, Vacancy, ON/OFF mode
- 120V, 5A
- Ground Wire Required
- Fits the US 1-Gang wall box





āļĢāļĩāļ§āļīāļ§
āļĒāļąāļāđāļĄāđāļĄāļĩāļāļāļ§āļīāļāļēāļĢāļāđ