BLOGG

What is Discomfort Glare

Horace He

Senast uppdaterad: 26 december 2023

What is Discomfort Glare

Discomfort glare is the visual discomfort experienced when individuals are exposed to light sources or luminaires that have a higher luminance than their eyes can adapt to. This type of glare can cause immediate discomfort or become apparent over time. Several factors influence the degree of discomfort glare, including the luminance and size of the glare source, the background luminance against which the glare source is viewed, and the position of the glare source in relation to the line of sight.

To mitigate discomfort glare in lighting planning, you need to consider the relationship between a luminaire’s luminance and the background luminance. Open luminaires, especially those designed for compact and intensive light sources with high luminous flux, often contribute to discomfort glare. This can be caused by the light source itself or a mirror image in polished reflectors or working materials. To reduce discomfort glare, it is recommended to use matt reflectors and large-area luminaires.

Du kanske också är intresserad av

  • Spänning: 2 AAA-batterier
  • Dag-/nattläge
  • Tidsfördröjning: 15 min, 30 min, 1 tim (standard), 2 tim
  • Takmonterad PIR-närvarosensor med reläutgång för potentialfri kontakt
  • 12/24VDC eller 12/24VAC lågspänningsförsörjning
  • Isolerade reläkontakter (COM, NO och NC) för styringångar till EMS, VVS och fastighetsautomation
RZ048 infälld mikrovågsrörelsesensor för tak produktbild
  • Lågspänningsdriven (DC) infälld mikrovågsrörelsevakt för tak montering
  • 12 VDC / 24 VDC-ingång med ett driftsområde på 10–30 VDC
  • Maximal arbetsström på 10A med inställbar tidsfördröjning, Lux-tröskelvärde och känslighet
RZ048 infälld mikrovågsrörelsesensor för tak produktbild
  • Infälld mikrovågsrörelsevakt för tak avsedd för högre belastning
  • 100–265 VAC nätspänningsingång, 10A-modell
  • 5,8 GHz mikrovågsdetektering med inställbar tidsfördröjning, Lux-tröskelvärde och känslighet
RZ048 infälld mikrovågsrörelsesensor för tak produktbild
  • Infälld takmonterad mikrovågsrörelsesensorbrytare
  • 100–265 VAC nätspänningsingång, 5A-modell
  • 5,8 GHz mikrovågsdetektering med inställbar tidsfördröjning, Lux-tröskelvärde och känslighet
  • Takmonterad RZ037 PIR-närvarosensordimmer för 220V-ström
  • 3A maximal arbetsström med 660W märkeffekt
  • LUX-knapp styr ljussensor PÅ/AV och användarinställd dimringsnivå
  • Takmonterad RZ037 PIR-närvarosensordimmer för 110V-ström
  • 3A maximal arbetsström med 330W märkeffekt
  • LUX-knapp styr ljussensor PÅ/AV och användarinställd dimringsnivå
RZ047 takmonterad strömbrytare med mikrovågsrörelsesensor
  • Lågspännings-DC takmonterad mikrovågsrörelsesensorbrytare
  • 12 VDC / 24 VDC-ingång med ett driftsområde på 10–30 VDC
  • Maximal arbetsström på 10A med inställbar tidsfördröjning, Lux-tröskelvärde och känslighet
RZ047 takmonterad strömbrytare med mikrovågsrörelsesensor
  • Takmonterad mikrovågsrörelsesensorbrytare för högre belastning
  • 100–265 VAC nätspänningsingång, 10A-modell
  • 5,8 GHz mikrovågsdetektering med inställbar tidsfördröjning, Lux-tröskelvärde och känslighet
RZ047 takmonterad strömbrytare med mikrovågsrörelsesensor
  • Takmonterad mikrovågsrörelsesensorbrytare
  • 100–265 VAC nätspänningsingång, 5A-modell
  • 5,8 GHz mikrovågsdetektering med inställbar tidsfördröjning, Lux-tröskelvärde och känslighet
RZ038 infälld PIR-rörelsesensor för tak, topp- och sidovy
  • Lågspännings-DC infälld takmonterad PIR-rörelsesensorströmbrytare
  • 12 VDC / 24 VDC-ingång med ett driftsområde på 10–30 VDC
  • Max arbetsström 10A med inställbar tidsfördröjning, Lux-tröskelvärde och känslighet
RZ038 infälld PIR-rörelsesensor för tak, frontvy
  • Infälld takmonterad PIR-rörelsesensorströmbrytare för högre belastning
  • 100–265 VAC nätspänningsingång, 10A-modell
  • 360-graders detektering med inställbar tidsfördröjning, Lux-tröskelvärde och känslighet
RZ038 infälld PIR-rörelsesensor för tak, frontvy
  • Infälld takmonterad PIR-rörelsesensorströmbrytare
  • 100–265 VAC nätspänningsingång, 5A-modell
  • 360-graders detektering med inställbar tidsfördröjning, Lux-tröskelvärde och känslighet
RZ040 trådlös strömbrytare och mottagarsats
  • Trådlöst strömbrytar- och mottagarkit för inomhus belysningsstyrning ON/OFF
  • 100-230VAC, 50/60Hz-mottagare med 5A märkström
  • CR2032-driven trådlös strömbrytare med 2,4GHz-kommunikation
  • Närvaro (Auto-ON/Auto-OFF)
  • 12–24V DC (10–30VDC), upp till 10A
  • 360° täckning, 8–12 m diameter
  • Tidsfördröjning 15 s–30 min
  • Ljussensor Off/15/25/35 Lux
  • Hög/Låg känslighet
  • Automatisk På/Automatisk Av närvaroläge
  • 100–265V AC, 10A (nolla krävs)
  • 360° täckning; 8–12 m detekteringsdiameter
  • Tidsfördröjning 15 s–30 min; Lux AV/15/25/35; Känslighet Hög/Låg
  • Automatisk På/Automatisk Av närvaroläge
  • 100–265V AC, 5A (nolla krävs)
  • 360° täckning; 8–12 m detekteringsdiameter
  • Tidsfördröjning 15 s–30 min; Lux AV/15/25/35; Känslighet Hög/Låg

In addition, increasing the luminosity on the room walls and ceiling can help minimize discomfort glare. This can be achieved by equipping luminaires with a certain amount of uplight, installing luminaires closer to the room’s walls, or separately lighting the walls. However, excessively bright walls in relation to the vision object can lead to adaptation problems. Therefore, the luminosity of room surfaces should be adjusted according to the visual conditions and limited in accordance with the provided instructions on luminance distribution and limitations.

Letar du efter rörelsestyrda energisparande lösningar?

Kontakta oss för kompletta PIR-rörelsesensorer, rörelseaktiverade energisparprodukter, rörelsesensorbrytare och kommersiella lösningar för närvaro/frånvaro (Occupancy/Vacancy).

Vanliga frågor

How Do You Prevent Glare in Lighting Design

Avoid using shiny metals and metallic paints in lighting design. Additionally, ensure that television sets and computer monitors are positioned away from light sources that can cause reflected glare. To prevent glare, it is also recommended to incorporate multiple layers of light in the space, including ambient light, task lights, and a subtle touch of accent lighting, as long as the accents do not create direct glare.

Varför är bländning så farligt eller besvärligt på natten

Nattlig bländning är ett problem eftersom det orsakas av både starka och svaga ljus. När man försöker se något i närvaron av ett starkt ljus kan det få ögonen att kisa och tåras. Å andra sidan kan svag belysning försämra synen genom att minska kontrasten i bilderna.

Vilken typ av glödlampa minskar bländning

Som det mest energieffektiva alternativet på marknaden är LED-lampor och armaturelement mycket effektiva för att minska bländning och förbättra den visuella tydligheten i ett rum.

What Is the Difference Between Discomfort Glare and Disability Glare

Discomfort Glare is the term used to describe the feeling of discomfort caused by excessive brightness, such as when standing on a snow field under bright sunlight. On the other hand, Disability Glare refers to a situation where visibility of a specific object is reduced due to the presence of a light source in a different area.

Why Do I See Starbursts Around Lights

Starbursts around lights, which are characterized by concentric rays or fine filaments radiating from bright sources, can be attributed to refractive abnormalities in the eye. These starbursts are particularly noticeable during nighttime and can be associated with eye conditions like cataracts or corneal swelling, as well as potential complications arising from eye surgery.

Varför besvärar bländning mina ögon

Bländning kan vara besvärande för ögonen eftersom den kan orsaka obehag och påverka din syn. När det föreligger bländning sprids ljuset inuti ögat, vilket gör det svårt att se skarpa bilder. Det är viktigt att notera att avaktivering av bländning faktiskt kan förvärra kontrastförlusten, särskilt i dämpade miljöer snarare än ljusa.

What Is Difference Between Light and Glare

Glare occurs when light is excessively bright, resulting in decreased visibility rather than improved visibility. Additionally, glare can occur due to specific vision issues that cause the light entering the eye to scatter instead of being properly focused.

Do LED Lights Cause Glare

LED lights have the potential to cause glare and hinder visibility. However, selecting the appropriate LED light can effectively minimize this issue and greatly enhance visibility.