It uses advanced passive infrared sensors(PIR)and MCU control technology to detect motion, automatically turning lights on and off. The switch offers easy and accurate adjustment of the Time Delay Detection Range,Light Sensor value and Operating Mode Occupancy/Vacancy/On-Off), making it simple to customize for any setting. With improved stability compared to traditional motion sensors the RZ022-5A-S provides a reliable energy-efficient and cost-effective lighting solution for homes offices and commercial spaces.
Dowiedz się więcej

Główne cechy produktu

  • Line voltage, 5A current rating. EU standard.
  • Przewód neutralny/uziemiający nie jest wymagany.
  • Tryb obecności, tryb pustego pomieszczenia z ręcznym sterowaniem

Szybka dostawa: 99% w magazynie

Pełna linia produktów aktywowanych ruchem

Wyślij zapytanie dla hurtowych zamówień ODM/OEM

Przełącznik oświetlenia z czujnikiem ruchu

Przełącznik światła z czujnikiem ruchu, znany również jako przełącznik z czujnikiem światła lub przełącznik z czujnikiem obecności, to aktywowany ruchem przełącznik, który automatycznie steruje oświetleniem. Przełącznik z czujnikiem ruchu włącza światło, gdy wbudowany czujnik ruchu wykryje Twoją obecność w pomieszczeniu, i wyłącza światło, gdy pomieszczenie jest puste.

To wygodny sposób na wprowadzenie automatyzacji oświetlenia w domu, zapewniający bezdotykową obsługę światła. Co więcej, przełączniki z czujnikiem ruchu pomagają właścicielom domów łatwo oszczędzać energię, zapobiegając marnowaniu prądu przez pozostawione włączone światła.

rz022 eu occupancy vacancy sensor switch side

Wszechstronny tryb czujnika 3 w 1

RZ022-5A-S motion sensor light switch utilizes PIR(passive infrared) technology with advanced microcontrollers for superior motion detection sensitivity and performance. RZ022 sensor switch includes three working modes:

  • Occupancy Mode: The light automatically turns on and off by the motion sensor. (Auto-on/Auto-off Mode)
  • Vacancy Mode: Press the button to manually turn on the light and the light automatically turns off. (Manual-on/Auto-off Mode)
  • ON/OFF Mode: Perform exactly like a single pole light switch. You can manually keep the light on or off. (Manual Override Mode)
rz023 occupancy vacancy sensor switch without cover

Low-Profile & Sleek Design

The low-profile, sleek, minimalist design allows the RZ022 motion sensor switch to fit in every style of decor and blend in your home seamlessly. Besides the aesthetics part, our switch design is extremely practical as well. All adjustment and operation process is achieved by pressing the two buttons on the panel. The switch does not contain any toggles or dials for adjusting settings or switching modes. This makes the RZ022-5A-S motion sensor switch look modern, neat, and slim on your wall.

Stworzony dla każdego domu

The RZ022-5A-S is an upgrade and direct replacement for regular single-pole light switches in the EU. The 100V-265V voltage range works well in homes and offices and the 5A high current rating is competent for daily uses loading multiple fixtures.

The 2-wire, required RZ022-5A-S is perfect for retrofit projects for old houses that only have hot wire available in their wall boxes. No extra re-wiring cost.

Unikalna funkcja Tryb ON/OFF

Jedną z istotnych wad wymiany włączników na przełączniki z czujnikiem ruchu jest częściowa utrata możliwości ręcznego sterowania oświetleniem. Nie można pozostawić światła włączonego tak, jak przy użyciu tradycyjnego przełącznika ściennego.

Połączenie zalet obu rozwiązań

Rayzeek wprowadza unikalny tryb ON/OFF, który umożliwia użytkownikom pozostawienie obciążenia trwale włączonego (ON) lub wyłączonego (OFF), tak jak w standardowym włączniku światła. To niezwykle wygodne rozwiązanie pozwala płynnie przełączać się między trybem detekcji a trybem ręcznym za pomocą jednego dotknięcia.

Pożegnaj codzienne uciążliwości.

Zwierzęta aktywujące światło w nocy

Psy i koty są aktywne nocą, co może powodować częste uruchamianie oświetlenia z czujnikiem ruchu. Wynika to z ich naturalnych zachowań. Większość przełączników z czujnikiem ruchu nie posiada funkcji ignorowania zwierząt, dlatego fałszywe załączenia w nocy bywają uciążliwe.

Wybierz tryb pustki lub tryb OFF, w szczególności w pralni lub kuchni, gdzie zwierzęta domowe najczęściej przebywają.

Relaksująca, długa kąpiel

Średnio spędzamy pod prysznicem co najmniej 8 minut. Podczas relaksującej kąpieli wieczornej światło może nieoczekiwanie zgasnąć, jeśli czujnik nie wykryje obecności w strefie kąpielowej. Może to być nieprzyjemne doświadczenie, które psuje nastrój.

Uruchom tryb ON, aby światło pozostało włączone przez cały czas trwania prysznica. Ciesz się gorącą i relaksującą kąpielą tak długo, jak chcesz.

Oświetlenie w pokoju dziecięcym

Przełącznik z czujnikiem pustki jest stosowany w sypialniach, aby zmniejszyć marnotrawstwo energii elektrycznej spowodowane światłem pozostawionym przez dzieci. Czujniki obecności nie są odpowiednie, ponieważ mogą włączać światło w nocy i wybudzać dzieci, chociaż w ciągu dnia pozostają wygodniejszym rozwiązaniem.

Teraz możesz korzystać z trybu czujnika obecności w pokoju dziecka przez cały dzień. Kiedy nadchodzi pora spania, naciśnij przycisk OFF, aby zachować wyłączone światło przez całą noc.

Light False on in Empty Spaces

A fixed heat source(HVAC or hot wind) or even mirror reflection may send false positive IR signals that keep the light on when the space is unoccupied. Most of the time, it’s impossible to relocate the sensor’s position or the heat source as they’re fixed.

When the PIR sensor constantly detects signals and is falsely triggered, select OFF Mode to bypass motion detection

False off With People in the Room

Lights might falsely turn off if the sensor fails to detect the presence of people, e.g., the room is large, has obstacles blocking the IR signal, or fine motion activities such as reading or typing. It’s frustrating to repeatedly re-activate lights by moving your body.

When we need to permanently keep the light ON, enter ON mode by tapping the small button and exit without losing previous settings.

Funkcje, zalety, specyfikacja

The ultimate energy-saving & lighting automation solution – switch from Auto ON/Auto OFF, Manal ON/Auto OFF, and Manal ON/Manual OFF operating mode for your multi-purpose rooms.

rz022 motion sensor switch manual instruction

Funkcje i zalety

  • Occupancy, Vacancy, Manual ON/OFF mode 3 in 1
  • Exclusive ON/OFF mode allows the sensor switch to work the same as a standard light switch
  • Time delay options: 15s, 1 min, 3 mins, 5 mins, 15 mins, 30 mins
  • Enable ambient light sensor to keep lights off when there is ample natural light
  • Low and high sensitivity adjustable
  • Adjust settings by tapping buttons without removing the switch plate
  • Magnetic latching relay provides better performance
  • Made of fire-resistant materials for your safety
  • RoHS, CE, FCC certified
Cechy

Tryb czujnika

Vacancy mode, Occupancy mode, Manual ON/OFF mode

Opóźnienie czasowe

15 s, 1 min(default), 3 mins, 5 mins, 15 mins, 30 mins

Czujnik światła

Wył., 15 Lux, 25 Lux (domyślnie), 35 Lux

Czułość czujnika

Low Sensitivity, High Sensitivity

Working Conditions

Źródło zasilania

100 VAC ~ 265 VAC

Częstotliwość zasilania

50 / 60Hz

Installation Height

1.2 m ~ 1.6 m

Wilgotność robocza

< 93%RH

Temperatura pracy

-20 ~ +40℃

Detection Capability

Zasięg detekcji

7 m ~ 10 m (<27℃)

Zasięg detekcji

< 150°

Detection Speed

0.6 ~ 1.5m/s

Bulb Compatibility

Fluorescent / Ballast / LED

500 W / 220 VAC

Incandescent / Halogen

1100 W / 220 VAC

The Ideal Repalcement

The Rayzeek RZ022 motion sensor switch is designed to fit in the European standard round wall switch box and replace light switches in the EU region. With a wide 100V-265V voltage range, RZ022 motion sensor switches are the ideal replacement motion-activated switches for European markets.

rz022 occupancy vacancy sensor switch dimension

RZ022-5A-S

  • 5A Load: Ideal for daily home and commercial use cases for controlling lights
  • 2-Wire Wiring: Hot Wire, Load Wire
eu-box

European Standard Switch

RZ022 motion sensor switch is designed for replacing light switches in the EU region where the round electrical switch boxes are commonly used. Also suitable for regions using the European standard switch boxes:

  • Austria
  • Germany
  • France

Versatile Applications

Rayzeek RZ022 motion sensor switch is the ultimate solution for automating your home lighting. It can act as an occupancy sensor, vacancy sensor, or a standard light switch to suit the diverse needs of every space. Simply upgrade all your light switches with RZ022 without a second thought because you can always change it to a manual ON/OFF switch when needed.

Bathroom

Occupancy sensor with light sensor enabled is the ideal mode for bathroom usage, especially when you need to use it at night. Manual ON mode can be suitable for long showers.

Garage

Walk in and out of your home garage without the need to reach the light switch with an occupancy sensor switch. Enable daylight sensing to save more energy in the daytime.

Laundry Room

Enjoy the automatic lighting turned on and off for you when arm-full with piles of laundry to wash or clean clothes to take away.

Kuchnia

Place an occupancy sensor switch at the entrance and enjoy the automatic lighting while you’re busy cooking and preparing food for your family.

Hallway

Occupancy/vacancy sensor switches can reduce the hours of lighting used by approximately 53% on dark hallways in your basement.

Breakroom

Occupancy sensors can reduce energy waste by 39% and increase energy-saving up to 17% with a 20-minute time delay for breakrooms.

Gabinet prywatny

Rayzeek motion sensor switches provide max flexibility for office use cases. Occurpnay, vacancy or manual mode, your office, your call.

Sala konferencyjna

Vacancy switch with manual override feature is perfect for conference rooms where it’s not frequently used and requires manual turn on and off for presentations.

Filmy

Fire Resistance Testing – RZ022

Load Testing

Zasoby

EU rz022 occupancy sensor c2a

Rozszerz swój system czujników ruchu

Zobacz wszystkie nasze energooszczędne czujniki ruchu

Opinie

Na razie nie ma opinii o produkcie.

Napisz pierwszą opinię o „Occupancy / Vacancy / Manual Motion Sensor Switch, No Neutral/Ground Required, EU”

Może spodoba się również…

Polish