Product video
Sufitowy czujnik ruchu i obecności sieciowy
RZ036-5A
$15.00
RZ036-5A is a line voltage passive infrared(PIR) technology ceiling mount occupancy sensor that is commonly used as an automatic light switch or fan switch for commercial and residential applications.
The line voltage ceiling mount occupancy sensor RZ036-5a does not require power packs, they are directly installed and mounted on the ceiling. Rayzeek 036-5A ceiling mounted occupancy sensors offer detection coverage up to 1600 sq ft. with a 5A high current rating which is capable of controlling multiple lighting fixtures and exhaust fans.
Main Features:
- Automatyczny tryb obecności (Auto-ON/Auto-OFF)
- 360-degree detection coverage up to 1600 sq ft.
- 100V ~ 265V for residential and commercial application
- Time delay, light sensor Lux value and sensitivity adjustment
- Certification: FCC, RoHS certified
Główne cechy produktu
- Napięcie sieciowe, prąd znamionowy 5A
- Neutral required.
- Ceiling Mount Occupancy Sensor, PIR motion sensor
Nie tego szukasz? Zobacz nasze portfolio:
Skonsultuj się z ekspertem
Szybka dostawa: 99% w magazynie
Pełna linia produktów aktywowanych ruchem
Wyślij zapytanie dla hurtowych zamówień ODM/OEM

Sufitowy czujnik obecności
The RZ036 ceiling mount occupancy sensor, also referred to as a ceiling mount motion sensor or motion detector, utilizes advanced passive infrared(PIR) motion sensor technology to provide our users a better motion detecting performance.
The RZ036-5A model offers a 5A current rating which is adequate for most residential lighting usage, such as hallway lighting or control fans.

Łatwa regulacja
Rayzeek projektuje czujniki ruchu z myślą o wygodzie użytkowania. Użytkownicy mogą bez trudu zmienić ustawienia za pomocą przycisków i kontrolek świetlnych bez użycia narzędzi. Śrubokręt nie jest już potrzebny.
Użytkownicy mogą regulować czułość czujnika od niskiej do wysokiej, opóźnienie czasowe od 30 s do 30 min, a wartość światła otoczenia od 15 do 35 LUX lub wyłączyć tę funkcję, aby czujnik działał w ciągu dnia.

Lepszy pod każdym względem
Sufitowe czujniki obecności z serii RZ036 zapewniają 360-stopniowe pole widzenia i szeroki zasięg detekcji do 1600 stóp kwadratowych, umożliwiając wykrywanie ruchu z dowolnego miejsca w pomieszczeniu.
Niskoprofilowa i elegancka konstrukcja sprawia, że czujniki ruchu RZ036 idealnie komponują się z każdym sufitem, niezależnie od wystroju wnętrza. Czujnik obecności pozostaje dyskretny, zapewniając optymalne wykrywanie ruchu.
Funkcje, zalety, specyfikacja
Sufitowy czujnik obecności RZ036 to uniwersalne rozwiązanie do montażu sufitowego, optymalne dla niemal każdego zastosowania mieszkalnego i komercyjnego.

Funkcje i zalety
- Zaawansowana technologia PIR z jednym wbudowanym detektorem zapewnia wysoki poziom czułości i precyzję działania.
- Wykonany z wysoce bezpiecznego materiału ogniotrwałego.
- Wbudowane przekaźniki zatrzaskowe magnetyczne oferują wyższą wydajność w porównaniu z tradycyjnymi przekaźnikami.
- Regulowane ustawienie opóźnienia czasowego: 15 s, 30 s, 1 min, 3 min, 5 min, 10 min oraz 30 min.
- Regulowana wartość czujnika światła: WYŁ., 15 Lux, 25 Lux oraz 35 Lux
- Regulowane ustawienie czułości (zasięgu detekcji) od niskiej do wysokiej.
- Certyfikaty FCC, CE, RoHS.
- Cechy
Tryb czujnika
Tryb obecności, tryb obecności bez czujnika światła
Opóźnienie czasowe
15 s, 30s, 1 min(default), 3 min, 5 min, 10 min, 30 min
Czujnik światła
Wył., 15 Lux, 25 Lux (domyślnie), 35 Lux
Czułość czujnika
Low Sensitivity, High Sensitivity
- Working Conditions
Źródło zasilania
110 VAC ~ 265 VAC
Częstotliwość zasilania
50 / 60Hz
Installation Height
2.6 m ~ 3.5 m
Wilgotność robocza
< 93%RH
Temperatura pracy
-10 ~ +40℃
- Detection Capability
Zasięg detekcji
12 m ~ 18 m (<27℃)
Zasięg detekcji
360°
Detection Speed
0.6 ~ 1.5m/s
- Bulb Compatibility
Fluorescent / Ballast / LED
500 W / 220 VAC
Incandescent / Halogen
1100 W / 220 VAC
Versatile Applications
The RZ036 is the ideal ceiling-mounted occupancy sensor solution for 100V ~265V home applications and commercial projects. Perfect for frequently visited spaces, such as public bathrooms, hallways, garages, open offices, breakrooms, stairwells, or corridors.

Bathroom
Occupancy sensor with light sensor enabled is the ideal mode for bathroom usage, especially when you need to use it at night. Manual ON mode can be suitable for long showers.

Garage
Walk in and out of your home garage without the need to reach the light switch with an occupancy sensor switch. Enable daylight sensing to save more energy in the daytime.

Laundry Room
Enjoy the automatic lighting turned on and off for you when arm-full with piles of laundry to wash or clean clothes to take away.

Kuchnia
Place an occupancy sensor switch at the entrance and enjoy the automatic lighting while you’re busy cooking and preparing food for your family.

Hallway
Occupancy/vacancy sensor switches can reduce the hours of lighting used by approximately 53% on dark hallways in your basement.

Breakroom
Occupancy sensors can reduce energy waste by 39% and increase energy-saving up to 17% with a 20-minute time delay for breakrooms.

Gabinet prywatny
Rayzeek motion sensor switches provide max flexibility for office use cases. Occurpnay, vacancy or manual mode, your office, your call.

Sala konferencyjna
Vacancy switch with manual override feature is perfect for conference rooms where it’s not frequently used and requires manual turn on and off for presentations.
Filmy
Montaż RZ036
Instrukcja obsługi RZ036
Fire Resistance Testing – RZ036
Load Testing
Zasoby

Rozszerz swój system czujników ruchu
2 opinie dla Ceiling Mount Line Voltage Occupancy Motion Sensor
Może spodoba się również…
-

Przełącznik z czujnikiem ruchu (tryb zajętości / pustostanu / ręczny), niewymagany przewód neutralny, certyfikat UL
RZ021-5A-G- Tryb zajętości, pustostanu, WŁ./WYŁ.
- 120V, 5A
- Wymagany przewód uziemiający
- Pasuje do amerykańskiej puszkowej ściennej 1-Gang
-

Przełącznik z czujnikiem ruchu (Occupancy / Vacancy / Manual), wymagana żyła neutralna, EU
RZ022-5A- Tryb zajętości, pustostanu, WŁ./WYŁ.
- 100~265V, 5A
- Wymagany przewód neutralny
- Pasuje do europejskiej puszkowej obudowy okrągłej
-

Sufitowy czujnik ruchu i obecności sieciowy
RZ036-10A- Tryb obecności (Occupancy)
- 100~265V, 10A
- Wymagany przewód neutralny
- 1600 sq ft
-

Przełącznik z czujnikiem ruchu z trybami zajętości / pustostanu / ręcznym, wymagany przewód neutralny, UK
RZ023-5A- Tryb zajętości, pustostanu, WŁ./WYŁ.
- 100~265V, 5A
- Wymagany przewód neutralny
- Pasuje do brytyjskiej kwadratowej puszki montażowej




Tim.K –
The sensor works great so far on our project.
Rob –
It has a low profile look with style, matches our ceiling decor. Exactly what we need.