RZ048-5A 360도 천장 매립형 마이크로웨이브 동작 감지 센서 스위치
RZ048-5A
RZ048-5A is a 100-265 VAC recessed ceiling microwave motion sensor switch for automatic indoor lighting control.
The 5A model uses high-frequency microwave Doppler sensing, neutral-required AC wiring, adjustable time delay, selectable Lux threshold, and high/low sensitivity in the RZ048 recessed ceiling form.
- 100-265 VAC 라인 전압 입력, 5A 모델
- 360도 범위를 감지하는 5.8 GHz 마이크로웨이브 감지
- 수동 조건에서 8-12 m 감지 지름
- 시간 지연: 15초~30분
- Lux 설정: Off, 15, 25 또는 35 Lux
제품 주요 특징
- 5A AC 모델: 100-265 VAC recessed ceiling microwave sensor switch for verified RZ048-5A load ratings.
- 마이크로웨이브 감지: 360도 천장 감지 범위를 제공하는 5.8 GHz 도플러 감지.
- Recessed mounting: Screw mount or spring clip mount with an 82-90 mm circular ceiling cutout.
찾으시는 제품이 아닌가요? 제품 포트폴리오 보기:
전문가 상담

5A Recessed Ceiling Microwave Sensing For Automatic Lighting
The RZ048-5A is a recessed ceiling-mounted microwave motion sensor switch for indoor automatic lighting control where a low-profile ceiling form is preferred over a wall switch.
100-265 VAC 라이브, 중성선 및 부하 배선을 사용하며, 설치 후 푸시 버튼으로 시간 지연, Lux 임계값 및 고/저 감도를 조절할 수 있습니다.

일상적인 공간을 위한 360도 마이크로웨이브 커버리지
마이크로웨이브 도플러 감지는 유리, 플라스틱, 얇은 칸막이와 같은 다양한 비금속 물질을 통과하여 움직임을 감지할 수 있어, 천장 설치 시 실제 실내 공간 레이아웃을 효과적으로 커버합니다.
동일한 높은 감도로 인해 의도하지 않은 영역 외부의 움직임도 감지될 수 있으므로, 문, 창문, 칸막이, 금속 표면 또는 움직이는 구조물로 인해 오작동이 발생하는 경우 설치자는 감도를 낮추거나 센서 위치를 변경해야 합니다.
기능, 장점, 사양
The RZ048-5A combines 5A AC lighting control, recessed mounting, and 5.8 GHz microwave detection so installers can verify load fit, placement, and setup before ordering.

주요 기능 및 장점
- 5A 라인 전압 제어: Supports 100-265 VAC lighting circuits with the source-backed RZ048-5A load ratings shown in the specifications.
- 5.8 GHz 마이크로웨이브 감지: 고주파 도플러 감지가 움직임을 능동적으로 감지하여 천장 설치형 자동 조명 제어를 제공합니다.
- 매립형 천장 형태: 나사 고정 또는 스프링 클립 설치를 통해 매뉴얼에 명시된 82-90 mm 타공 규격으로 돌출을 최소화한 천장 설치를 지원합니다.
- 360도 천장 감지 범위: Ceiling placement gives broad room coverage with an 8-12 m detection diameter under manual conditions.
- Non-metal material penetration: Microwave detection can pass through many plastics, glass, and thin partitions, while metal blocks detection.
- Adjustable time delay: Choose 15 s, 30 s, 1 min, 3 min, 5 min, 10 min, or 30 min to match room traffic patterns.
- Selectable Lux threshold: Set Off, 15 Lux, 25 Lux, or 35 Lux so the load responds to motion only when the ambient-light condition fits the installation.
- 주요 기능
-
Model
RZ048-5A
Product type
천장 매립형 마이크로웨이브 동작 감지 센서 스위치
Sensor type
High-frequency microwave Doppler (HF)
Microwave frequency
5.8 GHz ISM band
Transmission power
0.4 mW
Time delay
15 s, 30 s, 1 min (default), 3 min, 5 min, 10 min, 30 min
Light sensor level
Off, 15 Lux, 25 Lux (default), 35 Lux
감도
High or Low
Material penetration
Detects through most plastics, glass, and thin partitions; metal blocks detection
- Electrical
-
전원
100 VAC ~ 265 VAC
Power frequency
50/60 Hz
배선
White to Neutral; Red to Load; Black to Live
Power consumption
0.5 W or less standby; 1 W operation
Incandescent / Halogen load
500 W / 110 VAC; 1100 W / 220 VAC
Fluorescent / Ballast / LED load
250 W / 110 VAC; 500 W / 220 VAC
- Detection & Installation
-
Detection diameter
8-12 m
Detection range
360-degree ceiling coverage
Installation height
2.5-5 m
Working temperature
-10 to +40 C
Working humidity
< 93% RH non-condensing
Mounting methods
Screw mount or spring clip mount
Ceiling cutout
82-90 mm circular hole for spring clip mounting
Face diameter
106 mm
Body diameter
78 mm
Height
64 mm overall; 25 mm lower visible section
Metal clearance
Keep at least 1 m from large metal or highly reflective surfaces; do not fully enclose in metal
Installation notes
Avoid windows, doors, automatic doors, rotating equipment, HVAC airflow, fans, moving machinery, vibrating fixtures, and direct view to public corridors or outdoor areas
FAQ
How is the RZ048-5A different from a PIR ceiling sensor?
RZ048 uses high-frequency microwave Doppler sensing. It can detect through many non-metal materials such as glass, plastic, and thin partitions, while metal blocks detection.
Does the RZ048-5A need a neutral wire?
Yes. The AC wiring diagram requires White to Neutral, Red to Load, and Black to Live.
What loads can the 5A model control?
The manual lists 500 W / 110 VAC and 1100 W / 220 VAC for incandescent or halogen loads, and 250 W / 110 VAC and 500 W / 220 VAC for fluorescent, ballast, or LED loads.
What ceiling opening does the spring clip mount need?
The manual lists an 82-90 mm circular ceiling hole for spring clip mounting.
Can microwave sensing trigger from outside the room?
Yes. The manual warns that microwave sensing can detect through glass, doors, or partitions, so sensitivity should be reduced or the sensor relocated if nuisance detection occurs.
Where should the RZ048 be installed?
The manual lists a 2.5-5 m installation height and recommends avoiding windows, doors, automatic doors, rotating equipment, HVAC airflow, fans, moving machinery, vibrating fixtures, and large metal surfaces.