Product video
Interruptor con sensor de movimiento PIR empotrable en techo de 360 grados RZ038-5A
RZ038-5A-SEO
$15.00
RZ038-5A is a 100-265 VAC recessed ceiling PIR motion sensor switch for automatic lighting control in residential and light commercial rooms.
The 5A model uses live, neutral, and load wiring and provides 360-degree PIR coverage, adjustable time delay, selectable Lux threshold, and high/low sensitivity for ceiling-mounted occupancy control.
- Entrada de tensión de red de 100-265 VAC, modelo de 5A
- 360-degree PIR detection with 8-12 m detection diameter
- Temporizador: 15 s a 30 min
- Ajuste de Lux: Desactivado, 15, 25 o 35 Lux
- Neutral wire required for AC wiring
Características destacadas del producto
- Modelo de 5A CA: 100-265 VAC recessed ceiling sensor switch for verified RZ038-5A load ratings.
- Ceiling PIR coverage: 360-degree detection with 8-12 m detection diameter under manual conditions.
- Configuración del instalador: Ajustes mediante botones para la temporización, el umbral de Lux y la sensibilidad alta/baja.
¿No es lo que está buscando? Consulte nuestro catálogo:
Consultar a un experto
Envío rápido: 99% en stock
Gama completa de productos activados por movimiento
Consultar para pedidos al por mayor ODM/OEM

Recessed 5A Ceiling Control For Everyday Lighting Loads
The RZ038-5A is a recessed ceiling-mounted PIR motion sensor switch for automatic lighting control where a discreet ceiling sensor is preferred over a wall switch.
It connects to 100-265 VAC circuits with live, neutral, and load wiring, giving installers adjustable time delay, Lux level, and sensitivity in a compact spring-clip ceiling form.

Lux Control For Rooms With Changing Daylight
The built-in light sensor can hold lighting off when ambient light is above the selected threshold, helping the sensor respond to motion only when the room needs light.
Use the Off, 15 Lux, 25 Lux, or 35 Lux setting to match bathrooms, utility rooms, hallways, or other indoor areas where daylight and occupancy change during the day.
Características, ventajas y especificaciones
The RZ038-5A combines 360-degree PIR detection, 100-265 VAC wiring, and verified 5A load ratings so installers can check coverage, setup, and lighting compatibility before ordering.

Características y ventajas
- Control de tensión de red de 5A: Supports 100-265 VAC lighting circuits with the source-backed RZ038-5A load ratings shown in the specifications.
- 360-degree PIR detection: Ceiling placement gives broad room coverage with an 8-12 m detection diameter when installed within the manual conditions.
- Temporización ajustable: Choose 15 s, 30 s, 1 min, 3 min, 5 min, 10 min, or 30 min to match the room traffic pattern.
- Umbral de Lux seleccionable: Set Off, 15 Lux, 25 Lux, or 35 Lux to control whether motion can switch lights on when ambient light is present.
- Sensibilidad alta/baja: The SENS button lets installers tune detection response for the room layout.
- Spring clip or screw mounting: Mount into an 82-90 mm ceiling cutout or secure to a ceiling/junction box using the documented methods.
- Características
-
Modelo
RZ038-5A
Tipo de producto
Interruptor con sensor de movimiento PIR empotrable en techo
Tipo de sensor
Passive infrared (PIR)
Temporización
15 s, 30 s, 1 min (predeterminado), 3 min, 5 min, 10 min, 30 min
Nivel del sensor de luz
Desactivado, 15 lux, 25 lux (predeterminado), 35 lux
Sensibilidad
Alto o Bajo
Power-up behavior
1-minute warm-up after power is turned on or restored
- Especificaciones eléctricas
-
Fuente de alimentación
100 VAC ~ 265 VAC
Frecuencia de red
50/60 Hz
Cableado
Blanco a neutro; rojo a carga; negro a fase
Carga incandescente / halógena
500 W / 110 VAC; 1100 W / 220 VAC
Carga fluorescente / balasto / LED
250 W / 110 VAC; 500 W / 220 VAC
- Detección e instalación
-
Diámetro de detección
8-12 m when ambient temperature is below 27 C
Rango de detección
Cobertura de techo de 360 grados
Motion detection speed
0.6-1.5 m/s
Altura de instalación
2.5-3.5 m
Temperatura de funcionamiento
-10 a +40 C
Humedad de funcionamiento
< 93% RH
Ceiling cutout
82-90 mm circular hole for spring clip mounting
Face diameter
106 mm
FAQ
Does the RZ038-5A need a neutral wire?
Yes. The AC wiring diagram requires White to Neutral, Red to Load, and Black to Live.
What loads can the 5A model control?
The manual lists 500 W / 110 VAC and 1100 W / 220 VAC for incandescent or halogen loads, and 250 W / 110 VAC and 500 W / 220 VAC for fluorescent, ballast, or LED loads.
Can the sensor keep lights off during bright daylight?
Yes. The Lux button can set Off, 15 Lux, 25 Lux, or 35 Lux, so the light sensor threshold can be matched to the room.
Where should this ceiling sensor be installed?
The manual recommends a 2.5-3.5 m installation height and advises avoiding heat sources, forced air, ventilation systems, ceiling fans, and hanging light fixtures near the sensor.
What happens after power is restored?
The sensor has a 1-minute warm-up period after power-up or power restoration. During that time it will not automatically control the load.
Should I choose the 5A or 10A RZ038 model?
Choose by verified load requirement. The 10A model has higher source-backed load ratings, while the 5A model is for lower-load AC lighting circuits.