Open Offices

Descubra o poder do controlo de iluminação automatizado na melhoria da eficiência e na redução do desperdício de energia. Saiba como otimizar o controlo de iluminação para eficiência e conforto no seu espaço de trabalho.

Revolutionize Your Open Office Lighting with Smart Occupancy Sensors

Open offices, characterized by their large areas and cubicle partitions, are a common sight in many modern workplaces. These spaces are typically bustling with activity, filled with employees working, collaborating, and moving around. The expansive area requires ample illumination, often provided by high-intensity light fixtures. These lights, left on throughout the workday, consume a substantial amount of energy. Moreover, even when the office is vacant, during off-hours or lunch breaks, the lights often remain on, leading to unnecessary energy consumption.

The high energy consumption of lighting in open offices is a concern for both environmental and economic reasons. With the increasing emphasis on energy efficiency and sustainability, businesses are seeking ways to reduce their energy footprint. Moreover, energy costs can account for a significant portion of a company’s operating expenses, making energy-saving measures a smart financial decision as well.

To address this, the integration of occupancy sensors in open offices presents a compelling solution. Occupancy sensors can automatically control lighting based on the presence of individuals in the space, significantly reducing unnecessary energy consumption. When the office is vacant, the sensors can automatically switch off or dim the lights, thereby conserving energy. With our sensors seamlessly integrated into your open office layout, you can transform your open office into an energy-efficient workspace that meets the stringent requirements of US Energy Codes.

Cumpra os Códigos de Energia

O International Energy Conservation Code (IECC) é um código modelo desenvolvido pelo International Code Council (ICC) para estabelecer requisitos mínimos de design e construção para a eficiência energética nos edifícios. O IECC é atualizado a cada três anos para incorporar as últimas práticas e tecnologias de conservação de energia.

IECC, Por Que Deve Preocupar-Se

O IECC é amplamente adotado por estados e municípios em todo os Estados Unidos. O IECC abrange vários aspetos do uso de energia, incluindo o envelope do edifício (paredes, tetos e janelas), sistemas de aquecimento e arrefecimento, e sistemas de iluminação.

O IECC exige controlos de iluminação específicos, como sensores de ocupação, para minimizar o desperdício de energia em espaços desocupados em várias áreas.

O padrão ANSI/ASHRAE/IES 90.1, Padrão de Energia para Locais e Edifícios Exceto Edifícios Resenciais de Baixa Elevação, é um padrão de energia amplamente reconhecido, publicado pela American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).

ASHRAE 90.1, Por Que Deve Preocupar-Se

O ASHRAE 90.1 é usado como referência para os códigos de energia de edifícios em todo os Estados Unidos e serve como caminho de conformidade dentro do IECC, que descreve os requisitos mínimos para o desempenho energético eficiente dos componentes de edifícios comerciais, incluindo envelopes de edifícios, sistemas HVAC, sistemas de aquecimento de água e sistemas de iluminação.

O padrão ASHRAE 90.1 especifica as densidades de potência de iluminação máximas permitidas e os requisitos mínimos de controlo de iluminação, incluindo o uso de sensores de ocupação em áreas específicas.

O Título 24, parte 6 do California Building Standards Code, oficialmente conhecido como Building Energy Efficiency Standards for Residential and Nonresidential Buildings, é administrado pela California Energy Commission e é atualizado periodicamente para refletir novas tecnologias e métodos de eficiência energética.

Título 24, Por Que Deve Preocupar-Se

O Título 24 é conhecido pelos seus requisitos rigorosos, frequentemente considerados mais rigorosos do que os encontrados em muitos outros códigos de energia em todo os Estados Unidos. O Título 24 exige padrões rigorosos de desempenho energético para todos os aspetos da construção de edifícios, o que inclui aquecimento, ventilação, ar condicionado (HVAC), aquecimento de água e iluminação.

O Título 24 exige a instalação de sensores de ocupação que ajustam a iluminação com base na ocupação do espaço em áreas específicas de edifícios comerciais para garantir que a energia não seja desperdiçada.

Adoção do Código de Energia por Estado

Expanda para ver a tabela detalhada ↓

EstadoCódigo Comercial AtualCategoria de Eficiência do Código Comercial
Alabama90.1-201390.1-2013
AlascaNenhum estadualSem código estadual
ArizonaGoverno local<90.1-2007
Arkansas2009 IECC e 90.1-200790.1-2007
Califórnia2022 Building Energy Efficiency Standards90.1-2019
ColoradoGoverno localSem código estadual
Connecticut2021 IECC e 90.1-201990.1-2019
Delaware2018 IECC e 90.1-201690.1-2013
Distrito de Columbia90.1-2013^90.1-2019
Flórida2021 IECC e 90.1-2019^90.1-2016
Geórgia2015 IECC e 90.1-2013^90.1-2013
HavaíGoverno local90.1-2013
Idaho2018 IECC e 90.1-201690.1-2013
Illinois2021 IECC e 90.1-201990.1-2019
Indiana90.1-200790.1-2007
IowaIECC 2012 e 90.1-201090.1-2007
KansasGoverno localSem código estadual
KentuckyIECC 2012 e 90.1-201090.1-2007
Louisiana2021 IECC e 90.1-2019^90.1-2016
MaineIECC 2015 e 90.1-201390.1-2013
Maryland2021 IECC e 90.1-2019^90.1-2019
MassachusettsIECC 2018 e 90.1-2016^90.1-2019
Michigan2015 IECC e 90.1-2013^90.1-2013
Minnesota90.1-2019^90.1-2019
MississippiNenhum estadualSem código estadual
MissouriGoverno localSem código estadual
Montana2021 IECC e 90.1-201990.1-2019
Nebraska2018 IECC e 90.1-201690.1-2013
Nevada2018 IECC e 90.1-201690.1-2013
New HampshireIECC 2018 e 90.1-2016^90.1-2013
New Jersey90.1-201990.1-2019
New Mexico2021 IECC e 90.1-2019^90.1-2019
New YorkIECC 2018 e 90.1-2016^90.1-2016
North Carolina2015 IECC e 90.1-2013^90.1-2010
North DakotaGoverno localSem código estadual
Ohio2021 IECC e 90.1-2019^90.1-2016
OklahomaIECC 2006 e 90.1-2004<90.1-2007
Oregon90.1-201990.1-2019
Pennsylvania2018 IECC e 90.1-201690.1-2013
Rhode IslandIECC 2018 e 90.1-2016^90.1-2013
South Carolina2009 IECC e 90.1-200790.1-2007
South DakotaGoverno localSem código estadual
TennesseeIECC 2021 e 90.1-201390.1-2007
TexasIECC 2015 e 90.1-201390.1-2013
Utah2021 IECC e 90.1-2019^90.1-2019
Vermont2021 IECC e 90.1-2019^90.1-2019
Virginia2021 IECC e 90.1-2019^90.1-2019
WashingtonCódigo de Energia do Estado de Washington 201890.1-2019
TennesseeIECC 2012 e 90.1-201090.1-2007
TexasIECC 2015 e 90.1-201390.1-2013
Utah2021 IECC e 90.1-2019^90.1-2019
VermontIECC 2018 e 90.1-2016^90.1-2019
Virginia2021 IECC e 90.1-2019^90.1-2019
WashingtonCódigo de Energia do Estado de Washington 201890.1-2019
West Virginia90.1-201390.1-2013
Wisconsin2015 IECC e 90.1-2013^90.1-2010
WyomingGoverno localSem código estadual
  • ^ Quando uma emenda com impacto na eficiência energética pode ser quantificada usando os Modelos de Edifícios Protótipo do DOE, ela foi incluída na análise.
  • Para estados que adotam tanto o IECC como o 90.1, o código IECC é geralmente analisado como o código estadual atual neste estudo, exceto para estados com extensas emendas ao IECC.

Soluções com Sensores

Descubra como a Rayzeek pode resolver os seus desafios de poupança de energia.

Ver Todas as Ofertas

Design Guide Key Concepts for Open Offices

Designing an energy-efficient lighting control solution for open offices involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.

In an open office setting, the primary areas to consider for sensor placement are the main walkways and areas with high foot traffic. These areas are crucial for sensor placement as they are the main areas of human traffic:

  • Cover Main Walkways: The main walkways in an open office are the areas with the highest foot traffic. Therefore, these should be the primary focus when placing sensors. Ceiling-mounted sensors are ideal for these areas as they provide a wide coverage area and are strategically placed to cover the entire length.
  • Overlap Coverage on Walkways: To avoid blind spots, ensure that the coverage patterns of the sensors overlap along the walkways. This ensures continuous detection as people move through the space, preventing any gaps in sensor coverage.
  • Use a Long Timeout: Given the size and activity level in open offices, use a longer timeout setting (15 or 20 minutes) on the sensors. This prevents the lights from turning off too soon when there’s no movement detected for a brief period.
  • Consider Wall-Mounted Sensors: If the cubicle walls are short, consider using wall-mounted sensors in addition to ceiling-mounted ones. These can provide additional coverage and ensure that all areas of the office are monitored.
  • Avoid Air Vents: Don’t place sensors near air vents. The vibration and airflow can reduce the effectiveness of the sensors. PIR sensors should not be within 4ft of an air vent, and ultrasonic sensors should not be within 6ft of an air vent.
  • Controlo Manual: Incorporate manual controls that are integrated with the occupancy sensors. This allows for manual override to turn ON/OFF all lighting when necessary.

Interruptores de Sensor de Parede

Interruptores de Sensor de Movimento RZ020/021

  • Opções de fiação de 2 fios, 3 fios, 4 fios
  • Ocupação, Vacância, Ligar/Desligar Manual
  • Controlo de tempo de atraso e luz ambiente ajustáveis

Sensores de Parede Sem Fios Multi-localização

Kits RZ020A/021A + RZ022W

  • Interruptor de sensor de ocupação com fiação RZ021A/022A
  • Interruptor acompanhante sem fios (RZ022W) para controlo multi-localização

Sensores de Ocupação no Teto

RZ036

  • Sensores de ocupação com fiação
  • Ligar automaticamente, desligar automaticamente
  • Disponível para tensão de linha e baixa tensão

Características principais incluídas:

  • Controlo manual integrado para ligar/desligar toda a iluminação
  • Sensores de vacância (Apenas Manual ON): As luzes devem ser ligadas apenas manualmente
  • Tempo de atraso ajustável, a iluminação desliga-se automaticamente completamente após 15 minutos
  • Adicional: kits sem fios multi-localização para expandir o alcance de controlo sem refazer a fiação
  • Adicional: múltiplas opções de fiação disponíveis tanto para novas construções como para projetos de retrofit.

Cumprimento das Disposições Obrigatórias

IECC – 2011

C405.2.1 Controlos de sensor de ocupante

Devem ser instalados controlos de sensor de ocupante para controlar as luzes no espaço.

For open offices < 300 sq. ft:

C405.2.1.1 Funções de controlo do sensor de ocupante

  • Ligação manual ou parcial a uma potência não superior a 50%.
  • Desligamento completo dentro de 20 minutos após todos os ocupantes terem saído do espaço
  • Um controlo manual para desligar as luzes.

For open offices > 300 sq. ft:

  • The general lighting shall be controlled separately in control zones with floor areas not greater than 600 sq. ft within the open plan office space.
  • In each control zone, the general lighting shall be permitted to automatically turn on within the control zone. In other unoccupied zones, the general lighting shall be permitted to turn on to < 20% full power(or unaffected).
  • Automatically turn off general lighting in all control zones within 20 minutes after all occupants have left the space.
  • In each control zone, the general lighting shall turn off or uniformly reduce lighting power to an unoccupied setpoint of < 20% full power within 20 minutes after all occupants have left.

ASHRAE 90.1 – 2022

For open offices in any sizes:

9.4.1.1 a Controlo local

Deve haver um ou mais dispositivos de controlo manual de iluminação que proporcionem controlo LIGAR e DESLIGAR
de toda a iluminação no espaço.

9.4.1.1 b Restrito a ligação manual

Nenhuma iluminação deve ser ligada automaticamente

9.4.1.1 c Restricted to partial automatic ON

No more than 50% of the lighting power for the general lighting shall be allowed to be automatically turned on

** NOTE: At least one 9.4.1.1 b or 9.4.1.1 c shall be implemented.

9.4.1.1 H Controlo de desligamento completo automático

Toda a iluminação no espaço deve ser desligada automaticamente dentro de 20 minutos de todos os ocupantes terem saído do espaço

Additionally, for open offices > 300 sq. ft:

9.4.1.1 g Automatic reduction control

The general lighting power in the space shall be automatically reduced by at least 50% within 15 minutes of all occupants leaving the space.

Title 24 – 2022

For open offices in any sizes:

130.1 (a) Controlos manuais de área.

Cada área delimitada por divisórias que atinjam o teto deve dispor de controlos de iluminação que permitam ligar e desligar manualmente a iluminação nessa área.

130.1 (c) Controlos de desligamento.

Additionally, for open offices <250 sq. ft:

130.1 (c) 5. Occupant sensing controls are required for specified offices.

A iluminação deve ser controlada com controlos de sensores de ocupação para desligar automaticamente toda a iluminação em 20 minutos ou menos após a zona de controlo estar desocupada, e devem funcionar como:

  • A. Controlos de sensores de ocupação (se 130.1(b) não exigir controlos de iluminação multinível); ou
  • B. Controlos de sensores de ocupação parcial-ON, ou
  • C. Controlos de sensores de vaga, onde toda a iluminação responde apenas a uma entrada manual ON

Additionally, for open offices > 250 sq. ft:

130.1 (c) 6. Full or partial-OFF occupant sensing controls are required for offices greater than 250 square feet.

In office spaces greater than 250 square feet, general lighting shall be controlled with occupant sensing controls that meet all of the following:

  • Lighting shall be controlled separately in control zones not greater than 600 square feet. For luminaires with an embedded occupant sensor that are capable of reducing power independently from other luminaires, each luminaire can be considered its own control zone
  • The occupant sensing controls shall uniformly reduce lighting power in the control zone by at least 80% full power(or off) in 20 minutes or less after the control zone is unoccupied.
  • The occupant sensing controls shall automatically turn off lighting in ALL control zones in 20 minutes or less after the entire office space is unoccupied
  • When occupancy is detected:
    • in each control zone, lighting shall be allowed to automatically turn on to any level up to full power.
    • in other control zones that are unoccupied, lighting shall operate at no more than 20% full power.

Ouça-nos.

Deixe a Rayzeek ajudar a projetar e fornecer uma solução de iluminação personalizada para economia de energia para si.

    Portuguese (Portugal)