Lobby
Descubra o potencial de poupança de energia do seu lobby. Saiba como cumprir os códigos de energia e reduzir o desperdício de energia com as nossas soluções personalizadas.

Transform Your Lobby into an Energy-Efficient Space
The lobby is often the first point of contact for visitors and employees in a commercial building. It’s a space that needs to be well-lit and welcoming at all times. It’s a bustling area, filled with people coming and going at all hours. The lighting in these areas is typically high-intensity and left on for extended periods, leading to significant energy consumption.
Traditional lighting systems in lobbies are often manually controlled, resulting in lights being left on unnecessarily when the space is unoccupied, leading to high energy waste. Moreover, the diverse activities and varying occupancy levels in lobbies make it challenging to manage lighting efficiently. This not only increases operational costs but also contributes to a larger carbon footprint.
To address these issues, occupancy sensors offer an effective solution. These devices can automatically turn off or dim the lights when the lobby is vacant, significantly reducing energy consumption. Rayzeek’s range of occupancy sensors, including wall and ceiling-mounted options, provide a tailored solution for lobbies, ensuring efficient lighting control without compromising on comfort or safety.
Cumpra os Códigos de Energia

O International Energy Conservation Code (IECC) é um código modelo desenvolvido pelo International Code Council (ICC) para estabelecer requisitos mínimos de design e construção para a eficiência energética nos edifícios. O IECC é atualizado a cada três anos para incorporar as últimas práticas e tecnologias de conservação de energia.
IECC, Por Que Deve Preocupar-Se
O IECC é amplamente adotado por estados e municípios em todo os Estados Unidos. O IECC abrange vários aspetos do uso de energia, incluindo o envelope do edifício (paredes, tetos e janelas), sistemas de aquecimento e arrefecimento, e sistemas de iluminação.
O IECC exige controlos de iluminação específicos, como sensores de ocupação, para minimizar o desperdício de energia em espaços desocupados em várias áreas.

O padrão ANSI/ASHRAE/IES 90.1, Padrão de Energia para Locais e Edifícios Exceto Edifícios Resenciais de Baixa Elevação, é um padrão de energia amplamente reconhecido, publicado pela American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).
ASHRAE 90.1, Por Que Deve Preocupar-Se
O ASHRAE 90.1 é usado como referência para os códigos de energia de edifícios em todo os Estados Unidos e serve como caminho de conformidade dentro do IECC, que descreve os requisitos mínimos para o desempenho energético eficiente dos componentes de edifícios comerciais, incluindo envelopes de edifícios, sistemas HVAC, sistemas de aquecimento de água e sistemas de iluminação.
O padrão ASHRAE 90.1 especifica as densidades de potência de iluminação máximas permitidas e os requisitos mínimos de controlo de iluminação, incluindo o uso de sensores de ocupação em áreas específicas.

O Título 24, parte 6 do California Building Standards Code, oficialmente conhecido como Building Energy Efficiency Standards for Residential and Nonresidential Buildings, é administrado pela California Energy Commission e é atualizado periodicamente para refletir novas tecnologias e métodos de eficiência energética.
Título 24, Por Que Deve Preocupar-Se
O Título 24 é conhecido pelos seus requisitos rigorosos, frequentemente considerados mais rigorosos do que os encontrados em muitos outros códigos de energia em todo os Estados Unidos. O Título 24 exige padrões rigorosos de desempenho energético para todos os aspetos da construção de edifícios, o que inclui aquecimento, ventilação, ar condicionado (HVAC), aquecimento de água e iluminação.
O Título 24 exige a instalação de sensores de ocupação que ajustam a iluminação com base na ocupação do espaço em áreas específicas de edifícios comerciais para garantir que a energia não seja desperdiçada.
Adoção do Código de Energia por Estado

Expanda para ver a tabela detalhada ↓
| Estado | Código Comercial Atual | Categoria de Eficiência do Código Comercial |
|---|---|---|
| Alabama | 90.1-2013 | 90.1-2013 |
| Alasca | Nenhum estadual | Sem código estadual |
| Arizona | Governo local | <90.1-2007 |
| Arkansas | 2009 IECC e 90.1-2007 | 90.1-2007 |
| Califórnia | 2022 Building Energy Efficiency Standards | 90.1-2019 |
| Colorado | Governo local | Sem código estadual |
| Connecticut | 2021 IECC e 90.1-2019 | 90.1-2019 |
| Delaware | 2018 IECC e 90.1-2016 | 90.1-2013 |
| Distrito de Columbia | 90.1-2013^ | 90.1-2019 |
| Flórida | 2021 IECC e 90.1-2019^ | 90.1-2016 |
| Geórgia | 2015 IECC e 90.1-2013^ | 90.1-2013 |
| Havaí | Governo local | 90.1-2013 |
| Idaho | 2018 IECC e 90.1-2016 | 90.1-2013 |
| Illinois | 2021 IECC e 90.1-2019 | 90.1-2019 |
| Indiana | 90.1-2007 | 90.1-2007 |
| Iowa | IECC 2012 e 90.1-2010 | 90.1-2007 |
| Kansas | Governo local | Sem código estadual |
| Kentucky | IECC 2012 e 90.1-2010 | 90.1-2007 |
| Louisiana | 2021 IECC e 90.1-2019^ | 90.1-2016 |
| Maine | IECC 2015 e 90.1-2013 | 90.1-2013 |
| Maryland | 2021 IECC e 90.1-2019^ | 90.1-2019 |
| Massachusetts | IECC 2018 e 90.1-2016^ | 90.1-2019 |
| Michigan | 2015 IECC e 90.1-2013^ | 90.1-2013 |
| Minnesota | 90.1-2019^ | 90.1-2019 |
| Mississippi | Nenhum estadual | Sem código estadual |
| Missouri | Governo local | Sem código estadual |
| Montana | 2021 IECC e 90.1-2019 | 90.1-2019 |
| Nebraska | 2018 IECC e 90.1-2016 | 90.1-2013 |
| Nevada | 2018 IECC e 90.1-2016 | 90.1-2013 |
| New Hampshire | IECC 2018 e 90.1-2016^ | 90.1-2013 |
| New Jersey | 90.1-2019 | 90.1-2019 |
| New Mexico | 2021 IECC e 90.1-2019^ | 90.1-2019 |
| New York | IECC 2018 e 90.1-2016^ | 90.1-2016 |
| North Carolina | 2015 IECC e 90.1-2013^ | 90.1-2010 |
| North Dakota | Governo local | Sem código estadual |
| Ohio | 2021 IECC e 90.1-2019^ | 90.1-2016 |
| Oklahoma | IECC 2006 e 90.1-2004 | <90.1-2007 |
| Oregon | 90.1-2019 | 90.1-2019 |
| Pennsylvania | 2018 IECC e 90.1-2016 | 90.1-2013 |
| Rhode Island | IECC 2018 e 90.1-2016^ | 90.1-2013 |
| South Carolina | 2009 IECC e 90.1-2007 | 90.1-2007 |
| South Dakota | Governo local | Sem código estadual |
| Tennessee | IECC 2021 e 90.1-2013 | 90.1-2007 |
| Texas | IECC 2015 e 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC e 90.1-2019^ | 90.1-2019 |
| Vermont | 2021 IECC e 90.1-2019^ | 90.1-2019 |
| Virginia | 2021 IECC e 90.1-2019^ | 90.1-2019 |
| Washington | Código de Energia do Estado de Washington 2018 | 90.1-2019 |
| Tennessee | IECC 2012 e 90.1-2010 | 90.1-2007 |
| Texas | IECC 2015 e 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC e 90.1-2019^ | 90.1-2019 |
| Vermont | IECC 2018 e 90.1-2016^ | 90.1-2019 |
| Virginia | 2021 IECC e 90.1-2019^ | 90.1-2019 |
| Washington | Código de Energia do Estado de Washington 2018 | 90.1-2019 |
| West Virginia | 90.1-2013 | 90.1-2013 |
| Wisconsin | 2015 IECC e 90.1-2013^ | 90.1-2010 |
| Wyoming | Governo local | Sem código estadual |
- ^ Quando uma emenda com impacto na eficiência energética pode ser quantificada usando os Modelos de Edifícios Protótipo do DOE, ela foi incluída na análise.
- Para estados que adotam tanto o IECC como o 90.1, o código IECC é geralmente analisado como o código estadual atual neste estudo, exceto para estados com extensas emendas ao IECC.
Design Guide Key Concepts for Lobby
Designing an energy-efficient lighting control solution for lobby involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.

In a lobby, the primary areas that need to be covered by occupancy sensors are the entrance, the reception desk, and any seating or waiting areas. Here’s a possible design guide for a lobby:
- Área de Entrada: Install a ceiling occupancy sensor near the entrance. This sensor will detect the movement of people entering or exiting the lobby, ensuring the lights are activated when needed. Our ceiling sensors offer Auto ON and Full OFF functionality, providing automatic control of lighting based on occupancy.
- Main Lobby Area: For larger lobbies, additional ceiling sensors may be required to cover the entire space. These sensors should be strategically placed to cover high-traffic areas, such as near the reception desk or waiting areas. The overlapping coverage of multiple sensors ensures there are no blind spots.
- Reception Desk: Place a wall-mounted sensor near the reception desk. This sensor will detect the presence of the receptionist and any visitors at the desk, keeping the lights on in this area during occupied periods.
- Seating/Waiting Areas: Install additional ceiling-mounted sensors in any seating or waiting areas. These sensors will detect when these areas are occupied and adjust the lighting accordingly.
- Controlo Manual: Install a manual control near the entrance or reception desk. This allows for manual override of the lighting system when necessary.
- Corridors Leading to Other Areas: Corridors leading to elevators, staircases, or other parts of the building should have their own wall or ceiling-mounted sensors. This ensures that lights in these areas are only activated when someone is passing through.
Produtos e Soluções em Destaque
Características principais incluídas:
- Controlo manual integrado para ligar/desligar toda a iluminação
- Sensores de vacância (Apenas Manual ON): As luzes devem ser ligadas apenas manualmente
- Tempo de atraso ajustável, a iluminação desliga-se automaticamente completamente após 15 minutos
- Adicional: kits sem fios multi-localização para expandir o alcance de controlo sem refazer a fiação
- Adicional: múltiplas opções de fiação disponíveis tanto para novas construções como para projetos de retrofit.

Cumprimento das Disposições Obrigatórias
IECC – 2011
C405.2.1 Controlos de sensor de ocupante
Devem ser instalados controlos de sensor de ocupante para controlar as luzes no espaço.
C405.2.1.1 Funções de controlo do sensor de ocupante
- Ligação manual ou parcial a uma potência não superior a 50%.
- Desligamento completo dentro de 20 minutos após todos os ocupantes terem saído do espaço
- Um controlo manual para desligar as luzes.
Full automatic-on controls with no manual control are permitted in lobbies where manual operation would endanger occupant safety or security.
ASHRAE 90.1 – 2022
9.4.1.1 a Controlo local
Deve haver um ou mais dispositivos de controlo manual de iluminação que proporcionem controlo LIGAR e DESLIGAR
de toda a iluminação no espaço.
9.4.1.1 g Automatic reduction control
The general lighting power in the space shall be automatically reduced by at least 50% within 15 minutes of all occupants leaving the space.
** NOTE: 9.4.1.1 g is required in all other lobbies except (Elevator, Hotel, Motion picture theater, Performing arts theater)
9.4.1.1 h Automatic full OFF control
All lighting in the space shall be automatically shut off within 15 minutes of all occupants leaving the space.
9.4.1.1 i Scheduled shutoff
All lighting in the space shall be automatically shut off during periods when the space is scheduled to be unoccupied.
** NOTE: At least one 9.4.1.1 h or 9.4.1.1 i shall be implemented.
Title 24 – 2022
130.1 (a) Controlos manuais de área.
Cada área delimitada por divisórias que atinjam o teto deve dispor de controlos de iluminação que permitam ligar e desligar manualmente a iluminação nessa área.
130.1 (c) Controlos de desligamento.
A iluminação deve ser controlada com controlos de sensores de ocupação para desligar automaticamente toda a iluminação em 20 minutos ou menos após a zona de controlo estar desocupada, e devem funcionar como:
- A. Controlos de sensores de ocupação (se 130.1(b) não exigir controlos de iluminação multinível); ou
- B. Controlos de sensores de ocupação parcial-ON, ou
- C. Controlos de sensores de vaga, onde toda a iluminação responde apenas a uma entrada manual ON