Sufitowy czujnik ruchu i obecności o napięciu sieciowym (RZ037-5A)

RZ037-5A

$15.00

RZ037-5A is a line voltage passive infrared (PIR) ceiling-mount occupancy sensor for automatic lighting and fan control in residential and commercial spaces.

The RZ037-5A connects directly to line voltage and mounts to the ceiling (neutral required). It offers 360° coverage with an 8–12 m detection diameter, push-button setup for time delay, Lux, and sensitivity, and a 1-minute warm-up on power-up for stable operation.

Main Features:

  • Auto-ON/Auto-OFF occupancy mode (Lux override available)
  • 360-degree coverage; 8–12 m detection diameter
  • 100V ~ 265V AC line voltage, 5A rating
  • Push-button adjustment: time delay, Lux, sensitivity
  • Neutral wire required; 3-wire (L, N, Load) wiring
Dowiedz się więcej

Główne cechy produktu

  • Line voltage 100–265V AC, 5A rating (neutral required)
  • 360° ceiling-mount PIR with 8–12 m detection diameter
  • Push-button setup: Time, Lux, Sensitivity

Szybka dostawa: 99% w magazynie

Pełna linia produktów aktywowanych ruchem

Wyślij zapytanie dla hurtowych zamówień ODM/OEM

Sufitowy czujnik obecności

The RZ037-5A is a ceiling-mounted 360-degree PIR motion sensor switch designed for reliable lighting control. Using advanced passive infrared (PIR) and microcontroller technology, it delivers stable performance and accurate detection while helping achieve significant energy savings.

The 5A rating is suitable for common residential and light commercial loads such as lighting circuits and exhaust fans.

Łatwa regulacja

Settings are adjusted with push buttons under the top cover—no tools required. Configure:

  • Opóźnienie czasowe: od 15 s do 30 min
  • Poziom czujnika światła: WYŁ., 15, 25 (domyślnie), 35 luksów
  • Czułość: Wysoka lub Niska

Note: After first power-up or power restoration, the sensor has a 1-minute warm-up period during which it will not control the load.

Funkcje, zalety, specyfikacja

The RZ037 ceiling occupancy sensor is a versatile ceiling-mount motion sensor for residential and commercial applications. It provides 360-degree coverage with adjustable time delay, sensitivity, and ambient light threshold for dependable, energy-saving control.

Funkcje i zalety

  • Advanced PIR with microcontroller for stable, accurate detection
  • Regulowane opóźnienie czasowe, poziom natężenia światła (Lux) i czułość
  • Sufitowe pole widzenia 360° o średnicy detekcji 8–12 m
  • Wymagany przewód neutralny
  • Szeroki zakres napięcia wejściowego 100–265 VAC
Cechy

Tryb czujnika

Tryb obecności; tryb obecności bez czujnika światła (Lux WYŁ.)

Opóźnienie czasowe

15 s, 30 s, 1 min (domyślnie), 3 min, 5 min, 10 min, 30 min

Czujnik światła

Wył., 15 Lux, 25 Lux (domyślnie), 35 Lux

Czułość czujnika

Low Sensitivity, High Sensitivity

Power-Up

1-minute warm-up (no load control during warm-up)

Working Conditions

Źródło zasilania

100 VAC ~ 265 VAC

Częstotliwość zasilania

50 / 60 Hz

Installation Height

2.5 m ~ 3.5 m

Wilgotność robocza

< 93% RH

Temperatura pracy

-10 ~ +40℃

Detection Capability

Detection Diameter

8 m ~ 12 m (<27℃)

Zasięg detekcji

360°

Detection Speed

0.6 ~ 1.5 m/s

Load Compatibility (RZ037-5A)

Fluorescent / Ballast / LED

250 W / 110 VAC; 500 W / 220 VAC

Incandescent / Halogen

500 W / 110 VAC; 1100 W / 220 VAC

Versatile Applications

The RZ037 is the ideal ceiling-mounted occupancy sensor solution for 100V ~265V home applications and commercial projects. Perfect for frequently visited spaces, such as public bathrooms, hallways, garages, open offices, breakrooms, stairwells, or corridors.

Bathroom

Occupancy sensor with light sensor enabled is the ideal mode for bathroom usage, especially when you need to use it at night. Manual ON mode can be suitable for long showers.

Garage

Walk in and out of your home garage without the need to reach the light switch with an occupancy sensor switch. Enable daylight sensing to save more energy in the daytime.

Laundry Room

Enjoy the automatic lighting turned on and off for you when arm-full with piles of laundry to wash or clean clothes to take away.

Kuchnia

Place an occupancy sensor switch at the entrance and enjoy the automatic lighting while you’re busy cooking and preparing food for your family.

Hallway

Occupancy/vacancy sensor switches can reduce the hours of lighting used by approximately 53% on dark hallways in your basement.

Breakroom

Occupancy sensors can reduce energy waste by 39% and increase energy-saving up to 17% with a 20-minute time delay for breakrooms.

Gabinet prywatny

Rayzeek motion sensor switches provide max flexibility for office use cases. Occurpnay, vacancy or manual mode, your office, your call.

Sala konferencyjna

Vacancy switch with manual override feature is perfect for conference rooms where it’s not frequently used and requires manual turn on and off for presentations.

Filmy

RZ037 User Guide

Fire Resistance Testing – RZ036

Load Testing

Zasoby

rz021 occupancy vacanccy sensor switch residential appliction

Rozszerz swój system czujników ruchu

Zobacz wszystkie nasze energooszczędne czujniki ruchu

Opinie

Na razie nie ma opinii o produkcie.

Napisz pierwszą opinię o „Ceiling Mount Line Voltage Occupancy Motion Sensor (RZ037-5A)”

Może spodoba się również…