Classrooms

Discover the energy-saving potential of classrooms with Rayzeek’s occupancy sensor design guide. Learn how to meet energy code requirements while creating a more efficient learning environment.

Transforming Classrooms into Energy-Efficient Learning Spaces

Classrooms are dynamic spaces that serve as the foundation for learning and development. They are often filled with a variety of lighting fixtures, from overhead lights to task lighting, all of which contribute to a significant amount of energy consumption. The lighting in these spaces is typically left on for extended periods, even when the room is unoccupied, leading to unnecessary energy waste.

In a typical classroom, the lighting needs can vary greatly depending on the time of day, the activities taking place, and the number of occupants. This variability makes it challenging to manage lighting effectively and efficiently. As a result, there is a pressing need for solutions that can automatically control lighting based on occupancy, thereby reducing unnecessary energy consumption.

The need for energy conservation in classrooms is clear, and one of the most effective solutions is the use of occupancy sensors. These devices can automatically turn off lights when a room is vacant, significantly reducing energy consumption. With Rayzeek’s range of occupancy sensors, classrooms can become more energy-efficient, meeting the requirements of energy codes while also reducing operational costs.

에너지 코드 준수하기

국제 에너지 보존 코드(IECC)는 국제 코드 위원회(ICC)에서 개발한 모델 코드로, 건물의 에너지 효율을 위한 최소 설계 및 시공 요구 사항을 설정합니다. IECC는 최신 에너지 보존 관행과 기술을 통합하기 위해 3년마다 업데이트됩니다.

IECC, 왜 중요한지

IECC는 미국 전역의 주 및 지방 자치단체에서 광범위하게 채택되고 있습니다. IECC는 건물 외피(벽, 지붕, 창문), 난방 및 냉방 시스템, 조명 시스템을 포함한 에너지 사용의 다양한 측면을 다룹니다.

IECC는 다양한 구역의 미사용 공간에서 에너지 낭비를 최소화하기 위해 재실 센서와 같은 특정 조명 제어를 의무화합니다.

ANSI/ASHRAE/IES 표준 90.1, 저층 주거 건물 외의 현장 및 건물 에너지 표준은 미국 냉난방 공학회(ASHRAE)에서 발표한 널리 인정받는 에너지 표준입니다.

ASHRAE 90.1, 왜 중요한지

ASHRAE 90.1은 미국 전역의 건물 에너지 코드의 기준으로 사용되며, IECC 내에서 건물 외피, HVAC 시스템, 급탕 시스템 및 조명 시스템을 포함한 상업용 건물 구성 요소의 에너지 효율 성능에 대한 최소 요구 사항을 설명하는 규정 준수 경로 역할을 합니다.

ASHRAE 90.1 표준은 특정 구역에서의 재실 센서 사용을 포함하여, 최대 허용 조명 밀도 및 최소 조명 제어 요구 사항을 명시합니다.

캘리포니아 건물 기준 코드의 제목 24, 6부는 공식적으로 주거 및 비주거 건물의 건물 에너지 효율 기준으로 알려져 있으며, 캘리포니아 에너지 위원회가 관리하고 새로운 에너지 효율 기술과 방법을 반영하기 위해 정기적으로 업데이트됩니다.

Title 24, 왜 중요한지

Title 24는 엄격한 요구 사항으로 유명하며, 미국 전역의 다른 많은 에너지 코드보다 더 엄격한 것으로 간주됩니다. Title 24는 난방, 환기, 공조(HVAC), 급탕 및 조명을 포함한 건물 시공의 모든 측면에 대한 엄격한 에너지 성능 기준을 의무화합니다.

Title 24는 상업용 건물의 특정 구역에서 에너지가 낭비되지 않도록 방의 사용 여부에 따라 조명을 조정하는 재실 센서를 설치하도록 요구합니다.

주별 에너지 코드 채택 현황

상세 표를 보려면 펼치기 ↓

현재 상업용 코드상업용 코드 효율 등급
앨라배마90.1-201390.1-2013
알래스카주 전체 없음주 전체 코드 없음
애리조나지자체 자치<90.1-2007
아칸소2009 IECC 및 90.1-200790.1-2007
캘리포니아2022 건물 에너지 효율 기준90.1-2019
콜로라도지자체 자치주 전체 코드 없음
코네티컷2021 IECC 및 90.1-201990.1-2019
델라웨어2018 IECC 및 90.1-201690.1-2013
컬럼비아 특별구90.1-2013^90.1-2019
플로리다2021 IECC 및 90.1-2019^90.1-2016
조지아2015 IECC 및 90.1-2013^90.1-2013
하와이지자체 자치90.1-2013
아이다호2018 IECC 및 90.1-201690.1-2013
일리노이2021 IECC 및 90.1-201990.1-2019
인디애나90.1-200790.1-2007
아이오와2012 IECC 및 90.1-201090.1-2007
캔자스지자체 자치주 전체 코드 없음
켄터키2012 IECC 및 90.1-201090.1-2007
루이지애나2021 IECC 및 90.1-2019^90.1-2016
메인2015 IECC 및 90.1-201390.1-2013
메릴랜드2021 IECC 및 90.1-2019^90.1-2019
매사추세츠2018 IECC 및 90.1-2016^90.1-2019
미시간2015 IECC 및 90.1-2013^90.1-2013
미네소타90.1-2019^90.1-2019
미시시피주 전체 없음주 전체 코드 없음
미주리지자체 자치주 전체 코드 없음
몬태나2021 IECC 및 90.1-201990.1-2019
네브래스카2018 IECC 및 90.1-201690.1-2013
네바다2018 IECC 및 90.1-201690.1-2013
뉴햄프셔2018 IECC 및 90.1-2016^90.1-2013
뉴저지90.1-201990.1-2019
뉴멕시코2021 IECC 및 90.1-2019^90.1-2019
뉴욕2018 IECC 및 90.1-2016^90.1-2016
노스캐롤라이나2015 IECC 및 90.1-2013^90.1-2010
노스다코타지자체 자치주 전체 코드 없음
오하이오2021 IECC 및 90.1-2019^90.1-2016
오클라호마2006 IECC 및 90.1-2004<90.1-2007
오레곤90.1-201990.1-2019
펜실베이니아2018 IECC 및 90.1-201690.1-2013
로드아일랜드2018 IECC 및 90.1-2016^90.1-2013
사우스캐롤라이나2009 IECC 및 90.1-200790.1-2007
사우스다코타지자체 자치주 전체 코드 없음
테네시2018 IECC 및 90.1-201390.1-2007
텍사스2015 IECC 및 90.1-201390.1-2013
유타2021 IECC 및 90.1-2019^90.1-2019
버몬트2021 IECC 및 90.1-2019^90.1-2019
버지니아2021 IECC 및 90.1-2019^90.1-2019
워싱턴2018 워싱턴 주 에너지 코드90.1-2019
테네시2012 IECC 및 90.1-201090.1-2007
텍사스2015 IECC 및 90.1-201390.1-2013
유타2021 IECC 및 90.1-2019^90.1-2019
버몬트2018 IECC 및 90.1-2016^90.1-2019
버지니아2021 IECC 및 90.1-2019^90.1-2019
워싱턴2018 워싱턴 주 에너지 코드90.1-2019
웨스트 버지니아90.1-201390.1-2013
위스콘신2015 IECC 및 90.1-2013^90.1-2010
와이오밍지자체 자치주 전체 코드 없음
  • ^ 에너지 효율에 영향을 미치는 개정안이 DOE 프로토타입 빌딩 모델을 사용하여 정량화될 수 있을 경우, 해당 내용이 분석에 포함되었습니다.
  • IECC와 90.1를 동시에 채택한 주의 경우, IECC에 대한 광범위한 개정이 없는 한, 본 연구에서는 IECC 코드를 일반적으로 주의 현재 코드로 분석합니다.

센서 솔루션

Rayzeek이 에너지 절감 과제를 어떻게 해결할 수 있는지 알아보세요.

전체 제품 보기

Design Guide Key Concepts for Classrooms

Designing an energy-efficient lighting control solution for classrooms involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.

Designing an energy-efficient classroom with occupancy sensors involves careful planning and strategic placement of sensors:

  • Wall Occupancy/Vacancy Sensors: Install these sensors near the main entrance of the classroom. These sensors can detect when someone enters or leaves the room, and can automatically turn the lights on or off accordingly. They can also be manually controlled to turn all lights on or off.
  • 천장 재실 센서: These sensors should be installed in the center of the classroom, ensuring they have a clear view of the entire room to cover key areas such as the teacher’s desk, student desks, and any separate learning areas. They can detect any movement in the room, including minor movements such as students writing at their desks. When no movement is detected for a set period, the lights will automatically turn off.
  • Additional Sensors for Specific Areas: If the classroom has specific areas such as a reading corner or a lab area, additional sensors may be needed. These sensors can control the lighting in these specific areas based on occupancy, ensuring that lights are not left on unnecessarily.
  • 센서 설치 위치 고려사항: Avoid placing sensors near air vents or other sources of movement that could trigger the sensor falsely. Also, ensure the sensors’ view is not obstructed by tall furniture or fixtures.
  • Consideration of Natural Light: If the classroom has windows, the sensors should be programmed to consider the natural light coming into the room. This can help to further reduce energy consumption by utilizing natural light whenever possible.
  • Integration with Manual Control: All occupancy/vacancy sensors should be integrated with manual controls. This allows teachers to manually turn off the lights during activities like video presentations, even if the room is occupied.

벽면 센서 스위치

RZ020/021 모션 센서 스위치

  • 2와이어, 3와이어, 4와이어 배선 옵션
  • 인체 감지, 공실 감지, 수동 켜기/끄기
  • 조정 가능한 시간 지연 및 주변광 제어

다중 위치 무선 벽면 센서

RZ020A/021A + RZ022W 키트

  • 유선 RZ021A/022A 인체 감지 센서 스위치
  • 무선 동반 스위치 (RZ022W) – 다중 위치 제어용

천장 재실 센서

RZ036

  • 유선 재실 센서
  • 자동 ON, 자동 OFF
  • 라인 전압 및 저전압 사용 가능

핵심 기능 포함:

  • 모든 조명에 대한 통합 수동 ON/OFF 제어
  • 공실 센서 (수동 ON 전용): 조명은 수동으로만 켜야 합니다
  • 조절 가능한 시간 지연, 15분 후 조명이 자동으로 완전히 꺼집니다
  • 추가 사항: 재배선 없이 제어 범위를 확장할 수 있는 다중 위치 무선 키트
  • 추가 사항: 신축 및 리etrofit 프로젝트 모두에 사용할 수 있는 다양한 배선 옵션.

의무 조항 충족

IECC – 2011

C405.2.1 재실 센서 제어

해당 공간의 조명을 제어하기 위해 재실 센서를 설치해야 합니다.

C405.2.1.1 재실 센서 제어 기능

  • 수동으로 켜거나 50% 전력 이하로 부분적으로 켜기.
  • 모든 점유자가 공간을 떠난 후 20분 이내에 완전히 꺼짐
  • 조명을 끄기 위한 수동 제어.

ASHRAE 90.1 – 2022

9.4.1.1 a 로컬 제어

공간 내 모든 조명의 켜기/끄기 제어를 제공하는 하나 이상의 수동 조명 제어 장치가 있어야 합니다.
공간 내 모든 조명에 대해.

9.4.1.1 b 수동 켜기에 제한

어떤 조명도 자동으로 켜져서는 안 됩니다.

9.4.1.1 c Restricted to partial automatic ON

No more than 50% of the lighting power for the general lighting shall be allowed to be automatically turned on

** NOTE: At least one 9.4.1.1 b or 9.4.1.1 c shall be implemented.

For classrooms except shop classrooms (all other classrooms/lecture halls/training rooms):

9.4.1.1 h Automatic full OFF control

공간 내 모든 점유자가 공간을 떠난 후 20분 이내에 모든 조명이 자동으로 꺼져야 합니다.

Title 24 – 2022

130.1 (a) 수동 구역 제어.

천장 높이의 칸막이로 둘러싸인 각 구역은 해당 구역의 조명을 수동으로 켜고 끌 수 있는 조명 제어 장치를 제공해야 합니다.

130.1 (c) 전원 차단 제어.

조명은 제어 구역이 비워진 후 20분 이내에 모든 조명을 자동으로 차단하는 점유 감지 제어로 제어해야 하며, 다음 기능을 수행해야 합니다.

  • A. 점유 감지 제어 (130.1(b)에 의해 다단계 조명 제어가 요구되지 않는 경우); 또는
  • B. 부분 켜기 점유 감지 제어, 또는
  • C. 공실 감지 제어, 모든 조명이 수동 켜기 신호에만 응답하는 경우

여러분의 의견을 들려주세요.

Rayzeek가 여러분을 위해 맞춤형 절약형 조명 솔루션을 설계하고 제공할 수 있도록 도와드리겠습니다.