storage rooms

Discover the energy-saving potential of storage rooms with Rayzeek’s occupancy sensor design guide.

Maximize Energy Efficiency in Storage Rooms with Occupancy Sensors

Storage rooms, often overlooked, are integral parts of commercial buildings. These spaces are typically filled with shelves, boxes, and various items, and are used for storing supplies, equipment, or archived documents. Lighting in these areas is crucial for visibility and safety, but it can also be a significant source of energy waste. Traditional lighting systems in storage rooms are often left on unnecessarily, leading to high energy consumption and costs.

Moreover, storage rooms are usually equipped with fluorescent or LED lights, which, while energy-efficient, can still consume a considerable amount of power when left on for extended periods. The sporadic and unpredictable nature of storage room usage further exacerbates this issue, as lights are often left on even when the room is unoccupied, leading to unnecessary energy waste.

This energy wastage can be mitigated by using occupancy sensors. These devices automatically control lighting based on the presence or absence of people, ensuring lights are only on when needed. By installing occupancy sensors in storage rooms, businesses can significantly reduce their energy consumption, lower their utility bills, and contribute to a more sustainable environment.

Overhold energikoderne

Den internationale energisparekodeks (IECC) er en modelkodeks udviklet af International Code Council (ICC) for at fastsætte minimumskrav til design og konstruktion for energieffektivitet i bygninger. IECC opdateres hvert tredje år for at inkorporere de nyeste metoder og teknologier inden for energibesparelse.

IECC – Hvorfor du bør være opmærksom

IECC er bredt vedtaget af stater og kommuner i hele USA. IECC dækker forskellige aspekter af energiforbrug, herunder bygningsklimaskærmen (vægge, tage og vinduer), varme- og kølesystemer og belysningssystemer.

IECC foreskriver specifikke lysstyringer, såsom tilstedeværelsessensorer, for at minimere energispild i ubesatte rum i forskellige områder.

ANSI/ASHRAE/IES Standard 90.1, energistandard for websteder og bygninger undtaget lavhuse med boliger, er en bredt anerkendt energistandard udgivet af American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).

ASHRAE 90.1 – Hvorfor du bør være opmærksom

ASHRAE 90.1 bruges som reference for bygningsenergikoder i hele USA og fungerer som en overholdelsesvej inden for IECC, som skitserer minimumskrav til energieffektiv ydeevne for erhvervsbygningskomponenter, herunder bygningsklimaskærme, VVS-systemer, vandvarmesystemer og belysningssystemer.

ASHRAE 90.1-standarden specificerer maksimalt tilladte lysstrømtætheder og minimumskrav til lysstyring, herunder brugen af tilstedeværelsessensorer i specifikke områder.

Title 24, del 6 af Californiens bygningsstandardkode, officielt kendt som energieffektivitetsstandarderne for boliger og erhvervsbygninger, administreres af Californiens energikommission og opdateres periodisk for at afspejle nye energieffektivitetsteknologier og metoder.

Title 24 – Hvorfor du bør være opmærksom

Title 24 er kendt for sine strenge krav, der ofte betragtes som strengere end dem, der findes i mange andre energikoder i USA. Title 24 foreskriver strenge energiydeevnestandarder for alle aspekter af bygningskonstruktionen, herunder opvarmning, ventilation, aircondition (HVAC), vandopvarmning og belysning.

Title 24 kræver installation af tilstedeværelsessensorer, der justerer belysningen baseret på rummets besættelse i specifikke områder af erhvervsbygninger for at sikre, at energi ikke spildes.

Energikodetilpasning efter stat

Udvid for at se den detaljerede tabel ↓

StatNuværende erhvervskodeksErhvervskodeks effektivitetskategori
Alabama90.1-201390.1-2013
AlaskaIngen statsdækkendeIntet statsdækkende kodeks
ArizonaLokalt selvstyre<90.1-2007
Arkansas2009 IECC og 90.1-200790.1-2007
Californien2022 bygningsenergieffektivitetsstandarder90.1-2019
ColoradoLokalt selvstyreIntet statsdækkende kodeks
Connecticut2021 IECC og 90.1-201990.1-2019
Delaware2018 IECC og 90.1-201690.1-2013
District of Columbia90.1-2013^90.1-2019
Florida2021 IECC og 90.1-2019^90.1-2016
Georgia2015 IECC og 90.1-2013^90.1-2013
HawaiiLokalt selvstyre90.1-2013
Idaho2018 IECC og 90.1-201690.1-2013
Illinois2021 IECC og 90.1-201990.1-2019
Indiana90.1-200790.1-2007
Iowa2012 IECC og 90.1-201090.1-2007
KansasLokalt selvstyreIntet statsdækkende kodeks
Kentucky2012 IECC og 90.1-201090.1-2007
Louisiana2021 IECC og 90.1-2019^90.1-2016
Maine2015 IECC og 90.1-201390.1-2013
Maryland2021 IECC og 90.1-2019^90.1-2019
Massachusetts2018 IECC og 90.1-2016^90.1-2019
Michigan2015 IECC og 90.1-2013^90.1-2013
Minnesota90.1-2019^90.1-2019
MississippiIngen statsdækkendeIntet statsdækkende kodeks
MissouriLokalt selvstyreIntet statsdækkende kodeks
Montana2021 IECC og 90.1-201990.1-2019
Nebraska2018 IECC og 90.1-201690.1-2013
Nevada2018 IECC og 90.1-201690.1-2013
New Hampshire2018 IECC og 90.1-2016^90.1-2013
New Jersey90.1-201990.1-2019
New Mexico2021 IECC og 90.1-2019^90.1-2019
New York2018 IECC og 90.1-2016^90.1-2016
North Carolina2015 IECC og 90.1-2013^90.1-2010
North DakotaLokalt selvstyreIntet statsdækkende kodeks
Ohio2021 IECC og 90.1-2019^90.1-2016
Oklahoma2006 IECC og 90.1-2004<90.1-2007
Oregon90.1-201990.1-2019
Pennsylvania2018 IECC og 90.1-201690.1-2013
Rhode Island2018 IECC og 90.1-2016^90.1-2013
South Carolina2009 IECC og 90.1-200790.1-2007
South DakotaLokalt selvstyreIntet statsdækkende kodeks
Tennessee2021 IECC og 90.1-201390.1-2007
Texas2015 IECC og 90.1-201390.1-2013
Utah2021 IECC og 90.1-2019^90.1-2019
Vermont2021 IECC og 90.1-2019^90.1-2019
Virginia2021 IECC og 90.1-2019^90.1-2019
Washington2018 Washington State Energy Code90.1-2019
Tennessee2012 IECC og 90.1-201090.1-2007
Texas2015 IECC og 90.1-201390.1-2013
Utah2021 IECC og 90.1-2019^90.1-2019
Vermont2018 IECC og 90.1-2016^90.1-2019
Virginia2021 IECC og 90.1-2019^90.1-2019
Washington2018 Washington State Energy Code90.1-2019
West Virginia90.1-201390.1-2013
Wisconsin2015 IECC og 90.1-2013^90.1-2010
WyomingLokalt selvstyreIntet statsdækkende kodeks
  • ^ Når en ændring, der påvirker energieffektiviteten, kan kvantificeres ved hjælp af DOE Prototype Building Models, blev den medtaget i analysen.
  • For stater, der vedtager både IECC og 90.1, analyseres IECC-koden normalt som statens gældende kode i denne undersøgelse, undtagen for stater med omfattende ændringer af IECC.

Sensoreløsninger

Find ud af, hvordan Rayzeek kan løse dine energibesparelsesudfordringer.

Se alle tilbud

Design Guide Key Concepts for Private Offices

Designing an energy-efficient lighting control solution for private offices involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.

In a storage room, the primary areas that require lighting are the main walkways and the individual aisles between shelves. Here are some guidelines to follow:

  • Main Walkways: Install ceiling occupancy sensors at regular intervals along the main walkways. These sensors should be set to Auto ON and Full OFF mode, ensuring that lights turn on automatically when someone enters the walkway and turn off when the area is vacant.
  • Individual Aisles: For individual aisles between shelves, consider installing wall occupancy sensors at the entrance of each aisle. These sensors can detect when someone enters the aisle and turn on the lights accordingly. Given the sporadic usage of these aisles, the sensors should be set to Manual ON and Full OFF mode. This means that the lights will only turn on when manually switched on but will turn off automatically when the aisle is vacant.
  • Entrance Area: The entrance area of the storage room should have a wall sensor switch that allows manual control of all lighting in the room. This switch can be used to turn all lights on or off as needed, providing an additional layer of control.
  • Sensor Placement Considerations: When placing sensors, ensure they are not located near air vents or other sources of movement that could trigger false positives. Also, ensure that the sensors’ field of view is not obstructed by shelves or stored items.
  • Sensor Height: Consider the height of the sensor installation. Sensors should be installed at a height that allows for optimal coverage of the room, taking into account the height of stored items.
  • Manuel kontrol: Incorporate manual controls to allow users to turn ON/OFF all lighting when needed. This can be particularly useful in storage rooms where lighting may be required for extended periods during inventory checks or reorganization tasks.

Væg sensorafbrydere

RZ020/021 bevægelsessensorafbrydere

  • 2-trådet, 3-trådet, 4-trådet tilslutningsmuligheder
  • Tilstedeværelse, fravær, manuel TÆND/SLUK
  • Justerbar tidsforsinkelse og omgivende lyskontrol

Multi-location trådløse vægsensorer

RZ020A/021A + RZ022W sæt

  • Fasttilsluttet RZ021A/022A tilstedeværelses sensorafbryder
  • Trådløs ledsagerafbryder (RZ022W) til multi-location kontrol

Lofttilstedeværelsessensorer

RZ036

  • Fasttilsluttede tilstedeværelsessensorer
  • Auto TÆND, auto SLUK
  • Net- og lavspænding tilgængelig

Kernefunktioner inkluderet:

  • Integreret manuel TÆND/SLUK-kontrol for al belysning
  • Fraværelsessensorer (kun manuel TÆND): Lys skal kun tændes manuelt
  • Justerbar tidsforsinkelse, lyset slukkes automatisk helt efter 15 minutter
  • Ekstra: multi-location trådløse sæt til at udvide kontrolområdet uden omlægning af ledninger
  • Ekstra: flere tilslutningsmuligheder tilgængelige for både nybyggeri og renoveringsprojekter.

Opfylder de obligatoriske bestemmelser

IECC – 2011

C405.2.1 Beboersensorkontroller

Beboersensorkontroller skal installeres for at styre lyset i rummet.

C405.2.1.1 Beboersensorkontrolfunktioner

  • Manuel tænd eller delvis tænd med højst 50% effekt.
  • Fuldstændig sluk inden for 20 minutter efter alle beboere har forladt rummet
  • En manuel kontrol til at slukke lyset.

ASHRAE 90.1 – 2022

9.4.1.1 a Local control

There shall be one or more manual lighting control device that provides ON and OFF control
of all lighting in the space.

9.4.1.1 H Automatisk fuldstændig SLUK-kontrol

Al belysning i rummet skal automatisk slukkes inden for 20 minutter efter alle beboere har forladt rummet

Additionally, for storage rooms with sizes <50 ft2:

9.4.1.1 b Restricted to manual ON

None of the lighting shall be automatically turned on

Title 24 – 2022

130.1 (a) Manuelle arealkontroller.

Hvert område afgrænset af loftshøje skillevægge skal have belysningskontroller, der tillader, at belysningen i dette område manuelt kan tændes og slukkes.

130.1 (c) SLUK-kontroller.

Belysning skal styres med beboersensorer for automatisk at slukke al belysning inden for 20 minutter eller mindre efter kontrolzonen er ubeboet, som skal fungere enten som:

  • A. Beboersensorer (hvis 130.1(b) ikke kræver at have flerniveaubelysningskontroller); eller
  • B. Delvis TÆND-beboersensorer, eller
  • C. Bevægelsessensorer, hvor al belysning kun reagerer på manuel TÆND-input

Lad os høre dig.

Lad Rayzeek hjælpe med at designe og levere en skræddersyet energibesparende belysningsløsning til dig.

    Danish