Discover the energy-saving potential of storage rooms with Rayzeek’s occupancy sensor design guide.

Maximize Energy Efficiency in Storage Rooms with Occupancy Sensors
Storage rooms, often overlooked, are integral parts of commercial buildings. These spaces are typically filled with shelves, boxes, and various items, and are used for storing supplies, equipment, or archived documents. Lighting in these areas is crucial for visibility and safety, but it can also be a significant source of energy waste. Traditional lighting systems in storage rooms are often left on unnecessarily, leading to high energy consumption and costs.
Moreover, storage rooms are usually equipped with fluorescent or LED lights, which, while energy-efficient, can still consume a considerable amount of power when left on for extended periods. The sporadic and unpredictable nature of storage room usage further exacerbates this issue, as lights are often left on even when the room is unoccupied, leading to unnecessary energy waste.
This energy wastage can be mitigated by using occupancy sensors. These devices automatically control lighting based on the presence or absence of people, ensuring lights are only on when needed. By installing occupancy sensors in storage rooms, businesses can significantly reduce their energy consumption, lower their utility bills, and contribute to a more sustainable environment.
Rispetta le normative energetiche

L'International Energy Conservation Code (IECC) è un codice modello sviluppato dall'International Code Council (ICC) per stabilire requisiti minimi di progettazione e costruzione per l'efficienza energetica degli edifici. L'IECC viene aggiornato ogni tre anni per incorporare le ultime pratiche e tecnologie di risparmio energetico.
IECC, perché dovrebbe interessarti
L'IECC è ampiamente adottato da stati e comuni in tutti gli Stati Uniti. L'IECC copre vari aspetti del consumo energetico, incluso l'involucro edilizio (pareti, tetti e finestre), i sistemi di riscaldamento e raffreddamento e i sistemi di illuminazione.
L'IECC impone controlli di illuminazione specifici, come i sensori di presenza, per minimizzare gli sprechi energetici negli spazi non occupati in varie aree.

La norma ANSI/ASHRAE/IES 90.1, Energy Standard for Sites and Buildings Except Low-Rise Residential Buildings, è uno standard energetico ampiamente riconosciuto pubblicato dall'American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).
ASHRAE 90.1, perché dovrebbe interessarti
L'ASHRAE 90.1 viene utilizzato come punto di riferimento per le normative energetiche edilizie in tutti gli Stati Uniti e serve come percorso di conformità all'interno dell'IECC, che delinea i requisiti minimi per le prestazioni energeticamente efficienti dei componenti degli edifici commerciali, inclusi involucri edilizi, sistemi HVAC, sistemi di riscaldamento dell'acqua e sistemi di illuminazione.
La norma ASHRAE 90.1 specifica massime densità di potenza illuminante consentite e requisiti minimi di controllo dell'illuminazione, inclusa l'uso di sensori di presenza in aree specifiche.

Title 24, parte 6 del California Building Standards Code, ufficialmente noto come Building Energy Efficiency Standards for Residential and Nonresidential Buildings, il Title 24 è amministrato dalla California Energy Commission e viene aggiornato periodicamente per riflettere nuove tecnologie e metodi di efficienza energetica.
Title 24, perché dovrebbe interessarti
Il Title 24 è noto per i suoi requisiti rigorosi, spesso considerati più stringenti di quelli presenti in molte altre normative energetiche negli Stati Uniti. Il Title 24 impone standard rigorosi sulle prestazioni energetiche per tutti gli aspetti della costruzione edilizia, che includono riscaldamento, ventilazione, condizionamento dell'aria (HVAC), riscaldamento dell'acqua e illuminazione.
Il Title 24 richiede l'installazione di sensori di presenza che regolano l'illuminazione in base all'occupazione della stanza in aree specifiche degli edifici commerciali per garantire che l'energia non venga sprecata.
Adozione delle normative energetiche per stato

Espandi per vedere la tabella dettagliata ↓
| Stato | Codice commerciale attuale | Categoria di efficienza del codice commerciale |
|---|---|---|
| Alabama | 90.1-2013 | 90.1-2013 |
| Alaska | Nessuno a livello statale | Nessun codice a livello statale |
| Arizona | Autonomia locale | <90.1-2007 |
| Arkansas | 2009 IECC e 90.1-2007 | 90.1-2007 |
| California | Standard di efficienza energetica edilizia 2022 | 90.1-2019 |
| Colorado | Autonomia locale | Nessun codice a livello statale |
| Connecticut | 2021 IECC e 90.1-2019 | 90.1-2019 |
| Delaware | 2018 IECC e 90.1-2016 | 90.1-2013 |
| Distretto di Columbia | 90.1-2013^ | 90.1-2019 |
| Florida | 2021 IECC e 90.1-2019^ | 90.1-2016 |
| Georgia | 2015 IECC e 90.1-2013^ | 90.1-2013 |
| Hawaii | Autonomia locale | 90.1-2013 |
| Idaho | 2018 IECC e 90.1-2016 | 90.1-2013 |
| Illinois | 2021 IECC e 90.1-2019 | 90.1-2019 |
| Indiana | 90.1-2007 | 90.1-2007 |
| Iowa | 2012 IECC e 90.1-2010 | 90.1-2007 |
| Kansas | Autonomia locale | Nessun codice a livello statale |
| Kentucky | 2012 IECC e 90.1-2010 | 90.1-2007 |
| Louisiana | 2021 IECC e 90.1-2019^ | 90.1-2016 |
| Maine | IECC 2015 e 90.1-2013 | 90.1-2013 |
| Maryland | 2021 IECC e 90.1-2019^ | 90.1-2019 |
| Massachusetts | IECC 2018 e 90.1-2016^ | 90.1-2019 |
| Michigan | 2015 IECC e 90.1-2013^ | 90.1-2013 |
| Minnesota | 90.1-2019^ | 90.1-2019 |
| Mississippi | Nessuno a livello statale | Nessun codice a livello statale |
| Missouri | Autonomia locale | Nessun codice a livello statale |
| Montana | 2021 IECC e 90.1-2019 | 90.1-2019 |
| Nebraska | 2018 IECC e 90.1-2016 | 90.1-2013 |
| Nevada | 2018 IECC e 90.1-2016 | 90.1-2013 |
| New Hampshire | IECC 2018 e 90.1-2016^ | 90.1-2013 |
| New Jersey | 90.1-2019 | 90.1-2019 |
| New Mexico | 2021 IECC e 90.1-2019^ | 90.1-2019 |
| New York | IECC 2018 e 90.1-2016^ | 90.1-2016 |
| North Carolina | 2015 IECC e 90.1-2013^ | 90.1-2010 |
| North Dakota | Autonomia locale | Nessun codice a livello statale |
| Ohio | 2021 IECC e 90.1-2019^ | 90.1-2016 |
| Oklahoma | IECC 2006 e 90.1-2004 | <90.1-2007 |
| Oregon | 90.1-2019 | 90.1-2019 |
| Pennsylvania | 2018 IECC e 90.1-2016 | 90.1-2013 |
| Rhode Island | IECC 2018 e 90.1-2016^ | 90.1-2013 |
| South Carolina | 2009 IECC e 90.1-2007 | 90.1-2007 |
| South Dakota | Autonomia locale | Nessun codice a livello statale |
| Tennessee | IECC 2021 e 90.1-2013 | 90.1-2007 |
| Texas | IECC 2015 e 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC e 90.1-2019^ | 90.1-2019 |
| Vermont | 2021 IECC e 90.1-2019^ | 90.1-2019 |
| Virginia | 2021 IECC e 90.1-2019^ | 90.1-2019 |
| Washington | Codice energetico dello stato di Washington 2018 | 90.1-2019 |
| Tennessee | 2012 IECC e 90.1-2010 | 90.1-2007 |
| Texas | IECC 2015 e 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC e 90.1-2019^ | 90.1-2019 |
| Vermont | IECC 2018 e 90.1-2016^ | 90.1-2019 |
| Virginia | 2021 IECC e 90.1-2019^ | 90.1-2019 |
| Washington | Codice energetico dello stato di Washington 2018 | 90.1-2019 |
| West Virginia | 90.1-2013 | 90.1-2013 |
| Wisconsin | 2015 IECC e 90.1-2013^ | 90.1-2010 |
| Wyoming | Autonomia locale | Nessun codice a livello statale |
- ^ Quando un emendamento che influisce sull'efficienza energetica può essere quantificato utilizzando i DOE Prototype Building Models, è stato incluso nell'analisi.
- Per gli stati che adottano sia l'IECC che il 90.1, il codice IECC è generalmente analizzato come il codice attuale dello stato in questo studio, ad eccezione degli stati con emendamenti estesi all'IECC.
Design Guide Key Concepts for Private Offices
Designing an energy-efficient lighting control solution for private offices involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.

In a storage room, the primary areas that require lighting are the main walkways and the individual aisles between shelves. Here are some guidelines to follow:
- Main Walkways: Install ceiling occupancy sensors at regular intervals along the main walkways. These sensors should be set to Auto ON and Full OFF mode, ensuring that lights turn on automatically when someone enters the walkway and turn off when the area is vacant.
- Individual Aisles: For individual aisles between shelves, consider installing wall occupancy sensors at the entrance of each aisle. These sensors can detect when someone enters the aisle and turn on the lights accordingly. Given the sporadic usage of these aisles, the sensors should be set to Manual ON and Full OFF mode. This means that the lights will only turn on when manually switched on but will turn off automatically when the aisle is vacant.
- Entrance Area: The entrance area of the storage room should have a wall sensor switch that allows manual control of all lighting in the room. This switch can be used to turn all lights on or off as needed, providing an additional layer of control.
- Sensor Placement Considerations: When placing sensors, ensure they are not located near air vents or other sources of movement that could trigger false positives. Also, ensure that the sensors’ field of view is not obstructed by shelves or stored items.
- Sensor Height: Consider the height of the sensor installation. Sensors should be installed at a height that allows for optimal coverage of the room, taking into account the height of stored items.
- Controllo Manuale: Incorporate manual controls to allow users to turn ON/OFF all lighting when needed. This can be particularly useful in storage rooms where lighting may be required for extended periods during inventory checks or reorganization tasks.
Prodotti e Soluzioni in Evidenza
Caratteristiche principali incluse:
- Controllo manuale integrato ACCENDI/SPEGNI per tutte le luci
- Sensori di assenza (Solo ACCENSIONE manuale): Le luci devono essere accese solo manualmente
- Ritardo temporale regolabile, le luci vengono automaticamente spente completamente dopo 15 minuti
- Aggiuntivo: kit wireless multi-posizione per espandere il raggio di controllo senza cablaggio aggiuntivo
- Aggiuntivo: multiple opzioni di cablaggio disponibili per nuove costruzioni e progetti di retrofit.

Rispetta le Disposizioni Obbligatorie
IECC – 2011
C405.2.1 Controlli a sensore di occupazione
I controlli a sensore di occupazione devono essere installati per controllare le luci nello spazio.
C405.2.1.1 Funzioni dei controlli a sensore di occupazione
- Accensione manuale o parziale con potenza non superiore al 50%.
- Spegimento completo entro 20 minuti dopo che tutti gli occupanti hanno lasciato lo spazio
- Un controllo manuale per spegnere le luci.
ASHRAE 90.1 – 2022
9.4.1.1 a Local control
There shall be one or more manual lighting control device that provides ON and OFF control
of all lighting in the space.
9.4.1.1 H Controllo di spegnimento completo automatico
Tutte le luci nello spazio devono essere automaticamente spente entro 20 minuti dal momento in cui tutti gli occupanti lasciano lo spazio
Additionally, for storage rooms with sizes <50 ft2:
9.4.1.1 b Restricted to manual ON
None of the lighting shall be automatically turned on
Title 24 – 2022
130.1 (a) Controlli di area manuali.
Ogni area delimitata da pareti divisore alte fino al soffitto deve disporre di controlli per l'illuminazione che consentano di accendere e spegnere manualmente le luci in quell'area.
130.1 (c) Controlli di SPEGNIMENTO.
L'illuminazione deve essere controllata con controlli a sensore di occupazione per spegnere automaticamente tutte le luci in 20 minuti o meno dopo che la zona di controllo non è occupata, che devono funzionare come:
- A. Controlli a sensore di occupazione (se 130.1(b) non richiede controlli per illuminazione multi-livello); oppure
- B. Controlli a sensore di occupazione ad ACCENSIONE PARZIALE, oppure
- C. Controlli di rilevamento della presenza (vacancy), dove tutta l'illuminazione risponde solo a un ingresso manuale di ACCENSIONE