Discover the energy-saving potential of storage rooms with Rayzeek’s occupancy sensor design guide.

Maximize Energy Efficiency in Storage Rooms with Occupancy Sensors

Storage rooms, often overlooked, are integral parts of commercial buildings. These spaces are typically filled with shelves, boxes, and various items, and are used for storing supplies, equipment, or archived documents. Lighting in these areas is crucial for visibility and safety, but it can also be a significant source of energy waste. Traditional lighting systems in storage rooms are often left on unnecessarily, leading to high energy consumption and costs.

Moreover, storage rooms are usually equipped with fluorescent or LED lights, which, while energy-efficient, can still consume a considerable amount of power when left on for extended periods. The sporadic and unpredictable nature of storage room usage further exacerbates this issue, as lights are often left on even when the room is unoccupied, leading to unnecessary energy waste.

This energy wastage can be mitigated by using occupancy sensors. These devices automatically control lighting based on the presence or absence of people, ensuring lights are only on when needed. By installing occupancy sensors in storage rooms, businesses can significantly reduce their energy consumption, lower their utility bills, and contribute to a more sustainable environment.

Rispetta le normative energetiche

L'International Energy Conservation Code (IECC) è un codice modello sviluppato dall'International Code Council (ICC) per stabilire requisiti minimi di progettazione e costruzione per l'efficienza energetica degli edifici. L'IECC viene aggiornato ogni tre anni per incorporare le ultime pratiche e tecnologie di risparmio energetico.

IECC, perché dovrebbe interessarti

L'IECC è ampiamente adottato da stati e comuni in tutti gli Stati Uniti. L'IECC copre vari aspetti del consumo energetico, incluso l'involucro edilizio (pareti, tetti e finestre), i sistemi di riscaldamento e raffreddamento e i sistemi di illuminazione.

L'IECC impone controlli di illuminazione specifici, come i sensori di presenza, per minimizzare gli sprechi energetici negli spazi non occupati in varie aree.

La norma ANSI/ASHRAE/IES 90.1, Energy Standard for Sites and Buildings Except Low-Rise Residential Buildings, è uno standard energetico ampiamente riconosciuto pubblicato dall'American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).

ASHRAE 90.1, perché dovrebbe interessarti

L'ASHRAE 90.1 viene utilizzato come punto di riferimento per le normative energetiche edilizie in tutti gli Stati Uniti e serve come percorso di conformità all'interno dell'IECC, che delinea i requisiti minimi per le prestazioni energeticamente efficienti dei componenti degli edifici commerciali, inclusi involucri edilizi, sistemi HVAC, sistemi di riscaldamento dell'acqua e sistemi di illuminazione.

La norma ASHRAE 90.1 specifica massime densità di potenza illuminante consentite e requisiti minimi di controllo dell'illuminazione, inclusa l'uso di sensori di presenza in aree specifiche.

Title 24, parte 6 del California Building Standards Code, ufficialmente noto come Building Energy Efficiency Standards for Residential and Nonresidential Buildings, il Title 24 è amministrato dalla California Energy Commission e viene aggiornato periodicamente per riflettere nuove tecnologie e metodi di efficienza energetica.

Title 24, perché dovrebbe interessarti

Il Title 24 è noto per i suoi requisiti rigorosi, spesso considerati più stringenti di quelli presenti in molte altre normative energetiche negli Stati Uniti. Il Title 24 impone standard rigorosi sulle prestazioni energetiche per tutti gli aspetti della costruzione edilizia, che includono riscaldamento, ventilazione, condizionamento dell'aria (HVAC), riscaldamento dell'acqua e illuminazione.

Il Title 24 richiede l'installazione di sensori di presenza che regolano l'illuminazione in base all'occupazione della stanza in aree specifiche degli edifici commerciali per garantire che l'energia non venga sprecata.

Adozione delle normative energetiche per stato

Espandi per vedere la tabella dettagliata ↓

StatoCodice commerciale attualeCategoria di efficienza del codice commerciale
Alabama90.1-201390.1-2013
AlaskaNessuno a livello stataleNessun codice a livello statale
ArizonaAutonomia locale<90.1-2007
Arkansas2009 IECC e 90.1-200790.1-2007
CaliforniaStandard di efficienza energetica edilizia 202290.1-2019
ColoradoAutonomia localeNessun codice a livello statale
Connecticut2021 IECC e 90.1-201990.1-2019
Delaware2018 IECC e 90.1-201690.1-2013
Distretto di Columbia90.1-2013^90.1-2019
Florida2021 IECC e 90.1-2019^90.1-2016
Georgia2015 IECC e 90.1-2013^90.1-2013
HawaiiAutonomia locale90.1-2013
Idaho2018 IECC e 90.1-201690.1-2013
Illinois2021 IECC e 90.1-201990.1-2019
Indiana90.1-200790.1-2007
Iowa2012 IECC e 90.1-201090.1-2007
KansasAutonomia localeNessun codice a livello statale
Kentucky2012 IECC e 90.1-201090.1-2007
Louisiana2021 IECC e 90.1-2019^90.1-2016
MaineIECC 2015 e 90.1-201390.1-2013
Maryland2021 IECC e 90.1-2019^90.1-2019
MassachusettsIECC 2018 e 90.1-2016^90.1-2019
Michigan2015 IECC e 90.1-2013^90.1-2013
Minnesota90.1-2019^90.1-2019
MississippiNessuno a livello stataleNessun codice a livello statale
MissouriAutonomia localeNessun codice a livello statale
Montana2021 IECC e 90.1-201990.1-2019
Nebraska2018 IECC e 90.1-201690.1-2013
Nevada2018 IECC e 90.1-201690.1-2013
New HampshireIECC 2018 e 90.1-2016^90.1-2013
New Jersey90.1-201990.1-2019
New Mexico2021 IECC e 90.1-2019^90.1-2019
New YorkIECC 2018 e 90.1-2016^90.1-2016
North Carolina2015 IECC e 90.1-2013^90.1-2010
North DakotaAutonomia localeNessun codice a livello statale
Ohio2021 IECC e 90.1-2019^90.1-2016
OklahomaIECC 2006 e 90.1-2004<90.1-2007
Oregon90.1-201990.1-2019
Pennsylvania2018 IECC e 90.1-201690.1-2013
Rhode IslandIECC 2018 e 90.1-2016^90.1-2013
South Carolina2009 IECC e 90.1-200790.1-2007
South DakotaAutonomia localeNessun codice a livello statale
TennesseeIECC 2021 e 90.1-201390.1-2007
TexasIECC 2015 e 90.1-201390.1-2013
Utah2021 IECC e 90.1-2019^90.1-2019
Vermont2021 IECC e 90.1-2019^90.1-2019
Virginia2021 IECC e 90.1-2019^90.1-2019
WashingtonCodice energetico dello stato di Washington 201890.1-2019
Tennessee2012 IECC e 90.1-201090.1-2007
TexasIECC 2015 e 90.1-201390.1-2013
Utah2021 IECC e 90.1-2019^90.1-2019
VermontIECC 2018 e 90.1-2016^90.1-2019
Virginia2021 IECC e 90.1-2019^90.1-2019
WashingtonCodice energetico dello stato di Washington 201890.1-2019
West Virginia90.1-201390.1-2013
Wisconsin2015 IECC e 90.1-2013^90.1-2010
WyomingAutonomia localeNessun codice a livello statale
  • ^ Quando un emendamento che influisce sull'efficienza energetica può essere quantificato utilizzando i DOE Prototype Building Models, è stato incluso nell'analisi.
  • Per gli stati che adottano sia l'IECC che il 90.1, il codice IECC è generalmente analizzato come il codice attuale dello stato in questo studio, ad eccezione degli stati con emendamenti estesi all'IECC.

Soluzioni per Sensori

Scopri come Rayzeek può risolvere le tue sfide di risparmio energetico.

Visualizza Tutte le Offerte

Design Guide Key Concepts for Private Offices

Designing an energy-efficient lighting control solution for private offices involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.

In a storage room, the primary areas that require lighting are the main walkways and the individual aisles between shelves. Here are some guidelines to follow:

  • Main Walkways: Install ceiling occupancy sensors at regular intervals along the main walkways. These sensors should be set to Auto ON and Full OFF mode, ensuring that lights turn on automatically when someone enters the walkway and turn off when the area is vacant.
  • Individual Aisles: For individual aisles between shelves, consider installing wall occupancy sensors at the entrance of each aisle. These sensors can detect when someone enters the aisle and turn on the lights accordingly. Given the sporadic usage of these aisles, the sensors should be set to Manual ON and Full OFF mode. This means that the lights will only turn on when manually switched on but will turn off automatically when the aisle is vacant.
  • Entrance Area: The entrance area of the storage room should have a wall sensor switch that allows manual control of all lighting in the room. This switch can be used to turn all lights on or off as needed, providing an additional layer of control.
  • Sensor Placement Considerations: When placing sensors, ensure they are not located near air vents or other sources of movement that could trigger false positives. Also, ensure that the sensors’ field of view is not obstructed by shelves or stored items.
  • Sensor Height: Consider the height of the sensor installation. Sensors should be installed at a height that allows for optimal coverage of the room, taking into account the height of stored items.
  • Controllo Manuale: Incorporate manual controls to allow users to turn ON/OFF all lighting when needed. This can be particularly useful in storage rooms where lighting may be required for extended periods during inventory checks or reorganization tasks.

Interruttori a Sensore a Parete

Interruttori a Sensore di Movimento RZ020/021

  • Opzioni di cablaggio a 2 fili, 3 fili, 4 fili
  • Presenza, Assenza, ACCENDI/SPEGNI Manuale
  • Ritardo temporale regolabile e controllo della luce ambientale

Sensori a Parete Wireless Multi-Posizione

Kit RZ020A/021A + RZ022W

  • Interruttore a sensore di presenza cablato RZ021A/022A
  • Interruttore companion wireless (RZ022W) per il controllo multi-posizione

Sensori di Presenza a Soffitto

RZ036

  • Sensori di presenza cablati
  • ACCENSIONE automatica, SPEGNIMENTO automatico
  • Disponibili a tensione di linea e bassa tensione

Caratteristiche principali incluse:

  • Controllo manuale integrato ACCENDI/SPEGNI per tutte le luci
  • Sensori di assenza (Solo ACCENSIONE manuale): Le luci devono essere accese solo manualmente
  • Ritardo temporale regolabile, le luci vengono automaticamente spente completamente dopo 15 minuti
  • Aggiuntivo: kit wireless multi-posizione per espandere il raggio di controllo senza cablaggio aggiuntivo
  • Aggiuntivo: multiple opzioni di cablaggio disponibili per nuove costruzioni e progetti di retrofit.

Rispetta le Disposizioni Obbligatorie

IECC – 2011

C405.2.1 Controlli a sensore di occupazione

I controlli a sensore di occupazione devono essere installati per controllare le luci nello spazio.

C405.2.1.1 Funzioni dei controlli a sensore di occupazione

  • Accensione manuale o parziale con potenza non superiore al 50%.
  • Spegimento completo entro 20 minuti dopo che tutti gli occupanti hanno lasciato lo spazio
  • Un controllo manuale per spegnere le luci.

ASHRAE 90.1 – 2022

9.4.1.1 a Local control

There shall be one or more manual lighting control device that provides ON and OFF control
of all lighting in the space.

9.4.1.1 H Controllo di spegnimento completo automatico

Tutte le luci nello spazio devono essere automaticamente spente entro 20 minuti dal momento in cui tutti gli occupanti lasciano lo spazio

Additionally, for storage rooms with sizes <50 ft2:

9.4.1.1 b Restricted to manual ON

None of the lighting shall be automatically turned on

Title 24 – 2022

130.1 (a) Controlli di area manuali.

Ogni area delimitata da pareti divisore alte fino al soffitto deve disporre di controlli per l'illuminazione che consentano di accendere e spegnere manualmente le luci in quell'area.

130.1 (c) Controlli di SPEGNIMENTO.

L'illuminazione deve essere controllata con controlli a sensore di occupazione per spegnere automaticamente tutte le luci in 20 minuti o meno dopo che la zona di controllo non è occupata, che devono funzionare come:

  • A. Controlli a sensore di occupazione (se 130.1(b) non richiede controlli per illuminazione multi-livello); oppure
  • B. Controlli a sensore di occupazione ad ACCENSIONE PARZIALE, oppure
  • C. Controlli di rilevamento della presenza (vacancy), dove tutta l'illuminazione risponde solo a un ingresso manuale di ACCENSIONE