Conference Rooms

Discover the energy-saving potential of your conference room with Rayzeek’s occupancy sensor design guide.

Maximize Energy Efficiency in Conference Rooms with Occupancy Sensors

Conference rooms are integral to the functioning of any commercial building, serving as the hub for meetings, presentations, and brainstorming sessions. These rooms are often equipped with high-intensity lighting to ensure visibility during presentations and discussions. However, due to their intermittent usage, they are prone to high energy wastage. Lights are often left on when the room is vacant, leading to unnecessary energy consumption.

Moreover, the sporadic usage of conference rooms means that they often remain vacant for extended periods, leading to unnecessary energy consumption if the lights are left on. This wastage not only impacts the building’s energy efficiency but also contributes to higher operational costs.

With Rayzeek’s occupancy sensors, you can transform your conference room into an energy-efficient space, meeting the requirements of energy codes and contributing to a greener environment.

Overhold energikoderne

Den internationale energisparekodeks (IECC) er en modelkodeks udviklet af International Code Council (ICC) for at fastsætte minimumskrav til design og konstruktion for energieffektivitet i bygninger. IECC opdateres hvert tredje år for at inkorporere de nyeste metoder og teknologier inden for energibesparelse.

IECC – Hvorfor du bør være opmærksom

IECC er bredt vedtaget af stater og kommuner i hele USA. IECC dækker forskellige aspekter af energiforbrug, herunder bygningsklimaskærmen (vægge, tage og vinduer), varme- og kølesystemer og belysningssystemer.

IECC foreskriver specifikke lysstyringer, såsom tilstedeværelsessensorer, for at minimere energispild i ubesatte rum i forskellige områder.

ANSI/ASHRAE/IES Standard 90.1, energistandard for websteder og bygninger undtaget lavhuse med boliger, er en bredt anerkendt energistandard udgivet af American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).

ASHRAE 90.1 – Hvorfor du bør være opmærksom

ASHRAE 90.1 bruges som reference for bygningsenergikoder i hele USA og fungerer som en overholdelsesvej inden for IECC, som skitserer minimumskrav til energieffektiv ydeevne for erhvervsbygningskomponenter, herunder bygningsklimaskærme, VVS-systemer, vandvarmesystemer og belysningssystemer.

ASHRAE 90.1-standarden specificerer maksimalt tilladte lysstrømtætheder og minimumskrav til lysstyring, herunder brugen af tilstedeværelsessensorer i specifikke områder.

Title 24, del 6 af Californiens bygningsstandardkode, officielt kendt som energieffektivitetsstandarderne for boliger og erhvervsbygninger, administreres af Californiens energikommission og opdateres periodisk for at afspejle nye energieffektivitetsteknologier og metoder.

Title 24 – Hvorfor du bør være opmærksom

Title 24 er kendt for sine strenge krav, der ofte betragtes som strengere end dem, der findes i mange andre energikoder i USA. Title 24 foreskriver strenge energiydeevnestandarder for alle aspekter af bygningskonstruktionen, herunder opvarmning, ventilation, aircondition (HVAC), vandopvarmning og belysning.

Title 24 kræver installation af tilstedeværelsessensorer, der justerer belysningen baseret på rummets besættelse i specifikke områder af erhvervsbygninger for at sikre, at energi ikke spildes.

Energikodetilpasning efter stat

Udvid for at se den detaljerede tabel ↓

StatNuværende erhvervskodeksErhvervskodeks effektivitetskategori
Alabama90.1-201390.1-2013
AlaskaIngen statsdækkendeIntet statsdækkende kodeks
ArizonaLokalt selvstyre<90.1-2007
Arkansas2009 IECC og 90.1-200790.1-2007
Californien2022 bygningsenergieffektivitetsstandarder90.1-2019
ColoradoLokalt selvstyreIntet statsdækkende kodeks
Connecticut2021 IECC og 90.1-201990.1-2019
Delaware2018 IECC og 90.1-201690.1-2013
District of Columbia90.1-2013^90.1-2019
Florida2021 IECC og 90.1-2019^90.1-2016
Georgia2015 IECC og 90.1-2013^90.1-2013
HawaiiLokalt selvstyre90.1-2013
Idaho2018 IECC og 90.1-201690.1-2013
Illinois2021 IECC og 90.1-201990.1-2019
Indiana90.1-200790.1-2007
Iowa2012 IECC og 90.1-201090.1-2007
KansasLokalt selvstyreIntet statsdækkende kodeks
Kentucky2012 IECC og 90.1-201090.1-2007
Louisiana2021 IECC og 90.1-2019^90.1-2016
Maine2015 IECC og 90.1-201390.1-2013
Maryland2021 IECC og 90.1-2019^90.1-2019
Massachusetts2018 IECC og 90.1-2016^90.1-2019
Michigan2015 IECC og 90.1-2013^90.1-2013
Minnesota90.1-2019^90.1-2019
MississippiIngen statsdækkendeIntet statsdækkende kodeks
MissouriLokalt selvstyreIntet statsdækkende kodeks
Montana2021 IECC og 90.1-201990.1-2019
Nebraska2018 IECC og 90.1-201690.1-2013
Nevada2018 IECC og 90.1-201690.1-2013
New Hampshire2018 IECC og 90.1-2016^90.1-2013
New Jersey90.1-201990.1-2019
New Mexico2021 IECC og 90.1-2019^90.1-2019
New York2018 IECC og 90.1-2016^90.1-2016
North Carolina2015 IECC og 90.1-2013^90.1-2010
North DakotaLokalt selvstyreIntet statsdækkende kodeks
Ohio2021 IECC og 90.1-2019^90.1-2016
Oklahoma2006 IECC og 90.1-2004<90.1-2007
Oregon90.1-201990.1-2019
Pennsylvania2018 IECC og 90.1-201690.1-2013
Rhode Island2018 IECC og 90.1-2016^90.1-2013
South Carolina2009 IECC og 90.1-200790.1-2007
South DakotaLokalt selvstyreIntet statsdækkende kodeks
Tennessee2021 IECC og 90.1-201390.1-2007
Texas2015 IECC og 90.1-201390.1-2013
Utah2021 IECC og 90.1-2019^90.1-2019
Vermont2021 IECC og 90.1-2019^90.1-2019
Virginia2021 IECC og 90.1-2019^90.1-2019
Washington2018 Washington State Energy Code90.1-2019
Tennessee2012 IECC og 90.1-201090.1-2007
Texas2015 IECC og 90.1-201390.1-2013
Utah2021 IECC og 90.1-2019^90.1-2019
Vermont2018 IECC og 90.1-2016^90.1-2019
Virginia2021 IECC og 90.1-2019^90.1-2019
Washington2018 Washington State Energy Code90.1-2019
West Virginia90.1-201390.1-2013
Wisconsin2015 IECC og 90.1-2013^90.1-2010
WyomingLokalt selvstyreIntet statsdækkende kodeks
  • ^ Når en ændring, der påvirker energieffektiviteten, kan kvantificeres ved hjælp af DOE Prototype Building Models, blev den medtaget i analysen.
  • For stater, der vedtager både IECC og 90.1, analyseres IECC-koden normalt som statens gældende kode i denne undersøgelse, undtagen for stater med omfattende ændringer af IECC.

Sensoreløsninger

Find ud af, hvordan Rayzeek kan løse dine energibesparelsesudfordringer.

Se alle tilbud

Design Guide Key Concepts for Conference Rooms

Designing an energy-efficient lighting control solution for conference rooms involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.

Designing an energy-efficient lighting system for a conference room involves strategic placement of occupancy sensors to ensure comprehensive coverage. Here are some guidelines to consider:

  • Indgangsdækning: Install a wall-mounted sensor near the entrance to detect when someone enters or exits the room. This sensor should be positioned high enough to avoid obstruction from the open door and should not directly face the entrance to avoid false triggers from movement outside the room.
  • Table Coverage: Place a ceiling-mounted sensor above the conference table to detect occupancy in the main area of the room. This sensor should be positioned centrally to ensure comprehensive coverage.
  • Presentation Area Coverage: If your conference room has a dedicated presentation area, consider installing an additional wall-mounted sensor to cover this space. This sensor should be positioned to avoid any potential obstructions, such as screens or projectors.
  • Wall Control: Install a wall control unit near the entrance for manual override or adjustments of the lighting settings. This control should be easily accessible upon entering or exiting the room.
  • Avoidance of Obstructions and Interference: Ensure that sensors are not placed near air vents to prevent interference from air flow or vibrations. Also, consider the height and placement of furniture to avoid blocking the sensor’s field of view.
  • Integration with Existing Systems: Our occupancy sensors can be integrated with existing lighting systems for seamless operation. They can also be programmed to turn off all lights after a certain period of inactivity, further enhancing energy efficiency.

Væg sensorafbrydere

RZ020/021 bevægelsessensorafbrydere

  • 2-trådet, 3-trådet, 4-trådet tilslutningsmuligheder
  • Tilstedeværelse, fravær, manuel TÆND/SLUK
  • Justerbar tidsforsinkelse og omgivende lyskontrol

Multi-location trådløse vægsensorer

RZ020A/021A + RZ022W sæt

  • Fasttilsluttet RZ021A/022A tilstedeværelses sensorafbryder
  • Trådløs ledsagerafbryder (RZ022W) til multi-location kontrol

Lofttilstedeværelsessensorer

RZ036

  • Fasttilsluttede tilstedeværelsessensorer
  • Auto TÆND, auto SLUK
  • Net- og lavspænding tilgængelig

Kernefunktioner inkluderet:

  • Integreret manuel TÆND/SLUK-kontrol for al belysning
  • Fraværelsessensorer (kun manuel TÆND): Lys skal kun tændes manuelt
  • Justerbar tidsforsinkelse, lyset slukkes automatisk helt efter 15 minutter
  • Ekstra: multi-location trådløse sæt til at udvide kontrolområdet uden omlægning af ledninger
  • Ekstra: flere tilslutningsmuligheder tilgængelige for både nybyggeri og renoveringsprojekter.

Opfylder de obligatoriske bestemmelser

IECC – 2011

C405.2.1 Beboersensorkontroller

Beboersensorkontroller skal installeres for at styre lyset i rummet.

C405.2.1.1 Beboersensorkontrolfunktioner

  • Manuel tænd eller delvis tænd med højst 50% effekt.
  • Fuldstændig sluk inden for 20 minutter efter alle beboere har forladt rummet
  • En manuel kontrol til at slukke lyset.

ASHRAE 90.1 – 2022

9.4.1.1 a Local control

There shall be one or more manual lighting control device that provides ON and OFF control
of all lighting in the space.

9.4.1.1 b Restricted to manual ON

None of the lighting shall be automatically turned on

9.4.1.1 c Restricted to partial automatic ON

No more than 50% of the lighting power for the general lighting shall be allowed to be automatically turned on

** NOTE: At least one 9.4.1.1 b or 9.4.1.1 c shall be implemented.

9.4.1.1 h Automatic full OFF control

Al belysning i rummet skal automatisk slukkes inden for 20 minutter efter alle beboere har forladt rummet

Title 24 – 2022

130.1 (a) Manuelle arealkontroller.

Hvert område afgrænset af loftshøje skillevægge skal have belysningskontroller, der tillader, at belysningen i dette område manuelt kan tændes og slukkes.

130.1 (c) SLUK-kontroller.

Belysning skal styres med beboersensorer for automatisk at slukke al belysning inden for 20 minutter eller mindre efter kontrolzonen er ubeboet, som skal fungere enten som:

  • A. Beboersensorer (hvis 130.1(b) ikke kræver at have flerniveaubelysningskontroller); eller
  • B. Delvis TÆND-beboersensorer, eller
  • C. Bevægelsessensorer, hvor al belysning kun reagerer på manuel TÆND-input