Conference Rooms
Discover the energy-saving potential of your conference room with Rayzeek’s occupancy sensor design guide.

Maximize Energy Efficiency in Conference Rooms with Occupancy Sensors
Conference rooms are integral to the functioning of any commercial building, serving as the hub for meetings, presentations, and brainstorming sessions. These rooms are often equipped with high-intensity lighting to ensure visibility during presentations and discussions. However, due to their intermittent usage, they are prone to high energy wastage. Lights are often left on when the room is vacant, leading to unnecessary energy consumption.
Moreover, the sporadic usage of conference rooms means that they often remain vacant for extended periods, leading to unnecessary energy consumption if the lights are left on. This wastage not only impacts the building’s energy efficiency but also contributes to higher operational costs.
With Rayzeek’s occupancy sensors, you can transform your conference room into an energy-efficient space, meeting the requirements of energy codes and contributing to a greener environment.
Overhold energikoderne

Den internationale energisparekodeks (IECC) er en modelkodeks udviklet af International Code Council (ICC) for at fastsætte minimumskrav til design og konstruktion for energieffektivitet i bygninger. IECC opdateres hvert tredje år for at inkorporere de nyeste metoder og teknologier inden for energibesparelse.
IECC – Hvorfor du bør være opmærksom
IECC er bredt vedtaget af stater og kommuner i hele USA. IECC dækker forskellige aspekter af energiforbrug, herunder bygningsklimaskærmen (vægge, tage og vinduer), varme- og kølesystemer og belysningssystemer.
IECC foreskriver specifikke lysstyringer, såsom tilstedeværelsessensorer, for at minimere energispild i ubesatte rum i forskellige områder.

ANSI/ASHRAE/IES Standard 90.1, energistandard for websteder og bygninger undtaget lavhuse med boliger, er en bredt anerkendt energistandard udgivet af American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).
ASHRAE 90.1 – Hvorfor du bør være opmærksom
ASHRAE 90.1 bruges som reference for bygningsenergikoder i hele USA og fungerer som en overholdelsesvej inden for IECC, som skitserer minimumskrav til energieffektiv ydeevne for erhvervsbygningskomponenter, herunder bygningsklimaskærme, VVS-systemer, vandvarmesystemer og belysningssystemer.
ASHRAE 90.1-standarden specificerer maksimalt tilladte lysstrømtætheder og minimumskrav til lysstyring, herunder brugen af tilstedeværelsessensorer i specifikke områder.

Title 24, del 6 af Californiens bygningsstandardkode, officielt kendt som energieffektivitetsstandarderne for boliger og erhvervsbygninger, administreres af Californiens energikommission og opdateres periodisk for at afspejle nye energieffektivitetsteknologier og metoder.
Title 24 – Hvorfor du bør være opmærksom
Title 24 er kendt for sine strenge krav, der ofte betragtes som strengere end dem, der findes i mange andre energikoder i USA. Title 24 foreskriver strenge energiydeevnestandarder for alle aspekter af bygningskonstruktionen, herunder opvarmning, ventilation, aircondition (HVAC), vandopvarmning og belysning.
Title 24 kræver installation af tilstedeværelsessensorer, der justerer belysningen baseret på rummets besættelse i specifikke områder af erhvervsbygninger for at sikre, at energi ikke spildes.
Energikodetilpasning efter stat

Udvid for at se den detaljerede tabel ↓
| Stat | Nuværende erhvervskodeks | Erhvervskodeks effektivitetskategori |
|---|---|---|
| Alabama | 90.1-2013 | 90.1-2013 |
| Alaska | Ingen statsdækkende | Intet statsdækkende kodeks |
| Arizona | Lokalt selvstyre | <90.1-2007 |
| Arkansas | 2009 IECC og 90.1-2007 | 90.1-2007 |
| Californien | 2022 bygningsenergieffektivitetsstandarder | 90.1-2019 |
| Colorado | Lokalt selvstyre | Intet statsdækkende kodeks |
| Connecticut | 2021 IECC og 90.1-2019 | 90.1-2019 |
| Delaware | 2018 IECC og 90.1-2016 | 90.1-2013 |
| District of Columbia | 90.1-2013^ | 90.1-2019 |
| Florida | 2021 IECC og 90.1-2019^ | 90.1-2016 |
| Georgia | 2015 IECC og 90.1-2013^ | 90.1-2013 |
| Hawaii | Lokalt selvstyre | 90.1-2013 |
| Idaho | 2018 IECC og 90.1-2016 | 90.1-2013 |
| Illinois | 2021 IECC og 90.1-2019 | 90.1-2019 |
| Indiana | 90.1-2007 | 90.1-2007 |
| Iowa | 2012 IECC og 90.1-2010 | 90.1-2007 |
| Kansas | Lokalt selvstyre | Intet statsdækkende kodeks |
| Kentucky | 2012 IECC og 90.1-2010 | 90.1-2007 |
| Louisiana | 2021 IECC og 90.1-2019^ | 90.1-2016 |
| Maine | 2015 IECC og 90.1-2013 | 90.1-2013 |
| Maryland | 2021 IECC og 90.1-2019^ | 90.1-2019 |
| Massachusetts | 2018 IECC og 90.1-2016^ | 90.1-2019 |
| Michigan | 2015 IECC og 90.1-2013^ | 90.1-2013 |
| Minnesota | 90.1-2019^ | 90.1-2019 |
| Mississippi | Ingen statsdækkende | Intet statsdækkende kodeks |
| Missouri | Lokalt selvstyre | Intet statsdækkende kodeks |
| Montana | 2021 IECC og 90.1-2019 | 90.1-2019 |
| Nebraska | 2018 IECC og 90.1-2016 | 90.1-2013 |
| Nevada | 2018 IECC og 90.1-2016 | 90.1-2013 |
| New Hampshire | 2018 IECC og 90.1-2016^ | 90.1-2013 |
| New Jersey | 90.1-2019 | 90.1-2019 |
| New Mexico | 2021 IECC og 90.1-2019^ | 90.1-2019 |
| New York | 2018 IECC og 90.1-2016^ | 90.1-2016 |
| North Carolina | 2015 IECC og 90.1-2013^ | 90.1-2010 |
| North Dakota | Lokalt selvstyre | Intet statsdækkende kodeks |
| Ohio | 2021 IECC og 90.1-2019^ | 90.1-2016 |
| Oklahoma | 2006 IECC og 90.1-2004 | <90.1-2007 |
| Oregon | 90.1-2019 | 90.1-2019 |
| Pennsylvania | 2018 IECC og 90.1-2016 | 90.1-2013 |
| Rhode Island | 2018 IECC og 90.1-2016^ | 90.1-2013 |
| South Carolina | 2009 IECC og 90.1-2007 | 90.1-2007 |
| South Dakota | Lokalt selvstyre | Intet statsdækkende kodeks |
| Tennessee | 2021 IECC og 90.1-2013 | 90.1-2007 |
| Texas | 2015 IECC og 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC og 90.1-2019^ | 90.1-2019 |
| Vermont | 2021 IECC og 90.1-2019^ | 90.1-2019 |
| Virginia | 2021 IECC og 90.1-2019^ | 90.1-2019 |
| Washington | 2018 Washington State Energy Code | 90.1-2019 |
| Tennessee | 2012 IECC og 90.1-2010 | 90.1-2007 |
| Texas | 2015 IECC og 90.1-2013 | 90.1-2013 |
| Utah | 2021 IECC og 90.1-2019^ | 90.1-2019 |
| Vermont | 2018 IECC og 90.1-2016^ | 90.1-2019 |
| Virginia | 2021 IECC og 90.1-2019^ | 90.1-2019 |
| Washington | 2018 Washington State Energy Code | 90.1-2019 |
| West Virginia | 90.1-2013 | 90.1-2013 |
| Wisconsin | 2015 IECC og 90.1-2013^ | 90.1-2010 |
| Wyoming | Lokalt selvstyre | Intet statsdækkende kodeks |
- ^ Når en ændring, der påvirker energieffektiviteten, kan kvantificeres ved hjælp af DOE Prototype Building Models, blev den medtaget i analysen.
- For stater, der vedtager både IECC og 90.1, analyseres IECC-koden normalt som statens gældende kode i denne undersøgelse, undtagen for stater med omfattende ændringer af IECC.
Design Guide Key Concepts for Conference Rooms
Designing an energy-efficient lighting control solution for conference rooms involves strategic placement of occupancy sensors to ensure comprehensive coverage of the space.

Designing an energy-efficient lighting system for a conference room involves strategic placement of occupancy sensors to ensure comprehensive coverage. Here are some guidelines to consider:
- Indgangsdækning: Install a wall-mounted sensor near the entrance to detect when someone enters or exits the room. This sensor should be positioned high enough to avoid obstruction from the open door and should not directly face the entrance to avoid false triggers from movement outside the room.
- Table Coverage: Place a ceiling-mounted sensor above the conference table to detect occupancy in the main area of the room. This sensor should be positioned centrally to ensure comprehensive coverage.
- Presentation Area Coverage: If your conference room has a dedicated presentation area, consider installing an additional wall-mounted sensor to cover this space. This sensor should be positioned to avoid any potential obstructions, such as screens or projectors.
- Wall Control: Install a wall control unit near the entrance for manual override or adjustments of the lighting settings. This control should be easily accessible upon entering or exiting the room.
- Avoidance of Obstructions and Interference: Ensure that sensors are not placed near air vents to prevent interference from air flow or vibrations. Also, consider the height and placement of furniture to avoid blocking the sensor’s field of view.
- Integration with Existing Systems: Our occupancy sensors can be integrated with existing lighting systems for seamless operation. They can also be programmed to turn off all lights after a certain period of inactivity, further enhancing energy efficiency.
Udvalgte produkter & løsninger
Kernefunktioner inkluderet:
- Integreret manuel TÆND/SLUK-kontrol for al belysning
- Fraværelsessensorer (kun manuel TÆND): Lys skal kun tændes manuelt
- Justerbar tidsforsinkelse, lyset slukkes automatisk helt efter 15 minutter
- Ekstra: multi-location trådløse sæt til at udvide kontrolområdet uden omlægning af ledninger
- Ekstra: flere tilslutningsmuligheder tilgængelige for både nybyggeri og renoveringsprojekter.

Opfylder de obligatoriske bestemmelser
IECC – 2011
C405.2.1 Beboersensorkontroller
Beboersensorkontroller skal installeres for at styre lyset i rummet.
C405.2.1.1 Beboersensorkontrolfunktioner
- Manuel tænd eller delvis tænd med højst 50% effekt.
- Fuldstændig sluk inden for 20 minutter efter alle beboere har forladt rummet
- En manuel kontrol til at slukke lyset.
ASHRAE 90.1 – 2022
9.4.1.1 a Local control
There shall be one or more manual lighting control device that provides ON and OFF control
of all lighting in the space.
9.4.1.1 b Restricted to manual ON
None of the lighting shall be automatically turned on
9.4.1.1 c Restricted to partial automatic ON
No more than 50% of the lighting power for the general lighting shall be allowed to be automatically turned on
** NOTE: At least one 9.4.1.1 b or 9.4.1.1 c shall be implemented.
9.4.1.1 h Automatic full OFF control
Al belysning i rummet skal automatisk slukkes inden for 20 minutter efter alle beboere har forladt rummet
Title 24 – 2022
130.1 (a) Manuelle arealkontroller.
Hvert område afgrænset af loftshøje skillevægge skal have belysningskontroller, der tillader, at belysningen i dette område manuelt kan tændes og slukkes.
130.1 (c) SLUK-kontroller.
Belysning skal styres med beboersensorer for automatisk at slukke al belysning inden for 20 minutter eller mindre efter kontrolzonen er ubeboet, som skal fungere enten som:
- A. Beboersensorer (hvis 130.1(b) ikke kræver at have flerniveaubelysningskontroller); eller
- B. Delvis TÆND-beboersensorer, eller
- C. Bevægelsessensorer, hvor al belysning kun reagerer på manuel TÆND-input
Lad os høre dig.
Lad Rayzeek hjælpe med at designe og levere en skræddersyet energibesparende belysningsløsning til dig.